1. Locate micro switches 1 and 2 that are wired in series on the micro switch assembly Figure 1 Disconnect the yellow wire from micro switch 1 from the red wire from micro switch 2 Disconnect the black wire from micro switch 1 from the green wire Connect the green wire to the red wire from micro switch 2 Figure 2 At this point you can adjust the micro switch assembly with the supplied wrench through the slot in the bottom of the top pan see above drawing After you have reached the desired show position raise and lower the unit several times in order to verify show position 8 LP Morgan user manual LP Morgan Commercial Lift Instructions Adjusting Commercial Lift Show Position past standard position 46cm Figure 1 Figure 2 LP Morgan user manual 9 For more information on our range of products please visit www Ipmorgan com au or contact your local LP Morgan Retailer Factory 4a 6 Albert Street Preston Vic 3072 Phone 61 3 9480 6233 Fax 61 3 9480 6533 lp m g Email info herma com au www Ipmorgan com au Or an P October 2011 Version 1
2. down Moving toggle switch to up will start lift up When lift is in show position travel will automatically be stopped by factory set limit switches Whenever switch is placed in centre off position operation will stop One 12V key switch will lower lift from show to service position LP Morgan user manual 3 LP Morgan Commercial Lift Instructions Installing Projector The Scissor Lift has a grounded 220V AC 50Hz power cord for projector power supply The power cord is laced down the back scissor and is hot at all times Control cables should be laced through our Cable Management System Make sure to use flexible cables and to allow enough cable at each turn so cables do not stretch or kink This will ensure that cords do not become tangled and damaged during Scissor Lift operation Unit and projection system should be operated checked and adjusted as necessary at this time WARNING Keep fingers and other objects away from automatic ceiling closure and scissor mechanisms when unit is operating Serious injury or damage could result 15 mm dia mounting holes Fail safe inertial safety belt system Space for y7 projector s _ ceiling B S ace for projector mounting P proj bracket DA Optional ceiling oo closure panel 51 mm Pair of 5 mm aircraft cables Model Closed Height Extended Height Commercial Lift 35mm 3000mm 4 LP Morgan user manual LP Morgan Com
3. the Herma Logo Galleria LP Morgan and LP Morgan logo are registered trademarks of Herma Technologies Other trademarks and trade names used in this document remain the property of the relevant owners October 2011 Version 1 2 LP Morgan user manual LP Morgan Commercial Lift Instructions Electrical Connections Unit operates on 220V AC 50 Hz Removing the top cover of the unit and opening the electrical box exposes terminals for field connections Unit is shipped with internal wiring complete Wire to connect unit to power supply should be furnished by installer Connections should be made in accordance with wiring diagram and wiring should comply with national and local electrical codes All operating switches should be off before power is connected Scissor Lift should be operated and checked prior to installing projector and or optional ceiling closure Standard switch shown below comes with 22 meters of cable and should be plugged in to box on front of top pan of lift to control lift Operation When unit is first operated be cautious If unit fails to operate when toggle switch is flipped down return switch to off and recheck electrical connections before proceeding Cycle unit down and up several times to confirm satisfactory operation Standard Single Station Control CE Approved One 12V toggle switch moving 3 position toggle switch to down position will start lift
4. LP Morgan Commercial Lift user manual LP Morgan Commercial Lift Instructions Table of contents Electrical Connections 3 Operation 3 Installing Projector 4 5 Typical Installation Details Adjusting Show Position 7 Up to Standard Position Adjusting Commercial 8 9 Lift Show Position past 6 standard position 46cm CAUTION Read instructions completely before proceeding Test lift prior to installation Follow instructions carefully Installation contrary to instructions voids warranty Do not obstruct operation of Commercial Lift with fingers or any object Serious injury or damage could result Scissor Lift is designed to accommodate ceiling suspended eguipment Eguipment should not be allowed to rest on optional ceiling closure during operation Refer to section titled Installing Projector Entire bottom of the unit must be unobstructed to permit proper operation Sufficient clearance must be allowed below projector or optional ceiling closure Unit must be installed level please use a spirit level Unit operates on 220V 50 Hz AC Note Unit has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment Information in this document is subject to change without notice O Herma Technologies All rights reserved This document is protected against unauthorised copying electronic or otherwise Trademarks used in this text Herma
5. RDRD RD BK BE BK BK RD 3 gt 3E Wall Switch Limit switch UP BE BE N eUp Toggle Limit I ay gg Switch 8 sisis Sis key amp K_J amp Common Dn Switch Down Down DPDT Q Q Y S BN Yellow AD ff l 8ed 7 Service position 7 Show position yA Key Q O Up Red Limit switch Limit switch BE BE nb BN WH BK GN RD y a Momentary AD BE 12V SPAN Down wd Key Brown Switch ooo 6 LP Morgan user manual LP Morgan Commercial Lift Instructions Adjusting Show Position Up to Standard Position 1 Find the empty slot in the bottom of the top pan of lift the only empty slot 2 Use the open end wrench provided 3 Find the threaded coupling long nut just inside the top pan through the slot 4 Push wrench toward rear of unit to lower 5 Pull wrench toward front of unit to raise g g Decrease Show f Increase Show Position Position stops higher stops lower Front N Rear Show Position Adjustments LP Morgan user manual 7 LP Morgan Commercial Lift Instructions Adjusting Commercial Lift Show Position past standard position 46cm 1 If the desired show position is beyond the standard position 46cm but not more than half the service position proceed to step 7 If the desired show position is over half the service position proceed with the following steps Remove the top pan cover of the Commecial Lift
6. mercial Lift Instructions Typical Installation Details Mounting brackets with Typical mounting 14 3 mm dia holes hardware 12 7 mm threaded rods Scissors positioned by installer on left and right Stabilizing 3rd scissor on rear Drive system enclosure Bottom pan SMS Low Profile Mount with Universal Bra cket Fail safe iner tial safety belt Typical projector by others LP Morgan user manual 5 LP Morgan Commercial Lift Instructions Typical Installation Details Dashed wiring by Transformer RED A T3 WH BLUE electrician Transformer A AA Fuses and fuse clips S G Yw 7 provided by Draper are fn 3 located in the electr ical a box also pro vided UU ik i Capacitor 1 L 1 2 3 4 J5 T6 T7 Te T9 fio UU HH MW ag A A Up Relay Down Relay comenton Ff BE BE C BE f NC LT Board g NO LRD N0 BK BE Mot RD l COM RD BE 4 00M BI ter OC 1 2 3 4 5 718 ini BE R BE BK L BKRD BK Lek 6 Conductor Modular Cab le 75 supplied YW BE