Home

PDF Installation Manual

image

Contents

1. PRODUCT union Quick Start Guide CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhouzi St Neihu Taipei 114 Taiwan T 886 2 26591021 F 886 2 26590237 E sales ctcu com techsupport ctcu com marketing ctcu com H www ctcu com ce WA Oe ISO 9001 Quality System Certified 2013 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to change without notice Introduction User Guide 1 25G MultiRate 2R Transponder FRM220 1000DS Table of Contents Introduction amp Features _ 1 Specifications 2 Management Features 2 Panel Installation 3 LED Indicators 4 Application 4 Application CWDM __ 3 Console Management 6 8 Upgrading 8 About SFP Units 9 Version 1 0 Feb 2013 www CTCU com FRM220 1000DS is a multi rate up to 1 25G 2R optical repeater device The 2R consists of Re amplification and Re shaping The transponder card converts a data signal to the correct wavelength for transmission on a specific channel by supporting SFP optics on both line side and client side interfaces When FRM220 1000DS card is placed in FRM220 rack with SNMP management the management can view the converter card s status type version fiber link status and alarms The card can be configured to enable
2. Use the ESC to return to logout Any setting is immediately applied to the transponder s circuitry but not saved After all of the parameter settings have been selected return to the Device sub menu from the main menu and press 5 to store the configuration in non volatile RAM NVR Explanation of Settings lt 1 gt SFP 1 This will bring up the sub menu for the first SFP port enable disable ALS and view the SFP details including Digital Diagnostics lt 2 gt SFP 2 This will bring up the sub menu for the second SFP port enable disable ALS and view the SFP details including Digital Diagnostics lt 3 gt Device This brings up the sub menu to enable disable the device enable disable LFP store settings perform factory default and reset the device lt P gt Password Use this menu item to set the device login password to protect it from unauthorized access Ver 1 000 1 000 0 000 0 000 CH 01M 1 Status and Conf Link Down Exist D D Function iguration gt gt Dp 1 Port Active Enable 1 Bandwidth Full to Laser Shutdown Disable FP Digital Diagnostics lt ESC gt Go to previous menu Explanation of Settings lt 1 gt SFP 1 Port Active This will enable or disable the SFP 1 port lt 2 gt SFP 1 Bandwidth This setting controls an optional control for received bandwidth mostly for Fiber Channel 1x and 2x rates Not all SFP support this feature
3. 0 NMC Software Operation Manual 8 www CTCU com About SFP Units The FRM220 1000DS accepts any SFP unit that complies with the MSA standard Follow all ESD precautions when handling the card and SFP modules Fiber optic components and cables are very sensitive to dirt dust and mishandling especially in high speed networks Dirty or mistreated fiber may cause errors and an unwanted degradation of signal quality Remove the dust caps on SFP only when ready to plug in optical cables When choosing SFP optical modules the SFP must be able to support the required data rate OC3 SFP 155M will operate fine at STM 1 and Fast Ethernet speeds but not all modules will operate at lower speeds E3 T3 or STM 0 Make sure the SFP modules chosen are suitable for the required data rate wavelength and distance Installation CTC Union supplied SFP modules are of the Bale Clasp type The bale clasp SFP module has a bale clasp that secures the module into the SFP cage e Inserting a Bale Clasp SFP Module into a SFP cage Step 1 Close the bale clasp upward before inserting the SFP module Step 2 Line up the SFP module with the port and slide it into the cage e Removing a Bale Clasp SFP Module Step 1 Open the bale clasp on the SFP module Press the clasp downward with your index finger Step 2 Grasp the SFP module between your thumb and index finger and carefully remove it from the SFP cage i cil JSS a a Bale Clasp type SFP wi
4. agement When placed in the 1 slot CHO1M or 2 slot CHO2M chassis this card can be locally managed by connecting a simple serial terminal such as a notebook computer that has an RS232 port or via a commonly available USB to RS232 adapter In Windows XP HyperTerminal is an application available for emulating a serial terminal You can also search for TeraTerm or PuTTY which are free alternatives especially if the operating system is Vista or Win7 Settings Baud Rate 38 400 Data bits 8 Parity bits none Stop bits 1 Handshaking none Emulation VT 100 Default username password admin admin Connect the serial cable to the CH01 2M s DB9 Run the terminal emulation program With power on press ESC space or Enter to display the Login Menu screen The following is an example KKEKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK CTC UNION TECHNOLOGIES CO LTD KER FRM220 1000DS Manager ERK KKEKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK CH 02M S1 Ver 1 000 1 000 0 000 0 000 User Name admin Password Example of Login Menu Console Screen FRM220 1000DS zb www CTCU com 000 1 000 0 000 0 000 CH 01M Up D D Function Up D D Function SPF 1 Status and Configure SFP 2 Status and Configure Device S E tatus and Configure lt P gt Password change lt ESC gt Logout Operation Select any of the menu items by keying in the menu item number or letter
5. but it is available for those that do lt 3 gt Auto Laser Shutdown This will enable the ALS safety feature so that laser Tx is disabled if Rx suffers LoS Loss of Signal lt 4 gt SFP Digital Diagnostics MSA compliant SFP are able to have internal data read to display vendor name part number etc In addition SFP that support DDOM digital diagnostic optical monitoring will display additional data such as receive optical power and internal temperature Example of reading Digital Diagnostics in SFP from SFP 1 sub menu Ver 1 000 1 000 0 000 0 000 CH 01M lt lt Fiber 1 D D Function Status gt gt Vendor Name CTC UNION Vendor Part Number SFS 7010 L31 DDI Fiber Type Single Wave Length 1310 no Link Length 0010 Km Rx Power 40 dBm Rx Sensitivity 20 dBm Temperature 046 C n n Tx Power 06 dBm n n lt ESC gt Go to previous menu Example of SFP 1 DD Console Screen FRM220 1000DS Upgrading The FRM220 1000DS card may be firmware upgraded when it is placed in the FRM220 with NMC management card The user may use a local console connection to the NMC a remote Telnet IP connection or a Web based HTTP connection with any available browser The NMC communicates to all cards through a serial R8485 control bus The upgrade code is transferred to the NMC by way of TFTP server All of these mentioned upgrade methods are well documented in the FRM22
6. nk Green On SFP Port 1 Fiber link SFP1 Off SFP Port 1 No Fiber link Link Green On SFP Port 2 Fiber link SFP2 Off SFP Port 2 No Fiber link Application FRM220 1000DS 2R repeater works in point to point applications either as a stand alone or when placed in FRM220 CH20 managed rack Extension Repeater 1000DS 1000DS SFP 1 E Q a SFP 2 SFP 2 SFP 1 Install SFP modules appropriate for the data rate fiber type and fiber distance www CTtCU com CWDM Transponder FRM220 1000DS functions primarily as a repeater or a media converter As a repeater in fiber applications the signal is fully regenerated at the trunk In the CWDM DWDM application the repeater acts as a fiber to fiber transponder and optical frequency converter between the client side equipment and the Optical Multiplexer De multiplexer FRM220 CH20 20 slot chassis sEp 1000DS Mux Demux 1310 SFP me Pa id WAN SFP 2 1470 SFP 1470 SFP 1 l 1310 SFP G a nd SFP 2 1490SFP_ 1490 SFP 1 1550 SFP _O tage en SFP 2 1510SFP 1510 SFP 1 850 SFP Q a Q SFP 2 1530 SFP 1530 Because the transponder only supports 2R repeating it is not recommended for use in applications where multiple repeaters are cascaded over a long distance For such applications we recommend using a 3R transponder such as our FRM220 2 7G 3R transponder 25 www CTCU com Console Man
7. or disable the port and reset the port Features Supports multiple protocols and data rates from 28Mbps to 1 25Gbps Repeater functions for re amplification and re shaping Low cost transponder application Supports rack management or stand alone via console Supports Auto Laser Shutdown ALS and Link Fault Pass through LFP Digital Diagnostic Monitor of supported SFP modules The SFP sockets support a wide range of standard SFP modules to address any network situation Single mode Multi mode Multi rate Single fiber bi directional Coarse and Dense Wave Division Multiplexing CWDM and DWDM Copper media WARNING Fiber optic equipment may emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a laser light source www CTCU com Specifications Optical Interface Connector SFP cage Data rate 28Mb s to 1 25Gbps GbE Duplex mode Full duplex protocol transparent Fiber Depends on SFP Distance Depends on SFP Wavelength Depends on SFP Indications LED PWR SFP1 Link SFP2 Link Power Card supports hot swapping m Input Card 12VDC Standalone AC DC options Consumption lt 6W Dimensions 155 x 88 x 23mm D x W x H Weight 110g 0 50 C Operating 0 70 C Storage Humidity 10 90 non condensing Certification CE FCC LVD RoHS MTBF 75000 h
8. rs 25 C Temperature Management Features This model has no DIP Switch which can be used to configure the devices for stand alone operation Therefore it must be placed in a stand alone chassis with console port This device supports a text based serial terminal with an easy to use menu system for configuration When placed in a managed chassis the card is configured and monitored through the chassis NMC network management controller via console Telnet Web HTTP or SNMP Factory Default When placed in a single slot chassis such as CH01 with factory default settings this converter has both SFP ports enabled ALS for each port is disabled and the device has LFP disabled www CTCU com Panel Figure 1 Front Panel of FRM220 1000DS LED Indicators FRM220 1000DS Installation Figure 2 Slide in Card mounting of FRM220 1000DS Note This converter card can be placed in CH01 CH0O1M 1 slot w console CHO2M 2 slot w console CHO2 NMC 2 slot with NMC or the full CH20 chassis RQ Ps CH20 Chassis DORNA w NMC CH02M Chassis RL AC DC 2AC eo 2DC or AD NF Ho CH01M oS AC DC 2AC 2DC or AD ae CH02 NMC Chassis AC DC 2AC 2DC or AD Da Follow all ESD precautions when handling the card and SFP modules ei www CTCU com LED Indicators PWR SFP 1 Link SFP 2 Link LED State Status PWR Green On Power on Flash During upgrade rapid flash Blink Port Disabled slow blink Off No Power Li
9. th bale open www CTCU com

Download Pdf Manuals

image

Related Search

Related Contents

Powerline PassThru Adapters User Manual  Baixar - Febrace  USER`S MANUAL    MITO E2-04  3D Innovations 700P Dishwasher User Manual  le raVel, notre réseau vert régional  Installation eines Barco-Display  DAUPHINE LIBERE  

Copyright © All rights reserved.
Failed to retrieve file