Home

Betriebsanleitung 712 Spannungssteller/Operating Instructions 712

image

Contents

1. gt Touch the PE fixing screw or any other earthed metal surface EDB712 DE EN 2 1 Lenze 51 5 1 3 5 1 4 5 1 5 5 1 6 5 1 7 52 Electrical installation Important notes Shielding Shielding Shield all wires to and from the drive controller gt Connect the shield near to the ends of the wires to the central earth wire connection Prevent earth fault gt Prior to commissioning ensure there are no connection cables with earth faults Mains potential IN Danger Dangerous electrical voltage gt All device terminals carry dangerous mains potential Protective measures All control signals must be safely electrically isolated outside the drive controller Prevent direct contact with the live parts using a protective cover as double basic insulation Setpoint potentiometer IN Danger Dangerous electrical voltage If you use the setpoint potentiometer supplied earth the mechanical screw fastening isolate the electrical connections or cover the connections gt On use with a master voltage remove the setpoint potentiometer and connect the master voltage to terminal 7 and terminal 8 The master voltage must be floating and not be referenced to the mains If several devices are to be operated on one master voltage use electrical isolation Switching spike reduction gt To limit switching spikes that may occur on the operation of a reversing contactor circuit to initiate reversin
2. Der Antriebssteller wird ber einen externen Kontakt der an den Klemmen 16 und 17 anzuschliessen ist freigegeben Dazu ist ein Schwachstromkontakt 10 V 10 mA zu verwenden Hinweis Verwenden Sie geeignete Relaiskontakte wenn Steuersignale per Relais umgeschaltet werden Bei geschlossenem Schalter RFR ist der Antriebssteller freigegeben Ist RFR ge ffnet werden die Z ndimpulse und der Antriebssteller zur ckgesetzt EDB712 DE EN 2 1 Lenze 29 5 Elektrische Installation Anschlussplan Erweiterung des Drehmomentstellbereichs 5 3 4 Erweiterung des Drehmomentstellbereichs Das Ger t ist im Auslieferungszustand fiir den Betrieb ohne Mittelpunktleiter eingerichtet Hierbei betragt der Drehmomentstellbereich ca 1 20 Wird ein h herer Stellbereich gew nscht so sind zwei Ma nahmen dazu erfor derlich gt Anschliessen des Mittelpunktleiters an den Sternpunkt des Motors gt Ersetzen des auf L tst tzpunkten vorhandenen Widerstands Position R420 werkseitig mit 22 kQ Widerstand best ckt durch einen 100 kQ Widerstand 712_006 Abb 8 Ersetzen des 22kQ Widerstands durch einen 100 kQ Widerstand auf Position R420 30 Lenze EDB712 DE EN 2 1 Inbetriebnahme Wichtige Hinweise 6 Inbetriebnahme 6 1 Wichtige Hinweise IN Gefahr A EDB712 DE EN 2 1 Gef hrliche elektrische Spannung Die Inbetriebnahme darf nur von qualifizierten Fachkr ften mit isoliertem Werkzeug vorgenommen werden Gefahr
3. 0 0089 Jumpers for changing mains This documentation applies to Voltage controller 712 from the nameplate data 712 E 3x Product range Voltage controller 712 712 66kW Design E Built in unit Hardware version x B EDB712 DE EN 2 1 Lenze 37 Document history Material number 00389535 00389535 13148242 13283222 Gg Tipp Version n def n def 1 0 2 0 2 1 12 1992 05 1996 02 2007 12 2008 03 2010 TDOO TDOO TD03 TD29 TDOO Description Complete revision Complete revision New edition due to reorganisation of the com pany New address Documentation and software updates for further Lenze products can be found on the Internet in the Services amp Downloads area under http www Lenze com 38 Lenze EDB712 DE EN 2 1 Contents i 5 3 1 Drive controller type 712 for mains connection 340 460V 5 5 3 2 Drive controller type 712 for mains connection 190 265V 58 5 3 3 Connection of control signals to the drive controller 712 6 EDB712 DE EN 2 1 Lenze 39 i Contents 40 Lenze EDB712 DE EN 2 1 Preface and general information 1 1 Preface and general information Using the voltage controller 712 the torque of three phase asynchronous motors with resistive rotor behaviour up to a power rating of 3 3 kVA can be steplessly adjusted The torque is modified by changing the slip using phase control on the stator voltage This voltage controller
4. Bemessungsdaten Antriebssteller Baureihe 712 Ausgangsleistung Pel KW bezogen auf 380 V Netzspannung Ausgangsstrom Dauereffektivstrom I A Netzfrequenz f Hz Netzspannung Uri 12 13 u v min Spannung Umin Unetz v max Spannung Umax Unetz v Nenn Leitspannung Uin V Sollwertpotenziometer Daten R1 Art Nr Absicherung Leistungsteil Daten Art Nr Absicherung Elektronik Daten Art Nr Masse ca m kg 1 umstellbar durch manuelle Ver nderungen 26 2 Lenze Einstellung Lenze Typ 712 E 3B 6 6 3x10 50 60 190 265 1 340 460 2 0 0 25 0 5 1 10 10 kQ 1Wiin 322 194 3 St ck FF 16 A 6 3 x 32 mm super flink 305 725 M0 1 5 x 20 mm mitteltr ge 305 704 0 6 EDB712 DE EN 2 1 Technische Daten 3 Abmessungen 3 3 Abmessungen 712_001 Abb 1 Abmessungen Typ a b c d e mm mm mm mm mm mm 712 E 3B 115 170 100 160 60 4 EDB712 DE EN 2 1 Lenze 17 4 1 18 Mechanische Installation Wichtige Hinweise Mechanische Installation Wichtige Hinweise Die Umgebungstemperatur um die Antriebssteller darf 45 C nicht berschrei ten Sorgen Sie f r ausreichende Bel ftung wenn Sie den Antriebssteller in ein Gehduse einbauen gt Montieren Sie den Antriebssteller senkrecht mit den Klemmen nach unten IN Gefahr Gef hrliche elektrische Spannung Externe Schalter und Sicherungen m ssen vom Antriebssteller mindestens 250 mm en
5. Zerst rung des Antriebsstellers bei Drehfeldumkehr w hrend der Motor noch dreht Die Drehfeldumkehr darf auf keinen Fall bei freigegebenem Steller und drehenden Motor aktiviert werden M gliche Folgen gt Zerst rung des Antriebsstellers Schutzma nahmen Antriebsstellersperre aktivieren Motorstillstand abwarten Lenze 31 6 Inbetriebnahme Erstinbetriebnahme 6 2 Erstinbetriebnahme Schritt Abgleich fiir Sollwertvorgabe durch Poti KLemmen 7 8 9 oder Leitspannung Klemmen 7 8 1 Drehen Sie die Trimmer Umax Umin T nzer bis zum linken Anschlag 2 Stellen Sie Sollwertpoti oder Leitspannung auf Null 3 Schalten Sie das Netz ein und Schalter RFR schlie en Abgleich der minimalen Spannung 4 Erh hen Sie die Motordrehzahl durch Rechtsdrehen des Trimmers Umin bis das gewiinschte minimale Drehmoment eingestellt ist Wird als minimales Drehmoment Null ge w nscht Trimmer Umin soweit zur ck drehen bis sich der Motor gerade nicht mehr dreht um einen Totgang des Soll wertpotis im unteren Bereich zu vermei den Abgleich der maximalen Spannung 5 Stellen Sie das Sollwertpoti auf Maximum bzw Leitspannung auf UL 10 V 6 Erh hen Sie das Motordrehmoment durch Rechtsdrehen des Trimmers Umax bis das gew nschte maximale Drehmoment eingestellt ist Die Einstellung des minimalen Drehmo ments ist zu kontrollieren weil sich die minimale und
6. Lenze EN Safety instructions 2 Residual hazards 2 2 Residual hazards Protection of persons Drive controllers have degree of protection IP 00 All live parts are freely accessible gt Cover the live parts In this way you will prevent unintentional contact with dangerous voltages gt Switch off the mains before you work on the drive controller gt Prior to working on the drive controller check all terminals are electrically isolated Motor protection During the extended operation of self ventilated motors at low speeds the motor may overheat gt Use additional components for protection against dangerous overspeeds EDB712 DE EN 2 1 Lenze 45 Safety instructions Definition of notes used Definition of notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information Safety instructions Structure of safety instructions IN Danger characterises the type and severity of danger Note describes the danger and gives information about how to prevent dangerous situations Pictograph and signal word Meaning Danger of personal injury through dangerous electrical voltage IN Danger Reference to an imminent danger that may result in death or serious personal injury ifthe corresponding measures are not taken Danger of personal injury through a general source of danger I Reference to an imminent danger that may result in death or
7. Danger serious personal injury if the corresponding measures are not taken Danger of property damage Stop Reference to a possible danger that may result in property damage if the corresponding measures are not taken Application notes Pictograph and signal word Meaning Note Important note to ensure troublefree operation DI U 9 Tip Useful tip for simple handling O Reference to another documentation Lenze CARRI Technical data Technical data 3 General data and operating conditions General data and operating conditions Conformity Degree of pollution Climatic conditions Storage Transport Operation Mounting positions Mounting clearances Leakage current to PE in accordance with EN 61800 5 1 Degree of protection Insulation strength Mechanical strength EDB712 DE EN 2 1 CE Low voltage directive 2006 95 EC EMC directive 2004 108 EC VDE 0110 part 2 degree of pollution 2 In accordance with EN 60721 3 1 to 60721 3 4 no condensation average relative humidity 85 1K2 in accordance with IEC EN 60721 3 1 Temperature 0 C 45 C 2K2 in accordance with IEC EN 60721 3 2 Temperature 0 C 45 C 3K3 in accordance with IEC EN 60721 3 3 Temperature 0 C 45 C For operating ambient temperatures The ambient temperature must not exceed 45 C Vertical on a wall terminals downward 2 50 lt 3 5 mA IP 00 Overvoltage category Ill in accordance with VDE 0110
8. Furthermore repeat the calibration of the maximum voltage see steps 5 and 6 in position A Commissioning is complete Lenze EDB712 DE EN 2 1 Maintenance repair 7 7 Maintenance repair Fuse replacement The fuses protect the drive controller against incorrect operating conditions In the case of a fault faulty fuses must be replaced IN Danger Dangerous electrical voltage Troubleshooting fault correction the removal of the protective cover and the replacement of fuses are only allowed to be undertaken by qualified skilled personnel with the device electrically isolated Electrically isolate the system Check the drive controller and the system for faults if a fuse has blown Rectify the fault Remove the protective cover over the fuses Replace the faulty fuse only with a fuse of the stipulated type C2 66 After replacing the fuse re fit the protective cover Re connect the system to the mains NEO RENI EDB712 DE EN 2 1 Lenze 65 8 1 66 Appendix Accessories Appendix Accessories You can order the following accessories separately for drive controllers of type 712 E RFI filter Power fuses Fuse holder Drive controller RFI filter Power fuses Fuse holder Rotary knob Scale Zinc oxide varistor Replacement resistor for operation with neutral conductor pos R420 Resistors for modifying the mains voltage range pos R101 R103 Rotary knob and scale for setpoi
9. Beachten Sie dazu die Hinweise in der Dokumentation Nachdem der Antriebssteller von der Versorgungsspannung getrennt ist d r fen Sie spannungsf hrende Ger teteile und Leistungsanschl sse nicht sofort ber hren weil Kondensatoren aufgeladen sein k nnen Beachten Sie dazu die entsprechenden Hinweisschilder auf dem Antriebssteller Halten Sie w hrend des Betriebs alle Schutzabdeckungen und T ren geschlos sen Hinweis f r UL approbierte Anlagen mit eingebauten Antriebsstellern UL war nings sind Hinweise die nur f r UL Anlagen gelten Die Dokumentation enth lt spezielle Hinweise zu UL Wartung und Instandhaltung Die Antriebssteller sind wartungsfrei wenn die vorgeschriebenen Einsatzbe dingungen eingehalten werden Bei verunreinigter Umgebungsluft k nnen die K hlfl chen des Antriebsstellers verschmutzen oder K hl ffnungen verstopft werden Bei diesen Betriebsbedin gungen deshalb regelm ig die K hlfl chen und K hl ffnungen reinigen Dazu niemals scharfe oder spitze Gegenst nde verwenden Entsorgung Metalle und Kunststoffe zur Wiederverwertung geben Best ckte Leiterplatten fachgerecht entsorgen Beachten Sie unbedingt die produktspezifischen Sicherheits und Anwendungshinweise in dieser Anleitung Lenze EN Sicherheitshinweise 2 Restgefahren 2 2 Restgefahren Personenschutz Antriebssteller haben die Schutzart IP 00 Alle spannungsf hrenden Teile sind frei zuganglich Decken Sie spannungsf
10. VDE 0160 vibration test Lenze 49 3 2 48 Technical data Rated data Rated data Drive controller series 712 Output power Pel KW referred to 380 V mains voltage Output current continuous effective current I A Mains frequency f Hz Mains voltage U 1 12 13 u v Min voltage Umin Umains v Max voltage Umax U mains v Rated master voltage Uin V Setpoint potentiometer Data R1 Art no Fuse protection power section Data Art no Fuse protection electronics Data Art no Weight approx m kg 1 Can be changed by modifications 26 2 Lenze setting Lenze Type 712 E 3B 6 6 3x10 50 60 190 265 1 340 460 2 0 0 25 0 5 1 10 10 kQ 1Wiin 322 194 3 off FF 16 A 6 3 x 32 mm super fast 305 725 M 0 1 5 x 20 mm medium slow 305 704 0 6 EDB712 DE EN 2 1 Technical data 3 Dimensions 3 3 Dimensions 712_001 Fig 1 Dimensions Type a b c d e mm mm mm mm mm mm 712 E 3B 115 170 100 160 60 4 EDB712 DE EN 2 1 Lenze 49 4 1 50 Mechanical installation Important notes Mechanical installation Important notes The ambient temperature for the drive controller must not exceed 45 C gt Provide adequate ventilation if you install the drive controller in a housing gt Mount the drive controller vertical with the terminals pointing downward IN Danger Dangerous electrical voltage External switches and f
11. by soldering 220 kQ resistors 3 Solder three resistors 220 kQ 0 5 W in positions R101 R102 and R103 4 Re fit protective cover over the device printed circuit board if necessary EDB712 DE EN 2 1 Lenze 59 5 60 Electrical installation Connection plan Drive controller type 712 for mains connection 190 265 V PE L1 L2 L3 712_001 Fig 6 Connection drive controller 712 for mains connection 190 265 V Lenze EDB712 DE EN 2 1 Electrical installation 5 Connection plan Connection of control signals to the drive controller 712 5 3 3 Connection of control signals to the drive controller 712 7 Je oJ x2 13 sa 16 17 RFR 10K 1 W lin i Setpoint Controller I potentiometer enable A l I l 1 i 1 Master voltage l U 10V Dancer 712_005 Fig 7 Connection of setpoint signals and the controller enable gt The device can evaluate a setpoint signal from a potentiometer or master voltage using terminals 7 8 and 9 In addition for winding applications a second setpoint can be defined at terminals 12 13 and 14 using a dancer potentiometer gt The drive controller is enabled using an external contact to be connected to terminals 16 and 17 For this purpose a low current contact 10 V 10 mA is to be used Note Use suitable relay contacts if control signals are switched using a relay The drive controller is enabled with switch RFR closed If RFR is opened the enable p
12. hrende Teile ab Dadurch verhindern Sie den unbeabsichtigten Kontakt mit lebensgef hrlichen Spannungen Schalten Sie das Netz ab bevor Sie am Antriebssteller arbeiten gt berpr fen Sie vor Arbeiten am Antriebssteller ob alle Klemmen spannungslos sind Motorschutz gt Bei l ngerem Betrieb eigenbel fteter Motoren mit kleinen Drehzahlen kann der Motor berhitzt werden gt Setzen Sie zum Schutz gegen gef hrliche berdrehzahlen zus tzliche Komponenten ein EDB712 DE EN 2 1 Lenze 13 2 Sicherheitshinweise Definition der verwendeten Hinweise 2 3 Definition der verwendeten Hinweise Um auf Gefahren und wichtige Informationen hinzuweisen werden in dieser Dokumentation folgende Piktogramme und Signalworter verwendet Sicherheitshinweise Aufbau der Sicherheitshinweise IN Gefahr kennzeichnet die Art und die Schwere der Gefahr Hinweistext beschreibt die Gefahr und gibt Hinweise wie sie vermieden werden kann Piktogramm und Signalwort Stop Anwendungshinweise Piktogramm und Signalwort Hinweis Gg Tipp 14 Bedeutung Gefahr von Personensch den durch gef hrliche elektrische Spannung Hinweis auf eine unmittelbar drohende Gefahr die den Tod oder schwere Verletzungen zur Folge haben kann wenn nicht die entsprechenden Ma nahmen getroffen werden Gefahr von Personensch den durch eine allgemeine Gefahren quelle Hinweis auf eine unmittelbar drohende Gefahr die den Tod oder
13. maximale Spannung ge genseitig beeinflussen 10 11 Die Inbetriebnahme ist abgeschlossen 32 Lenze Erg nzender Abgleich bei zus tzlichem Einsatz eines T nzerpotenziometers Klemmen 12 13 14 Stellen Sie das Sollwertpoti auf Mittelstel lung bzw Leitspannung auf ca 5 V Mit dem Trimmer T nzer ist der ge w nschte Einfluss des Tanzerpotenziome ters einzustellen Stellung E verringert die Motorspan nung Stellung A erh ht die Motorspannung Nach Abgleich des T nzereinflusses den Abgleich der minimalen Spannung siehe Schritt 4 mit T nzerpotenziometer in Stellung E wiederholen Desweiteren den Abgleich der maximalen Spannung siehe Schritte 5 und 6 in Stel lung A wiederholen EDB712 DE EN 2 1 Wartung und Reparatur 7 7 Wartung Reparatur Sicherungswechsel Die Sicherungen sch tzen den Antriebssteller vor unzul ssigen Betriebsbe dingungen Im Fehlerfall m ssen defekte Sicherungen gewechselt werden IN Gefahr Gef hrliche elektrische Spannung Die Fehlersuche die Fehlerbehebung das Entfernen der Schutzabdeckung und der Sicherungswechsel d rfen nur spannungslos von qualifizierten Fachkr ften vorgenommen werden 1 Schalten Sie die Anlage spannungslos 2 Untersuchen Sie den Antriebssteller und die Anlage auf Fehler wenn eine Sicherung ausgel st hat 3 Beheben Sie den Fehler 4 Entfernen Sie die Schutzabdeckung ber den Sicherungen 5 Wechseln S
14. mounting surfaces Also connect the shields on the cables connected from contactors motor protection switches or terminals in the motor cable to the mounting plate using large area connections In the motor terminal box connect the shield and the motor housing using a metal cable gland to form a large area connection Connect shields on analogue control cables at one end Connect the shield on the control cables at both ends to the mounting plate using a large area connection If the mains cable between RFI filter and drive controller together is longer than 300 mm Shield the mains cables gt Connect the shield on the mains cables at both ends of the cable to the mounting plate using large area connections Earthing Drive actuator and RFI filter are metallic and conductive and must be earthed gt Connect all metal conductive components to a central earthing point gt For the wiring use the minimum cross section specified in the safety regulations Layout Note For EMC it is not the cable cross section that is of importance but the size of the contact area between the drive controller RFI filter and mains choke and the earthed mounting plate The use of electrically conductive mounting plates e g zinc coated ensures a permanent safe contact gt Remove the paint from the mounting areas if you use painted mounting plates gt Connect mounting plates e g together using copper strips an
15. schwere Verletzungen zur Folge haben kann wenn nicht die entsprechenden Ma nahmen getroffen werden Gefahr von Sachsch den Hinweis auf eine m gliche Gefahr die Sachsch den zur Folge haben kann wenn nicht die entsprechenden Ma nahmen getroffen werden Bedeutung Wichtiger Hinweis f r die st rungsfreie Funktion N tzlicher Tipp f r die einfache Handhabung Verweis auf andere Dokumentation Lenze EN 3 Technische Daten Technische Daten 3 Allgemeine Daten und Einsatzbedingungen 3 1 Allgemeine Daten und Einsatzbedingungen Konformit t Verschmutzungsgrad Klimatische Bedingungen Lagerung Transport Betrieb Einbaulagen Einbaufreir ume Ableitstrom gegen PE nach EN 61800 5 1 Schutzart Isolationsfestigkeit mechanische Festigkeit EDB712 DE EN 2 1 CE Niederspannungsrichtlinie 2006 95 EG EMV Richtlinie 2004 108 EG VDE 0110 Teil 2 Verschmutzungsgrad 2 nach EN 60721 3 1 bis 60721 3 4 ohne Betauung mittlere relative Feuchte 85 1K2 nach IEC EN 60721 3 1 Temperatur 0 C 45 C 2K2 nach IEC EN 60721 3 2 Temperatur 0 C 45 C 3K3 nach IEC EN 60721 3 3 Temperatur 0 C 45 C Bei Betriebs Umgebungstemperatu ren Die Umgebungstemperatur darf 45 C nicht Uber schreiten Senkrecht an einer Wand Klemmen nach unten Q 18 lt 3 5 mA IP 00 Uberspannungskategorie Ill nach VDE 0110 VDE 0160 Schwingpr fung Lenze 15 3 2 16 Technische Daten Bemessungsdaten
16. te die nach EN 55022 Klasse B nicht st rfest sind k nnen durch die Antriebssteller elektromagnetisch beeintr chtigt werden Betreiben Sie in der N he der Antriebssteller ausschlie lich nach EN 55022 Klasse B st rfeste Ger te 24 Lenze EDB712 DE EN 2 1 Elektrische Installation 5 Anschlussplan Antriebssteller Typ 712 f r Netzanschluss 340 460 V 5 3 Anschlussplan 5 3 1 Antriebssteller Typ 712 fiir Netzanschluss 340 460 V PE L1 L2 L3 712_002 Abb 3 Anschluss Antriebssteller 712 f r Netzanschluss 340 460 V Das Ger t ist werkseitig auf den Netzspannungsbereich 340 460 V 0 festgelegt Das Ger t kann auf den Netzspannungsbereich 190 265 V 0 umgestellt werden us 26 EDB712 DE EN 2 1 Lenze 25 5 Elektrische Installation Anschlussplan Antriebssteller Typ 712 f r Netzanschluss 190 265 V 5 3 2 Antriebssteller Typ 712 fiir Netzanschluss 190 265 V Hinweis Der Antriebssteller 712 ist werkseitig f r den Betrieb mit 340 460 V eingerichtet F r den Betrieb mit 190 265 V m ssen eine L tbr cke ver ndert werden und drei 220 kQ 0 5 W Widerst nde auf den Best ckungspl tzen R101 R102 und R103 eingel tet werden IN Gefahr Der Umbau f r den Betrieb an 190 265 V darf nur spannungslos von qualifizierten Fachkr ften vorgenommen werden 240 V 3 400 V Abb 4 Umstellung des Antriebsstellers 712 auf Netzanschluss 190 265 V durch L tbr ckenver nder
17. type series L12 10F4 10F8 F12 S4 1156 S8 F8 10F4 11MF4 or similar EDB712 DE EN 2 1 Lenze 53 5 2 2 54 Electrical installation EMC compliant installation Installation of a CE typical drive system Installation of a CE typical drive system Note The EMC characteristics of a drive system are installation dependent For this reason pay attention to the instructions on filtering shielding earthing and layout Note If a different installation is used e g gt usage of unshielded cables gt usage of common RFI filters instead of the specified RFI filters the machine or the system must be checked for compliance with EMC limits for the assessment of conformity with the CE EMC directive Filtering RFI filters reduce high frequency interference to a permissible level gt Only use the RFI filter specified for the drive controller The selection of a suitable RFI filter is dependent on the load current Load current Order designation lt 8A EZF3_008A002 lt 10A EZF3_012A001 Add further interference suppression measures if the motor cables are longer than 50 m Lenze EN Electrical installation 5 EMC compliant installation Installation of a CE typical drive system Shielding gt Shield all wires from and to the drive controller Connect the shield on the motor cable to the mounting plate near the drive controller using a large area connection Use earthing clamps on bare metal
18. E Befestigungsschraube oder eine andere geerdete Metallfl che EDB712 DE EN 2 1 Lenze 19 5 1 3 5 1 4 5 1 5 5 1 6 5 1 7 20 Elektrische Installation Wichtige Hinweise Abschirmung Abschirmung Schirmen Sie alle Leitungen vom und zum Antriebssteller ab Verbinden Sie die Abschirmung nahe der Leitungsenden mit dem zentralen Schutzleiteranschluss Erdschluss vermeiden gt Vor Inbetriebnahme darauf achten da keine Anschlussleitung einen Erdschluss aufweist Netzpotenzial IN Gefahr Gef hrliche elektrische Spannung gt Alle Ger teklemmen f hren lebensgef hrdendes Netzpotenzial Schutzma nahmen Alle Steuersignale m ssen au erhalb des Antriebsstellers elektrisch sicher getrennt sein Verhindern Sie direktes Ber hren der spannungsf hrenden Teile durch eine Schutzabdeckung als doppelte Basisisolierung Sollwertpotenziometer IN Gefahr Gef hrliche elektrische Spannung Wenn Sie das mitgelieferte Sollwertpotenziometer verwenden erden Sie die mechanische Schraubbefestigung isolieren Sie die elektrischen Anschl sse oder decken Sie die Anschl sse ab gt Bei Leitspannungsbetrieb das Sollwertpotenziometer entfernen und die Leitspannung an die Klemme 7 und Klemme 8 legen Leitspannung mu netz und potenzialfrei sein Mehrere Ger te nur ber galvanische Trennungen an einer Leitspannung betreiben Schaltspitzenreduktion gt Zur Begrenzung von Schaltspitzen die beim Betri
19. EDB712 13283222 Betriebsanleitung Operating Instructions 712 712 E 3B Spannungssteller Voltage controller Lenze Lesen Sie zuerst diese Anleitung bevor Sie mit den Arbeiten beginnen Beachten Sie die enthaltenen Sicherheitshinweise Please read these instructions before you start working Follow the enclosed safety instructions Funktionselemente Bauteilkennzeichnung Bauteilbezeichnung Best ckungspl tze R101 R103 zur Netzanpassung Elektroniksicherung Leistungsanschl sse Steuerklemmen Trimmer f r Umax Umin und Utsnzer 0 0089 Drahtbr cke zur Netzanpassung Diese Dokumentation ist g ltig f r Spannungssteller 712 ab der Typenschildbezeichnung 712 E 3x Produktreihe Spannungssteller 712 712 66kW Ausf hrung E Einbauger t Hardwarestand x B EDB712 DE EN 2 1 Lenze Dokumenthistorie Materialnummer 00389535 00389535 13148242 13283222 Gg Tipp Version n def n def 1 0 2 0 2 1 12 1992 05 1996 09 2006 12 2008 03 2010 TDOO TDOO TD03 TD29 TDOO Beschreibung Komplette Uberarbeitung Komplette Uberarbeitung Neuauflage wegen Neuorganisation des Unter nehmens Neue Adresse Dokumentationen und Software Updates zu weiteren Lenze Produkten finden Sie im Internet im Bereich Services amp Downloads unter http www Lenze com Lenze EDB712 DE EN 2 1 Inhalt i 2 1 Allgemeine Sicherheits u
20. achten Sie die Hinweise f r Transport Lagerung und sachgem e Handha bung Halten Sie die klimatischen Bedingungen ein siehe ggf Kapitel Technische Da ten Aufstellung Sie m ssen die Antriebssteller nach den Vorschriften der zugeh rigen Doku mentation aufstellen und k hlen Sorgen Sie f r sorgf ltige Handhabung und vermeiden Sie mechanische berla stung Verbiegen Sie bei Transport und Handhabung weder Bauelemente noch ndern Sie Isolationsabst nde Ber hren Sie keine elektronischen Bauelemente und Kontakte Antriebssteller enthalten elektrostatisch gef hrdete Bauelemente die Sie durch unsachgem e Handhabung leicht besch digen k nnen Besch digen oder zerst ren Sie keine elektrischen Komponenten da Sie dadurch Ihre Ge sundheit gef hrden k nnen Elektrischer Anschluss Beachten Sie bei Arbeiten an unter Spannung stehenden Antriebsstellern die geltenden nationalen Unfallverh tungsvorschriften z B VBG 4 F hren Sie die elektrische Installation nach den einschl gigen Vorschriften durch z B Leitungsquerschnitte Absicherungen Schutzleiteranbindung Zu s tzliche Hinweise enth lt die Dokumentation Die Dokumentation enth lt Hinweise f r die EMV gerechte Installation Schir mung Erdung Anordnung von Filtern und Verlegung der Leitungen Beachten Sie diese Hinweise ebenso bei CE gekennzeichneten Antriebsstellern Der Her steller der Anlage oder Maschine ist verantwortlich f r die Ein
21. additional use of a potentiometer terminals 7 8 9 or dancer potentiometer terminals 12 13 master voltage terminals 7 8 14 10 11 64 Turn the trimmers Umax Umin T nzer Dancer to the left stop Set the setpoint potentiometer or master voltage to zero Switch on the mains and close switch RFR Adjustment ofthe minimum voltage Increase the motor speed by turning trimmer Umin clockwise until the required minimum torque is set If zero is required asthe minimum torque turn trimmer Umin back until the motor just ceases to rotate to avoid a dead band on the setpoint potentiometer in the bottom range Adjustment of the maximum voltage Set the setpoint potentiometer to maximum or set master voltage to U 10V Increase the motor torque by turning the trimmer Umax clockwise until the required maximum torque is set The setting for the minimum torque is to be checked because the minimum and maximum voltage can affect each other Set the setpoint potentiometer to the middle position or set master voltage to approx 5 V Using the trimmer T nzer Dancer set the required effect of the dancer potentiometer Position E reduces the motor voltage Position A increases the motor voltage After the adjustment of the effect of the dancer repeat the adjustment of the minimum voltage see step 4 with the dancer potentiometer in position E
22. complies with applicable EU directives and is suitable for use in CE compliant drive systems The following features and properties of this voltage controller make safe and reliable motor operation possible A Compact two printed circuit board device with electrically floating cooling plate B Large setting range for the output voltage up to full mains voltage C Not necessary to connect the star point or star neutral conductor for setting ranges up to 1 20 D For winding applications there is a second setpoint input for connecting a dancer potentiometer E Two mains voltage ranges can be selected by simple reconfiguration F Limited short circuit protection Degree of protection IP 00 Note gt In the operating instructions the voltage controllers are referred to as drive controllers gt Cross references within the operating instructions are marked with EDB712 DE EN 2 1 Lenze 41 2 1 42 Safety instructions General safety instructions and application notes for Lenze drive controllers Safety instructions General safety instructions and application notes for Lenze drive controllers as per Low voltage directive 2006 95 EC General Lenze drive controllers voltage controllers and associated components can have depending on their degree of protection live parts or moving or rotating parts when in operation Surfaces may be hot On incorrect removal of the necessary cover on improper use on incorrect installa
23. d large area connections if you use several mounting plates gt Connect the shields correctly EDB712 DE EN 2 1 Lenze 55 5 Electrical installation EMC compliant installation Installation of a CE typical drive system Axx_012 Fig 2 Large area shield connection A Shielded cable B Bare metal mounting areas a Braid D Earthing clamp gt When laying cables lay motor cable separately from signal and mains cables gt Connect the mains input and motor output to separate terminal strips gt Lay the cables as close as possible to the reference potential Suspended cables act like antennas If you use the drive systems with drive controllers in residential areas Check for compliance with the conducted interference levels in accordance with EN 55022 class B on the supply side in the building gt Check for permissible interference radiation in accordance with EN 55022 class B at the boundaries of the building Note Devices operated close to the drive controller that are not immune to interference in accordance with EN 55022 class B may be electromagnetically affected by the drive controller Only operate devices immune to interference in accordance with EN 55022 class B near the drive controller 56 Lenze EDB712 DE EN 2 1 Electrical installation 5 Connection plan Drive controller type 712 for mains connection 340 460 V 5 3 Connection pla
24. eb einer Wendeschitzschaltung zur Einleitung einer Drehfeldumkehr auftreten k nnen m ssen Sie zwischen den Ger teausgangsklemmen U W V W W U jeweils einen Zinkoxid Varistor S20K510 Art Nr 307 717 vorsehen Lenze CORRA 5 2 5 2 1 Elektrische Installation 5 EMV gerechte Installation Komponenten des CE typischen Antriebssystems EMV gerechte Installation Hinweis Der Weiterverwender ist f r die Einhaltung der EMV Richtlinie in der Maschinenanwendung verantwortlich Als Anwender erf llen Sie die EMV Richtlinie wenn Sie Kapitel 5 2 EMV ge rechte Installation bei der elektrischen Installation beachten Sie sind damit si cher dass Ihr Antriebssystem keine EMV Probleme verursacht Entsprechen alle Ger te und Anlagenteile der CE Anforderung hinsichlich der Storfestigkeit nach EN 50082 2 so sind keine elektromagnetischen Beeintr ch tigungen zu erwarten Komponenten des CE typischen Antriebssystems Hinweis Antriebssteller Funkentstorfilter und Netzdrossel befinden sich auf einer gemeinsamen Montageplatte Systemkomponente Spezifikation Antriebssteller Spannungssteller Funkentst rfilter m 34 Anker und Feldleitung Geschirmte Leistungsleitung mit verzinntem E CU Geflecht mit 85 optischer berdeckung Bewertete maximale L nge 50 m Netzleitung zwischen Funkentst rfilter und Ab Leitungslange 200 mm Netzdrossel sowie zwischen Netzdrosselund Geschirmte Leistungsleitung mit verzinntem E CU Antri
25. ebssteller Geflecht mit 85 optischer berdeckung Motorleitungen Geschirmte Signalleitung Typ LIYCY Motor Drehstrommotor mit Widerstandsl uferverhalten Lenze Typen reihe L12 10F4 10F8 F12 S4 1156 S8 F8 10F4 11MF4 oder hnlich EDB712 DE EN 2 1 Lenze 21 5 2 2 22 Elektrische Installation EMV gerechte Installation Installation des CE typischen Antriebssystem Installation des CE typischen Antriebssystem Hinweis Die EMV eines Antriebssystems ist installationsabh ngig Beachten Sie deshalb die Anweisungen zu Filterung Schirmung Erdung und Aufbau g A Hinweis Bei abweichender Installation z B gt Verwendung ungeschirmter Leitungen gt Verwendung von Sammelentst rfiltern anstelle der zugeordneten Funkentst rfilter ist f r die Bewertung der Konformit t zur CE EMV Richtlinie die berpr fung der Maschine oder Anlage auf Einhaltung der EMV Grenzwerte erforderlich Filterung Funkentst rfilter reduzieren hochfrequente St rgr en aufein zul ssiges Ma gt Verwenden Sie f r die Antriebssteller nur die zugeordneten Funkentst rfilter Die Auswahl eines geeigneten Funkentst rfilters ist abh ngig vom Laststrom Laststrom Bestellbezeichnung lt 8A EZF3_008A002 lt 10A EZF3_012A001 Nehmen Sie weitere Funkentst rma nahmen vor wenn die Motorleitungen l nger als 50 m sind Lenze EN Elektrische Installation 5 EMV gerechte Installation Installation des CE typisc
26. er Funkentst rfilter und Netzdrossel mit der geerdeten Montageplatte Der Einsatz elektrisch leitender Montageplatten z B verzinkt gew hrleisten einen dauerhaft sicheren Kontakt Entfernen Sie den Lack von den Montagefl chen wenn Sie lackierte Montageplatten verwenden gt Verbinden Sie Montageplatten z B mit Kupferb ndern gro fl chig leitend miteinander wenn Sie mehrere Montageplatten verwenden gt Legen Sie die Schirme richtig auf EDB712 DE EN 2 1 Lenze 23 5 Elektrische Installation EMV gerechte Installation Installation des CE typischen Antriebssystem Axx_012 Abb 2 Gro fl chige Schirmverbindung A abgeschirmte Leitung B metallisch blanke Montagefl che Cc Schirmgeflecht DI Erdungsschelle gt Trennen Sie beim Verlegen die Motorleitung von Signal und Netzleitungen gt Klemmen Sie Netzeingang und Motorausgang auf getrennte Klemmleisten F hren Sie die Leitungen m glichst dicht am Bezugspotenzial Frei schwebende Leitungen wirken wie Antennen Wenn Sie Antriebssysteme mit Antriebsstellern in Wohngebieten einsetzen gt berpr fen Sie die Einhaltung der Funkst rspannungspegel nach EN 55022 Klasse B an der Einspeiseseite der Betriebsst tte gt berpr fen Sie die zul ssige Funkst rstrahlung nach EN 55022 Klasse B an den Grenzen der Betriebsst tte Hinweis In der N he der Antriebssteller betriebene Ger
27. g of the field you must connect a zinc oxide varistor S20K510 art no 307 717 between each of the device output terminals U W V W and W U Lenze EN 5 2 5 2 1 Electrical installation 5 EMC compliant installation Components in a CE typical drive system EMC compliant installation Note The user is responsible for compliance with the EMC directive in the machine application As a user you are compliant with the EMC directive if you follow the chapter 5 2 EMC compliant installation during the electrical installation In this way you can be sure your drive system will not cause any EMC problems If all devices and system components comply with the CE requirement for interference immunity in accordance with EN 50082 2 no electromagnetic degradation is to be expected Components in a CE typical drive system Note Drive controller RFI filter and mains choke are on a common mounting plate System components Specification Drive controller Voltage controller RFI filter D 66 Armature and field cable Shielded power cable with tin plated E CU braid with 85 visual coverage Evaluated maximum length 50 m Mains cable between RFI filter and mains From cable length 200 mm choke as well as between mains choke and Shielded power cable with tin plated E CU braid drive controller with 85 visual coverage Motor cables Shielded signal cable type LIYCY Motor Three phase AC motor with resistive rotor behaviour Lenze
28. haltung der im Zu sammenhang mit der EMV Gesetzgebung geforderten Grenzwerte Um dieam Einbauort geltenden Grenzwerte f r Funkst raussendungen einzuhalten m s sen Sie die Antriebssteller in Geh use z B Schaltschr nke einbauen Die Ge h use m ssen einen EMV gerechten Aufbau erm glichen Achten Sie beson ders darauf dass z B Schaltschrankt ren m glichst umlaufend metallisch mit dem Geh use verbunden sind ffnungen oder Durchbr che durch das Ge h use auf ein Minimum reduzieren Lenze Antriebssteller k nnen einen Gleichstrom im Schutzleiter verursachen Wird f r den Schutz bei einer direkten oder indirekten Ber hrung ein Differenz stromger t RCD verwendet ist auf der Stromversorgungsseite des Antriebs stellers nur ein Differenzstromger t RCD vom Typ B zul ssig Anderenfalls muss eine andere Schutzma nahme angewendet werden wie z B Trennung von der Umgebung durch doppelte oder verst rkte Isolierung oder Trennung vom Versorgungsnetz durch einen Transformator EDB712 DE EN 2 1 Lenze 11 12 Sicherheitshinweise Allgemeine Sicherheits und Anwendungshinweise f r Lenze Antriebssteller Betrieb Sie missen Anlagen mit eingebauten Antriebsstellern ggf mit zusatzlichen berwachungs und Schutzeinrichtungen gem den jeweils g ltigen Sicher heitsbestimmungen ausr sten z B Gesetz ber technische Arbeitsmittel Un fallverh tungsvorschriften Sie d rfen die Antriebssteller an Ihre Anwendung anpassen
29. hen Antriebssystem Schirmung gt Schirmen Sie alle Leitungen zum und vom Antriebssteller ab Verbinden Sie den Schirm der Motorleitung nahe dem Antriebssteller gro fl chig mit der Montageplatte Verwenden Sie dabei Erdungsschellen auf metallisch blanken Montagefl chen Verbinden Sie die Schirme angeschlossener Leitungen von Sch tzen Motorschutzschalter oder Klemmen die sich in der Motorleitung befinden zus tzlich gro fl chig mit der Montageplatte Verbinden Sie im Motorklemmkasten den Schirm und das Motorgeh use gro fl chig mittels einer metallischen Kabelverschraubung Schirme analoger Steuerleitungen einseitig auflegen Verbinden Sie den Schirm der Steuerleitungen beidseitig gro fl chig mit der Montageplatte Wenn die Netzleitung zwischen Funkentst rfilter und Antriebssteller zusam men l nger als 300 mm ist gt Schirmen Sie die Netzleitungen ab gt Verbinden Sie den Schirm der Netzleitungen an den Leitungsenden beidseitig gro fl chig mit der Montageplatte Erdung Antriebssteller und Funkentst rfilter sind metallisch leitf hig und m ssen ge erdet werden gt Verbinden Sie alle metallisch leitf higen Komponenten mit einem zentralen Erdungspunkt gt Verwenden Sie bei der Verdrahtung die Mindestquerschnitte nach den Sicherheitsvorschriften Aufbau Hinweis F r die EMV ist nicht der Leitungsquerschnitt entscheidend sondern die Gr e der Kontaktfl che von Antriebsstell
30. hfolgend Antriebssteller genannt gt Querverweise innerhalb der Betriebsanleitung sind gekennzeichnet mit EI EDB712 DE EN 2 1 Lenze 9 2 1 10 Sicherheitshinweise Allgemeine Sicherheits und Anwendungshinweise fir Lenze Antriebssteller Sicherheitshinweise Allgemeine Sicherheits und Anwendungshinweise fiir Lenze Antriebssteller gem Niederspannungsrichtlinie 2006 95 EG Allgemein Lenze Antriebssteller Spannungssteller und zugeh rige Komponenten k n nen w hrend des Betriebs ihrer Schutzart entsprechend spannungsf hrende auch bewegliche oder rotierende Teile haben Oberfl chen k nnen hei sein Bei unzul ssigem Entfernen der erforderlichen Abdeckung bei unsachgem Bem Einsatz bei falscher Installation oder Bedienung besteht die Gefahr von schweren Personen oder Sachsch den Weitere Informationen entnehmen Sie der Dokumentation Alle Arbeiten zum Transport zur Installation zur Inbetriebnahme und zur In standhaltung darf nur qualifiziertes Fachpersonal ausf hren IEC 364 bzw CE NELEC HD 384 oder DIN VDE 0100 und IEC Report 664 oder DIN VDE 0110 und nationale Unfallverh tungsvorschriften beachten Qualifiziertes Fachpersonal im Sinne dieser grunds tzlichen Sicherheitshin weise sind Personen die mit Aufstellung Montage Inbetriebsetzung und Be trieb des Produkts vertraut sind und die ber die ihrer T tigkeit entsprechenden Qualifikationen verf gen Bestimmungsgem e Verwendung A
31. ie die defekte Sicherung ausschlie lich gegen den vorgeschriebenen Typ 34 6 Montieren Sie nach dem Sicherungswechsel wieder die Schutzabdeckung 7 Schalten Sie die Anlage wieder ans Netz EDB712 DE EN 2 1 Lenze 33 8 1 34 Anhang Zubeh r Anhang Zubeh r Zur Erg nzung von Antriebsstellern des Typs 712 E k nnen Sie folgendes Zube hor gesondert bestellen gt Funkentst rfilter Leistungssicherungen Sicherungshalter vvvvyv Antriebssteller Funkentstorfilter Leistungssicherungen Sicherungshalter Drehknopf Skala Zinkoxid Varistor Austauschwiderstand f r Betrieb mit Mittelpunktleiter Pos R420 Widerst nde f r Umstellung des Netzspannungsbereichs Pos R101 R103 Drehknopf und Skala f r Sollwertpotentiometer Austauschwiderstand fiir Betrieb mit angeschlossenem Mittelpunktleiter Zinkoxid Varistor nur bei Betrieb mit einer Wendeschitzschaltung Anzahl Typ 1 f r Laststrom lt 8 A fur Laststrom lt 10 A 3 FF 16A 6 3 x 32 mm superflink 1 3 polig 1 s 1 2er Teilung 3 S20K510 1 100 kQ 3 220 kQ 0 5 W Lenze Art Nr EZF3_008A002 EZF3_012A001 305 725 330 269 308 273 308 274 307 717 324673 auf Anfrage EDB712 DE EN 2 1 EDB712 DE EN 2 1 Lenze Anhang Zubeh r 35 Elements Part identifier Part designation Positions R101 R103 for changing mains Electronic fuse Power terminals Control terminals Trimmers for Umax Umin and UT nzer Dancer
32. ions e g cable cross sections fusing protective earth connection The documentation contains additional instructions The documentation contains instructions for EMC compliant installation shielding earthing layout of filters and laying cables Also follow these instructions for CE marked drive controllers The manufacturer of the system or the machine is responsible for compliance with the limits in relation to EMC law To comply with the limits for radiated emissions in the place the device is installed the drive controller must be installed in a housing e g control cabinet The housing must facilitate an EMC compliant layout Pay particular attention e g that switch cabinet doors are connected metallically to the housing all round if possible Openings or break outs on the housing are to be reduced to a minimum Lenze drive controllers can cause DC currents in the PE conductor If a residual current device RCD is used for protection against direct or indirect physical contact only a residual current device RCD of type B is allowed on the power supply side of the drive controller Otherwise a different protective measure must be used e g isolation from the surroundings using double insulation or reinforced insulation or isolation from the supply system using a transformer EDB712 DE EN 2 1 Lenze 43 44 Safety instructions General safety instructions and application notes for Lenze drive controllers Operation You m
33. n 5 3 1 Drive controller type 712 for mains connection 340 460 V PE L1 L2 L3 712_002 Fig 3 Connection drive controller 712 for mains connection 340 460 V gt The device is set in the factory to a mains voltage range of 340 460 V 0 The device can be changed to the mains voltage range 190 265 V 0 mp 26 EDB712 DE EN 2 1 Lenze 57 5 3 2 58 Electrical installation Connection plan Drive controller type 712 for mains connection 190 265 V Drive controller type 712 for mains connection 190 265 V A Fig 4 Note The drive controller 712 is set in the factory for operation with 340 460 V For operation with 190 265 V a soldered jumper must be changed and three 220 kQ 0 5 W resistors soldered in positions R101 R102 and R103 Danger Only appropriately skilled personnel are allowed to make the modification for operation on 190 265 V 240 V 712_003 Modification of the drive controller 712 for 190 265 V mains connection by changing soldered jumpers 1 Remove protective cover over the device printed circuit board if necessary 2 Move the soldered jumper from the soldering terminal 400 V to the soldering terminal 240 V by soldering Lenze EDB712 DE EN 2 1 Electrical installation 5 Connection plan Drive controller type 712 for mains connection 190 265 V 712_004 Fig 5 Modification of the drive controller 712 to 190 265 V mains connection
34. nd Anwendungshinweise f r 5 2 5 3 5 3 1 Antriebssteller Typ 712 f r Netzanschluss 340 460V 25 5 3 2 Antriebssteller Typ 712 f r Netzanschluss 190 265V 26 5 3 3 Anschluss von Steuersignalen an den Antriebssteller 712 29 EDB712 DE EN 2 1 Lenze 7 i Inhalt 8 Lenze EDB712 DE EN 2 1 Vorwort und Allgemeines 1 1 Vorwort und Allgemeines Mit dem Spannungssteller 712 lassen sich Drehstromasynchronmotoren mit Wi derstandsl uferverhalten bis zu einer Leistung von 3 3 kVA stufenlos im Dreh moment stellen Das Drehmoment wird beeinflusst ber eine Ver nderung des Schlupfes durch Phasenanschnittsteuerung der St nderspannung Dieser Spannungssteller stimmt mit geltenden EG Richtlinien berein und ei gnet sich zum Aufbau von CE konformen Antriebssystemen Folgende Ausstattungsmerkmale und Eigenschaften dieses Spannungsstellers erm glichen einen sicheren und st rungsfreien Motorantrieb A Kompaktes Zweiplatinenger t mit potenzialfreier K hlplatte B Gro er Stellbereich der Ausgangsspannung bis zur vollen Netzspannung C Anschluss des Mittelpunkt oder Sternpunktleiters f r Stellbereiche bis 1 20 nicht erforderlich D F r Wickelanwendungen ist ein zweiter Sollwerteingang zum Anschluss eines T nzerpotentiometers vorhanden E Durch einfache Umbest ckung zwei Netzspannungsbereiche w hlbar F Bedingt kurzschlussfest Schutzart IP 00 Hinweis gt In der Betriebsanleitung werden die Spannungssteller nac
35. nt potentiometer Replacement resistor for operation with neutral conductor connected Zinc oxide varistor only on operation with a reversing contactor circuit Quantity Type Art no 1 For load current lt 8 A EZF3_008A002 For load current lt 10 A EZF3_012A001 3 FF 16A 6 3 x 32 mm 305 725 super fast 1 3 pole 330 269 1 308 273 1 Graduations every 2 308 274 3 S20K510 307 717 1 100 kQ 324673 3 220 kQ 0 5 W On request Lenze EDB712 DE EN 2 1 EDB712 DE EN 2 1 Lenze Appendix Accessories 8 67 NED 03 2010 Lenze Automation GmbH Hans Lenze Str 1 D 31855 Aerzen Germany 49 0 51 54 82 0 49 0 51 54 82 28 00 Lenze Lenze de www Lenze com Service 10 CE Lenze Service GmbH Breslauer Stra e 3 D 32699 Extertal Germany 00 80 00 24 4 68 77 24h helpline 49 0 51 54 82 1112 Service Lenze de EDB712 a 13283222 a DE EN 2 1 a TDOO 8 7 6 5 4 3 2 1
36. ntriebssteller sind Komponenten die zum Einbau in elektrische Anlagen oder Maschinen bestimmt sind Sie sind keine Haushaltsger te sondern als Kompo nenten ausschlie lich f r die Verwendung zur gewerblichen Nutzung bzw pro fessionellen Nutzung im Sinne der EN 61000 3 2 bestimmt Bei Einbau der Antriebssteller in Maschinen ist die Inbetriebnahme d h die Aufnahme des bestimmungsgem en Betriebs solange untersagt bis festge stellt wurde dass die Maschine den Bestimmungen der EG Richtli nie 2006 42 EG Maschinenrichtlinie entspricht EN 60204 beachten Die Inbetriebnahme d h die Aufnahme des bestimmungsgem en Betriebs ist nur bei Einhaltung der EMV Richtlinie 2004 108 EG erlaubt Die Antriebssteller erf llen die Anforderungen der Niederspannungsrichtlinie 2006 95 EG Die harmonisierte Norm EN 61800 5 1 wird f r die Antriebssteller angewendet Die technischen Daten und die Angaben zu Anschlussbedingungen entnehmen Sie dem Leistungsschild und der Dokumentation Halten Sie diese unbedingt ein Warnung Die Antriebssteller sind Produkte dienach EN 61800 3 in Antriebssy steme der Kategorie C2 eingesetzt werden k nnen Diese Produkte k nnen im Wohnbereich Funkst rungen verursachen In diesem Fall kann es f r den Betrei ber erforderlich sein entsprechende Ma nahmen durchzuf hren Lenze ER Sicherheitshinweise 2 Allgemeine Sicherheits und Anwendungshinweise f r Lenze Antriebssteller Transport Einlagerung Be
37. s For technical data and information on supply conditions refer to the nameplate and the documentation It is imperative you comply with these data Warning The drive controllers are products that in accordance with EN 61800 3 can be used in drive systems of category C2 These products can cause interference in the residential area In this case it may be necessary for the operating organisation to take appropriate measures Lenze ER Safety instructions 2 General safety instructions and application notes for Lenze drive controllers Transport storage Follow the instructions on transport storage and correct handling Observe the climatic conditions see if necessary chapter Technical data Installation You must install and cool the drive controller in accordance with the regulations in the related documentation Ensure the device is handled carefully and avoid mechanical overload Do not bend components during transport and handling or change isolation distances Do not touch any electronic components or contacts Drive controllers contain electrostatic sensitive devices that can easily be damaged in case of improper handling Do not damage or destroy any electrical components as you may harm your health in the process Electrical connection When working on live drive controllers observe applicable health and safety regulations e g VBG 4 Undertake electrical installation in accordance with the applicable regulat
38. tfernt sein Verhindern Sie unbeabsichtigtes Ber hren spannungsf hrender Teile wenn Sie diesen Mindestabstand konstruktionsbedingt unterschreiten gt Montieren Sie eine geeignete Abdeckung die unbeabsichtigtes Ber hren der Ger teplatine ausschlie t Lenze EN 5 5 1 5 1 1 5 1 2 Elektrische Installation 5 Wichtige Hinweise FI Schutzschalter Elektrische Installation Wichtige Hinweise FI Schutzschalter AN Gefahr Gef hrliche elektrische Spannung Antriebssteller dieser Baureihe verf gen ber einen internen Netzgleichrichter Nach einem K rperschluss kann deshalb ein Fehlergleichstrom die Fehlerstromausl sung blockieren Um das zu verhindern treffen Sie folgende Ma nahmen gt Nullen Sie die Anlage oder verwenden Sie allstromsensitive Fl Schutzschalter Betriebsm ig auftretende kapazitive Ausgleichsstr me der Leitungsschirme und der Entst rfilter k nnen zu einer Fehlausl sung beim Fl Schutzschalter f hren Stellen Sie den Ausl sestrom des Fl Schutzschalter so hoch ein dass eine Fehlausl sung nicht m glich ist Hinweis Allstromsensitive Fl Schutzschalter werden in den Normen DIN EN 61800 5 1 und IEC 755 beschrieben Elektrostatische Gef hrdung Stop Elektrostatische Gef hrdung Antriebssteller dieser Baureihe enthalten elektrostatisch gef hrdete Bauelemente Vor Arbeiten am Antriebssteller muss sich das Servicepersonal elektrostatisch entladen gt Ber hren Sie die P
39. tion or incorrect operation there is a risk of serious injury or damage You will find further information in the documentation All work on transport installation commissioning and servicing is only allowed to be undertaken by appropriately skilled personnel IEC 364 and CENELEC HD 384 or DIN VDE 0100 and IEC Report 664 or DIN VDE 0110 and national health and safety regulations Appropriately skilled personnel in the context of these basic safety instructions are people who are familiar with the installation mounting commissioning and operation of the product and who have qualifications to suit their task Application as directed Drive controllers are components that are intended to be installed in electrical systems or machines They are not household appliances they are components that are only intended for industrial use or professional use in the context of EN 61000 3 2 On the installation of the drive controllers in machines commissioning i e commencing operation as directed is forbidden until it has been determined that the machine complies with the stipulations of the EU directive 2006 42 EC Machinery directive observe EN 60204 Commissioning i e commencing operation as directed is only allowed in case of compliance with the EMC directive 2004 108 EC The drive controllers comply with the requirements of the Low voltage directive 2006 95 EC The harmonised standard EN 61800 5 1 is applied to the drive controller
40. ulse and the drive controller are reset EDB712 DE EN 2 1 Lenze 61 5 Electrical installation Connection plan Expansion of the torque setting range 5 3 4 Expansion of the torque setting range As supplied the device is setup foroperation without a neutral conductor Inthis case the torque setting range is approx 1 20 If a larger setting range is required two measures must be taken gt Connect the neutral conductor to the motor star point gt Replace the resistor on soldering terminals position R420 fitted with 22 kQ resistor from the factory with a 100 kQ resistor 712_006 Fig 8 Replacing the 22kQ resistor with a 100 kQ resistor at position R420 62 Lenze EDB712 DE EN 2 1 Commissioning 6 Important notes 6 Commissioning 6 1 Important notes IN Danger A EDB712 DE EN 2 1 Dangerous electrical voltage Commissioning is only allowed to be undertaken by qualified skilled personnel using insulated tools Danger Damage to the drive controller on field reversal if motor is still running Under no circumstances is field reversal allowed to be activated with the controller enabled and the motor rotating Possible consequences gt Damage to the drive controller Protective measures gt Activate drive controller inhibit gt Wait until motor is at standstill Lenze 63 6 Commissioning Initial commissioning 6 2 Initial commissioning Step Adjustment for setpoint selection using Further adjustment on
41. ung 1 Entfernen Sie ggf eine Schutzabdeckung ber der Ger teplatine 2 Setzen Sie die L tbr cke vom L tst tzpunkt 400 V auf den L tst tzpunkt 240 V durch L ten um 26 Lenze EDB712 DE EN 2 1 Elektrische Installation 5 Anschlussplan Antriebssteller Typ 712 f r Netzanschluss 190 265 V 712_004 Umstellung des Antriebsstellers 712 auf Netzanschluss 190 265 V durch Einl ten von 220 kQ Widerstanden L ten Sie drei Widerst nde 220 kQ 0 5 W an den vorgesehenen Best ckungspl tzen R101 R102 und R103 ein 4 Montieren Sie ggf die Schutzabdeckung ber der Ger teplatine Abb 5 3 Lenze EDB712 DE EN 2 1 27 5 Elektrische Installation Anschlussplan Antriebssteller Typ 712 f r Netzanschluss 190 265 V PE L1 L2 L3 712_001 Abb 6 Anschluss Antriebssteller 712 f r Netzanschluss 190 265 V 28 Lenze EDB712 DE EN 2 1 Elektrische Installation 5 Anschlussplan Anschluss von Steuersignalen an den Antriebssteller 712 5 3 3 Anschluss von Steuersignalen an den Antriebssteller 712 PTs Te el e up ola RFR Stellerfreigabe Leitspannung Uy 10V 712_005 Abb 7 Anschluss von Sollwertsignalen und der Stellerfreigabe Das Ger t kann ber die Klemmen 7 8 und 9 ein Sollwertsignal per Potenziometer oder Leitspannung auswerten Zus tzlich kann f r Wickelanwendungen ein zweiter Sollwert an den Klemmen 12 13 und 14 ber ein T nzerpotenziometer vorgegeben werden
42. uses must be at least 250 mm from the drive controller Prevent unintentional physical contact with live parts if you do not comply with this minimum distance Fita suitable cover that prevents unintentional physical contact Lenze EN Electrical installation 5 Important notes Earth leakage circuit breaker 5 Electrical installation 5 1 Important notes 5 1 1 Earth leakage circuit breaker IN Danger Dangerous electrical voltage Drive controllers in this series have an internal mains rectifier For this reason after a short circuit to frame a DC leakage current can block the leakage current tripping To prevent this situation take the following measures gt Connect the system to neutral or use an earth leakage circuit breaker of universal current sensitivity Capacitive compensation currents occurring in the cable shield and interference filter under normal operating conditions can cause the earth leakage circuit breaker to trigger incorrectly gt Set the trigger current on the earth leakage circuit breaker sufficiently high that incorrect triggering is not possible Note Earth leakage circuit breakers of universal current sensitivity are described in the standards DIN EN 61800 5 1 and IEC 755 5 1 2 Electrostatic hazard Stop Electrostatic hazard Drive controllers in this series contain electrostatic sensitive devices Prior to working on the drive controller service personnel must discharge themselves
43. ust equip the drive controllers installed with additional monitoring equipment and protective equipment as per the applicable safety stipulations if necessary e g law on technical equipment health and safety regulations You are allowed to adapt the drive controller to your application Pay attention to the instructions in the documentation during this process It is not allowed to touch live components or power terminals immediately after isolating the drive controller from the supply voltage as capacitors may be charged Pay attention to the related labels on the drive controller Keep all protective covers and doors closed during operation Note for UL approved systems with built in drive controllers UL warnings are instructions that only apply to UL systems The documentation includes special instructions for UL Maintenance and servicing The drive controllers are maintenance free on compliance with the stipulated operating conditions In case of dirt laden ambient air the cooling surfaces on the drive controller may become soiled or cooling openings clogged For this reason in these operating conditions regularly clean the cooling surfaces and cooling openings Never use sharp or pointed objects for this task Disposal Send metals and plastics for recycling Properly dispose of populated printed circuit boards It is imperative you follow the product specific safety instructions and application notes in these instructions