Home
INSTALLATION MANUAL
Contents
1. el OFF a Replacement of Air Purifying Filter NOTE Air purifying filter is optional part 1 Open the Inlet Grille Prop up the inlet grille by using a small device named grille support which located in the right side of the indoor unit 2 Detach the standard air filter Slide the knob slightly upward to release the filter then withdraw it 3 Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames Remote Controller Indoor Body wipe the air conditioner by using a soft and dry cloth For serious stains use a neutral detergent diluted with Do not usewater wipe the controller water Wring the water out of the with a dry cloth Do not use glass cloth before wiping then wipe off the cleaner or chemical cloth detergent completely Do not use the following for cleaning Gasoline benzine thinner or cleanser Hot water over 40 C 104 F may damage the coating of the unit cause discoloring or deformation Air Fi
2. Do not start or stop the Do not channel the air flow directly Do not try to repair or Come eea operation by disconnecting at people especially at infants or reconstruct by yourself er the power supply cord the aged aA and so on s ee Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with food art work precise equipment when gas appliance is running at the wet hand breeding or cultivation same time Fa SL 8 Nel ili Se STRICT oP PROHIBITION ENFORCEMENT PROHIBITION Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit or other heating apparatus installation stand for cleaning EEA x j EEN _ 0p MTT Ty ATTN LNT ET ZE MHH y Fi oe PROHIBITION PROHIBITION aaa PROHIBITION Do not place animals or plants in Do not place any objects on or Do not place flower vase or water the direct path of the air flow climb on the unit containers on the top of the unit ES g J PROHIBITION HUN PROHIBITION PROHIBITION EE ST PA D Trouble shooting Before asking for service check the following first Cause or check points The system does not restart immediately Noise is heard Normal Performance inspection
3. Loading of the battery 1 Remove the battery cover 2 Load the batteries as illustrated 2 R 03 batteries resetting key cylinder 3Be sure that the loading is in line with the 4 Load the battery then put on the cover saci Note The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well When electronic started type fluorescent lamp or change over wireless telephone is installed in the type fluorescent lamp or room the receiver is apt to be disturbed in receivingthe signals so the distance to the Indoor unit should be shorter Full display or unclear display during operation Indicates the batteries have been used up Please change batteries If the remote controller can t run normally during operation please remove the batteries and reload several minutes later Hint Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Operation Mi Base Operation Remote controller 25 HEALTH AIRFLOW cocos 1 Unit start Press ON OFF on the remote controller unit starts 2 Select operation mode Press MODE button For each press operation mode changes as follows Remote controller Pea ae oe ee AUTO COOL DRY FAN HEAT 3 Select temp setting Press TEMP TEMP button TEMP Every time the button is pressed temp setting increase 1
4. Cooling only unit do not have displays and functions related with heating W Healthy airflow Operation 1 Press ON OFF to starting Setting the comf ort work conditions 2 The setting of healthy airflow function 1 Press the button of healthy airflow appears on the display Horizontal airflow sending Avoid the airflow blows direct to the body 2 Press the button of healthy airflow again appears on the display Downward airflow sending Avoid the airflow blows direct to the body 3 The cancel of the healthy airflow function Press the button of healthy airflow again the unit goes on working under the condition before the setting of healthy airflow function Notice Do not direct the flap by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller Note 1 After setting the healthy airflow function the position grill is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using the air conditioner for a long time under the high air humidity condensate water may occur at the grille Operation W Timer On Off On Off Operation Set clock correctly before starting TIMER operation 1 After unit starts select your desired operation mode 2 Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote co
5. Smells are generated Mist or steam are blown out In dry mode fan speed can t be changed Multiple check e When unit is stopped it won t restart immediately until 3 minutes have elapsed to protect the system e When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner e During unit operation or at stop a swishing or gurgling noise may be heard At first 2 3 minutes after unit start this noise is more noticeable This noise is generated by refrigerant flowing in the system e During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes e Should there be a big noise from air flow in unit operation air filter may be too dirty e This is because the system circulates smells from the interior air such as the smell of furniture paint cigarettes e During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of indoor air e In DRY mode when room temperature becomes lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting e Is power plug inserted e Is there a power failure Is fuse blownout e Is the air filter dirty Normally it should be cleaned every 15 days e Are there any obstacles before inlet and outlet e Is temperature set correctly e Are there
6. INSTALLATION MANUAL ual YORK BY JOHNSON CONTROLS Mini Split Air Conditioner YLHJZHOO9 BARXAFX Read this manual before installation and operation Make sure that it is well kept for later reference j Johnson Controls Parts and Functions E Indoor Unit Horizontal flap adjust up and down air flow Inlet Inlet grille a eh sao Filter inside ean eee ben A flow Actual inlet grille may vary from the one shown in the manual according to the product purchased Display board o Remote signal receiver A beeping sound is generated when a signal from remote controller isreceived Power indicator Lights up when unit starts amp Timer mode indicator Lights up whenTimer operation is selected E Operation mode indicator lights up when the compressor is on Ambient temp display When receiving the remote control signal display the set temperature E Outdoor Unit O OUTLET 3 CONNECTING PIPING AND ELECTRICAL WIRING 2 INLET DRAIN HOSE BB Clock set Press CLOCK button AM or PM flashes Press TIME or Time to set correct time Each press will increase or decrease 1min If the button is kept pressed time will change quickly After time setting is confirmed press SET AM and PM stop flashing while clock starts working L J HEALTH A SLEEP AIRFLOW SWING y LOCK TIME SWING gt 35
7. 5 LIGHT LOCK CODE RESET N a Mi Remote controller 7 MODE button O YORK 8 ON OFF button 9 TIMER ON displa y D EEA 10 FAN SPEED display B cottrctll atl 11 a7 LOW MED AUTO D m 11 LOCK display nt 12 SWING display 13 SLEEP display HE Tewe 14 Operation mode display Fo S Tp Preme ol elelee core oma 15 Signal sending display Fine i Sail display O isplay 18 TIMER OFF display 19 CLOCK display 20 TEMP button 21 FAN SPEED button J 22 SWING button 1 o 23 HEALTH AIRFLOW button Used to select CODE AorB 24 POWER SOFT button which will be displayed on 29 SET button LCD Please select A without 26 LOCK button special explanation If pressed the other buttons 2 LIGHT button will be disabled Press it once Control the lightening and again lock will be cancelled extinguishing of the indoor 27 RESET button LED display board When the remote controller 3 TIMER button appears abnormal use a 4 CLOCK button sharp pointed article to press 5 SLEEP button this button to reset the remote 6 TIME button controller normal NOTE Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function follow it If not please ignore POWER SOFT button is not available for 07k O9k 12k
8. C if kept depressed it will increase rapidly TEMP Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection Press FAN SPEED button For each press fan speed changes as follows Remote controller ae vent coat att LOW MED HI AUTO Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature Operation Remote Display Mode Controller Board Under the mode of auto operation air conditioner will AUT gt automatically select Cool or Heat operation according MS NS Le Pj to room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed COOL according to room temperature EN In DRY mode when room temperature becomes DRY Ce lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting oe er te Of In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode SLEEP operation is not available Mi Emergency operation and test operation Emergency Operation e Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which
9. high condensate water might occur at air outlet if all vertical louvers are adjusted to left or right t is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode otherwise condensate water might occur Note When restart after remote turning off the remote controller will automatically memorize the previous set swing position Operation Mi Sleep Operation Before going to bed you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep is _ F lt anA Use of SLEEP function After the unit starts set the operation status then press SLEEP button before which the clock must be adjusted and time being set Operation Mode 1 In COOL DRY mode 1 hours after SLEEP mode starts temp will become 1 C higher than temp setting After another 1 hours temp rises by 1 C futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep SLEEP operation stops SLEEP operation starts Approx 6hrs Temp setting Unit stop In COOL DRY mode 2 In HEAT mode 1 hours after SLEEP mode starts temp will become 2 C lower than temp setting After another 1 hours temp decrease by 2 C futher After more another 3 hours temp rises by 1 C futher The unit will run for further 3 hours then stops Temp is lower than temp setting so that room temperature wont b
10. months The bacteria killing medium air purifying filter will be used for a long time no need for replacement But in the period of using them you should remove the dust frequently by using vacuum cleaner or flaping them lightly otherwise its performance will be affected e Please keep the bacteria killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced Cautions A WARNING Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage A WARNING When abnormality such as burnt small found Use an exclusive Check proper immediately stop the operation button and power source installation of the contact sales shop with a circuit drainage securely a breaker J Q iA y STRICT STRICT ENFORCEMENT ENFORCEMENT Connect power supply cord 1 Do not use power supply cord extended to the outlet completely or connected in halfway 2 Do not install in the place where there is any possibility of inflammable gas leakage around the unit 3 Do not get the unit exposed STRICT STRICT to vapor or oil steam ENFORCEMENT ENFORCEMENT PROHIBITION Do not use power supply Take care not to damage Do not insert objects into the air cord in a bundle the power supply cord inlet or outlet
11. of outdoor unit is broken change it with the type of T 25A 250V 4 The wiring method should be in line with the local wiring standard 5 After installation the power plug should be easily reached 6 The waste battery should be disposed properly 7 The appliance is not intended for use by young children or infirm persons without supervision 8 Young children should be supervised to ensure that they do not play with the appliance 9 Please employ the proper power plug which fit into the power supply cord 10 The power plug and connecting cable must have acquired the local attestation 11 In order to protect the units please turn off the A C first and at least 30 seconds later cutting off the power 10 Johnson Y Controls 2014 Johnson Controls Inc www johnsoncontrols com U1HJZHARZ 140113 Johnson Controls reserve the right to change product features without prior notice
12. some doors or windows left open e Is there any direct sunlight through the window during the cooling operation Use curtain e Are there too much heat sources or too many people in the room during cooling operation Cautions e Do not obstruct or cover the ventilation grille of the air conditoner Do not put fingers or any other things into the inlet outlet and swing louver e This appliance is not intended for use by persons including children with reduced physiced sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of appliance by person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Specifications e The refrigerating circuit is leak proof The machine is adaptive in following situation 1 Applicable ambient temperature range Maximum D B W B 32 C 23 C Indoor Minimum D B W B 21 C 15 C Cooling Maximum D B W B 46 C 26 C Outdoo Minimum D B 18 C Maximum D B 27 C Indoor Minimum D B 15 C Maximum D B W B 24 C 18 C Outdoor Minimum D B W B 7 C 8 C Outdoor Maximum D B W B 24 C 18 C INVERTER Minimum D B 15 C 2 If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 If the fuse of indoor unit on PC board is broken please change it with the type of T 3 15A 250V If the fuse
13. thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape Carry out based on the neighboring pillars or lintels a proper leveling for the plate to be fixed against the wall then temporarily fasten the plate 1 Take out cushion blocks on the left and right angle beads as shown in the following Figure 2 Remove 2 gaskets under the cross flow fan 3 Clean the burr on the surface of fracture i to avoid the power wire from being scratched after removing the virtual opening of the outgoing m 7 line slot on the case by A b fC 5 hands in indoor ae we ea i power on process NE a When the mounting plate is fixed side bar and lintel Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Refer to the previous article When the mounting plate is first fixed for the position of wall hole Making a Hole on the Wall and Fitting the Piping Hole Cover Make a hole of 70 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Wall hole 70mm Outdoor side Thickness of wall Section of wall hole G Piping hole pipe
14. 250VAC Indoor 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 A breaker should be incorporated into fixed wiring The breaker should be all pole switch and the distance between its two contacts should be not less than 3mm Communication fault between Indoor unit outdoor unit signal transmission error due to wiring indoor and outdoor error Faulty PCB Operation halt due to breaking of wire inside the fan motor Operation halt due to breaking of the fan motor lead wires Detection error due to faulty indoor unit PCB Indoor fan motor malfunction Power Source Installation The power source must be exclusively used for air conditioner in the case of installing an air conditioner in a moist place please install an earth leakage breaker For installation in other places use a circuit breaker as far as possible Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed 9 Check for Installation and Test Run E Please kindly explain to our customers how to operate through the instruction manual Check Items for Test Run Put check mark in boxes Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block Is the connecting wiring of indoor and outdoo
15. Connect beforehand the indoor outdoor electric cable and then pull out the connected to the heat insulation of connecting part specially Fixing the indoor unit body Hang surely the unit body onto the upper ia notches of the mounting plate Move the Oy y f from side to side to verify its secure fixing 4 f In order to fix the body onto the mounting lt plate hold up the body aslant from the underside and then put it down perpendicularly mounting plate Unloading of indoor unit body When you unload the indoor unit please use your hand to arise the body to leave agraffe then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate _ Connecting the indoor outdoor Electric Cable Removing the wiring cover indoor unit then take off wiring cover by removing FFT its screws p aoe Incorrect Correct When connecting the cable after installing the indoor unit i J Y Crack Partial Too outside 1 Insert from outside the room cable into left side of the wall Lean Damage of flare On Drainage Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop When connecting the cable before ins
16. Installation of the Indoor Unit Drawing of pipe Rear piping Draw pipes and the drain hose then fasten them with the adhesive tape Remove terminal cover at right bottom corner of Left e Left rear piping In case of left side piping cut away with a nipper the lid for left piping In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure fixing with adhesive tape Indoor outdoor electric cable Heat insulation material Piping F Lid for right Pipe supporting piping i plate Lid for left piping Drain hose Lid for under piping pipe Fix with adhesive tape indoor outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape Other direction piping Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole When bending be careful not to crash pipes
17. e electrical and electronic products DISPOSAL REQUIREMENTS Your air conditioning product is marked with this symbol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the air conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to prevent potential negative cons equences for the environment and humen health Please contact the installer or local authority for more information Battery must be removed from the remote controller and dis posed of separately in accordance with relevant local and nationi legislation IMPORTANT INFORMATION REGA RDING THE REFRIGERANT USED Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1 This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink e1 _ the factory refrigerant charge of the product e2 the additional refrigerant amount charged in the field and e 1 2 the total refrigerant charge on the refr
18. e too high for your sleep Temp setting Unit stop Decreases 2 C 3 hrs SLEEP SLEEP operation stops In HEAT mode 3 In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function operation starts 5 Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep set for lowing the wind speed after sleeping If it is low wind no change Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on E POWER SOFT Operation 1 POWER Operation When you need rapid heating or cooling you can use this function In COOL mode fan speed automatically takes high speed of AUTO fan mode In HEAT mode fan speed automatically takes medial speed of AUTO fan mode 2 SOFT Operation You can use this function when silence is needed for rest or reading In SOFT operation mode fan speed automatically takes low speed of AUTO fan mode Note During POWER operation in rapid HEAT or COOL mode the room will show inhomogeneous temperature distribution Long period SOFT operation will cause effect of not too cool or not too warm To cancel POWER or SOFT operation Press POWER SOFT button again ROWER or SOFT disappears NOTE
19. igerant charge label supplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover A contains fluorinated greenhouse gases covered by the Kyoto Protocol factory refrigerant charge of the product see unit name plate additional refrigerant amount charged in the field total refrigerant charge outdoor unit refrigerant cylinder and manifold for charging 1M O W Indoor Unit Installaion Necessary Tools for Installation Power Source Driver Torque wrench Before inserting power into receptacle check the voltage without Nipper 17mm 22mm 26mm fail Hacksaw Pipe Caner The power supply is the same as the corresponding nameplate Soe en ee oe Install an exclusive branch circuit of the power Spanner 17 19 and 26mm Knife 7 Gas leakage detector or Measuring tape A receptacle shall be set up in a distance where the power cable soap and water solution Reamer can be reached Do not extend the cable by cutting it selection of Installation Place Accessory Parts Remote controller 1 Drain hose 1 SS R 03 dry battery 2 amp Plastic cap 4 gt gt Place robust not causing vibration where the body can be supported sufficiently Place not affected by heat or steam generated in the vicinity where inlet and outlet of the unit are not disturbed 4X25 Screw 4 wm Place possible to drain easily whe
20. lter cleaning l 1 Open the inlet grille by pulling it upward 2 Remove the filter THE Push up the filter s center tab slightly until it is a released from the stopper and remove the filter downward 3 Clean the filter Use a vacuum cleaner to remove dust or wash the filter with water After washing dry the filter completely in the shade 4 Attach the filter Attach the filter correctly so that the FRONT indication is facing to the front Make sure that the filter is completely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects 5 Close the inlet grille 4 Attach the standard air filter Necessary installation ATTENTION The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white side face the unit 5 Close the Inlet Grille Close the Grille surely NOTE The photocatalyst air purifying filter will be solarized in fixed time In normal family it will be solarized every 6
21. means the start of this operation e In this operation the system automatically selects oz the operation modes cooling or fan or heat a according to the room temperature Room Operation Designated Timer temperature mode temperature mode rovere ooome o wo AUTOMATIC sowase wear ae wo AUTOMATIC cooling only Operation Designated Timer Room temperature mode temperature mode Air flow BELOW 23 C AUTOMATIC elt is not possible to operate in dry mode Air flow Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi WE Air Flow Direction Adjustment 1 Status display of air flow Vertical flap Pos 1 7 Pos 2 gt Pos 3 s Pos 4 Pos 5 Auto swing 2 Left and right air flow adjustment manual Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig Remote controller can memorize each operation status When starting it next time just press ON OFF button and unit will run in previous status Cautions When adjusting the flap by hand turn off the unit e When humidity is
22. ntroller gt edo Ag TIMER ON TIMER OFF o gt gt p BLANK a00 TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or TIMER ON OFF or aa will flash 3 Press TIME TIME button to set time It can be adjusted within 24 hours 4 After setting correct time press SET button to confirm 0 or i on the remote controller stops flashing 5 Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears Hints After replacing batteries or a power failure happens time setting should be reset Remote controller possesses memory function when use TIMER mode next time just press SET button after mode selecting if time setting is the same as previous one According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS CE All the products are in conformity with the following European provision Low Voltage Directive 2006 95 EC Electomagnetic CompatibilitY 2004 108 EC ROHS The products are fulfilled with the requirements in the directive 2011 65 EU of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment EU ROHS Directive WEEE In accordance with the directive 2012 19 EU of the European parliament herewith we inform the consumer about the dis posal requirements of th
23. r firmly fixed Is drainage securely carried out Is the earth line securely connected Is the indoor unit securely fixed Is power source voltage abided by the code Is there any noise Is the lamp normally lighting Are cooling and heating when in heat pump performed normally Is the operation of room temperature regulator normal After inserting the flare nut flaring work is carried out Flare tool for R410A Conventional flare tool Clutch type clutch type Rigid type Wing nut type Imperial type 1 0 1 5mm 1 5 2 0mm 1 Cut pipe 2 Remove burs D 4 Flare pipe Flare tooling die A 3 Insert the flare nut Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time turn off the power supply main switch
24. re piping can be conne Mounting plate 1 Air purifying filter Optional 1 cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space around Selection of Pipe Place where the distance of more than Im from televisions Liquid pipe 6 35x0 8mm radios wireless apparatuses and fluorescent lamps can be FOR 09K 12K Gas pipe 9 52x0 8mm left iquid pi i Liquid pipe 2 6 35x0 8mm in the case of fixing the remote controller on a wall place FOR 18K 42 7x0 8mm where the indoor unit can receive signals when the fluore ee scent lamps in the room are lightened FOR 24K Liquid pipe P 9 52x0 8mm Gas pipe P 15 88x1 0mm Drawing for the installation of indoor units The models adopt HFC free refrigerant R410A Attention must be paid to the rising up of drain hose more than 15cm Arrangement of piping directions gt Ak 2 CERN Rear left more than lt gt p Rear 10cm gt right gt Right Below more than 10cm The distance between the indoor unit and the floor should be more than 2m Please be subject to the actual product purchased the above picture is just for your reference Indoor Unit Installation Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed with one steel nail 2 Make sure once more the proper level of the plate by hanging a
25. talling the indoor unit Insert the cable from the back side of the unit then pull it out on the front side Loosen the screws and insert the cable ends fully into terminal block then tighten the screws Pull the cable slightly to make sure the cables have been properly inserted and y l Less than 5cm vl 7 Itbecomes The endisimm Itwaves The gap with the There is the bad high midway ersed in water ground is too small smell from a ditch tightened After the cable connection never fail to fasten the connected cable with the wiring cover Ilse ca Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail D On Drainage a g Faulty connector connection On or aure Faulty thermistor Indoor EEPROM Faulty EEPROM data Faulty EEPROM Haa Faulty PCB A C DEE Bege T To Outdoor unit Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 2 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is HO5RN F or HO7RN F 2 If the fuse on PC board is broken please change it with the type of units T 3 15A