Home
GSW3208M-3424M User Manual
Contents
1. Dy Addres 900 Spammug E VLAN c 06 3 C Teak DHCP Relay 4 12 This function is used to configure port settings of the switch You can enable disable a port set it to fixed 10M or 100M or 1000M and so on Auto Mode User can select the operation mode of port when auto is set to disabled For Auto Negotiation mode the switch will do port auto negotiation function ON OFF when the auto function of port in Port Configuration setting is enabled disabled For Auto Detect mode the switch will always keep port auto negotiation function ON but just modify its attribution if auto function of port in Port Configuration setting is disabled For applications you should select Auto Detect mode if the connected device is auto negotiation enabled For example customers PC is auto negotiation enable and you want to set his network connection to work at 10Mbps And you can select Auto Negotiation mode if the connected device is auto negotiation disabled it is called forced mode sometimes Some of old TX FX Converters needs to work in this mode because FX supports 100 Full forced mode only For most applications Auto Detect mode is OK 92 Port Setting It is for modifying the setting of port Follow the steps to do it 1 Select the port that you want to modify in first 2 Fill the name of the port 3 Select Enable Disable state in Admin If D
2. Enter exit command to go back to prompt Enter show ip interface to check the IP settings Enter show ip redirects to check IP gateway setting After IP address configuration done and the switch is connected to network users can start Http connection by entering IP address of the switch to the web address line in Web Browser login screen will be prompted for user name and password The default user name and password is admin admin Then the management homepage will appear 78 System Configuration Main Uoard Information Firmware Version 1 01 09 built at Aug 6 2000 14 30 24 Mac Address 00 00 06 64 99 6F CJ System HC SNMP Number of Ports 10 7 Security 1Q VLAN Max Group 56 Post I Addresses Table CJ Spanning 02 VLAN 2 Qos aG tome Tmk C Tools H Left part of the homepage is a function list Users can select one of them for status monitoring or switch configuration Upper part of the homepage is the link status of the switch Three different colors are used to show different status of ports Link Up Link Down and Port Disable Middle part of homepage is the main operation area for each function The details about management with http connection will be shown in the following sub sections 79 6 4 1 System System Information is the homepage of the switch And there are four sub functions for it 1 System Information
3. 00 CO F6 01 04 28 Learned show mac address table multicast command will show multicast address table for IGMP function For example show mac address table multicast Group VID Group Address Members Port 68 14 show mac security command This command is used to show mac address security settings on port There are two mac address security functions for ports One is accept function that allows static mac addresses on ports to access network only Another is limit by mac no function and up to a limit number of mac addresses are allowed to access network from the port For example show mac security MAC Security Configuration Port Max no Learned no Security Control Eth 1 1 0 N A No Security Eth 1 2 0 N A No Security Eth 1 3 0 N A No Security Eth 1 4 0 N A No Security Eth 1 5 10 0 Limited by MAC no Eth 1 6 0 N A No Security Eth 1 7 0 N A Accept function Eth 1 8 0 N A No Security Eth 1 9 0 N A No Security Eth 1 10 0 N A No Security 15 show management command This command is used to show switch management security settings The IP subnet access mode and protocol functions security settings will be shown For example show management Management IP configuration Index Enabled Address Net Mask Mode Http Telnet SNMP 1 Yes 0 0 0 0 0 0 0 0 Modify Yes Yes Yes 2 No 0 0 0 0 255 255 255 255 View No No No 3 0 0 0 0 255 255 255 255 View No No No 4 No 0 0 0 0 255 255 255 255 View No No No
4. Copies from one file to another 1 exit command This command is used to leave current operation mode It will do logout at this basic command interface 2 help command This is a help command and the console will prompt with all available commands 3 history command This command will show the history of entering commands 4 logout command This is a logout command 5 ping command User can use this command to ping another network device to verify the network connection and activity It is similar to the ping command in MS DOS Enter ping at the prompt the command syntax will be shown ping Syntax ping n count I length t w timeout ip 24 n count Number of echo requests to send length Send buffer size and length is between 64 8148 t Ping the specified host until stopped by lt ESC gt key Ww Timeout in milliseconds to wait for each reply ip IP address For example ping 192 168 1 80 Esc can be used to break continuous ping operation quit command This command is used to quit the console interface reload command This command is used to reset switch It will halt and perform a warm restart Enter reload at the prompt you will be asked to confirm the action reload Are you sure to reset switch now Y N If y is entered the switch will reboot If n is entered just leave and no any action will go show comm
5. E 8 IP Configuration S Time Configuration HQ Log 803 SNMP EC Security EC Port HH Addresses Table EC Spanning Tree VLAN EC Qos C IGMP 8009 Tank Eg Tools System Configuration Main Board Information Firmware Version Mac Address Number of Ports 1Q VLAN Max Group 1 04 14 00 00 06 64 99 6F 10 1024 This function lists the system information about the switch You can find the firmware version Mac address connection port number and maximum VLAN group number here 2 IP Configuration Home 23 System 8 System Information fg wcssgusiss 8 Time Configuration HG Log mg SNMP Security aE CC Addresses Table GB Spanning Tree mg FLAN aE 005 aE IGMP GC GQ Tools IP Setting Network Configuration DHCP Client IP Address Network Mask Gateway Management VLAN O Enable Disable 192 168 1 12 2552552550 192 168 1 254 Apply Note Community vlan and Isolated vlan can not be Management VLAN This function is used to setup IP configuration of the switch You can enable DHCP client function to get IP configuration from DHCP server 80 automatically Or disable DHCP client function and set IP configuration manually Management VLAN This is used to setup the VLAN ID for remote management interface of the switch Only users in the same VLAN can manage the switch remotely For example setting it to 5 will allow
6. VLAN and set the name description to the Port based VLAN is the index of the Port based VLAN is the name description for it 50 22 power saving command This command is used to enable the power saving function for the interface port s If it is enabled and auto negotiation is also enabled the interface port s will go to low power mode when link down That can reduce power consumption of the switch When link is detected ports will come back to normal working state automatically power saving command is used to enable the power saving function for the interface port s no power saving command is used to disable this function on the interface port s 23 qos command This command is used to set port based priority on the interface port s And enable 802 1P priority DSCP priority on the interface port s config if qos dscp enable IP DSCP priority port Port priority map precedence enable IP precedence priority qos dscp command is used to enable DSCP priority operation on the interface port s And no qos dscp command is used to disable it qos precedence command is used to enable 802 1P priority operation on the interface port s And no qos precedence command is used to disable it qos port x command is used to set port based priority on the interface port s is the priority queue and its value is 0 3 0 Low 1 Normal 2 Medium 3 High Note If DSCP priority 802 1P priority and
7. 16 show map command This command is used to show 802 1P priority DSCP priority and port based priority to priority queues mapping There are four priority queues on each port of the switch show map dscp IP DSCP priority map port IP port priority priority 802 1p priorities map show map dscp command is used to show IP DSCP QoS function 69 enable disable status and DSCP values 0 63 to priority queue mapping on each port show map dscp ethernet 1 x command is used to show DSCP values 0 63 to priority queues mapping on Port x x is the port number show map port command is used to show connection port to priority queues mapping This is called port based priority show map priority command is used to show 802 1P priority values 0 7 to priority queues mapping on each port show map priority ethernet 1 x command is used to show 802 1P priority values 0 7 to priority queues mapping on Port x is the port number 17 show mvr command This command is used to show MVR configuration show mvr command is used to show MVR VLAN setting one after another show mvr x command is used to show a MVR VLAN setting x is the VLAN ID For example show mvr 11 Active Yes Name MVLAN 11 802 1p Priority 0 Mode Dynamic Source Port Eth1 10 Receiver Port Eth1 5 Eth1 6 Eth1 7 MVR Group Configuration Name Start Address End Address abc 224 0 0 1 224 0 0 2 abcd 224 0 0 3 224 0 0 4 18 show port com
8. User Manual LE B GSW3208M 3424M L2 Managed GbE Switches union CTC UNION TECHNOLOGIES CO LTD CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park No 60 Zhouzi St Neihu District Taipei 114 Taiwan Tel 886 2 26591021 Fax 886 2 2799 1355 Email info ctcu com URL _ http www ctcu com GSW3208M 3424M User Manual 8 2 and 2444 Gigabit Ethernet Layer 2 Switches w SNMP Version 1 2 Feb 10 2010 Updated We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability quality or fitness for any particular purpose The information in this document is subject to change without notice We reserve the right to make revisions to this publication without obligation to notify any person or entity of any such changes Trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies About this manual This manual is a general manual for different models of our Gigabit Management Switch They are similar in operation but have different hardware configurations These models are 1 8 TX 2 SFP 10G ports model This model supports eight TX ports and two extra SFP ports for Gigabit Ethernet connections 2 24 TX 4 SFP 240 ports model This model supports twenty four TX ports and four share SFP ports Port 21 24 are 1000TX RJ45 port SFP port optional for Gig
9. snmp server community set xxx command is used to set the community string of set command for SNMP operation is the community string snmp server contact xxx command is used to set the contact information for this switch xxx is the contact information string snmp server location xxx command is used to set the location information for this switch is the location information string snmp server version x command is used to select the SNMP operation version X could be v1 v2c v3 v3v2c v3v2cv1 The following commands are for SNMPv3 function snmp server username xxx securitylevel y command is used set security level of user xxx xxx is the user name y could be noauth auth or priv noauth no authentication no encryption auth do authentication no encryption priv do authentication and encryption by DES snmp server username xxx authentication y command is used to set the authentication manner is the user name y could be md5 or sha 29 sntp command This command is used to configure SNTP protocol of the switch Entering sntp the sub commands will be shown config sntp client Accepts time from specified time server server Specified one time server zone Set time zone dst Config daylight saving time function start time Set start time of daylight saving time end time Set end time of daylight saving time sntp client command is
10. 19 no command This command is used to disable a function or restore a setting to factory default of the switch config if no channel group Adds a port to a trunk description Interface specific description dot1x Configures 802 1x port based access control duplex Configures duplex operation flowcontrol Enables flow control during autoneg ip filter Set ipaddress filter lacp Configures LACP status map Maps priority maximum packet length Configures the maximum packet length of the port mdi mdix Configures the MDI or MDIX of the port mvr Multicast VLAN Registration port Configures the characteristics of the port port vlan Configures Port Based VLAN power saving Decrease energy consumption qos Configuration of QoS rate limit Configures rate limits shutdown Shuts down the selected interface spanning tree Specifies spanning tree configuration 49 speed Configures speed operation switchport Configures switching mode characteristics For example lacp command can enable the LACP function on the interface port s and lacp command can disable it maximum packet length 9600 will set the maximum packet size to 9600 and no maximum packet length will put it to factory default setting 1518 20 port command This command can be used to setup monitor function and security function on the interface port s config if port monitor Monitors another interface security Specifies port security port monitor etherne
11. 9 37 Current Time 1970 01 01 09 29 45 D S T status Disable D S T start 1st SUN JAN 0 00 D S T end 1st SUN JAN 0 00 D S T Is Daylight Saving Time 25 show spanning tree command This command is used to show spanning tree configuration of the switch show spanning tree command is used to show all spanning tree configuration for bridge and ports show spanning tree ethernet 1 x command is used show spanning tree configuration of Port x x is the port number For example show spanning tree ethernet 1 5 Bridge Port Number 5 Port Priority 0 255 128 Port State Linked Down Port Enable Enabled Is edge No Port Path Cost 1 65535 19 Port Designated Root 00 00 00 00 00 00 0 Port Designated Cost 0 Port Designated Bridge 00 00 00 00 00 00 0 Designated Port 5 128 Port Forward Transitions 0 Port Role Nonstp Point To Point Yes 73 26 show system command This command is used to show general system information configuration of the Switch For example show system System Configuration Main Board Information Firmware Version 1 04 14 Mac Address 00 11 22 33 44 55 Number of Ports 10 1Q VLAN Max Group 1024 DHCP Client Disable Time Server Disable System Log Status Enable Remote Log Disable Web server Enable Web server port 80 Web secure server Disable Web secure server port 443 27 show trunk command This command is used to show trunk configuration
12. Addresses Tob T Spanning Tee y VLAN sc es IGMP Trunk 8 Trunk uiro 8 Lop Contigumtion 8 1 Port Status PE Took This table is used to assign ports to Trunk groups statically Follow the steps to do it Don t connect trunk cables until this function is set Enable Trunk function first Then click Apply Select a Trunk Group at Select the member ports Click Apply Repeat b d for another Trunk group setting Note If a port are used as static port for any Trunk group its LACP function will be disable 2 Lacp Port Configuration 121 Sy Home c fnm SNMP X Security sg Pot D Adames Tahle 1 Spsumag Tove E VLAN 0 06 IM Sy Trunk information 8 Capro Congue 9 Le Port Stans sg Took Lacp Port Configuration e uwun 1221290100100 This page is used to configure LACP function With LACP protocol switches learn trunk connections automatically Follow the steps to do it Don t connect trunk cables until this function is set a Enable Trunk function at Trunk Information page first Then click Apply b Assign System Priority Its value is 1 65535 and higher number has lower priority Combining with the Mac address of the switch it is used to identify this switch in LACP protocol operation c Select ports that will run LACP protocol d Click Apply Note If ports are
13. Operation speed duplex 100Half MDI MDI X Auto show interface switchport command will show function configuration of all ports one after another show interface switchport ethernet 1 x command will show function configuration of Port x x is the port number For example show interface switchport ethernet 1 5 Information of Eth 1 5 Rate limit level of input 0 Ingress rate limit Disable Rate limit level of output 0 Egress rate limit Disable VLAN membership mode access VLAN stacking role normal Ingress rule Disable Acceptable frame type All frames Native VLAN 1 Untag vid 1 Priority for untagged traffic Low Private VLAN mode Normal IP Address of IP Filter Netmask of IP Filter 64 8 show ip command This command is used to show current IGMP configuration and switch IP configuration show ip igmp IGMP snooping interface Interface information redirects Default gateway configured for this device show ip igmp snooping command will show current switch IGMP configuration show ip igmp snooping mrouter command will show current IGMP multicast router setting For example show ip igmp snooping IGMP Status Disable IGMP Querying Disable IGMP Querying Disable IGMP Query Interval 125 seconds IGMP Report Delay 15 seconds IGMP Query Timeout 255 seconds show ip igmp snooping mrouter Type M cast Router Ports static Eth 1 show ip interface command will show current switch IP co
14. VLAN group interface For example assigning IP address to a VLAN interface is done with this command Entering interface vlan 100 and its prompt will become config interface vlan 100 config if Enter at the prompt the sub command list will be shown config if exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands interface Enters privileged interface configuration ip Internet protocol no Negates a command or sets its defaults 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this mode 3 history command 55 This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 5 quit command This command is used to quit from console interface It has the same function as logout 6 interface command This command is used to change to interface port s or another interface VLAN groups for next setup commands config if interface ethernet Ethernet port vlan Switch Virtual LAN interface For example config interface ethernet 1 5 will change the setup interface to Port 5 and all the following commands will be applied to Port 5 config if interface ethernet 1 6 7 will change the setup interface to Port 6
15. is the port number and its valid value is 1 65535 27 rate limit command This command is used to define the unit and operation mode of rate limit operation The unit could be 128Kbps to 30Mbps And the rate limit on each port is done with the level number of each port multiplied with this unit rate limit unit x command is used to set the unit for rate limit operation x is the unit number and its valid value is 128 30000 Kbps rate limit mode command is used to disable Packet Drop of Ingress Limit function When Ingress traffic rate exceeds Ingress Rate Limit the switch can drop packets or pause the traffic If packet drop is enabled flow control of ports will be disabled and packets could be dropped If packet drop is disabled flow control of ports will be enabled and pause frame will be sent when ingress traffic rate exceeds the limit no rate limit mode command can be used to enable it 28 snmp server command This command is used to configure SNMP operation of the switch Entering snmp server the sub commands will be shown config snmp server 1 5 Index of Trap community Defines SNMP community access string contact Sets the system contact string location Sets the system location string username Sets the snmpv3 user informations version Sets the snmp version snmp server community get xxx command is used to set the community string of get command for SNMP operation is the community string 40
16. you can cascade them with fiber optic cable Arother Switch Straight Through cable Max 100m 11 3 3 Application A switch can be used to overcome the hub to hub connectivity limitations as well as improve overall network performance Switches make intelligent decisions about where to send network traffic based on the destination address of the packet As a result the switch can significantly reduce unnecessary traffic The example below demonstrates the switch ability to segment the network The number of nodes on each segment is reduced thereby minimizing network contention collisions and boosting the available bandwidth per port With Management function of the switch network administrator is easy to monitor network status and configure for different applications File Server EZ 3 server TE NL sui Power Lser Workgreap 12 4 Adding Module This switch supports SFP for 1000SX LX connectors for gigabit ports Because the SFP slots support hot swap function you can plug unplug the SFP transceiver to from the SFP slot directly switch can auto detect the gigabit connection from SFP slot Follow the steps for module adding and removing Add SFP Transceiver 1 Plug in the SFP Transceiver to SFP slot directly 2 Connect network cable to the SFP Transceiver If the connected devices are working the Link Act LED will be ON Remove SFP Transceiver
17. 10 32 will allow 192 168 1 10 for network access only no ip filter command is used to clear the setting on the port s 14 lacp command This command is used to enable LACP protocol working on the interface port s lacp command will enable LACP protocol working on the interface port s no lacp command will disable LACP protocol working on the interface port s If the interface port s are already assigned to trunk by channel group command its LACP function will be ignored 15 map command For a IP packet there is priority information in ToS field of IP header The priority could be 3 bit precedence 0 7 or 6 bit DSCP 0 63 For DSCP this switch supports seven DSCP values for QoS operation and other values will be assigned to one priority This command is used to map 802 1P priority values and DSCP priority values to priority queues on the interface port s There are four priority queues for each port They are Low Normal Medium and High priority queues This command can map the priority values to the four priority queues map dscp x y z command is used to map IP DSCP values to priority queues X is the index of DSCP values and it could be 0 6 and other y is the DSCP value and its valid value is 0 63 2 is the prirority queue and its value is 0 3 0 Low 1 Normal 2 Medium 3 High map priority x y command is used to map 802 1P priority values to priority queues x is the value of 802 1P priority and i
18. 1970 OOOPBPRPBBPBOOO User admin login from web User admin login from web User admin login from console Link up port 3 Link down port 3 Link up port 3 Link down part 3 System Started User admin login from console User admin login from web User admin login from console System Started You can view log content here There could be more than one page You may change the page or go to a page by its operation icons Clicking clear log button will clear the local log table 83 6 4 2 SNMP This function is used to configure SNMP function of the switch This switch supports SNMP v1 v2c and v3 agent function and MIB Il Interface Bridge MIB 802 1Q MIB and Private MIB SNMP System Information System Information Home Object ID 1 3 6 1 4 1 60 10 C System T aaa J 0 day 2 Simin 24 E SNMP Time ay 2 hour 51 min 24 sec 8 Configuration Version LZ BC Security Name CJ Pon Contact C Addresses Table Location HE Spanning Tree Community Name iC IOMP GET Sd Trunk SET CJ DHCP Relay Agent Teci IP Address Community Name Status 0000 pobbe Diable System Information Object ID this is the SNMP Object ID of the switch for SNMP management Up Time this is the power up running time of the switch Version this is used to select SNMP agent operation version Name this the host name of the switch Contact this is the contact informati
19. 4 show dot1x command This command is used to show 802 1x configuration and status show dot1x command is used to show current 802 1x configuration and status of each port For example show dot1x Port Authentication Configuration Port Status Authentication Mode 1 1 Force Authorized 1 2 Force Authorized 1 3 Yes Force Authorized 1 4 Force Authorized 1 5 Force Authorized 1 6 Force Authorized 1 7 Force Authorized 1 8 Force Authorized 1 9 Force Authorized 1 10 Force Authorized show dot1x configuration command is used to show 802 1x configuration and status of the switch For example show dot1x configuration 802 1x Configuration 802 1x System Authentication Status Disable Re authentication Disable Re authentication Timeout Period 3600 seconds Re authentication Max Count 2 Max Request Count 2 Server Timeout Period 30 seconds Supplicant Timeout Period 30 seconds Quiet Timeout Period 60 seconds Tx Timeout Period 30 seconds 62 Supplicant Allowed In Guest Vlan Disable Dynamic vlan Disable 5 show gvrp command This command is used to show current GVRP configuration show gvrp configuration command will show current GVRP configuration show gvrp configuration GVRP configuration Disable 6 show history command This command is used to show the history of input commands show history 0 show 1 show gvrp configuration 2 show history 7 show interface command This command is used to show
20. Add Change button Different Mac Address will be another entry Mac Address is not allowed to edit for an entry 98 About Port Security function You can configure Mac Security Configuration function in Security page for port access security with Mac address Select Accept for such security application 2 Dynamic Addresses Address Table NOTE Address table will refresh once every 30 seconds HE System sme Tur wee EL EMI Security MAC Address Learning Port Status ys 00 90 08 6 19 ET Dynamic E Port EMEg Addresses Table g Static Addresses Dijana AES 8 Address Aging HE Spanning Tree amp g VLAN HQ 05 cj IGMP 00 Trek HE Tools This function can show the dynamic Mac addresses learned by the switch This table will refresh every 30 seconds The address table could be more than one page You can click Previous Page Next Page to change page Or give the page number directly Query function is supported by the switch It could be queried by Port or queried by Mac Address Select the query function and input the query target Then click Query The result will be shown For example 99 Home HQ System SNMP H Security EC Port Addresses Table Static Addresses Dynamic Addresses Address A ging EC Spanning Tree H VLAN HQ ws 03 IGMP 8 01 Tunk QQ Tools 3 Address
21. Aging Home HE System Cj SNMP QQ Security EC EM Addresses Table 9 Static Addresses s Dynamic Addresses g Eades Aang Eg Spanning Tree m VLAN Ey Qos HA IGMP EC Trak 905 Tools Quer ID MAC Address VID LeamingPot Li 00 00 2 82 8 Se ees yis NOTE Address table will refresh once every 30 seconds LEN pb oe co to j ESA 00 00 e2 82 8c e6 Address Table Address 00 11 d8 ce 46 fc 00 ee 00 00 00 01 00 16 d3 eb 7f 21 00 0 0 00 03 28 00 90 08 0 64 7 00 0 6 64 1 9 00 90 f5 28 84 93 00 c0 f6 01 09 91 00 90 08 a7 76 c6 00 c0 f6 01 11 40 VID Learning Port Status Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Dynamic Port Aging Time Setting Port Aging Time Setting ARL Aging ARL Aging Time seconds 9 Enable O Disable 300 The switch will learn Mac addresses to an ARL table automatically And follow the table to do packet forwarding operation for some time the Mac addresses will be removed from the table This operation is called aging The aging operation could be disable here And all the learned Mac addresses will not be removed from the ARL table If Mac addresses are not received The time interval for aging operation could be modified here default 10
22. For example interface ethernet 1 2 4 7 and the settings after this command will be applied to Port 2 Port 4 and Port 7 3 interface ethernet 1 x y and X y are port number All the settings after this command will be applied to ports in this range For example interface ethernet 1 4 7 and the settings after this command will be applied to Port 4 Port 5 Port 6 and Port 7 Port 4 7 44 Dar Dag Dor 4 interface ethernet 1 w x y z and w x y z are port number All the settings after this command will be applied to those ports For example interface ethernet 1 1 2 4 7 and the settings after this command will be applied to Port 1 Port 2 Port 4 Port 5 Port 6 and Port 7 Port 4 7 Entering interface ethernet 1 5 and its prompt will become config interface ethernet 1 5 config if Enter at the prompt the sub command list will be shown config if exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands channel group Adds a port to a trunk description Interface specific description dot1x Configures 802 1x port based access control duplex Configures duplex operation end Exit from interface mode flowcontrol Enables flow control during autoneg interface Enters privileged interface configuration ip filter Set ipaddress filter lacp Configures LACP status map Maps priority maximum
23. Limit No Limit g Pon 6 No Limit No Lamit C Addres Table 7 No Limit No Limit HO 2 Tue 8 No Limit No Limit eC 9 No Limit No Limit bey s 10 No Limit No Lamit IGMP sil Follow the steps to configure a Set Unit first It could be selected from pre defined units or define by user 95 Click Apply after the setting b Select the Port Number c Enter the rate limit level for Ingress and Egress traffics 0 means NO LIMIT Click Apply after the setting About Packet Drop for Ingress Limit function When Ingress traffic rate exceeds Ingress Rate Limit the switch can drop packets or pause the traffic If packet drop is enabled flow control of ports will be disabled and packets could be dropped If packet drop is disabled flow control of ports will be enabled and pause frame will be sent when ingress traffic rate exceeds the limit 5 2 Storm Control Configuration This function can setup the broadcast multicast and unicast storm rate of the Switch Storm Control a 0 NO LIMIT E Home 1 7 1K 2K 4K 8K 64K 1 2 ik m a m 808 Security 0 NOLIMIT Apply EHE Port 8 Port Configuration 9 Port Information 9 Max Packet Length S Minox Port Configurat Ny Rete Limit S Rete Control Conti s Siu Control Cont 8 Port Statistics HQ Addresses Table QQ Spanning Tree lt gt v Please follo
24. Port Learning by RSTP H Forwarding Port link up and forwarding frames o Forwarding Port link up and forwarding by RSTP Number is Partner port number if other switch has LACP enabled Refresh LACP Port Status Port Protocol Active Partner Port Number Operational Port Key no no no no no no no no 0 0 HUF no 10 no 123 6 4 11 DHCP Relay Agent Option 82 DHCP Relay Agent Option82 DHCP Relay Agent OplionB2 Configuration DHCP Relay Agent 82 Status Disable v 23 Nome information dg Sytem Relay Agent information Maximum length 32 gt 2 Pod CJ Address Table DHCP Server IP Address 401 Spemmug Tose VLAN C Os IMP 7 Cg DHCP Relay Agent Option 8 Configuston E Took DHCP Relay function will control DHCP requests and forward DHCP requests to the assigned DHCP server DHCP Relay Agent Option 82 function will add connection port VLAN ID and switch information to DHCP requests and then send to the specified DHCP server Based on those information DHCP server will assign an IP configuration in the DHCP reply This is a security function This page is used to configure DHCP Relay Option 82 function DHCP Relay Option 82 function will add the following information to DHCP request packet 1 Port number that DHCP request packet comes from 2 VLAN ID for this DHCP reque
25. already in static trunk group they are not allowed to apply as LACP ports If static ports are selected as LACP ports warning message will be prompted when Apply is clicked 3 Lacp Port Status SC SNMP GQ Secuity 901 Port EC Addresses Table EC Spanning Tree VLAN HG 005 a IGMP EHE Trunk 8 Trunk information 8 Lecp Port Configuration Lace Port Status LACP Aggregation Overview 331 23456789 10 Legend E Down Port link down 0 Blocked Port Blocked by RSTP Number is Partner port number if other switch has LACP enabled 0 Learning Learning by RSTP a Forwarding Port link up and forwarding frames o Forwarding Port link up and forwarding by RSTP Number is Partner port number if other switch has LACP enabled Refresh 1 ACP Part Statue This is for LACP protocol running status 122 You can see current port status with colors If LACP trunk is created another port groups message will be shown Click Refresh can update the status information The following table will show the LACP enable disable status of each port Port number and port key of the partner switch will also be shown in the table when LACP Trunk is running Home EC System HA SNMP Security HC Port HEC Addresses Table EC Spanning Tree E VLAN BE Qs IGMP EMEg Tonk Trunk information Lacp Port Configuration Cap Pon Stig EM Tools Bee T 0 Learning
26. command user can select the operation mode of port when auto is set to disabled 29 For Auto Negotiation mode the switch will disable port auto negotiation function when the auto function of port in Port Configuration setting is disabled For Auto Detect mode the switch will always keep port auto negotiation function ON but just modify its attribution if auto function of port in Port Configuration setting is disabled For applications you should select Auto Detect mode if the connected device is auto negotiation enabled For example customer s PC is auto negotiation enable and you want to set his network connection to work at 10Mbps And you can select Auto Negotiation mode if the connected device is auto negotiation disabled it is called forced mode sometimes Some old TX FX Converters needs to work in this mode because FX supports 100 Full forced mode only For most applications Auto Detect mode is OK With automode the sub commands will be shown config automode detect Auto Detect mode negotiation Auto Negotiation mode automode detect command will set it to auto detect mode automode negotiation command will set it to auto negotiation mode 8 default command This command is used to restore factory default settings Before start it a confirm message wil be prompted 9 dhcp relay command This command is used to configure DHCP Relay Option 82 function Note The DHCP Relay function here d
27. config interface vlan 10 xxxx config if guest mode If guest guest is used for username password the console interface will enter guest mode Its prompt is ended with gt With command you can find the command list as follow 21 exit Exit from current mode help Show available commands history Show list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands show Show the counters that the system uses In guest mode it is allowed to view the switch configuration only No setup configure commands are supported lt lt Function Keys gt gt Here is the function keys for console interface Tab key this key can help to get the full command keyword with just several beginning letters For example cal Tab will get the full calendar command word Esc key this key can use to break message display and go back to command prompt Up Arrow key this key can get last input command Down Arrow key this key can get next input command Left Arrow Right Arrow key the key can move the cursor Backspace key this key can delete the letter in front of cursor key this key can get the command list Command Mode There are four command modes for console interface 1 General Basic Commands These are basic commands after login Users can show switch configuration status ping network device reb
28. configuration backup update 18 6 2 Settings with Console Connection 6 2 1 Basic of the Console Interface lt lt Enter Console Interface gt gt Please follow the steps to complete the console hardware connection first 1 Connect from console port of the switch to COM port of PC with the console cable 2 Start the terminal program of Windows Create a new connection and select COM port of PC used for the console Set the configuration of the terminal as 9600 8 N 1 You can find the terminal program in Start gt Programs gt Accessory Programs gt Communication gt Terminal If you cannot find it please install it from your Windows Installation Disk Please refer to your Windows user manual for the installation 3 Power on the switch If everything is correct the booting screen will appear in the terminal program when the switch is powered on It will stop at the following screen after some initializing messages Booting Program Version 1 04 04 SI PI built at 12 04 53 Sep 17 2008 RAM 0x00000000 0x00800000 0x0000cc78 0x007f3000 available FLASH 0x05800000 0x05a00000 32 blocks of 0x00010000 bytes each gt enter C to abort booting within 3 seconds Start to run system initialization task System Configuration Company Name Model Name Switch MAC Address 00 12 34 64 99 6F Firmware version 1 05 14 Username lt lt User Modes gt gt There are two user modes for the s
29. delete the 802 1Q VLAN 107 1 5 VLAN Table Active 802 1Q VLAN Table Total page 1 eM Coto page i CMC ss v 5 1 Static Default 5 5 5 5 s 5 5 1 Table 21 Spanning Tree cg VLAN 8021Q YLAN 4 00210 YLAN 19 VLAN Tag Rules 8 Sut 1Q VLAN 4 FLARE Tb IC Prime VLAN 9 Port Bored VLAN Qui SE GMP zl This table will show the activity of 802 1Q VLAN Both static and dynamic 802 1Q VLAN will be shown in the table For ports S means static member and D means dynamic member If GVRP protocol is enabled this table will also show the learned remote 802 1Q VLAN 2 Private VLAN Three kinds of VLAN are defined for this application Primary VLAN Community VLAN and Isolated VLAN Community VLAN and Isolated VLAN can communicate with Primary VLAN but they cannot communicate with each other And users in Isolated VLAN cannot communicate with each other This is a special 802 1Q VLAN configuration 108 2 1 Configuration Private VLAN Setting NOTE 802 10 must be enable in 802 10 VLAN for Private VLAN working VLAN Name Type Pew s 2 4094 Maximum length 16 caj HEC Addas Table Cy VLAN VLAN Select fs Type iG 902 10 VLAN VLAN ID VLAN Type VLAN Name Gy Privo VLAN EIN 8 Coufgushod g Post Configumtien Delete 9 VLAN Oy tomer QQ Truk Took a Creating Private VLAN do the st
30. function of the switch And no trunk comand can be used to disable it The trunk function for the switch works with LACP protocol The system priority of LACP is set by lacp command the settings on ports is done in interface command 33 username command This command is used to set the username and password for administrator and guest username admin www XXX yyy zzz command is used to set the username and password for administrator www is the old username is the old password is the new username zzz is the new password username guest yyy zzz command is used to set the username and password for guest yyy is the new username zzz is the new password Administrator is the user who has the right to do configuration modification Guest is the user who has the right to view configuration only 34 vlan command This command is used to enter VLAN configuring mode And the prompt will become config vlan database config vlan The operations for VLAN are configured in VLAN configuring mode Please refer to 6 2 5 VLAN Configuring Commands section for the details 43 6 2 4 Interface Configuring Commands Commands in Configuring Mode are for general switch settings And its prompt is config y The port interface function and VLAN group interface function are set with interface command config interface ethernet Ethernet port vlan Switch Virtual LAN interface i
31. input the agent information DHCP Server IP Address is used to specify the DHCP server for DHCP Relay operation 125 6 4 12 Tools The follow functions are used for system maintenance They are Software Upgrade Configuration Backup Restore Restore Factory Default Reset System and Ping functions 1 Tools Information Four functions are supported as the system maintenance tools Maintenance Tools System Upgrade Enter the path and name of the upgrade file then click the START button START Sy Home H Sytem Ta mne Config Backup Restore C Security Please press the Backup Setting button to save the configuration data Lo your PE Port Backup Setting Backup Setting Vo ext file Address Enter the path and name of backup file then press Restore Setting button SE Spemmug Tose Restove Setting VLAN fo Qs IGMP Restore Factory Default Please press the Restore button to restore the factory default settings of the Device 01 Tok Restat S Took g Took information 9 Ping Reset System In the event that the Device t stops respo onding correctly or in some way stops functionang you can perform a reset Please press the Reset button Reset System Upgrade This function will upgrade the system operation software from the web management PC Config Backup Restore Backup Setting Clicking this button the switch will backup the configuration of the switch to the web
32. of the switch show trunk configuration Show Trunk Configuration all Shows all Trunking Group Configuration group Shows Each Trunking Group Configuration show trunk configuration command is used to show trunk function enable disable setting show trunk all command is used to show port member settings of all trunk groups show trunk group x command is used to show port member settings of Trunk Group x x is the trunk group index 28 show version command This command is used to show system version information and model information For example show version Firmware Version 1 05 00 Number of Ports 10 Model Name 10G Switch SNMP Management 29 show vlan command This command is used to show VLAN configuration of the switch 74 show vlan private vlan Private VLAN id VLAN interface name VLAN interface name port based Port Based Virtual LAN Configuration cr show vlan command is used to show all 802 1Q VLAN settings enable disable VLAN ID VLAN Name VLAN Type and Assigned ports show vlan id x command is used to show VLAN setting of VLAN x x is the VLAN ID show vian name yyy command is used to show VLAN setting of VLAN yyy is the VLAN name For example show vlan id 100 Vlan ID 100 VLAN Type Static Name P100 Ports Port channel Eth1 1 s Eth1 2 s Eth1 3 s Eth1 4 s show vlan name P100 Vlan ID 100 VLAN Type Static Name P100 Port
33. port information and status show interface counters Interface counters information status Interface status information switchport Interface switchport information show interface counters command will show total statistics counters for all ports show interface counters ethernet 1 x command will show statistics counters for Port x x is the port number For example show interface counters ethernet 1 3 Port 1 3 Rx Counter Statistics Good Unicast Frame 4109 Good Broadcast Frame 9946 Good Multicast Frame 158 Discarded Frame 0 Errors 0 Total Receive Byte Count 1549816 Tx Counter Statistics Good Unicast Frame 2001 Good Broadcast Frame 18 Good Multicast Frame 0 Discarded Frame 0 Errors 0 Total Transmit Byte Count 873047 63 show interface status command will show port status of all ports one after another show interface status ethernet 1 x command will show port status of Port x x is the port number For example show interface status ethernet 1 5 Basic information Port type 1000TX Mac address 00 11 22 64 99 6F Configuration Name Port 5 Port admin Enable Speed duplex Auto on Capabilities 10half 10full 100half 100full 1000full Broadcast storm Disable Flooded unicast storm Disable Multicast storm Disable Flow control Disable Power saving Disable LACP Disable Max MAC count 0 Maximum Packet Length 9600 IPaddress Filter 1 Current status Link status Up
34. to their connection devices and your applications If a port is defined as Hybrid it is a tag port basically But it will act as an untag port for packets working in VLAN defined in Untag VID So it is called a hybrid port For example set Port 5 as Hybrid and its Untag VID as 10 Port 5 will act as a tag port for all packets except packets for VLAN 10 Port 5 will act as an untag port for packets working for VLAN 10 105 1 3 VLAN Stacking VLAN Stacking wo T 2 www 2 wax HE Addams Table 6 wmm 05 Spanning Tme Cy VLAN osi s wax 1 Eg VLAN x 9 8 8 VLAN Tog Rule 10 wea 1 8 VLAN d Ti 10 YLAN 8 VLAN Tabie Private VLAN d Por Bosed VLAN Tun z VLAN Stacking function allows two VLAN tags in a packet for 802 1Q VLAN tunnelling application through a central network For VLAN Stacking operation port role definition is needed for each port There are three roles for a port Normal Tunnel and Access Normal It will set the port s as normal 802 1Q VLAN port s And the tagged untagged setting will follow the settings in 802 1Q VLAN Access It will set the port s as access port s for VLAN stacking operation It will strip a tag from tagged or double tagged packets before forwarding It is for downward connection of VLAN sta
35. two operation modes for this MVR function is Dynamic mode Another is Compatible mode In Dynamic mode the switch will send IGMP reports to every MVR source port in the MVR VLAN In Compatible mode the switch will not send IGMP reports xX is the MVR VLAN ID mvr x name yyy command is used to assign a name to the MVR VLAN is the MVR VLAN ID is the name string After MVR VLAN is created source port of IP multicast traffic and receiver ports of subscribers will be assigned next Assigning source port and receiver port to MVR VLAN is done config if mode go with interface ethernet 1 x command x is the port number Please refer to command in Section 6 2 4 1 for the details 22 no command This command is used to disable a function or restore a setting to factory default of the switch config no aaa AAA Service automode Set Auto Negotiation or Auto Detect mode dhcp relay Set Auto Negotiation or Auto Detect mode dot1x Configures 802 1x port based access control hostname Sets system s network name ip Global IP configuration sub commands ip filter Enable IP address filtering function lacp Configures LACP status logging Modifies message logging facilities mac address table Configuration of the address table management Specifies management IP filter mirror Configuration of mirror mvr Multicast VLAN Registration qos Configuration of QoS queue Assigns priori
36. used define the log level of events The valid value of x is 0 7 logging on command is used to enable the logging function And no logging on command is used to disable the logging function logging remote log command is used to configure remote logging function Entering logging remote log the sub commands will be shown config logging remote log 1 5 Index 35 cr logging remote log command is used to enable the remote logging function Events will also be sent to syslog servers no logging remote log command is used to disable it logging remote log x host y y y y command is used to set IP address y y y y to syslog server with index x Up to five x 1 5 syslog servers are supported 18 mac address table command This command is used to configure functions for Mac address table of the switch Entering mac address table the sub commands will be shown config mac address table aging time Aging time for entries in the address table static Sets MAC address table static information mac address table aging time x command is used to set to aging time of the switch The valid value of x aging time in seconds is 10 1000000 and O If x 0 the aging operation will be disable mac address table static x x x x x x interface ethernet 1 y command is used to assign a static Mac address x x x x x x to Port y of the switch The static mac address will not be aging out by the switch 19 management command This com
37. users in the VLAN with VLAN ID 5 to manage the switch remotely It works only 802 1Q VLAN function is enable About DHCP Client renew and release button renew button If DHCP client function is enabled you can click renew button to refresh the lease time of the IP address If IP configuration is not got when boot up clicking renew button will try to get IP configuration again release button If DHCP client function is enabled and IP configuration is got clicking release button will release current IP configuration After that you can click renew button to get the IP configuration again 3 Time Configuration Time Setting Get Time by Server Manually Daylight Saving Time Enable Ci Home CUN System 9 System Information End Time wi SUN Start Time wat 000 of JAN wat 00 19 iP Configuration Time Server 720 1 90 1 58 58 8 Time Contiguration Time Zone Tapani v CJ Log SNMP DE Security eC Pot CI Addresses Table Spanning Tree SC VLAN 005 iC IGMP Trunk Current Time 1990 0 ta 45 lt gt There two ways to get the system time 8 Get time from Time Server This switch support NTP protocol to get time from Internet time server For such application you have to select Get Time by Time Server input the IP of Time Server and select the Time Zone of your location Then click Ap
38. v2c v3 agent function and MIB Il Interface Bridge MIB 802 1Q MIB and Private MIB The default GET community name is public and SET community name is private This switch supports up to five trap receivers with different trap community names 77 6 4 Management with Http Connection Users can manage the switch with Http Web Browser connection The default IP setting is 192 168 1 1 and NetMask 255 255 255 0 The default IP Gateway is 192 168 1 254 Before http connection IP address configuration of the switch could be changed first 1 2 3 4 Please follow the instruction Section 6 2 to complete the console connection Login in with admin password is also admin by default Use show ip interface command to check IP address of the switch first If IP address needs to be changed follow the steps 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 Enter config command and the prompt will become config Enter interface vlan 1 command and the prompt will become config if Enter ip address yyy yyy yyy yyy command XXX XXx Xxx xxx is the IP address and yyy yyy yyy yyy is the netmask to modify IP address of the switch Enter exit command to go back to config prompt If IP Gateway will be set enter ip default gateway command to set the IP gateway of the switch is the IP address
39. 0 It is 300 seconds by 101 6 4 6 Spanning Tree Spanning Tree Protocol can prevent traffic looping in network It can be configured for switch unit bridge and port unit If spanning tree function is enabled any link down to link up will have several seconds delay for the port going to forwarding state Setting of Bridge Rapid Spanning Tree Bridge Spanning Tree C Enable Disable Force Version 6 Normal Compatible with old STP 0 61440 in steps of Bridge Priority 32768 001 Hello Time 2 1 10 Maximum Age 20 6 40 m Addi Table Pe Forward Delay 15 4 30 EE Spanning Tree B Configuration Input Format 2 hello time 1 lt maximum age lt 2 forward delay 1 VLAN HG Ws Configuration STA Port 903 IGMP Trunk BMC Tool Here are the parameters for Spanning Tree operation on the switch Enable Disable enable disable spanning tree operation Force Version It will operate as Rapid Spanning Tree in Normal state And it can be forced to operate at old Spanning Tree mode if Compatible with old STP is selected Bridge Priority 0 61440 Bridge priority is for selecting the root device root port and designated port The device with the highest priority lowest value becomes the STA root device If all devices have the same priority the device with the lowest MAC address will then become the root device Hello Time 1 10 the period to send the spanning tre
40. 1x function is enabled the switch will act as an authenticator for users accessing network through the switch It needs a RADIUS server for the authentication function Users will be asked for username and password before network access If the RADIUS server authenticates it the switch will enable the port for network access This function is very useful for network security application to prevent illegal users access network through the switch 88 802 1x Configuration 802 1x System Authentication Status Des Re authenticabon Disable v Re authentication Timeout Penod 3600 0 65535 seconds 5 Cg Re authentication Max Count 2 0 10 d Veer Account Max Request Count 2 0 10 18 MAC Secunty Config Server Timeout Period po 0 65535 seconds Mmi Supplicant Timeout Period po 0 65535 seconds 8 Coutipention Quiet Timeout Period p 0 65535 seconds e Tx Timeout Period 9 0 65535 seconds TG Port Guest VLAN sales Dynamic VLAN Dussble C VLAN cesi Teak Radius Server IP Address pei SE DHCP Rehy Radius Server Port Number 10227 Security Key x The function here is for 802 1x function configuration 1 802 1x Authentication Status Enable Disable Transparent Enable enable 802 1x function in authentication mode Disable disable 802 1x function Transparent only forwarding 802 1x packets Re authentication enable disable Timeout Period and Max Co
41. 375391 SNMP BMC Security Port BE Addresses Table Current Static Address Setting 8 sae ENNTINENNICTRENEN NEN T7 DCN 8 Dynamic Addresses 8 Address Aging GC Spanning Tree BE VLAN BC 005 IGMP Trunk Eg Tools This switch supports static Mac address assignment You can assign static Mac addresses by the following steps a Give an Entry ID This ID is used as the index of the entry in Static Address Table b Give the VLAN ID If 802 1Q is disable the VID will always be 1 This VID will put the static Mac address in some VLAN for 802 1Q VLAN operation c Fill the Mac address This is the Static Mac Address for this entry d Select the port for this Static Address e Click Confirm Add Change button Then this entry will be added to the table In Current Static Address Setting table you can edit and delete an entry Different Mac Address will be another entry Mac Address is not allowed to edit for an entry The switch will not age out these static Mac addresses But there is a limitation for these static Mac addresses they are allowed to work on the assigned port only because they are static fixed on the assigned port If you want to delete an entry in the static Mac address table click Delete button of the entry and the static Mac address will be removed from the table If you want to modify an entry click Edit button of the entry Do the modification and click Confirm
42. 4 v li 802 1 Priority Tag 3 Normal z TM Ane 802 1 Priority Tag 2 5 js E 802 1P Priority Tag 1 low 7 le 802 1P Priority Tag 0 lw 8 Qui information Quewe Mode Iu 8 Quewe Ba IMP Tru T Tek For 802 1P priority priority value 0 7 in VLAN tag will be used for QoS operation And the mapping of priority values to priority queues High Middle Normal Low could be defined here This mapping is done by port And All could be selected for every port If 802 1P priority function is enabled these settings will be followed for QoS operation 114 DiffServ Priority Mapping IP Differentiated Services DiffServ Configuration a NER 73 Cy Home 3 CQ Xn Pel EC SNMP C eC Pot FC Addmens Tabie 4 4 E 4 C Spanning Tree VLAN FED All Others 18 002 information S Queue Mode 8 Queue Scheduling 0 SQ Tuak By Took 244 3 H DSCP priority operation will use the priority setting in ToS field of IP packets for QoS operation Seven DSCP values 0 63 could be defined and map to priority queues High Middle Normal Low This mapping is done by port And All could be selected for every port If DSCP priority function is enabled these settings will be followed for QoS operation 2 Queue Mode Queue Mode Cy Home Ams OG System Cg SNMP Se
43. 4886 2 2659 1021
44. 7 and all the following commands will be applied to Port 6 7 If vlan sub command is used the setup interface will be changed to some VLAN groups For example config if interface vlan 100 will change the setup interface to VLAN 100 and all following commands will be applied to VLAN 100 The description of commands in interface configuring mode is put in Section 6 2 4 Interface Configuring Commands Please refer to the section for the details 7 ip command This command is used to set IP address of the switch on this VLAN interface And only users in this VLAN can access this switch with the IP address remotely config if ip address dhcp Dynamic host configuration protocol A B C D IP address renew Renew IP release Release IP ip address dhcp command is used to enable DHCP client function DHCP client function will try to get IP configuration from DHCP server in network And no ip address dhcp command can be used to disable it 56 ip address x x x x y y y y command is used to set IP address of the switch on this VLAN x x x x is the IP address is the subnet mask For example address 192 168 1 12 255 255 255 0 will set the IP address of the switch on this VLAN group for remote management ip address renew command is used to refresh the lease time of the IP address got by DHCP If IP configuration is not got when boot up this command will try to get IP configuration again i
45. 812 Securty Key 1234567 his 8 Ume Accounts S MAC Port Status Authentication Mode Cy 21x 1 Yes Fes Amthorcest e 4 2 gt gt FoeeAwhourd Addvesaes Table 2 lo eee 6 8 HC Tewdk 9 DHCP Relay 10 FovtAshoumi 22 Tool of Apply E Radius Server Configuration This function is for the configuration between switch and RADIUS server You can assign the IP address of Radius Server the protocol port number and the security key Port Authentication Configuration The Port Authentication Configuration is used to select the authentication mode for each port of the switch 1 Auto This is the normal 802 1x operation mode The authentication status authenticated or unauthenticated depends on the authentication result of port 2 Force Authorized This mode will force the port always being authentication successful in 802 1x process and the real authentication result will be ignored 3 Force Unauthorized This mode will force the port always being authentication fail in 802 1x process and the real authentication result will be ignored 4 None This mode will disable 802 1x operation on this port And you can see current 802 1x status on each port 4 IP Filter Configuration This function is used to configure IP Filtering function of port An IP address with a subn
46. Compatible mode the Switch will not send IGMP reports Source Port this is the uplink port of this MVR VLAN to the IGMP traffic source It could be tagged port or untagged port Receiver Port this is the ports connecting to subscribers receiving IP multicast traffic in the MVR VLAN After the MVR VLAN is configured you can assign IP multicast groups video channels to the MVR VLAN in MVR Group page You can assign more than one IP multicast groups video channels to one MVR VLAN Note 1 After MVR VLAN are created those VLAN will be added to 802 1Q VLAN Checking VLAN Table of 802 1Q VLAN those VLAN will be seen 2 Source Port of MVR VLAN could be tagged or untagged port Please set it at VLAN Tag Rules of 802 1Q VLAN It should be tagged port in most cases If it is an untagged port remember to set its Port VLAN ID according to your application 4 MVR Group 119 MVR Group Configuration Multicast VLAN ID 100 v Name Maximum length 8 DIC NN 2 System lt 2 NM BE Security 902 Current Groups Entries Table 02 Table WD Spanning Tme T AN lg vii startaddress End address c Qt 1 100 5 1 225 0 0 1 225 0 0 10 Delete ey M 100 Sport 2 225 0 2 1 225 0 2 10 8 GM confipertion g TP Begistmi 3 MVR VLAN 8 MVR GROUP 03 Trak 22 DHCP Relay T Tools After
47. Entering spanning tree the sub commands will be shown config spanning tree compatible Compatible with old STP forward time Global STA forward time configuration Range 4 30 seconds hello time Global STA hello time configuration Range 1 10 seconds max age Global STA maximum age configuration Range 6 40 seconds priority Specifies spanning tree priority cr spanning tree command is used to enable spanning tree protocol function And no spanning tree command is used to disable it spanning tree compatible command is used to change its operation to 802 1D STP instead of 802 1w RSTP And no spanning tree complatible command is used to set it back spanning tree forward time x command is used to set the forwarding delay of spanning tree operation It is the maximum waiting time before changing states This delay is required because every device must receive information about topology changes before it starts to forward frames x is the delay time and its valid value is 4 30 in seconds spanning tree hello time x command is used to set the period to send spanning tree maintenance packet if the switch is the root of spanning tree x is the period time and its valid value is 1 10 in seconds spanning tree max age x command is used to set the spanning tree aging time if no spanning tree maintenance packet is received x is the time and its valid value is 6 40 in seconds spanning tree priority x command
48. Host and Promiscuous Normal is for ports doing normal 802 1Q operation instead of Private VLAN Host is for ports that could be in Community VLAN or Isolated VLAN Promiscuous is for ports that could be in Primary VLAN or Isolated VLAN Follow the steps to do the port assignment a Select the type for a port b If it is Host you can select a VLAN from Community VLAN or mark Isolated VLAN and select from it Community VLAN must be associated first c If it is Promiscuous you can select a VLAN from Primary VLAN or mark Isolated VLAN and select from it d Repeat a c to complete the port assigment e Click Apply Please see the following picture 110 Private VLAN Port Configuration Porte Port Type Primary VLAN Community VLAN Isolated VLAN 1 Pemba 2 E v9 21 r 2 2 Hast v9 p s ra 4 E reag Pot 5 Hast E rene E F s rhea PO Addres Toble 6 52 s mI Speumug Tee 7 zi 22 tease 9 2 r 55 EHE VLAN ps vs g ex S Configenson 10 Normal r 52 9 Port Contigurstion 8 Port Band VLAN C os ig C Tm CJ Took a 3 Port based VLAN Port Based Virtual LAN VLAN Name VLAN li oy Home Sg Sim SNMP WC Security SE Port Adams Table DE 002 10 VLAN iC Pues VLAN 8 Por Ba
49. MENT INTERFACES 77 6 3 1 About Telnet Management 77 6 3 2 About SNMP Management 77 6 4 MANAGEMENT WITH HTTP 78 System ai UU pre PRU DAC Die 80 PETRI 84 6 4 3 Security 3 cinere E PED DOOR ats 86 6 4 4 PO eie M beet Dr pte dud 92 6 4 5 Address Table tid poa pite oe nen corn ave eeu 98 6 4 6 Spanninig iat tr e a EB UR REEL 102 OX AU EE 104 64 8 009 113 117 ER NUNT EE 121 6 4 11 DHCP Relay Agent Option 82 seen 124 64 12 TO0lS ai enti pee epe ree p UH Pee 126 7 SOFTWARE UPDATE AND BACKUP eese nnne 128 A PRODUCT 129 B COMPLIANCES a sensa snas tns itas taa 133 C WARRANTY 5 iiis iix Ra Ead CRAT CA ARCEM RU LE FRUTAS 134 1 Introduction There are two models for the Gigabit Management Switch Series 8TX 2SFP 10G model and 24TX 4SFP 24G model This Gigabit Management Switch is a Layer2 Management switch with lots of advanced netw
50. N group Create a multicast group for MVR VLAN mode Set MVR VLAN operation mode name Set MVR VLAN name cr Create a MVR VLAN mvr x command is used to create MVR VLAN with VLAN ID x mvr command is used to delete a MVR VLAN mvr x 8021p priority y command is used to set the 802 1P priority 0 7 for MVR operation The IGMP control packets for this VLAN will be assigned this priority when tag is added x is the MVR VLAN ID y is the 802 1P priority value mvr x active command is used to set the MVR VLAN to active state x is the MVR VLAN ID mvr x active command is used to set the MVR VLAN to 37 inactive state mvr x group yyy start address m m m m end address n n n n command is used to create a IP multicast group for the MVR VLAN After MVR VLAN is created you can assign IP multicast groups video channels to the MVR VLAN And you can assign more than one IP multicast groups video channels to one MVR VLAN is the MVR VLAN ID is the name of the IP multicast group is the start IP multicast address n n n n is the end multicast address For example 10 group abc start address 224 0 0 1 end address 224 0 0 2 no mvr x group command is used to delete the IP multicast group named from MVR VLAN x mvr x mode compatible mvr x mode dynamic command is used to set the operation mode of the MVR VLAN There are
51. Port based priority are enabled on the interface port s at the same time its decision flow is DSCP 802 1P gt Port base 24 rate limit command This command is used to set the ingress and egress rate limit level of the interface port s The working rate limit number is counted with rate limit level x rate limit unit The rate limit unit is set by rate limit unit x command in general configuring mode under config prompt And the rate limit level is set by this command rate limit input level x command is used to specify the ingress rate limit level of the interface port s is the level number and its valid value is 0 31 If X 20 it means no limit rate limit output level x command is used to specify the egress rate limit level of the interface port s is the level number and its valid value is 0 31 If 51 X 20 it means no limit 25 shutdown command This command is used to disable the interface port s shutdown command is used to disable the interface port s no shutdown command is used to enable it 26 spanning tree command This command is used to configure spanning tree function on interface port s config if spanning tree cost Specifies spanning tree cost edge port Specifies spanning tree edge port port priority Specifies spanning tree port priority spanning disabled Disables the spanning tree spanning tree cost x command is used to set spanning tree port path cost valu
52. Relay f Current Setting amp Link Status It is current status of ports Name The name of the port Admin It shows current port enable disable status Auto It shows current Auto enable disable status of ports S u peed Duplex It shows current working speed and duplex mode if ports are link p Orthe setting of speed duplex when auto is disable 93 Flow Control It shows current Flow Control function status of ports Power Saving It shows current Power Saving enable disable status of ports MDI MDI X It shows current MDI MDI X setting of ports Link It shows the link status of each port 3 Max Packet Length 29 Home A System SNMP EM Security Port j Port Configuration Port Information Max Packet Length Mirror Port Configurat Rate Limit Port Statistics Cj Addresses Table D amp 6 1 Spanning Tree m VLAN Eg 905 lt gt a Maximum Packet Length 7 1518 1518 1518 iw 1518 1518 i 1518 1518 v 1518 v This switch supports Jumbo Frame function And the maximum packet size could be up to 9600 byte packet can select the maximum packet size for each port here 4 Mirror Port Configuration This switch operates in store and forward algorithm so it is not possible to monitor network traffic from another connection port But the port mirror function can copy packe
53. Unplug the SFP Transceiver from SFP slot directly 13 5 LEDs Conditions Definition The LEDs provide useful information about the switch and the status of all individual ports For 8TX 2SFP 24TX 4SFP Models LED STATUS CONDITION Power ON Switch is receiving power System OFF System is booting Yellow System is initializing Green System is running Link Act Port has established a valid link Flashing Data packets being received or sent Green The connection speed is 1000Mbps Yellow The connection speed is 10 100Mbps FDX Col ON The connection is Full Duplex Flashing Collisions happen for Half Duplex 14 6 Manage Configure the Switch 6 1 Introduction of the management functions This switch is a L2 Management switch It supports in band management function from Http Telnet SNMP interfaces Console is supported for local command line settings supports network configuration functions like VLAN Trunking Port Mirror QoS spanning tree and software backup update Users can configure these functions for different network applications The following is a brief introduction about these functions before the detail operation sections VLAN Virtual LAN VLAN can divide the switch to several broadcast domains to prevent network traffic between different user groups This switch supports 802 1Q tag based VLAN and Port based VLAN Users with the same VLAN ID ca
54. YR VLAN Yes MVLAN 1 100 0 Dynamx 10 1 2 3 Dele 8 MYR GROUF 2 Yes MVLAN 2 200 0 Dynamic 6 78 9 Deke C Trek SC DHCP Tok Note Port being tagged untagged SA 802 1Q VLAN setting 21 If Source Port Is untagged port assign its PVII This page is used to configure MVR Multicast VLAN Registration function VLAN function will isolate traffic between VLAN groups But it will also isolate IP multicast traffic for subscribers in different VLANs The MVR function allows one multicast VLAN to be shared by subscribers in different VLANs That can reduce the multicast traffic for VLANs Before configure MVR complete the following two functions configuration first 118 1 Complete 802 1Q VLAN setting first 2 Enable IGMP snooping function first This switch supports three MVR VLANs and MVR VLAN can be created in this page Here is the description about those settings Active this MVR VLAN is enabled disabled Name you can assign a name for the MVR VLAN for identification Multicast VLAN ID this is the VLAN ID for this MVR VLAN It is 1 4094 802 1P Priority this is 802 1P priority 0 7 The IGMP control packets for this VLAN will be assigned this priority when tag is added Mode there are two operation modes for MVR function One is Dynamic mode Another is Compatible mode In Dynamic mode the switch will send IGMP reports to every MVR source port in the MVR VLAN In
55. a setting to factory default of the switch config vlan no 1q vlan Configures 802 1Q VLAN port vlan Configures Port Based VLAN private vlan Private VLAN vlan Switch Virtual LAN interface For example 1q vlan command can enable 802 10 VLAN function and no 1q vlan command can disable it no vlan 100 command will remove VLAN 100 9 port vlan command This command is used to enable Port base VLAN And 802 1Q VLAN function 59 will be disable at the same time port vlan command is used to enable Port base VLAN no port vlan command is used to disable it 10 private vlan command This command is used to create VLAN groups for Private VLAN and create the associations between Primary VLAN and Community VLAN config vlan private vlan 100 association Association name VLAN interface name private vlan x association y command is used to create the association between Primary VLAN x and Community VLAN y private vlan x association add y command is used to add the association between Primary VLAN x and Community VLAN y private vlan x association remove y command is used to remove the association between Primary VLAN x and Community VLAN y no private vlan x association command is used to reomove all the association for Primary VLAN x config vlan private vlan 100 name sales community Community isolated Isolated primary Primary private vVlan x yyy community command is used to crea
56. abit connection And they can auto detect the connection from 1000TX RJ45 port or SFP port Contents INTRODUCTION Euer 7 1 1 PACKAGE CONTENTS s cccscssscssecsccsncnscsesssnecsuccncessessecuseusessasssconscssessecsteonacenses 7 WHERE TO PLACE THE SWITCH 8 CONFIGURE NETWORK 11 3 1 CONNECTING DEVICES TO THE 11 3 2 CONNECTING TO ANOTHER ETHERNET SWITCH HUB _ 11 IJS APPLICATION bap re P ead HERE eg 12 ADDING MOD ULE 13 LEDS CONDITIONS DEFINITION 4214 4 44 442 4 4 1 2 14 MANAGE CONFIGURE THE SWITCH eeeeeeee nennen nena 15 6 1 INTRODUCTION OF THE MANAGEMENT FUNCTIONS eee 15 6 2 SETTINGS WITH CONSOLE 19 6 2 1 Basic of the Console Interface 19 6 2 2 General Basic Commandqs 24 6 2 3 Configure Mode Commands sss 28 6 2 4 Interface Configuring Commands sss 44 6 2 5 VLAN Configuring Commands sss 58 6 2 6 Show Commands eese nennen nnne nnn nan 61 6 3 ABOUT TELNET AND SNMP MANAGE
57. allowed IP addresses can access network through the switch ports ip filter command is used to enable this function no ip filter command is used to disable this function And assigning the filtering IP Subnet to ports is done by ip filter command config if mode go with interface ethernet 1 x command is the port number Please refer to ip filter command in Section 6 2 4 1 for the details 16 lacp command This command is used to configure LACP function of the switch Entering lacp 2 the sub commands will be shown config lacp system priority Combined with MAC address to form LAG identifier lacp system priority x command is used to configure the system priority for operation of the switch Its value is 1 65535 and higher numbers have lower priority Combining with the Mac address of the switch it is used to identify this switch in LACP protocol operation Adding ports to LACP trunk group is by command in Interface Configuring Commands for Port Please refer to Section 6 2 4 1 for the details 17 logging command This command is used to configure logging function of the switch The logging function can record events at local flash or remote log server Entering logging the sub commands will be shown config logging log level Log level on Enable logging to all supported destination remote log Enable logging to remote host logging log level x command is
58. and This command is used to show current system information and system configuration Enter show at the prompt the sub command list will be shown show aaa Show AAA service configuration calendar Date and time information dhcp relay DHCP Relay Configuration dot1x 802 1x content gvrp GVRP configuration history History information interface Interface information ip IP information ip filter IP Filter Configuration lacp LACP statistics line TTY line information log Log records mac address table Configuration of the address table mac security MAC Security Configuration management Management IP filter map Maps priority mvr Show MVR Status port Port characteristics queue Priority queue information radius server RADIUS server information running config Information on the running configuration rate limit Configures rate limits 25 snmp Simple Network Management Protocol statistis sntp Simple Network Time Protocol configuration spanning tree Spanning tree configuration System System information trunk Trunk information version System hardware and software versions vlan Virtual LAN settings With sub commands different configuration settings will be displayed More help information for them will be prompted with show xxxx xxxx is the sub command For example entering show ip will get the prompt message show ip igmp IGMP snooping interface Interface information redirects Default gateway con
59. ay timer for each group membership on the network interface of the incoming Query When the timer expires a report is generated for the corresponding host group IGMP Query Timeout this is used to set the timeout interval for IGMP Query operation If the switch does not receive updated membership information in a timely fashion it will stop forwarding multicasts to the delinquent port where the end device is located Router Port This is used to select the port that connected to IGMP active router 117 2 IP Multicast Registration Table IP Multicast Registration Table Members Group Total 0 Total page t urrent page page mks Previous Page NextPase 5 m em Group VID Group Address Members Port C SNMP 42 Seunty E Port m Addis Tobe 402 Tove SE VLAN c o I0MP IGMP confipenson IP Multicast Registrato MVR VLAN a MYROROUP HAC Trunk DHCP Rehy i Cj Took This table will show the learned IP multicast groups 3 MVR VLAN MVR VLAN Configuration r Maximum length 15 Sy Home PO See ee Dynamic C compatble PE Port Number 1 2 7 10 SE Port Source Port 5 5 HAC Addres Table Recesver Port e s T Spanning Tme Non member 6 6 3 6 3 amp 3 6 SE VLAN ta Any Os Cy IGMP 8 IOMP Current Multicast VLANs Entries Table a M
60. c Broadcast Multicast and Unicast Storm Control Yes by IP Subnet Protocol interface limit Yes by NTP protocol Yes Local and Remote by syslog logging Console 129 In band Management http s telnet and SNMP SNMP v1 v2c v3 agent support MIB II Bridge MIB 802 1Q MIB and Private MIB Software Update Backup by http TFTP protocols Xmodem for firmware and configuration binary text 130 Access Method Standards Conformance Communication Rate MDI MDIX Indicator Panel Number of Ports Dimensions Certification Temperature Humidity Bridging Function Switching Method Address Table Filtering Forwarding Rate Maximum Packet Size Flow Control VLAN VLAN Stacking QoS Spanning Tree Trunking Mirror Port IGMP Snooping MVR Mac ID Security on Port IP Filter on Port 802 1x DHCP Relay Rate Control Storm Control Admin Manage Security System Time System Log Out band Management In band Management 24TX 4SFP Model Ethernet CSMA CD IEEE 802 3 10BASE T IEEE 802 3u 100BASE IEEE 802 3z IEEE 802 3ab 1000Base 10 100 1000Mbps Full Half duplex auto negotiation Auto detect forced mode is supported LEDs for each unit Power System each port Link Act Green 1000M Yellow 10 100M FDX Col 24 RJ45 TX 4 SFP shared ports 24 GE Ports totally 440 x 172 x 43 mm CE Mark FCC Class A Standard Operating 0 to 50 1096 to 9096 Non condensing Filtering forwarding and learning Store a
61. ch are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures are required to correct the interference CE Mark Declaration of Conformance for EMI and Safety EEC This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 class A EN60555 2 1995 class A EN60555 3 1000 4 2 1995 4kV CD 8kV AD 1000 4 3 1995 3V m IEC 1000 4 4 1995 1kV power line 0 5kV signal line This product complies with the requirements of the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC Warning Do not plug a phone jack connector into the RJ 45 port This may damage this device 133 C Warranty We warrant to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of one year from the date of purchase from us or the authorized reseller The warranty does not cover the product if it is damaged in the process of being installed We recommend that you have the company from whom you purchased this product install it 134 135 TC union m E info ctcu com SC tcu F 4886 2 2659 0237 WWW T
62. cking operation Tunnel It will set the port as tunnel port for VLAN stacking operation It will add a tag and allow two 802 1Q VLAN tags in a packet It is for tunnel and upward connection of VLAN stacking operation SPVID is used as the Port VLAN ID of VLAN Stacking L2 Tunnel operation if the port role is access 106 1 4 Static 10 VLAN 802 1Q Static VLAN Setting VLAN 10 VLAN Name Maximum length 16 Modify Static VLAN Table VLAN Select ly 402 Addas Table SE Spanning Tme VLAN 10 VLAN Type VLAN Name 1 STATIC CHEN ARQ VLAN Port Number 1 2 3 4 5 6 8 9 10 G2 10 VLAN member G 6 6 G n 6 8 VLAN Tay Rules Non member e 8 Enc YQ YAR D a VLAN Table Avs pn IC Puvele VLAN 8 VLAN O s IGMP zl This function is used to maintain 802 1Q static VLAN Create an 802 1Q VLAN 1 Input the VLAN ID and VLAN Name in Create New Static VLAN Click Create to create the VLAN The valid VLAN ID is 1 4094 2 Select the VLAN in Modify Static VLAN Table The new VLAN is empty by default You can select ports for the VLAN After that click Apply to complete the VLAN configuration Modify an 802 1Q VLAN 1 Select the VLAN in Modify Static VLAN Table 2 Modify its setting and click Apply to activate the new setting Delete an 802 1Q VLAN 1 Selectthe VLAN in Modify Static VLAN Table 2 Click Delete to
63. cuity Pot 9 No Seomty Y SE Addams Table 10 N A No Secutty 3 Spenning Tove Amy SE VLAN 20g Qs IGMP 2 Trek DHCP Relay Took 2 _ There are two Mac ID security modes for the switch One is Static Mac ID Filter on Port another is Dynamic Mac ID Number Limit on Port Static Mac ID Filter on Port This function can limit only those static Mac addresses on the port can access 87 network Other Mac addresses will be rejected by the port Sometimes it is called Mac Port Binding Follow the steps to configure it a Set the Security Control to Accept on those ports that will apply static Mac ID security Then click Apply b Set Static Mac Addresses that are allowed for network access at Static Address of Address Table function Please refer to that section for the details Dynamic Mac ID Number Limit on Port This function can limit the Mac ID number to access network through a port For example five Mac ID are allowed for Port 2 That means up to five users are allowed but don t care who the users are Follow the steps to configure it a Set the Security Control to Limited by MAC no on those ports that will apply dynamic Mac ID number security And set the Max MAC no to the users number allowed on the ports b Then click Apply The switch will learn users automatically and show current user number at Learned no 3 802 1x Configuration If 802
64. curity Gy Port IC Addes Table PC Spanning Tre 423 VLAN Qui 8 WS information Quewe Mode 8 Quese Scheduling CQ QQ Trek Oy Took This switch supports Strict Priority and WRR Weight Round Robin operation for sending out packets from piority queues 115 If Strict Priority is selected packets in higher priority queues will always get bandwidth service first Lower priority queues will get service when higher priority queues are empty If WRR is selected priority queues will be served with the weighting of priorities And the setting of weight could be configured at Queue Scheduling 3 Queue Scheduling Queue Scheduling WAR Setting Table Priority Weight nm Traffic Class 0 vehi UM e Traffic Class 1 weieht2 ja me Trafic Class 2 vs UB Sexy Traffic Clase 3 gt fot DE Tob C Spsumag VLAN 95 8 Qui 3 Quee Mode 8 IGMP C Tmu 12 Took This function is used to configured the weighting of priority queues for WRR operation And the output bandwidth will be shared with the ratio of weighting between priority queues 116 6 4 9 IGMP This switch supports IGMP Snooping function for IP Multicast traffic Switch will learn IP Multicast Groups from IGMP protocol packets Here is for IGMP function configuration settings IGMP IGMP Configuration IGMP Status C Enab
65. d packets and is used for switch to users connection And its role is a access connection for users Port VLAN ID Setting switchport native vlan x command is used to assign VLAN ID of the native VLAN for classifying untagged frames on ingress port x is the port VLAN ID PVID and its valid value is 1 4094 When untagged packet is received PVID of the ingress port will be used as its working VLAN ID is also used as the VLAN ID for tag adding when untagged packet is translated to tagged packet Untag VLAN ID Setting for Hybrid Ports switchport untag vid x command is used to set untag VID of the port It is used when this port is set to hybrid role for 802 1Q function And packets for this untag VLAN will be forwarded with untagged Other packets will be forwarded with tagged x is the VLAN ID and its valid value is 1 4094 Private VLAN Port Assignment switchport private vlan host association x command is used to assign this interface port s to a Community VLAN the port type of the interface port s must be host first is the VLAN ID of the Community VLAN and its valid value is 2 4094 switchport private vlan isolated x command is used to assign this interface port s to a Isolated VLAN And the port type of the interface port s must be host or promiscuous first is the VLAN ID of the Isolated VLAN and its valid value is 2 4094 switchport private vlan map
66. d by the switch from packets of IGMP active router with IGMP snooping function It is often used for video applications 12 MVR Multicast VLAN Registration VLAN function will isolate traffic between VLAN groups But it will also isolate IP multicast traffic for subscribers in different VLANs The MVR function allows one multicast VLAN to be shared by subscribers in different VLANs That can reduce the multicast traffic for VLANs 13 DHCP Relay amp DHCP Option 82 DHCP Relay function will control DHCP requests and forward DHCP requests to the assigned DHCP server DHCP Option 82 function will add port and switch information to DHCP requests and then send to the assigned DHCP server Based on those information DHCP server will assign an IP configuration in the DHCP reply This is a security function 14 IP Filtering This function can limit the IP address and the subnet for accessing network from switch port That can prevent illegal IP problem in network 15 Software Backup Update This switch supports backup and update functions for its internal software and its network configuration It could be done in two ways 17 a From console when booting doing by Xmodem protocol and by terminal program for boot code and run time code updating b From web browser doing by http protocol and by web browser for run time code and configuration backup update c From telnet or console command doing by tftp protocol for run time code and
67. e Bridge Port Number is the Ethernet port that will be configured Port Priority 0 240 If the path cost for all ports on a switch are the same the port with the highest priority lowest value will be forwarded when looping happens If more than one port have the same highest priority the port with lowest port number will be forwarded Port State It is current spanning tree operation state of the port Port Enable enable disable spanning tree function on the port Is edge If this switch is at edge of the network tree please select Yes If there are another switches connected please select No This parameter is used by RSTP to increase its operation speed Port Path Cost 1 65535 It is used to determine the best path between devices if looping happens Lower values will be forwarded and should be assigned to ports with high speed connections Higher values will be blocked and should be assigned to ports with low speed connections The suggestion values are 100 50 600 for 10M 19 10 60 for 100M and 4 3 10 for 1000M connections Port Designated Root This shows the root bridge ID of this segment and its bridge priority Port Designated Cost This shows the path cost between the root port and the designated port of the root bridge Port Designated Bridge This shows the switch s bridge ID and its bridge priority setting Designated Port This shows the port number and its port priority Port Forward Transitio
68. e maintenance packet if the switch is the root of the spanning tree Default is 2 seconds Maximum Age 6 40 the spanning tree aging time if no spanning tree maintenance packet is received t will cause the spanning tree to re create Default is 20 seconds Forward Delay 4 30 the maximum waiting time before changing states i e learning to forwarding This delay is required because every device must receive information about topology changes before it starts to forward frames In addition each port needs time to listen for conflicting information that would make it return to a blocking state otherwise temporary data loops might result The parameters have relation with each other And here is the rule for it 2 Hello Time 1 is less or equal to Maximum Age and Maximum Age is less or equal to 2 Forward Delay 1 102 Setting of Port Click Configuration STA Port You can configure RSTP STP on ports Spanning Tree Bridge Port 3 Port Priority 0 240 in steps of 16 js sd BMC System Port State Linked Down Port Enable Enable C Disable HE Port Is edge C Yes No EC Addresses Table Port Path Cost 1 65535 19 EHE Spanning Tree Port Designated Root 00 00 00 00 00 00 0 9 Configuration Port Designated Cost 0 id Port Designated Bridge 00 00 00 00 00 00 0 1 HE IGMP Designated Port 1 128 EC Tmk Port Forward Transitions 0 EC Tools Port Role Nonstp Point To Point Yes Apply Configure STA Bridg
69. e on the interface port s It is used to determine the best path between devices if looping happens Lower values will be forwarded and should be assigned to ports with fast connections Higher values will be blocked and should be assigned to ports with slow connections is the cost value and its valid value is 1 65535 The suggestion values are 100 50 600 for 10M 19 10 60 for 100M and 4 3 10 for 1000M connections spanning tree edge port command is used to set the interface port s as edge port And no spanning tree edge port command is used to set it as non edge port Edge means the interface port s are connected to end device s but not switch to switch connection spanning tree port priority x command is used to set the spanning tree port priority value on the interface port s x is the port priority value and its valid value is 0 240 If the path cost for all ports on a switch are the same the port with the highest priority lowest value will be forwarded when looping happens If more than one port have the same highest priority the port with lowest port number will be forwarded spanning tree spanning disabled command is used to disable spanning tree function on the interface port s And no spanning tree spanning disabled command will enable it 27 speed command This command is used to set the operation speed of the interface port s config if speed auto Set port speed to be auto 10 Set port spe
70. e port type of the interface port s in Private VLAN as host host port s could be for Community VLAN or Isolated VLAN switchport mode private vlan promiscuous command will set the port type of the interface port s in Private VLAN as promiscuous promiscuous port s could be for Primary VLAN or Isolated VLAN no switchport mode private vlan command will set the port type of the interface port s in Private VLAN as normal normal port s is for normal 802 1Q VLAN operation VLAN Port Tag Untag Setting for 802 1Q VLAN switchport mode hybrid command will set the interface port s as hybrid port s for 802 1Q VLAN operation If a port is defined as hybrid it is a tag port basically But it will act as an untag port for packets working in VLAN defined in Untag VID So itis called a hybrid port For example set Port 5 as hybrid and its Untag VID as 10 Port 5 will act as a 53 tag port for all packets except packets for VLAN 10 Port 5 will act as an untag port for packets working for VLAN 10 switchport mode trunk command will set the interface port s as tag port s for 802 1Q VLAN operation Tag port will always send tagged packets and is used for switch to switch cascading It is a VLAN trunk connection because there could be more than one VLAN working through it switchport mode access command will set the interface port s as untag port s for 802 1Q VLAN operation Untag port will always send untagge
71. e re authenticated server period Time after an authenticator sends a RADIUS Access Request packet to the authentication server supplicant period Time after an authenticator sends an EAP Request MD5 Challenge frame to a supplicant tx period Time switch waits before re transmitting EAP packet dotix timeout quiet period x command is used to set the quiet time value between the switch and the user before next authentication process when authentication fail The valid value of x is 0 65535 dotix timeout re authperiod x command is used to set the timeout period for doing re authentication process The valid value of x is 0 65535 dot1x timeout server period x command is used to set the request timeout value between the switch and RADIUS server The valid value of is 0 65535 dotix timeout supplicant period x command is used to set the timeout value between the switch and users called supplicant in 802 1x after first identification The valid value of x is 0 65535 dotix timeout tx period x command is used to set the timeout value for the identification request from the switch to users The request will be re tried until the authcount is met After that authentication fail message will be sent The valid value of x is 0 65535 32 Note 1 Setting 802 1x function on ports use dot1x command in interface configuring mode 2 Setting for RADIUS server use radius server command Please refer to sections
72. e view command users in this groups have view right only management x protocol http snmp telnet command is used to enable the remote management protocol for some user groups is the index of the user group More than one protocols can be enabled at the same time e g management 2 protocol http snmp telnet And no management x protocol command is used to disable all remote management protocols for the user group 20 mirror command This command is used to enable mirror function of the switch And no mirror command can be used to disable mirror function of the switch 21 mvr command This command is used to configure MVR Multicast VLAN Registration function VLAN function will isolate traffic between VLAN groups But it will also isolate IP multicast traffic for subscribers in different VLANs The MVR function allows one multicast VLAN to be shared by subscribers in different VLANs That can reduce the multicast traffic for VLANs Before configuring MVR function complete the VLAN setting first Using MVR function you have to enable IGMP snooping function first This switch supports three MVR VLANs They are referred with their VLAN ID For any MVR setting you have to assign the VLAN ID in the command Entering mvr x the sub commands will be shown is a VLAN ID with number in 2 4094 For example mvr 10 config mvr 10 8021p priority Configure 802 1p priority tagging active Active a MVR VLA
73. ed to be 10M 100 Set port speed to be 100M 1000 Set port speed to be 1G 52 speed auto command will set the interface port s to auto negotiation mode speed 10 command will set the interface port s to 10M speed speed 100 command will set the interface port s to 100M speed speed 1000 command will set the interface port s to 1000M gigabit speed 28 switchport command This command is used to configure some switch function characteristics for the interface port s config if switchport acceptable frame types Specifies frame type allowed Configures the VLAN port list mode Configures the port mode native Configures the PVID of the port private vlan Private VLAN untag vid Configures the port untag vid vlan stacking VLAN Stacking port mode Accept Frame Type switchport acceptable frame types all command is used to allow the interface port s to accept all types of frame switchport acceptable frame types tagged command is used to allow the interface port s to accept tagged frame only Other frame type will be rejected VLAN Port Assignment switchport allowed vlan add x command will add the interface port s to VLAN x is the VLAN ID and its valid value is 2 4094 switchport allowed vlan remove x command will remove the interface port s from VLAN x is the VLAN ID and its valid value is 2 4094 VLAN Port Mode Setting for Private VLAN switchport mode private vlan host command will set th
74. end event record to the syslog server About log function configuration System Log Status This can enable disable system logging function Log Level 0 7 Log levels 0 7 are defined as below And events with lower log level than this number will be recorded Level Name Description 0 Emergency System is unusable 1 Alert Action must be taken immediately 2 Critical Critical conditions 3 Error Error conditions 4 Warning Warning conditions 5 Notice Normal but significant condition 6 Informational Informational messages 7 Debug Debug level messages 82 Remote Log This can enable disable remote syslog function Remote Log Server IP This is the syslog server IP for remote logging Up to five syslog servers is supported Event logs will be sent to those syslog servers at the same time Log Table amp Home System 8 System Information 8 IP Configuration 8 Time Configuration 29 Log 18 Configuration 9 Cog Table EC SNMP GQ HA Port EC Addresses Table EC Spanning Tree EC VLAN Eg Qos IGMP EC Trunk Logs Table So to pave 2 Thu Jan 01 09 11 29 1970 Thu Jan 01 09 07 20 1970 Thu Jan 01 09 05 58 1970 Thu Jan 01 09 04 40 1970 Thu Jan 01 09 04 17 1970 Thu Jan 01 09 04 12 1970 Thu Jan 01 09 04 07 1970 Thu Jan 01 09 00 02 1970 Thu Jan 01 10 09 26 1970 Thu Jan 01 09 02 05 1970 Thu Jan 01 09 00 34 1970 Thu Jan 01 09 00 02
75. ention to the following factors 1 Temperature Because the temperature in a rack assembly could be higher than the ambient room temperature check that the rack environment temperature is within the specified operating temperature range Please refer to Product Specifications in the manual Air flow is necessary a rack for temperature stable 2 Mechanical Loading Do not place any equipment on top of this rack mounted Switch 3 Circuit Overloading Be sure that the supply circuit to the rack assembly is not overload after installing this switch 8 4 Grounding Rack mounted equipment should be properly and well grounded Particular attention should be given to supply connections other than direct connections to the mains Attach Rack Mount Brackets to the Switch e 39 le g 1 Position a Rack Mount Bracket on one side of the Switch 2 Line up the screw holes on the bracket with the screw holes on the side of the switch 3 Use a screwdriver to install the M3 flat head screws through the mounting bracket holes into the switch There could have two or four screws for one bracket That depends on the model that installed 4 Repeat Step 1 3 to install another bracket to the switch 5 Now it is ready to mount to a rack Mount the Switch on a Rack I 7 iS o 5 ee 1 Position a bracket that is already attached to the switch on one s
76. eps first a Create VLAN groups and define as Primary Community or Isolated b Associate Community VLAN with Primary VLAN If more than one Primary VLAN select Primary VLAN first and then do the association See the following picture Private VLAN Setting NOTE 802 1Q must be enable in 802 1Q VLAN for Private VLAN working Create New Private VLAN REA ID VLAN Name Type Pay 24094 Maximum length 16 SE SNMP Create EHI Security Port den Spanning Tree Ey VLAN VLAN Select 2 Pies Cj 80210 VLAN VLAN ID VLAN Type VLAN Name EHE Private VLAN 2 STATIC 1 S Configuration S Port Configuration 8 Por Bssed VLAN sa as Community VLAN 3 E IGMP EC Trunk 4 amp SA Tool Apply 109 2 2 Port Configuration After VLANs are created assign ports to VLANs Private VLAN Port Configuration Porte Port Type Primary VLAN Community VLAN Isolated VLAN 1 Now 3 vl none 21 r 21 2 2 DE 3 gt A sl HJ cial SE Pot 5 Mes x JEF 00 Addresses Table 6 Namal E E r zz Tar Susie in 7 Nu 5 n 2 a J m z EHE Pale VLAN E VLLL ose gl z r zl 8 Configenson 10 Noal E E m m x D Axes 3 Port Bound VLAN PE tome Tr 89 2 Tools a There are three types for a port Normal
77. et mask can be defined for each port If this function is enabled only devices with IP address in the subnet can access network through the port 90 IP Filter ENDE 00 A Sy Home bE irm vor number inn network maito B 90 SNMP ly 1921681010 cg Secunty Ej eter Port Number Start Address End Address Addr Number 9 NAC Prenton Cation 192 169 8 1 192 168 11 254 102 BE 192 168 1 1 192 168 1 15 15 aS TP F r 192 168 1 176 192 168 1 183 8 D ig Port FQ Adamss Table C Spanning Tove Oy VLAN 2 as sg OMP 05 Tmk mj DUCE Rely 2 Took 4 2 5 T Because it is a subnet specified by IP address Network ID Number 0 32 or called Subnet Mask the start IP address end IP address and allowed IP address number are shown in the table If some specified IP address will be assigned set the Subnet Mask as 32 For example 192 168 1 82 32 91 6 4 4 Port This section is about configurations for ports For port speed setting maximum packet size setting mirror port setting port bandwidth limit and port statistics 1 Port Configuration Port Configuration Auto Detect C Auto Negotiation Apply 2 LINNCTHNICTHEN ONITITSNUUNNCRNECIIN s pest v 0 xz omne SE Port 8 PortCanfigenson 3 Port 08 Max Packet Length g Mirr Post Cosfigumti 821 Re g Port Statistics
78. ettings DHCP server will assign the IP configuration according to this Option 82 content Entering dhcp relay the sub commands will be shown config dhcp relay helper address Specify DHCP servers IP addresses information Specify a additional information for DHCP Option 82 option Enable to add the additional information to Option 82 cr Enable DHCP relay dhcp relay command is used to enable DHCP Relay function dhcp relay command is used to disable it dhcp relay helper address xxx xxx xxx xxx command is used to assign the DHCP server for DHCP Relay operation XXX XXX XXX XXX is the IP address of DHCP server dhcp relay information xxx command is used to specify the additional information string for DHCP Option 82 operation is the string dhcp relay option command is used to enable adding the additional string to Option 82 dhcp relay option command is used to disable it 10 dotix command This command is used configure the general settings of 802 1x function of the switch Entering dot1x the sub commands will be shown config dot1x authcount Set 802 1x Re authentication Max Count dynamic vlan VLANS are assigned based on a MAC address guest vlan Migrating end users to an 802 1X environment and for delivering limited services to unauthorized users max req Max EAP request identity packet retransmissions re authentication Forces re authentication on all ports interfaces Sys
79. ffic will loop in the network If network loop happens spanning tree protocol will block one connection in the loop automatically But it will also cause a period of delay 30 seconds for STP and shorter time for RSTP if any network connection is changed because of the network topology detection operation of the protocol Because there could be more than one switch in the network users can 15 configure this function for their network spanning tree application 4 Port Mirror This switch operates in store and forward algorithm so it is not possible to monitor network traffic from another connection port But the port mirror function can copy packets from some monitored port to another port for network monitor 5 QoS For Quality of Service request in a network packets could be classified to different forwarding priorities For real time network traffic like video audio it needs higher priority than normal network traffic With the definition of packet priority it could have 8 priority levels from 0 to 7 This switch supports four priority level queues on each port could be configured for port based 802 1P tagged based or DiffServ of IP packets priority User can define the mapping of priority values to the priority queues 6 Static Mac ID in ARL table The switch can learn the Mac address from user s packets and keep these Mac address in the ARL table for store and forward table lookup operation But these Mac addresses wil
80. figured for this device And entering show ip igmp will get next help message show ip igmp snooping IGMP snooping configuration And entering show ip igmp snooping will get the IGMP settings show ip igmp snooping IGMP Status Disable IGMP Querying Disable IGMP Querying Disable IGMP Query Interval 125 seconds IGMP Report Delay 15 seconds IGMP Query Timeout 255 seconds If the display is more than one console page Esc can be used to break the display For the details please refer to section 6 2 6 Show commands 9 calendar command This command is used to set the system time It is entered in lt hour minute second month day year gt order For example calendar set 10 30 0 october 15 2008 show calendar Current Time 2008 10 15 10 30 18 It is 18 seconds passby after the setting command 10 configure command This command will change the console interface to configure mode And the prompt will become config In this mode administrator can do system configuration of the switch 26 The operation of configure mode will be described in next section exit command can be used to quit this operation mode 11 copy command This command is used to backup system configuration firmware to TFTP server restore system configuration from TFTP server and update firmware from TFTP server copy binary config Copies binary configuration file config Copies configuration file firmware C
81. for the commands 11 end command This command is used to exit from configure mode 12 hostname command This command is used to set the name of the switch in network This name is also used as the hostname for SNMP agent function of the switch 13 interface command This command is used to entering interface configuring mode There are two sub commands for it one is ethernet it is for port setting another is it is for VLAN groups characteristics setting config interface ethernet Ethernet port vlan Switch Virtual LAN interface All the port setting commands are put in interface configuring mode like rate limit setting speed duplex setting And characteristics settings for VLAN groups are also done in interface configuring mode like IP address assignment For example the console will enter interface configuring mode for Port 5 with interface ethernet 1 5 command And the prompt will become config interface ethernet 1 5 config if With interface ethernet 1 5 6 10 13 the console will enter interface configuring mode for Port 5 6 10 11 12 13 And all the settings will be applied to those ports at the same time The description of commands in interface configuring mode is put in Section 6 2 4 Interface Configuring Commands Please refer to the section for the details 14 ip command This command is used to configure some IP depending functions Entering ip 2 the sub comma
82. he priority setting in ToS field of IP packets for QoS operation Seven DSCP values 0 63 could be defined and map to priority queue at IP Differential Service DiffServ Configuration page by clicking Configure DSCP Priority button Configure VLAN Tag Priority button Click this button can go to the VLAN Tag Priority page for 802 1P priority values 0 7 to priority queue mapping setting 113 Configure DSCP Priority button Click this button can go to the IP Differential Service DiffServ Configuration page for priority values 0 63 to priority queue mapping setting C Enable amp Disable Apply Port Number 1 2 3 4 5 6 7 8 9 10 Low c c c c c c I Home Normal Bg Sym Medium Be SNMP High C Secwity XE Port EC Addresses Table Bg VLAN Port Number 1 2 3 4 5 6 7 8 9 10 29 QoS On e o s o 1 QoS information off c c c c c c c c c c S Queue Mode Apply 8 Queue Scheduling oe gg Trunk Port Number 1 2 3 4 5 6 7 8 9 10 90 Tools On o s off c c c c c c c ELA 802 1P Priority Mapping VLAN Tag Priority VLAN Tag Priority Classes Port Tag Priority Class 23 Home 802 1P Priority Tag 7 High hE Sytem Port 802 1 Priority Tag 6 m d SNMP 802 1P Priority Tag 5 Meim v Secunty 802 1P Priority Tag
83. ide of the rack 2 Line up the screw holes on the bracket with the screw holes on the side of the rack 3 Use a screwdriver to install the rack screws through the mounting bracket holes into the rack 4 Repeat Step 1 3 to attach another bracket that is already attached to the switch on another side of the rack 10 3 Configure Network Connection 3 1 Connecting Devices to the Switch Connection Guidelines For 10BaseT connection Category 3 or 5 twisted pair Ethernet cable For 100BaseTX connection Category 5 twisted pair Ethernet cable For 1000BaseTX connection Category 5e or 6 twisted pair Ethernet cable For TX cable connection always limit the cable distance to 100 meters 328 ft as defined by IEEE specification If your switch has 1000BaseSX 1000BaseLX connections you can connect long distance fiber optic cable to the switch Because this switch supports Auto MDI MDI X detection on each TX port you can use normal straight through cable for both workstation connection and hub switch cascading Cat5e Twkt d P alr Cable 100 mete j 3 2 Connecting to Another Ethernet Switch Hub This Switch can be connected to existing 10Mbps 100Mbps 1000Mbps hubs switches Because all TX ports on the Switch support Auto MDI MDI X function you can connect from any TX port of the Switch to the MDI or MDI X port of another hub switch with Straight Through or Crossover cables If the switches have fiber optic ports
84. ing running config please wait calendar set 9 30 14 january 1 1970 interface VLAN 1 IP address 192 168 1 1 255 255 255 0 71 SNTP server 220 130 158 54 interface ethernet 1 10 port vlan 1 Default VLAN lend 22 show rate limit command This command is used to show rate limit settings For example show rate limit Ingress Drop Mode Enable Rate Control Unit Kbps 128 Rate Control Configuration Port Ingress Egress 1 1 No Limit No Limit 1 2 No Limit No Limit 1 3 No Limit No Limit 1 4 No Limit No Limit 1 5 No Limit No Limit 1 6 No Limit No Limit 1 7 No Limit No Limit 1 8 No Limit No Limit 1 9 No Limit No Limit 1 10 No Limit No Limit 23 show snmp command This command is used to show SNMP configuration of the switch For example show snmp SNMP Configuration Object ID 1 3 6 1 4 1 x 60 10 System up Time 597 seconds System Name Location Contact name Get Community public Set Community private Trap Community ID Status Community IP Address 1 Disabled public 0 0 0 0 2 Disabled public 0 0 0 0 3 Disabled public 0 0 0 0 72 4 Disabled public 0 0 0 0 5 Disabled public 0 0 0 0 Version V3V2cV1 Username admin SnmpSecurityLevel noauth Authentication MD5 Privacy Des 24 show sntp command This command is used to show system time settings of the switch For example show sntp Get Time By Manually Time Server 220 130 158 54 Time Zone Japan
85. ion Security Login keal 18 User Accounts Amy 19 Secunty Config PC 802 1 Security Policy C IP Filter TE no http is selected Web management will become disable Pon I modify is selected setting configuration will become disable 8 CJ Adresses Table or enabled Address Net Mask Mode Telnet 2 C3 Spanning Tree 1 0000 f 0000 v 2 VAN 2 0000 1255252524 we Cg 009 3 a 0000 255 255 255 255 View o o a IGMP 1 D 0000 1 255 255 255 255 View m oO o oO DEJ Trunk This is used to setup the IP addresses that can manage this switch They have different access rights set in Mode And the remote management interfaces Http Telnet SNMP could be enable disable for different administrators This function is for security policy of switch management Note Remember to enable at least one IP Subnet with Modify right for Http Telnet SNMP interface Otherwise configuring switch from remote will become impossible In that case you can manage the switch from console only 2 Mac Security Configuration MAC Security Configuration Port amp Max MAC no Learned no Security Control 1 N A No Santy z 2 N A No Secudrr gt 3 N A No Secanty 4 N A No 5 N A No Seowity User Accomm 6 P N A s MAC Secunty Cou c i 7 N A No Secudry gt mc 9021 c 80 IP Fr 8 N A No Se
86. ion of the interface port s 12 interface command This command is used to change the interface port s or interface VLAN groups for next setup commands config if interface ethernet Ethernet port vlan Switch Virtual LAN interface For example config interface ethernet 1 5 will set current setup interface to Port 5 and all the commands will be applied to Port 5 config if interface ethernet 1 6 7 will change current setup interface to Port 6 7 and all the commands will be applied to Port 6 7 If vlan sub command is used current setup interface will be changed to some VLAN groups For example config if interface vlan 100 will change current setup interface to VLAN 100 and all next commands will be applied to VLAN 100 The description of commands in interface configuring mode is put in Section 6 2 4 Interface Configuring Commands Please refer to the section for the details 13 ip filter command 47 This command is used to set the IP address and subnet for IP Filtering operation on the port s If the IP address is set and IP Filtering function is enabled only network devices in this IP subnet can access network through the port s ip filter xxx xxx xxx xxx y command is used to set the IP address and subnet for IP Filtering operation on the port s is the IP address y 0 32 is the network ID bit number or called subnet mask For example ip filter 192 168 1
87. is used to set the bridge priority of the switch Bridge priority is for selecting the root device root port and designated port The device with the highest priority lowest value becomes the STA root device If all devices have the same priority the device with the lowest MAC address will then become the root device is the priority and its valid value is 0 61440 The settings of spanning tree on port are done in interface command The settings here are for bridge only 31 storm control command 42 This command is used to set the storm control rate The packet storms that could be controlled are broadcast multicast and unicast flooding traffic And the rate is counted with packet per second pps not bit per second bps storm control bc rate x command is used to set rate limit for broadcast traffic x is the limit rate number and its valid value is 0 7 O disable 1 1Kpps 2 2Kpps 3 4Kpps 4 8Kpps 5 16Kpps 6 32Kpps 7 64Kpps storm control mc rate x command is used to set rate limit for multicast traffic X is the limit rate number and its valid value is 0 7 O disable 1 1Kpps 2 2Kpps 3 4Kpps 4 8Kpps 5 16Kpps 6 32Kpps 7 64Kpps storm control fc rate x command is used to set rate limit for unicast flooding traffic x is the limit rate number and its valid value is 0 7 O disable 1 1Kpps 2 2Kpps 3 4Kpps 4 8Kpps 5 16Kpps 6 32Kpps 7 64Kpps 32 trunk command This command is used to enable trunk
88. isable is selected this port will be disabled for any network access 4 Select the Enable Disable state of Auto function of port The auto mode could be auto negotiation or auto detect operation when auto is set to disable 5 f Auto is disabled select the operation speed and duplex mode of the port in Speed Duplex 6 Select the Enable Disable state of Flow Control function of port 7 Select the Enable Disable state of Power Saving function of port If it is enabled port will go to low power state when link down 8 Select MDI MDI X operation mode It could be Auto MDI or MDI X Auto can auto detect and get the correct connection mode MDI will set the port to MDI mode for switch to switch connection MDI X will set the port to MDI X mode for user PC connection 9 Click Apply after any modification 2 Port Information E ETE ent S i Pvc T m 2 Pon2 is ou Hal nem em AL AUTO Hone i Enable Enable ou Hat Disable Disable Down DC System 5 Pons Enable Enable 100M Half Disable Disable AUTO E ES Ss Sy for 4 49 Enable Enable 0M Half Disable Disable N A 10 10 Enable Enable OM Half Disable Disable N A ug S Rat Limit 18 Port Configuston 8 Port Information d Max Packet Length 8 Port Configas 9 PoctStatistics Table Spanning Tree VLAN Qos IGMP Trunk DHCP
89. ity 802 1P priority and DSCP priority These priority operations could be enable disable on each port For 802 1P and DSCP priority operations their priority values can be mapped to four priority queues on each port of the switch for QoS operation 1 QoS Information QoS Em C Enable visable Any Port Number 1 2 3 4 5 6 Zp 8 9 10 Low c Lol ol c c c Normal c o Medium c e Cj Addresses Table High o o 9 e EC Spanning Tree mis mg VLAN EHE 005 2 a Tome Mods Port Number 1 2 3 4 5 6 TA 8 9 10 8 le Stating On e o e e IGMP Off c o c ol ol c c EC Ai aE Tools Port Number 1 2 3 4 5 6 4 8 9 10 On o o Off 3 c 3 c 3 3 3 3 3 3 Beas QoS this is for QoS function enable disable Port Priority this is used to define the priority setting of each port It will map to the four priority queues of the switch 802 1P Enable this is for 802 1P priority operation enable diable on each port 802 1P priority operation will use the priority setting in tag of packets for QoS operation The mapping of 802 1P priority values 0 7 to priority queue could be defined at VLAN Tag Priority page by clicking Configure VLAN Tag Priority button DSCP Enable this is for DSCP Differential Service Code Point priority operation enable disable on each port DSCP priority operation will use t
90. l be deleted from ARL table after some time when users do not send any packets to the switch This operation is called aging and the time is called aging time It is about 5 minutes normally it could be changed by users If users want to keep a Mac address always in ARL table on some port they can assign the Mac address to ARL table These Mac ID are called Static Mac address This switch supports static Mac address assignment The static Mac address assignment will also limit the Mac address could be used on the assigned port only with the port security configuration function For example assigning 00 00 e2 11 22 33 to Port 5 will always keep this Mac ID alive on Port 5 but also limit this Mac address could work on Port 5 only Note About Static Mac Address Filter in port binding function There is Mac Security Configuration function for port security If it is set to Accept function only these static Mac addresses can access network through the assigned port The other Mac addresses will be forbidden for network access through that port This function can be used for port binding security application Please refer to Section 6 3 for the details of the Mac address filter in operation of the switch 7 Dynamic Mac ID Number Limit Beside Static Mac ID Limit there is another Dynamic Mac ID Number Limit function for Mac address security on port This function can limit the Mac ID number to access network through a port For example fi
91. le Disable IGMP Querying C Enable Disable Seem Unregistered gt iino IPMC Flooding Enable 6 Disable Gi 125 ci 60 125 PE Addres Tale IGMP Query Interval seconds 60 125 C Spenning IGMP Report Delay 15 seconds 5 25 5 VLAN IGMP Query Timeout 255 seconds 255 500 ib Port Number ame pr Ee Ee Ee E EC T M oono op nnn nn p 18 IGMP cenfipenson IP Molicert Registre An 8 MYR VLAN 18 MYR GROUP H Tek SE DHCP Rehy 900 Took 1 IGMP Configuration IGMP Status this is used to enable disable IGMP function IGMP Querying this is used to enable disable IGMP Query function This switch will send IGMP Query at a fixed interval if it is enable The IGMP query responses known as IGMP reports which look very much like an IGMP join keep the switch updated with the current multicast group membership on a port by port basis Unregistered IPMC Flooding unregistered un joined IP multicast traffic will be flooded to every port if this setting is enable If it is disable the unregistered IP multicast traffic will be flooded to IP multicast members only IGMP Query Interval this is used to set the IGMP query packet sending interval if IGMP Query function is enable IGMP Report Delay this is used to set the delay time to send report after receiving a query When a host receives a Query it doesn t send a report immediately but it starts a report del
92. management PC Backup Setting to text file Clicking this button the switch will backup the configuration of the switch to the web management PC in text format Restore Setting The configuration of the switch can be restored to switch by clicking this button after the configuration file is selected Restore Factory Default This function will restore the switch configuration to factory default setting Reset System This function will cause the switch to reboot itself 2 Ping 126 Ping Parameters EIS Sytem P SNMP 1 Se unty wg Pod C Addres Tob Hg Speumag Toe VLAN DEY Qs sg ome 2 Tmk Gy Took s Tool information a This function is used to ping network devices from the switch It can be used to verify network connection Target IP address This is the target IP address for the ping operation Count This is the repeat count for the ping operation Time Out This is the timeout value for the ping operation After the above items are set click Apply to start the ping operation Then the result of ping operation will be shown 127 7 Software Update and Backup This switch supports software update and configuration backup update restore functions It could be done in two ways 1 From console when booting by Xmodem protocol and doing by terminal program This function can be used for run time code and boot code updating Boot code works only at boot time before the main p
93. mand This command is used to show port mirror function setting show port monitor command is used to show port mirror function setting For example show port monitor Mode Disable Destination port 1 Source port 70 19 show queue command This command is used to show traffic scheduling settings for priority queues on ports show queue bandwidth Shows weighted round robin WRR bandwidth mode Priority queue information show queue bandwidth command is used to show weighting of priority queues for bandwitdh sharing of WRR operation show queue mode command is used to show traffic scheduling mode for priority queues is Strict Priority higher priority always get bandwidth service first another is WRR Weight Round Robin bandwidth is shared between priority queues with weighting For example show queue bandwidth Queue Scheduling WRR Setting Table Priority Weight Traffic Class 0 1 Traffic Class 1 2 Traffic Class 2 4 Traffic Class 3 8 show queue mode Queue mode Strict 20 show radius server command This command is used to show settings for RADIUS Server of 802 1x function For example show radius server Redius Server Configuration Menu Redius Server IP Address 192 168 1 222 Redius Server Port Number 1812 Security Key 12345678 21 show running config command This command is used to show current running configuration of the switch For example show running config Ibuild
94. mand is used to setup the management interface security function The management interface security function can limit the IP subnet remote interfaces http telnet esnmp access right view modify for management from network Different administrators could have different rights to manage this Switch This is for security of this management switch Four user groups are supported for this function Entering management the sub commands will be shown config management 1 4 Index config management 2 enable Set enable for a specified set ipaddr Set IP and net mask for a specified set mode Set mode for a specified set protocol Set protocol for a specified set management x enable command is used to enable the security settings for some user groups x is the index of the user group And no management x enable command can be used to disable it And users for this setting are allowed to manage this switch remotely management x ipaddr y y y y z z z z command is used to set the IP subnet for some user groups x is the index of the user group y y y y is the IP address 2 2 2 2 is the IP subnet mask Users in this IP subnet will belong to this users 36 groups management x mode modify view command is used to set the access right for some user groups x is the index of the user group If management x mode modify command users in this groups have modify right for management If management x mod
95. n ip IP information ip filter IP Filter Configuration lacp LACP statistics line TTY line information log Log records mac address table Configuration of the address table mac security MAC Security Configuration management Management IP filter map Maps priority mvr Show MVR Status port Port characteristics queue Priority queue information radius server RADIUS server information running config Information on the running configuration rate limit Configures rate limits snmp Simple Network Management Protocol statistis sntp Simple Network Time Protocol configuration spanning tree Spanning tree configuration system System information trunk Trunk information version System hardware and software versions vlan Virtual LAN settings 1 show aaa authentication login command This command will show the authentication settings for admin of the switch when login for management t could be authenticated by local switch or RADIUS Server or local switch first RADIUS Server next For example show aaa authentication login Authentication local 61 2 show calendar command This command will show current system time For example show calendar Current Time 2008 08 29 11 27 12 3 show dhcp relay command This command will show current DHCP Relay Option 82 settings For example show dhcp relay DHCP Relay Configuration DHCP Relay Status Disable Add additional option82 information Disable Relay Agent information DHCP Server IP Address
96. n transfer data to each other The network traffic will be blocked if they have different VLAN ID VLAN Stacking function for 802 1Q tag based VLAN is supported It allows two VLAN tags in a packet for 802 1Q VLAN tunneling application through a central network 2 Trunk If two switches are cascaded together the bottleneck will happen at the cascading connection If more cables could be used for the cascading connection it will reduce the bottleneck problem In normal case switches will become unstable because of traffic looping when more than one cable is connected between them If the switches support trunk function they can treat these cables as one connection between them The traffic looping will not happen between these cables and the switches will work stable with bigger bandwidth between them Notes About redundant application The trunk connection supports redundant function If any trunk cable is broken the traffic going through that cable will be transferred to another trunk cable automatically For example if traffic of user port Port 6 is assigned to Port 1 in a Trunk and Port 1 connection breaks Port 2 will take over the traffic for Port 6 automatically It could be used for redundant application 3 Spanning Tree Protocol Rapid Spanning Tree Protocol Spanning tree is a protocol to prevent network loop in network topology f network loop happens it will cause switches in the network unstable because more and more tra
97. nd forward 8K entries Line speed 9600 Bytes 802 3x for full duplex backpressure for half duplex 802 1Q VLAN Port based VLAN Private VLAN Yes 4 transmit priorities per ports for port based 802 1P tagged based DSCP priority operation Support RSTP STP protocol 8 groups max Static and LACP are supported Yes Yes for IP multicast traffic Yes Static Mac address access limit on port and Dynamic Mac address number limit on port Yes IP Subnet access filter function by port Yes support Authentication and Transparent modes Guest VLAN and Dynamic VLAN are supported Yes support DHCP Relay Option 82 function Yes 128Kbps 1000Mbps for ingress egress traffic Broadcast Multicast and Unicast Storm Control Yes by IP Subnet Protocol interface limit Yes by NTP protocol Yes Local and Remote by syslog logging Console http s telnet and SNMP 131 SNMP v1 v2c v3 agent support MIB II Bridge MIB 802 1Q MIB and Private MIB Software Update Backup by http TFTP protocols Xmodem for firmware configuration binary text 132 B Compliances EMI CertificationFcc Class A Certification USA Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules whi
98. nds will be shown config ip default gateway Specifies the default gateway http HTTP server configuration 33 igmp IGMP protocol ip default gateway x x x x command is used to specify the default gateway for IP configuration of the switch x x x x is the IP address of the gateway device ip http command is used to configure http service of the switch Entering ip http the sub command will be shown config ip http Secure server Enable secure HTTP server server Enable HTTP server ip http secure server command is used to enable the SSL function of http service https of the switch And no ip http secure server command can be used to disable it ip http server command is used to enable http service of the switch And no ip http server command can be used to disable it Because hacker or worm virus like ColdRed often attacks http server this command is provided to enable disable http service to prevent it If this Switch is installed in public Internet without any firewall protection we suggest users to disable the http interface and use Telnet or SNMP instead ip igmp command is used to configure IGMP operation of the switch Entering ip igmp snooping the sub command will be shown config ip igmp snooping mrouter Multicast router query Enable IGMP query function query interval Configures query interval query max response time Configures the report delay router port expire time Configures router port e
99. nfiguration For example show ip interface IP address and netmask 192 168 1 12 255 255 255 0 on VLAN 1 show ip redirects command will show current IP gateway setting of the switch For example show ip redirects gateway 192 168 1 254 9 show ip filter command This command is used to show current IP Filter function status of the switch show ip filter IP Filter Configuration IP Address Filter Disable For showing filter IP address show interface switchport command will show port settings one after another And show interface switchport ethernet 1 x command will show Port x settings 65 10 show lacp command This command is used to show current LACP configuration of the switch show lacp internal Shows config settings operational state for local side portstatus Shows LACP Port Status Sysid Shows channel groups system priority MAC address show lacp internal command is used to show system priority and protocol enable disable status of ports show lacp internal Lacp Port Configuration System Priority 65535 Port Protocol Enabled Eth 1 1 Disable Eth 1 2 Disable Eth 1 3 Disable Eth 1 4 Disable Eth 1 5 Disable Eth 1 6 Disable Eth 1 7 Disable Eth 1 8 Disable Eth 1 9 Disable Eth 1 10 Disable show lacp portstatus command is used to show LACP working status of ports show lacp portstatus LACP Port Status Port Protocol Active Partner Port Number Operational Port Key 1 no 2 no 3 no 4 n
100. nfiguration about it show mac address table aging time Aging time for entries in the address table address Address information interface Ethernet or port channel interface multicast Knowns multicast addresses cr 67 show mac address table command will show mac address table content For example show mac address table Interface Address VLAN Eth 1 3 00 00 01 00 00 20 Learned Eth 1 3 00 0E A0 00 03 28 Learned Eth 1 3 00 90 08 7 76 6 Learned Eth 1 3 00 0 6 01 11 40 Learned Eth 1 3 00 80 C8 BF 10 D2 Learned Eth 1 3 00 0 6 01 15 87 Learned Eth 1 3 00 90 CC 82 A5 D6 Learned Eth 1 3 00 00 2 82 8 6 Learned show mac address table aging time command will show aging time of mac address table For example show mac address table aging time Status Enable Aging time 300 sec show mac address table address x x x x x x command will show the mac address table for mac address For example show mac address table address 00 00 e2 82 8c e6 Interface Address VLAN Eth 1 3 00 00 E2 82 8C E6 Learned show mac address table interface ethernet 1 x command will show the mac address table for Port x is the port number For example show mac address table interface ethernet 1 3 Interface Address VLAN Eth 1 3 00 00 01 00 00 20 Learned Eth 1 3 00 90 CC 82 A5 D6 Learned Eth 1 3 00 00 E2 82 8C E6 Learned Eth 1 3
101. ns This is the forwarding transition counter on the port Port Role It is the role of the port for the STP operation It could be Root Designated Backup or Alternated If the port is link down the port role will be Nonstp Point To Point This is a Point to Point link on the port 103 6 4 7 VLAN This switch supports 802 1Q VLAN Port based VLAN and Private VLAN 1 802 1Q VLAN 1 1 802 1Q VLAN 802 1Q Virtual LAN 000 Hons BS nave HG System C Enable amp Disable EC SNMP QQ Security Port CJ Addresses Table H Spanning Tree EMEg VLAN SS 802 10 VLAN s BOZIQYLAN 8 VLAN Tag Rules g Static 1Q VLAN Frame Control Ce No Drop amp ol Ce cl cl c c Drop o ET Port VLAN ID Setting NOTE Changing Port VID will put ports to different VLANs Check Management VID setting in IP Configuration to prevent management connection break SE Private VLAN SSH i fr In i 19 Port Based VLAN eds 3 80210 VLAN This is used to enable disable 802 10 VLAN function GVRP The GVRP protocol can learn remote 802 1Q VLAN on other switches and add to dynamic 802 1Q VLAN table You can enable disable the operation of this protocol Ingress Filter This is used to enable disable doing VLAN filtering function at ingress port If itis enable the ingress port m
102. nterface ethernet 1 x command is used to configure settings for Port x Please refer to section 6 2 4 1 Interface Configuring Commands for Port for the details interface vlan x command is used to configure VLAN Group x interface x is the VLAN ID Please refer to section 6 2 4 2 Interface Configuring Commands for VLAN for the details Both commands will change the prompt from config to config if Note The general VLAN settings are done with vlan database command Please refer to section 6 2 5 VLAN Configuring Commands for the details And interface vlan x command is used to assign characteristics to a VLAN interface For example assigning IP address to a VLAN interface is done with this command 6 2 4 1 Interface Configuring Commands for Port Commands in Configuring Mode are for general switch settings And its prompt is config If the settings are for ports it is done with interface ethernet 1 x command in configure mode For example interface ethernet 1 5 is for settings on Port 5 Some syntax are supported for port selection 1 interface ethernet 1 x and x is port number All the settings after this command will be applied to this port For example interface ethernet 1 5 and all the settings after this command will be applied to Port 5 2 interface ethernet 1 x y z and y z are port number All the settings after this command will be applied to these ports
103. o 5 no 6 no 7 no 8 no 9 no 10 no show lacp sysid command is used to show system ID of the switch for LACP protocol show lacp sysid 65535 11 show line command This command is used to show current console line configuration show line console command is used to show current console line configuration show line console 66 Password threshold open end time Baudrate 9600 Databits 8 Parity 0 0 1 2 3 NONE EVEN ODD MARK SPACE Stopbits 1 12 show log command This command is used to show current system log and system log configuration show log configuration logging configuration lt cr gt show log command is used to show current system log content For example show log 5 Thu Jan 01 09 00 02 1970 Level 4 System Started port 0 4 Thu Jan 01 09 08 20 1970 Level 4 Link down port 8 3 Thu Jan 01 09 07 50 1970 Level 4 Link up port 8 2 Thu Jan 01 09 07 45 1970 Level 4 Link down port 8 1 Thu Jan 01 09 00 06 1970 Level 4 System Started show log configuration command is used to show current system log configuration For example show log configuration System Log System Log Status Enable Log Level 0 7 7 Remote Log Disable Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty Remote Log Server IP Empty 13 show mac address table command This command is used to set Mac address table and co
104. oes not support relay between different IP subnets But it supports relay cross VLANs DHCP Relay function can relay DHCP requests to a specified DHCP server And Option 82 function will add the following information to DHCP request packet 1 Port number that DHCP request packet comes from 2 VLAN ID for this DHCP request 3 Mac address of the switch 4 additional string as information Adding the information string must be enabled first And DHCP server will assign IP configuration according to the information in Option 82 Note Not every DHCP server supports Option 82 function If DHCP server does not support it please disable this DHCP Relay Option 82 function 30 Here is the Option 82 definition of the switch 1 Circuit ID sub option setup information for DHCP server Format Slot ID 1 Byte Port ID 1 Byte VLAN ID 2 Bytes Information X Bytes Slot ID plase set to 0 Port ID please set according to the port number of the switch VLAN ID please set according to its VLAN ID Information this is a string with variable length For example 000500 8 means Slot ID 0 Port 5 VLAN ID 200 no information All of the numbers are hexadecimal numbers 2 Remote ID sub option setup information for DHCP server Format Mac Address 6 Bytes Mac Address this is the Mac Address of the switch For example 000000828 6 in hexadecimal numbers If the Option 82 of DHCP request meets these s
105. on for the switch Location this is the location information of the switch SNMP Communities Get this is the community string of GET command for SNMP operation GET command is used to read switch configuration information Set this is the community string of SET command for SNMP operation SET command is used to set switch configuration Locabon Community Name 23 Home Er C System SET praw a SNMP Security mm Address Name 0000 Ded 2 CJ Addresses Table HE Spanning Tree 0000 pex Die v HE VAN 0000 peli Diae E 0000 Deae HI IGMP 0 Trunk 8 DHCP Relay Agent Opt m aran comme er E 713 C Toots 84 SNMP IP Trap Manager Trap function will send notice message to SNMP management station when some events happen Up to five SNMP management stations are supported for Trap function The community string and enable disable setting for each trap are set here User Information This is used to configure SNMPv3 administrator settings The default user name is admin The security level and authentication manner could be configured here The default encryption for privacy is by DES The security level could be noauth no authentication no encryption auth do authentication no encryption priv do authentication and encryption by DES The authentication manner could be MD5 or SHA 85 6 4 3 Security This functi
106. on is used to configure security functions of the switch Those security functions are Administrator Management Security Mac ID Access Security and 802 1x Authentication Security 1 User Accounts Administrator Management Security Admin Configuration Old Username 3 Old Password Home IC System New Username snmp New Password BS Secunty Confirm Password 8 User Accounts Arny 19 MAC Security Config C IP Fifter Username OLY Port Password guest Addresses Table CY Spanning Tree VAN 005 IGMP Login kal BE Trunk E Administrator Username Password This is for network administrator to change his her username and password Default is admin admin Guest Username Password This is used to setup the username password of guest right user who just can view the setting of the switch Authentication This is used to setup the authentication manner for administrator of the switch when login by http s telnet for management It could be authenticated by local switch or by RADIUS Server local authenticated by local switch radius authenticated by RADIUS Server A local radius authenticated by local switch first If authentication fail try by RADIUS Server next RADIUS Server is set in 802 1x function Security Policy Guest Username Password Username guest Password guest 8 Home C System SE sme Authenticat
107. oot switch The prompt is xxx for admin user and gt for guest user 2 Configure Mode Commands With configure command user can enter Configure Mode Commands in Configuring Mode are for general switch settings And its prompt is config 3 Interface Configuring Commands for Port VLAN Group If the settings are for ports it is done with interface ethernet 1 x command in 22 configure mode And the prompt will become config if For example interface ethernet 1 5 is for settings on Port 5 If the settings are for VLAN group it is done with interface vlan command in configure mode And the prompt will become config if For example interface vlan 100 is for settings on VLAN 100 VLAN Configuring Commands If the settings are general VLAN settings it is done with vlan database command in configure mode And its prompt will become config vlan 23 6 2 2 General Basic Commands When admin admin is used for username password the console will enter administrator mode Enter command list will be shown exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands reload Halts and performs a warm restart show Shows information calendar Data and time information configure Enter configuration mode
108. opies run time firmware copy binary config running config tftp xxx xxx xxx xxx yyy command is used to backup current switch running configuration to TFTP Server at IP XXX XXX XXX XXX as file name yyy in binary format copy binary config tftp running config xxx xxx xxx xxx yyy command is used to restore binary configuration file from TFTP Server at IP XXX XXX copy config running config tftp xxx xxx xxx xxx yyy command is used to backup current switch running configuration to TFTP Server at IP XXX XXX XXX XXX as file name in text format copy config tftp running config xxx xxx xxx xxx yyy command is used to restore text configuration file from TFTP Server at IP copy firmware running firmware tftp xxx xxx xxx xxx yyy command is used to backup current running firmware to TFTP Server at IP as file name in binary format copy firmware tftp running firmware yyy command is used to update the running firmware file from TFTP Server at IP XXX XXX 27 6 2 3 Configure Mode Commands Entering configure command at console interface the prompt will become configure All the general settings for the switch can be done in this mode If the settings are for ports it is done with interface command in configure mode For e
109. ork functions including VLAN trunking spanning tree mirror port rate limit IGMP and port configuration Console is supported for command line settings Web Telnet and SNMP interfaces are for remote switch management through network IEEE 802 1x is supported for port security application These functions can meet most of the management request for current network 1 1 Package Contents One Gigabit Management Switch One AC power cord for AC power model only One console cable Two rack mount kits and screws 24TX 4SFP model only This user s manual 2 Where To Place the Switch This Switch can be placed on a flat surface your desk shelf or table Place the Switch at a location with these connection considerations in mind switch configuration does not break the rules as specified in Section 3 Theswitch is accessible and cables can be connected easily to it The cables connected to the switch are away from sources of electrical interference such as radio computer monitor and light fixtures There is sufficient space surrounding the switch to allow for proper ventilation the switch may not function according to specifications beyond the temperature range of 0 to 50 degrees C For 24TX 4SFP model you can also install the switch on a 19 rack with the rack mount kits as the picture lt lt Rack Mount Installation gt gt Before rack mounting the switch please pay att
110. p address release command is used to release current IP address got by DHCP Then you can try to get the IP configuration again by ip address renew command no command This command is used to disable a function or restore a setting to factory default of the switch config if no ip Internet protocol For example ip address dhcp command can enable DHCP client function on the VLAN group interface and ip address dhcp command can disable it 57 6 2 5 VLAN Configuring Commands Commands in Configuring Mode are for general switch settings And its prompt is config If the settings are for VLANs it should enter VLAN configuring mode first by vlan database command in configure mode And its prompt will become config Note If the settings for some VLAN group VLAN ID is known it should enter interface configuring mode for VLAN first by interface vlan x command x is the VLAN ID And its prompt is config if It is described in Section 6 2 4 2 Entering vlan database and the prompt will become config vlan database config vlan Enter at the prompt the sub command list will be shown config vlan exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands end Exit from vlan mode 1q vlan Configures 802 1Q VLAN no Negates a command or sets it
111. packet length Configures the maximum packet length of the port mdi mdix Configures the MDI or MDIX of the port mvr Multicast VLAN Registration no Negates a command or sets its defaults port Configures the characteristics of the port port vlan Configures Port Based VLAN power saving Decrease energy consumption qos Configuration of QoS rate limit Configures rate limits shutdown Shuts down the selected interface spanning tree Specifies spanning tree configuration speed Configures speed operation switchport Configures switching mode characteristics 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command 45 This command is used to show all the available commands in this mode 3 history command This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 5 quit command This command is used to quit from console interface It has the same function as logout 6 channel group command This command is used to add the interface port s to a trunk group This is a static port trunk assignment And the static assigned port s will be ignored by LACP protocol channel group x will add the interface port s to the trunk group x x is the trunk group number and its valid value is 1 8 no channel group will remove the interface port s from any trunk group 7 description command This command is used
112. ping x command is used to assign this interface port s to a Primary VLAN And the port type of the interface port s must be promiscuous first x is the VLAN ID of the Primary VLAN and its valid value is 2 4094 VLAN Stacking Q in Q Setting switchport vlan stacking normal command is used to set the port s as normal 802 1Q VLAN port s And the tagged untagged setting will follow the settings in 802 1Q VLAN switchport vlan stacking access command is used to set the port s as access port s for VLAN stacking operation It will strip a tag from tagged or double tagged packets before forwarding It is for downward connection of VLAN stacking operation switchport vlan stacking tunnel command is used to set the port as tunnel 54 port for VLAN stacking operation It will add a tag and allow two 802 1Q VLAN tags in a packet It is for tunnel and upward connection of VLAN stacking operation 6 2 4 2 Interface Configuring Commands for VLAN Commands in Configuring Mode are for general switch settings And its prompt is config y If the characteristics are for VLAN group it is done with interface vlan command in configure mode For example interface vlan 100 is for characteristics settings on VLAN 100 Note The general VLAN settings are done with vlan database command Please refer to section 6 2 5 VLAN Configuring Commands for the details And interface vlan x command is used to assign characteristics to a
113. ply If time is got from Time Server it will be shown at Current Time For such application you have to get the IP of Time Server from your network administrator first b Set time manually This switch can count time internal You can select Get Time by Manually and input current time manually Then click Apply 81 About Daylight Saving Time Daylight Saving Time function will set the system time one hour early than normal time in a period of time Start Time and End Time can be used to set the time period 4 Log Configuration men System Log Setting Log Setting d Cy Home System Log Status Enable Disable TA System Log Level 0 7 7 9 System Information Remote Log O Enable Disable 8 IP Configuration IS Time Configuration Remote Log Server IP 1 923 Log Remote Log Server IP 2 8 Remote Log Server IP 3 Log Table A TA Remote Log Server IP 4 wy SNMP GC Security Remote Log Server IP 5 amp Port Apply HG Addresses Table BMC Spanning Tree HE VLAN m 005 IGMP GC Trunk Users can configure System Log function and view log records here If this function is enabled the switch will record events to a log file and put the log file to flash Up to 512 records are allowed for local logging f more than 512 events happen the records will be overwritten from beginning And if remote syslog server is applied the switch will also s
114. queue the sub commands will be shown config queue bandwidth Assigns WRR weights to QoS priority queues mode Assigns priority queues queue bandwidth x y z command is used to set the weighting of Normal Medium and High priority queues for WRR operation Low priority queue is always weight1 x is the weighting of Normal priority queue y is the weighting of Medium priority queue z is the weighting of High priority queue And their valid number is 0 3 0 weight1 1 weight2 2 weight4 3 weight8 queue mode strict wrr command is used to select the traffic scheduling mode If strict is selected the higher priority queue always get bandwidth service first If wrr is selected bandwidth is shared between queues with their 39 weighting 26 radius server command This command is used to configure the settings for RADIUS Server The settings will be used in 802 1x operation Entering radius server the sub commands will be shown config radius server host Sets the port as a host port key Sets the RADIUS encryption key port Sets the RADIUS server network port radius server host x x x x command is used to set the IP address of RADIUS Server for 802 1x operation x x x x is the IP address radius server key xxx command is used to set the security key to handshake with RADIUS Server is the key string radius server port x command is used to set the communication port of RADIUS Server
115. rogram starts Press Ctrl C when the switch is booting the following message will be shown Boot Menu 0 Start the Run time code 1 Upgrade Run time code 2 Upgrade Boot Code gt Select a Start Run time code This option will continue the booting process b Upgrade Run time code This option will try to update run time code main code from terminal program with Xmodem protocol If this option is selected the following message will be shown Waiting to receive file by Xmodem Then user can select Send File function of terminal program and select Xmodem protocol and the update file then start the file upgrade c Upgrade Boot Code This option will try to update boot code from terminal program with Xmodem protocol User can select Send File function of terminal program and select Xmodem protocol and the update file then start the file upgrade 2 From web browser Doing by http protocol and by web browser Please refer to the description of Tools function in Section 6 4 12 3 From console telnet command Doing by tftp protocol and done by copy command Please refer to the description of command in Section 6 2 2 128 A Product Specifications Access Method Standards Conformance Communication Rate MDI MDIX Indicator Panel Number of Ports Dimensions Certification Temperature Humidity Bridging Function Switching Method Address Table Filtering Forwarding Rate Maximum Packe
116. s Port channel Eth1 1 s Eth1 2 s Eth1 3 s Eth1 4 s show vlan private vlan command is used to show Private VLAN settings For example show vlan private vlan Private VLAN Port Configuration Port Port Type Primary VLAN Community VLAN Isolated VLAN Eth 1 1 Normal none none none Eth 1 2 Normal none none none Eth 1 3 Normal none none none Eth 1 4 Normal none none none Eth 1 4 Normal 100 none none Eth 1 6 Normal none none none Eth 1 7 Normal none none none Eth 1 8 Normal none none none Eth 1 9 Normal none none none Eth 1 10 Normal none none none show vlan port based command is used to show Port based VLAN configuration For example show vlan port based Port based VLAN Configuration Port based VLAN Disabled VLAN Port List 76 6 3 About Telnet and SNMP Management Interfaces 6 3 1 About Telnet Management Interface If you want to use Telnet to manage the switch from remote site you have to set the IP NetMask Gateway address to the switch first from console Then use telnet lt IP gt command to connect to the switch Its operation interface is the same as console interface 6 3 2 About SNMP Management Interface If you want to use NMS to management the switch from remote site you have to set the IP NetMask Gateway address to the switch and configure the SNMP setting of the switch from console first Then you can use SNMP management program to manage this switch This switch supports SNMP v1
117. s defaults port vlan Configures Port Based VLAN private vlan Private VLAN vlan Switch Virtual LAN interface 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this mode 3 history command This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 58 5 quit command This command is used to quit from console interface It has the same function as logout 6 end command This command is used to exit from VLAN Configuring mode config vlan end config 7 1q vlan command This command is used to configure 802 1Q VLAN characteristics config vlan 1q vlan gvrp Enables GVRP globally for the switch ingress filtering Configures frame filtering base on VLAN membership lt cr gt 1q vlan command can enable 802 1Q VLAN function And no 1q vlan command can disable it 1q vlan gvrp command is used to enable GVRP function of 802 1Q VLAN This command works only if 802 1Q VLAN is enabled And GVRP will be disable automatically when 802 1Q VLAN is set to disable no 1q vlan gvrp command can disable it 1q vlan ingress filtering command is used to enable doing VLAN membership filtering at ingress port instead of egress port no 1q vlan ingress filtering command can disable it 8 no command This command is used to disable a function or restore
118. st 3 Mac address of the switch 4 A additional string as information Adding the information string must be enabled first And DHCP server will assign IP configuration according to the information in Option 82 Note Not every DHCP server supports Option 82 function If DHCP server does not support it please disable this DHCP Relay Agent Option 82 function Here is the Option 82 definition of the switch 1 Circuit ID sub option setup information for DHCP server Format Slot ID 1 Byte Port ID 1 Byte VLAN ID 2 Bytes Information X Bytes Slot ID plase set to 0 Port ID please set according to the port number of the switch VLAN ID please set according to its VLAN ID Information this is a string with variable length For example 000500 8 means Slot ID 0 Port 5 VLAN ID 200 no information All of the numbers are hexadecimal numbers 2 Remote ID sub option setup information for DHCP server Format Mac Address 6 Bytes 124 Mac Address this is the Mac Address of the switch For example 000000828 in hexadecimal numbers If the Option 82 of DHCP request meets these settings DHCP server will assign the IP configuration according to this Option 82 content Here are the setup item in this web page DHCP Relay Agent Option 82 Status is used to enable disable DHCP Relay function Relay Agent Information is the information a string about this agent Check Add information and then
119. st VLAN Qs IGMP 10 e Tmk SE Took 1 2 3 4 HCY Spanning 6 7 8 9 mima mm augamgmnm ub og 0502050 oo se 0109000100009 6 minigmmniaam mms ud ninimajH a digi ud 6 migiagmig ajd 6 09 50090590 9 minimam 0 70 32 DB DIES 4 F 3 4 lz Follow the steps to configure Port based VLAN a Enable Port based VLAN And click Apply button b Give VLAN name c Select ports for each VLAN d Click Apply button Note About Concentration VLAN This is a very popular application for VLAN setting 111 Port Based Virtual LAN Pion ones 0e lz Sg Home ERESERERIEGICESICHERES Hes 1 PE 2 n e n n n n n n n k fet 3 ML DE oem Ti 4 ed p p n g n n n 5 n g f C 5 NW 6 fe E Pure VLAN 7 Me olopolo piole DIDIE S Port YLAN 8 vE npmininininminin miInims c Qu 9 eas 10 J BE Tool 22 Port 10 is the uplink port Port 1 9 are isolated to each other but communicate with Port 10 uplink port 112 6 4 8 QoS This switch supports Port based prior
120. t 1 x rx command is used to add Port x to the monitored port list All the receive traffic from monited ports will be copied to the interface port s x is the monitored port number And no port monitor ethernet 1 x rx command will remove Port x from monitored port list For example port monitor ethernet 1 2 rx command will add Port 2 to the monitored port list and receive traffic to Port 2 will be copied to the interface port s If current setup interface port is Port 5 Port 5 will be the monitoring port port security action command will set the interface port s to accept mode In accept mode only devices PC with static Mac addresses assigned on the interface port s can access network through the interface port s Other devices PC will be rejected port security max mac count x command is used to set the maximum Mac address number allowed on the interface port s x is the maximum number and its valid value is 0 8192 For example x 5 will allow up to five network devices PC access network through the interface port s the port security will be set to this operation mode with this command no port security command can be used to disable the security function on the interface port s 21 port vlan command This command is used to assign the interface port s to a Port based VLAN and set the name description for the Port based VLAN port vlan x yyy command will assign the interface port s to a Port based
121. t Size Flow Control VLAN VLAN Stacking QoS Spanning Tree Trunking Mirror Port IGMP Snooping MVR Mac ID Security on Port IP Filter on Port 802 1x DHCP Relay Rate Control Storm Control Admin Manage Security System Time System Log Out band Management 8TX 2SFP Model Ethernet CSMA CD IEEE 802 3 10BASE T IEEE 802 3u 100BASE IEEE 802 3z IEEE 802 3ab 1000Base 10 100 1000Mbps Full Half duplex auto negotiation Auto detect forced mode is supported LEDs for each unit Power System each port Link Act Green 1000M Yellow 10 100M FDX Col 8 RJ45 TX 2 SFP ports 10 GE Ports totally 250 x 117 x 37 mm CE Mark FCC Class A Standard Operating 0 to 50 1096 to 9096 Non condensing Filtering forwarding and learning Store and forward 8K entries Line speed 9600 Bytes 802 3x for full duplex backpressure for half duplex 802 1Q VLAN Port based VLAN Private VLAN Yes 4 transmit priorities per ports for port based 802 1P tagged based DSCP priority operation Support RSTP STP protocol 8 groups max Static and LACP are supported Yes Yes for IP multicast traffic Yes Static Mac address access limit on port and Dynamic Mac address number limit on port Yes IP Subnet access filter function by port Yes support Authentication and Transparent modes Guest VLAN and Dynamic VLAN are supported Yes support DHCP Relay Option 82 function Yes 128Kbps 1000Mbps for ingress egress traffi
122. te a Community VLAN with VLAN ID VLAN yyy for Private VLAN application private vlan x name yyy isolated command is used to create a Isolated VLAN with VLAN ID x VLAN name for Private VLAN application private vlan x name yyy primary command is used to create a Primary VLAN with VLAN ID x VLAN name for Private VLAN application no private vlan x command can be used delete a Private VLAN x x is the VLAN ID 11 command This command is used to create a 802 1Q VLAN In this command you have to assign the VLAN ID and VLAN name for VLAN creation vlan x name yyy media ethernet command is used to create a 802 10 VLAN with VLAN ID x and VLAN name For example 500 name sales media ethernet will create a VLAN with VLAN ID 500 and VLAN name sales no vlan x command can be used to remove the VLAN with VLAN ID x Note If VLAN x already exists but name is different this command will rename the VLAN 60 6 2 6 Show Commands Show command is put in General Basic Commands for viewing system configuration and information Enter show at the prompt the sub command list will be shown show aaa Show AAA service configuration calendar Date and time information dhcp relay DHCP Relay Configuration dot1x 802 1x content gvrp GVRP configuration history History information interface Interface informatio
123. tem auth control Enables disables 802 1x to change port modes timeout Timeout value 31 transparent Transparent 802 1x packets dotix authcount x command is used to set max count for re authentication request in the re authentication process If the max count is met it will become un authentication state The valid value of x is 1 10 dot1x dynamic vlan command is used to enable Dynamic VLAN function for 802 1x operation If it is enabled the switch will assign the user to the VLAN assigned from RADIUS server And no dotix dynamic vlan command can be used to disable it dot1x guest vlan x command is used to enable and select the VLAN for users fail to authenticated by RADIUS server x is the VLAN ID no dot1x guest vlan command can be used to disable it dotix max req x command is used to set max request timeout count between the switch and RADIUS server before authentication fail The valid value of x is 1 10 dotix re authentication command is used to force re authentication on all ports dotix system auth control command is used to enable 802 1x function on the switch And no dot1x system auth control command can be used to disable it dot1x timeout command is used to setup timeout values in 802 1x operation Entering dot1x timeout the sub command will be shown config dot1x timeout quiet period Time after Max Request Count before gets new client re authperiod Time after connected client must b
124. the MVR VLAN is configured you can assign IP multicast groups video channels to the MVR VLAN in MVR Group page You can assign more than one IP multicast groups video channels to one MVR VLAN Assigning IP multicast groups to MVR VLAN you have to select one MVR VLAN first For an IP multicast group for MVR VLAN you have to assign the following settings Name this is the name for this IP multicast group for identification Start Address this is the start IP multicast address for the IP multicast group End Address this is the end IP multicast address for the IP multicast group Then click Apply After both MVR VLAN and IP multicast groups are configured subscribers at the receive ports can receive IP multicast traffic in the IP multicast groups from Source port even they are in difference VLANs If you want to remove an IP multicast group click Delete The IP multicast group will be removed from the list Note The list does not support edit function If you want to make any modification you have to remove it first Then create the new one 120 6 4 10 Trunk This switch supports up to eight trunk groups And the trunk could be configured with static assigned or by LACP Link Aggregation Control Protocol protocol 1 Trunk Information Trunk enable Disable Sytem Grp amp Member selection HE SNMP 1 2 3 4 5 7 8 9 10 SE Secunty r r n r r r r Port Ae vC
125. to assign a description string for the port s description xxx command will assign a description string for the port s xxx is the string no description command will clear the description string 8 dot1x command This command is used to configure 802 1x function for the interface port s dot1x port control auto command is used to set the interface port s to need dot1x aware client RADIUS server authorization dotix port control force authorized command is used to set the interface port s to grant access to all clients dotix port control force unauthorized command is used to set the interface port s to deny access to all clients dot1x port control none command is used to set the interface port s not to need dot1x operation 46 9 duplex command This command is used to set the duplex mode of the interface port s It could be full duplex or half duplex Note Half duplex is for 10M and 100M speed mode only 1000M speed mode don t support half duplex duplex full command will set the interface port s to full duplex duplex half command will set the interface port s to half duplex 10 end command This command is used to exit from interface mode config if end config 11 flowcontrol command This command is used to enable flow control function of the interface port s flowcontrol command is used to enable flow control function of the interface port s no flowcontrol command is used to disable flow control funct
126. ts from some monitored port to another port for network monitor 94 amp Home System Monitoring Port Monitored Port Mirror HE SNMP WC Security Port Apply Port Configuration Port Information Max Packet Length ior Pout Rate Limit Port Statistics HE Addresses Table EC Spanning Tree mg VLAN Qs lt i gt or D 1616 Mode This is used to enable disable Mirror function Monitering Port This is used to set the capture port The switch will copy the traffic from Monitored Port to this port if Mirror function is enabled Monitored Port This is the monitored port The switch will copy the traffic from this port to Monitoring Port 5 Rate Control Two traffic rates could be controlled by the switch One is the ingress egress traffic of each port Another is Broadcast Multicast Unicast Storm Control 5 1 Rate Control Configuration This function can setup the ingress and egress rate limit of ports Ingress Egress Rate Control Unit N 0 Limit 0 31 ENTE a Apply rs p NOLMIT Port Configemton informsbon Mox Pachet Length Port number Ingress Rate Control Egress Rate Control 1 No Limit No Limit 8 Configurali 2 No Umi No Umit PO fe Lini 3 No Limit No Limit d Rat Control Conti 4 No Limit No Limit 8 Sum Cont 5 No
127. ts valid value is 0 7 y is the prirority queue and its value is 0 3 0 Low 1 Normal 2 Medium 3 High 16 maximum packet length command This command is used to set the maximum packet size allowed on the interface port s For normal Etherent packets the packet size is 64 1514 bytes For some gigabit connections jumbo frame is allowed for higher data transfering efficiency This switch supports up to 9600 bytes packet size 48 config if maximum packet length 1518 max packet length 1518 1532 max packet length 1532 9216 max packet length 9216 9600 max packet length 9600 17 mdi mdix command This command is used to set the MDI MDI X mode of port s This switch supports Auto MDi MDIX function And this command can force it MDI or MDI X mode MDI is for hub switch cascading MDI X is for PC device connecting mdi mdix mdi command is used to set the port s to MDI mode mdi mdix mdix command is used to set the port s to MDI X mode no mdi mdix command is used to set the port s to Auto MDI MDI X mode 18 mvr command This command is used to assign the port s as source port of IP multicast traffic or as receiver port of subscribers for some MVR VLAN mvr x receiver port command is used to set the port s as the IP multicast traffic receiver port of MVR VLAN is the MVR VLAN ID mvr x source port command is used to set the port as the IP multicast traffic source port of MVR VLAN is the MVR VLAN ID
128. ty queues radius server Configures login to RADIUS server rate limit Configures rate limits snmp server Modifies SNMP server parameters sntp Simple Network Time Protocol configuration 38 spanning tree Configures spanning tree parameters storm control Configures storm control trunk Configures trunk function For example mirror command can enable the mirror function and no mirror command can disable it ip default gateway 192 168 1 100 will set the IP gateway of the switch to 192 168 1 100 and ip default gateway will put it to factory default setting 192 168 1 254 23 prompt command This command is used to set the prompt word for console For example config prompt AAA AAA config f 24 qos command This command is used to enable QoS function of the switch And qos can be used to disable it The traffic scheduling mode strict priority ST or weight round robin WRR is selected in queue command And the weighting of each queue is also set in queue command if WRR is selected The other QoS settings on ports are configured in config if mode go with interface ethernet 1 x command x is the port number Please refer to qos command in Section 6 2 4 1 for the details 25 queue command This command is used to select traffic scheduling mode strict priority or weight round robin If WRR is selected weighting of each queue is also set with this command Entering
129. unk function 28 username Establishes user name authentication vlan Switch Virtual LAN interface 1 exit command This command is used to leave current operation mode Go back to last mode 2 help command This command is used to show all the available commands in this mode 3 history command This command is used to show the history of entering commands 4 logout command This command is used to logout from console interface 5 quit command This command is used to quit from console interface It has the same function as logout 6 aaa command This command is used to set the authentication manner for administrator of the switch when login by http s telnet for management It could be authenticated by local switch or by RADIUS Server Here is the command for the setting aaa authentication login local command will set the authentication manner for administrator by local switch when login by http s telnet for management aaa authentication login radius command will set the authentication manner for administrator by RADIUS Server when login by http s telnet for management aaa authentication login local radius command will set the authentication manner for administrator by local switch first when login by http s telnet for management If authentication fail try by RADIUS Server next RADIUS Server is set by radius server command for command line interface or set in 802 1x function for web interface 7 automode command With the
130. unt The re authentication function will re authenticate users after the timeout period The Max Count is the maximum re try count between the switch and users before authentication fail Max Request Count and Server Timeout Period The Server Timeout Period is the timeout period for the request between the switch and RADIUS server The Max Request Count is the maximum re try count between the switch and RADIUS server before authentication fail Supplicant Timeout Period This is the timeout value between the switch and users called supplicant in 802 1x after first identification The valid value is 0 65535 Quiet Timeout Period This is the quiet timeout value between the switch and user before next authentication process when authentication fails Tx Timeout Period This is the timeout value for the identification request from the switch to users The request will be re tried until the Re authentication Max Count is met After that authentication fail message will be sent The valid value is 0 65535 Guest VLAN This function will put those users who are authenticated fail in 802 1x operation to a Guest VLAN The Guest VLAN could be selected here Dynamic VLAN This function will assign user to a VLAN that are indicated by RADIUS Server when 802 1x authentication is pass That is VLAN for users are assigned 89 from RADIUS Server Oe Radius Server IP Address Radius Server Port Number 1
131. used to enable SNTP protocol And no sntp client command can be used to disable it If it is disabled the system time will be got from manual setting sntp server command is used to set the IP address of network time server for SNTP protocol operation is the IP address sntp zone xxx command is used to set the time zone is the location of the time zone With sntp zone the locations will be shown sntp dst command is used enabled Daylight Saving Time function And no sntp dst command can be used to disabled it Daylight Saving Time function will set the system time one hour early than normal time in a period of time start time and end time sub commands be used to set the time period sntp start time w X y z command is used to set the start time of Daylight Saving Time w is the week number in the month Its value is 1 5 X is the day number in the week Its value is 0 6 y is the month number Its value is 1 12 Z is the hour number in the day Its value is 0 23 sntp end time w x y z command is used to set the end time of Daylight Saving 41 w is the week number in the month Its value is 1 5 x is the day number in the week Its value is 0 6 y is the month number Its value is 1 12 Z is the hour number in the day Its value is 0 23 30 spanning tree command This command is used to configure spanning tree protocol of the switch
132. ust be in the same VLAN for packet forwarding If it is disable VLAN filtering function will be done at egress port Frame Control This function could be used to drop non 802 1Q frames untagged packets Port VLAN ID Setting PVID is used to set Port VLAN ID When untagged packet is received PVID of the ingress port will be used as the its VLAN ID PVID is also used as the VLAN ID for tag adding when untagged packet is translated to tagged packet 104 1 2 VLAN Tag Rules Tag Rule Configuration F7 acs s 23 Home gt As s 1 iis 3 eg SNMP in EC Security 4 Access v 1 90 Port 5 fors es Cj Addresses Table 6 Access Cg Spanning Tree 7 Access Eg VLAN Aes s 80210 VLAN 2 cmi 8 80210 VLAN PLANTER 10 Access ligi 1 8 Static 19 VLAN Apply 8 VLAN Table Private VLAN 8 PortBased VLAN Eg Qos HE IGMP igi For 802 1Q VLAN every port could be tag port or untag port Tag port will always send tagged packets and is used for switch to switch cascading It is VLAN trunk connection because there could be more than one VLAN working through it And its role is a Trunk for 802 1Q VLAN groups operation between switches Untag port will always send untagged packets and is used for switch to users connection And its role is a Access connection for users You can define ports as Trunk or Access according
133. ve Mac ID are allowed for Port 2 That means up to five users are allowed but don t care who the users are Itis done by Limit by Mac no option in Mac Security Configuration function 16 8 IEEE 802 1x Port Security Function If the 802 1x function is enabled the switch will act as an authenticator for users accessing network through the switch It will need a RADIUS server for the authentication function Users will be asked for username and password before network access If the RADIUS server authenticates it the switch will enable the port for network access This function is very useful for network security application to prevent illegal users access network through the switch 9 Rate Control This function can limit the traffic rate for physical ports The traffic could be ingress traffic or egress traffic This function can limit the network bandwidth utilization of users 10 Private VLAN Three kinds of VLAN are defined for this application Primary VLAN Community VLAN and Isolated VLAN Community VLAN and Isolated VLAN can communicate with Primary VLAN but they cannot communicate with each other And users in Isolated VLAN cannot communicate with each other This is a special VLAN configuration This switch supports a dedicated configure interface for such application 11 IP Multicast with IGMP Snooping IP multicast function can forward packets to a group of users connected on different ports The user group is learne
134. w the rules in table to setup the maximum storm rates Note The storm rate is counted by pps packet per second 6 Port Statistics Statistics Destination Port Refresh Interval 5 60 secs 30 Home 2 Rx Counter Statistics irn 22 Good Unicast Frame 4383 2 Good Broadcast Frame 315 li a Good Multicast Frame 13 B Bl Discarded Frame 9 Port Configuration Errore S 8 Port Information Total Receive Byte Count 555273 S Max Packet Length Tx Counter Statistics Miror Port Contigurst Good Unicast Frame 4416 m Good Broadcast Frame 8 HE Rate Limit 3 Good Multicast Frame 0 4 forshisies Discarded Frame EM Addresses Table UT 0 EC Spanning Tree Total Transmit Byte Count 1113468 Eg 905 lt gt Port statistics counters could be read here Select a port to get its counters Refresh The counters will be refreshed automatically You can modify the refresh interval And you can click Refresh to refresh the counters immediately Reset Counters Click Reset Statistics can reset the counters to 0 97 6 4 5 Address Table These are functions about Mac address table They are Static Address Assign Dynamic Address Table and Aging Time Setup 1 Static Addresses Static Address Table cies Ne pr NOTE When 802 1Q vlan is disabled vid always is 1 ma Citi Bg Sytem XX XX XX XX XX XX 133494
135. witch one is administrator mode privileged mode another is guest mode normal mode administrator mode The default user name and password is admin admin After login the switch a prompt will be shown Because this switch supports command line for console interface you can press to check the command list 19 first 20 With command you can find the command list as follow exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping Sends ICMP echo packets to other network nodes quit Quit commands reload Halts and performs a warm restart show Shows information calendar Data and time information configure Enter configuration mode copy Copies from one file to another These are the basic system commands for the switch For system configuring configure command can enter the configure mode And the prompt will become configure xxxx config In the configure mode the general configuration of switch can be done And exit command can leave this mode If settings for port interface command is used And the prompt will become xxxx config interface ethernet 1 5 xxxx config if ethernet 1 5 means Ethernet interface 1 port 5 And exit command can leave this mode interface command has another sub command vlan IP address of the switch can be configured in this mode xxxx
136. xample interface ethernet 1 5 is for settings on Port 5 and interface ethernet 1 5 6 10 15 is for settings on Port 5 6 10 11 12 13 14 15 Please refer to next section for the details of this command Enter at the prompt the sub command list will be shown config exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect quit Quit commands aaa AAA Service automode Set Auto Negotiation or Auto Detect mode default Restore to factory default setting dhcp relay DHCP relay setting dot1x Configures 802 1x port based access control end Exit from configure mode hostname Sets system s network name interface Enters privileged interface configuration ip Global IP configuration sub commands ip filter Enable IP address filtering function lacp Configures LACP status logging Modifies message logging facilities mac address table Configuration of the address table management Specifies management IP filter mirror Configuration of mirror mvr Multicast VLAN Registration no Negates a command or sets its defaults prompt Sets system s prompt qos Configuration of QoS queue Assigns priority queues radius server Configures login to RADIUS server rate limit Configures rate limits snmp server Modifies SNMP server parameters sntp Simple Network Time Protocol configuration spanning tree Configures spanning tree parameters storm control Configures storm control trunk Configures tr
137. xpire time unregflood Enable IGMP unregister flood function Cr ip igmp command is used to enable IGMP function of the switch And no ip igmp command can be used to disable it ip igmp snooping mrouter ethernet 1 x command is used to set the port that connecting to the IP Multicast router the IGMP active device is the port number ip igmp snooping query command is used to enable the IGMP query function And no ip igmp snooping query command can be used to disable it ip igmp snooping query interval x command is used to set the IGMP query time interval if query function is enabled is the time interval and its valid value is 60 125 ip igmp snooping query max response time x command is used to set the maximum response time for query operation x is the time interval and its valid value is 5 25 ip igmp snooping router port expire time x command is used to set the time interval of router port expire time x is the time interval and its valid value is 255 500 ip igmp snooping unregflood command is used to enable IGMP unregister traffic flooding function And no ip igmp snooping unregflood can be used 34 to disable it If itis enable the unregistered not joined IP multicast traffic will be flooded to every port If it is disable the unregistered not joined IP multicast traffic will be flood to IGMP member ports only 15 ip filter command This command is used to enable IP Filtering function on port Only the
Download Pdf Manuals
Related Search
Related Contents
Fender Music Mixer Music Mixer User Manual Le publipostage avec Open Office User Manual - RE Connect oneCard RT-1000 - Rontan ZAP LED DMX Manuel d`utilisation Parkside PFS 710 User's Manual Fixapart 1N60 LG LDF900UR User Guide Manual - CaRadio Copyright © All rights reserved.