1. See Maintenance Recommendations on page 6 It is extremely important that proper and sufficient voltage 120V is supplied to the Fountain motor Each Fountain is supplied with a UL and CSA approved C 25 GFI Protected Control Box The Foun tain is to be plugged into the C 25 outlet labeled UNIT and the C 25 plugged into a properly grounded receptacle See C 25 Instructions on page 7 Kasco Fountains are lightweight energy efficient and easy to install and operate We strive to pro duce products that exceed customer expectations We hope you enjoy your Kasco Fountain WARRANTY WARRANTY CLAIM amp RETURN POLICY 1 Year Limited Warranty Kasco Marine Inc warrants this Fountain to be free from defects in material or workmanship except for the ropes power cord and propeller under normal use and service The Kasco Marine Inc obligation under this warranty is limited to replacing or repairing free of charge any defective part within one 1 year from the date of shipment Customer shall pay shipping charges for returning the unit to Kasco or an Authorized Repair Center THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED AND ANY OTHER OBLIGATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE INC AND IN NO EVENT SHALL KASCO MARINE INC BE LIABLE FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES Warranty is void tf e The Fountain is not maintained properly according to the Maintenance Recommendations suppl
2. In warmer regions it is recommended that the motor is re moved and cleaned at least two to three times per year depending on conditions In most cases a power washer will be sufficient if the unit and algae are still wet SEAL AND OIL REPLACEMENT This is a sealed motor assembly and seals will wear out over time similar to break pads on a car Replacement of the seals and a change of oil after three to five years may add longevity to the operation of the motor saving you the cost of more expensive repairs In warmer cli mates where the fountain runs most or all of the year it is a good idea to replace seals more regularly than you would need to in colder climates where the unit is removed from the water for several months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Au thorized Repair Center Any alterations or changes made to Kasco units by an unauthorized source will void the warranty This includes tampering with the unit power cord and or control box Please contact Kasco Marine Inc at 715 262 4488 for your nearest Authorized Repair Center C 25 TIMER CONTROL INSTRUCTIONS Portable Timer with Ground Fault Interrupter Unit 9 8 FLA 58 8 LRA 120 VAC Light 300 W 120 VAC IMPORTANT This portable timer is designed for CONTROLLING the connected equipment only Unplug timer before ser vicing the unit or the equipment it controls THE MANUAL OVERRIDE KNOB IS NOT TO BE USED AS A P
3. OWER DISCONNECT For maximum protection against electrical shock hazard perform test pro cedure on G F C I at least once a month Mount at least 5 ft from open water G F C I TEST PROCEDURE The G F C I should be checked every month to make sure that it is operating properly Just follow the simple instructions below Itis recommended to maintain a maintenance diary of your monthly safety check 1 Push TEST button RESET button should pop out from inner surface This should result in power being OFF at the outlet protected by the G F C I Verify by plugging a test lamp into the outlet Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUT TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROP ERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNICIAN Failure to use the C 25 with Kasco Fountains will void the warranty and cause the Fountain to not be listed to UL and CSA standards via ETL UNDER NO CIRCUMSTANCES SHOULD ANYONE ENTER THE WATER WHEN A UNIT IS IN OPERATION TIMER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON amp OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Contr
4. Sco Marine Inc LOE amp LOOL Aerating Pountalli Onmers Manual Patent Pending lb CONTENTS I Safety Instructions 0 co cc cece cence ee eeen eee eees 2 II General Owner s Instructions 00 c cece eee cues 2 II Warranty Warranty Claim amp Return Policy 4 5 IV Maintenance Recommendations 00000e 6 Ve C225 ISCO esarete E ACCE Aai 7 VI Parts Included amp Tools Needed 0005 8 VII Nozzle Options amp Pattern S1zes 0 ccc eee 9 VIII Replacement Parts amp Assembly Diagram 10 IX Assembly amp Installation Instructions 11 12 X Troubleshooting Tips 0 ccce cece eee e eee eeeeeeens 13 XI Warranty Registration Information 05 14 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Made in the USA Phone 715 262 4488 Fax 715 262 4487 www KascoMarine com sales kascomarine com ROVS SA hanks We at Kasco Marine Inc would like to both thank and congratulate you on your purchase of the 1400JF Aerating Fountain We appreciate you choosing Kasco and for your purchase Your decision to purchase Kasco s 1400JF Aerating Fountain will not disappoint you The 1400JF Aerating Fountain will be a great addition to your body of water It will help improve the water quality by adding much needed oxygen and circulation It will also enhance the aes thetics
5. e system or wrapped around the shaft of the motor especially plastic bags and fishing line Even though Kasco Aerators and Fountains are among the most clog resistant on the market it is impossible to protect against all items that can clog equipment and still maintain a flow of water These materials can be very damaging to the equip ment under continued operation and must be removed as soon as possible ALWAYS UNPLUG THE UNIT BEFORE ATTEMPTING TO REMOVE CLOGS WINTER STORAGE In regions where there is significant freezing in the wintertime the fountains should be removed from the water to protect them from the expansion pressure of the ice In many areas fountains will keep some amount of ice open through the winter However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32 F It is not nec essary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains should be removed from the water at least once per year at the end of the season in cold climates to clean the exterior of the system especially the stainless steel motor housing can The motor housing is the surface that dissipates heat into the water and any algae calcium etc build up will become an insulator that blocks heat transfer
6. eks This is referred to as a Nuisance Trip This usually occurs where the unit is installed a great distance from the initial electric service on the property where the ground stake is placed Itis caused by either induced current in the ground wire or a base voltage difference due to soil pH levels To resolve the problem contact an electrician and install a local grounding stake This will eliminate the induced cur rent and any base voltage differences 14 Fountain Warranty Information Please fill out the enclosed addressed warranty card and mail to Kasco Marine Inc or register your fountain online at www kascomarine com solutions_warranty_registration htm Also fill in the information below and keep for your records Model Ex 1400JF Serial Ex 50J11725 Purchase Date Purchased From How Registered Mailed Card or Registered Online Registration Date Date card sent in or registered online Marine Inc Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com service kascomarine com 884140
7. eline so the ropes are free of slack but not tight To prevent twisting of the unit due to torque you should place the anchor at least 3 feet from the float for each foot of depth Ex A 3 foot deep pond would require an anchor 9 feet horizon tally from the float For ease of removal you may choose to keep at least one anchor within reach from shore just below the water s surface Correct Anchoring gt 5 cae ee nn Ri i 2 ee ee ee ee ee oa if STEP SEVEN ALTERNATE INSTALLATION In ponds where the water level fluctuates signifi cantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so the Fountain can rise as the water level rises This can also help hide ropes by sinking them further below the surface Normal Water Level Anchor Ropa Power Cord i H J A Ile pr a E k e A T ee ee ee a ee ee ee a ft gi L a Se ah pper w 7 eih pa Eic ites Secondary Weight Low Water Level High Water Level E p D N anaa na oi o e i tit ain a E e en j T raf the Toth Sq ma arti e n ea ae F eke a 4 eg ea q ae lt EFi lei a m r D an e i mm i F i i ea aa tea aR ree STEP EIGHT Install the C 25 on the post with the power supply Use up to three 10 x 1 long or longer screws and the molded screw placements on the C 25 NOTE The C 25 mu
8. emove the 4 Upper Pump Housing screws and pull the Upper Pump Housing up Finally re move the 3 8 Fillister head plastic set screw in the top of the 4 Blade Prop Place a slight amount of pressure on the new nozzle when in place and tighten the 1 4 20 x 7 8 Fillister head screw until snug Do not over tighten Diagram B 6 x 3 4 Fillister 1 Self Tapping Phillips Head Screw Osprey Nozzle Head Upper Pump Housing Screws Upper Pump Housing 1 4 20 x 7 8 Fillister Head Screw Eagle s Nest Nozzle STEP FOUR Install the Fountain into the pond lake in at least 12 of water so the unit is floating freely Support the weight of the unit with the ropes and or the float while setting it into the water DO NOT LIFT BY THE CORD Use the nylon tie to secure both cords and an adjacent mooring rope together about 1 foot from the float to prevent twisting or getting caught in the unit Secure the ends of the cords to the post at the power supply so the ends do not get dragged into the water STEP FIVE Determine how to anchor or secure the unit in the pond You may want to use weights at the end of each rope cinder blocks work well and sink them to the bottom or secure the ropes to the shoreline by ty ing them to a stake or placing a rock on top of the ropes 12 STEP SIX Use the ropes to position the Fountain in the desired location in the pond lake Anchor the ropes or secure them to the shor
9. epaired at substantially lower costs than replacement with new Please ship ac cording to the instructions in the previous section Again it is best to call ahead for a Return Authorization Number and or Repair Form so we know the repair is coming Kasco Marine offers free estimates on repairs at the request of the customer The request for estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and or e mail address Estimate options are as follows e We will contact the customer with a total after the unit has been evaluated but before the work is per formed e We will repair the unit only if repair costs are under a stated dollar amount Example Please repair if to tal is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned the unit will be restored as closely as possible to the condition in which it was received and shipped at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned to the customer and billed C O D unless otherwise directed Kasco Marine also accepts Visa and MasterCard credit card payments Kasco Marine will call for credit card infor mation upon completion of the repair at the customer s request All other warranty and repair inquiries should be directed to Kasc
10. flat surface Inspect the shipment for any dam ages If damages are found immediately notify your carrier and your Kasco Marine Inc representative Next cross reference the parts included in the ship ment with the Parts Included sheet in this manual on page 8 Make sure you have all the parts needed If any shortages are found contact your Kasco repre sentative immediately STEP TWO Locate and unwind the two braided nylon ropes in cluded with the shipment There are two molded Rope Holes on opposite sides of the float attached to the fountain assembly Tie one end of a rope to one rope hole with a secure knot Be sure not to leave too much of a tail after the knot Repeat with the other rope on the other Rope Hole STEP THREE Locate the 5 nozzles included with the shipment the Osprey nozzle is already installed on the fountain along with the Upper Pump Housing Using the Nozzle Options diagram on page 9 determine which pattern is desired and the corresponding nozzle If the Condor or Falcon patterns are desired you must remove the Osprey Nozzle by removing the 1 Self Tapping Phillips Head Screw Replace the nozzle with either the Condor or Falcon re insert the 1 Self Tapping Phillips Head Screw and tighten until snug Diagram A If either the Eagle s Nest or Hawk s Nest patterns are desired you must remove both the Osprey Nozzle and the Upper Pump Housing Re move the Osprey nozzle first as above Second r
11. hts free of the propeller by tying the cords and one of the mooring ropes together Note It is extremely important to test the GFI breaker in the control panel upon each installation reinstallation of the unit to ensure proper functioning WARRANTY Kasco Fountains are the result of over 35 years of design and engineering Kasco products are built to withstand the toughest conditions Kasco Marine backs each 1400JF Fountain with a 1 Year War ranty This warranty covers any and all manufacturers defects within 1 year from the date of purchase See Warranty Warranty Claim amp Return Policy on pages 4 amp 5 Please fill out the enclosed ad dressed Warranty Card and mail it to Kasco Marine to start your warranty coverage You may also register your Fountain online at www kascomarine com solutions_warranty_registration htm USE AND OPERATION Kasco Fountains are designed and engineered for continuous duty such as on fish farms or other aquaculture applications or on demand use as needed in a recreational water feature During flotation operation the water is pulled from 360 around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The motor and ball bear ings are submerged in oil and no further lubrication is needed Make sure to keep the motor housing clean from hard water deposits and or algae
12. ied in this Owners Manual e The Fountain is returned for repair without the power cord or if the unit control box or power cord are altered in any way from original shipment Cuts in the power cord are not covered under warranty e The Fountain is damaged by unauthorized tampering Warranty Claim Procedure Check the eight digit serial number printed either on the black cover of the motor or on the blue nameplate and determine the year of manufacture according to the serial number scheme below Sample Serial 50 J 1 1725 e The first two digits represent the reverse of the last two digits of the year of manufacture Example 50 2005 model year e The third digit represents the model Ex J for 1400JF e The fourth digit represents the horsepower of the unit in fourths 1 1 4hp e The remaining four digits are sequential The best method for establishing warranty period is through the warranty card included with the unit at the time of purchase and or the original receipt If the customer has completed and returned the warranty card at the time of purchase or registered the Fountain online at www kascomarine com solutions_warranty_registration htm Kasco Marine will have a record of the purchase and will be able to determine whether or not the unit still car ies warranty coverage Once the warranty coverage has been established the unit may be sent to any Kasco Authorized Repair Center for evaluation and repair P
13. lease call Kasco Marine at 715 262 4488 prior to shipping to receive a Return Authorization Number and or Repair Form then ship to Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Attn Repairs Or call Kasco Marine at 715 262 4488 to locate your nearest Authorized Repair Center You can also email Kasco at service kascomarine com Note Only complete motor assemblies will be accepted for warranty repair The power cord and all other components must be returned with the motor as originally assembled Any missing parts will be replaced at the customer s expense and if determined to have caused the failure could void the entire warranty Some parts are essential for structural support during shipping and others such as the power cord are essential to properly diagnose potential causes of failure It is not necessary to return the control box with the motor as sembly Please include the Repair Form received from Kasco Marine or your local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail address for correspondence regarding the warranty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will re turn units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Most failed equipment can be r
14. lugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the cause of the problem The problem could be one of many such as low water levels build up on the unit to prevent heat dissipation something inhibiting the free rotation of the shaft etc If something is caught in the unit or there is a build up on the unit remove the debris and if caught early enough the unit should be fine Contact a Kasco representative before restarting the unit 6 My Fountain flow seems to fluctuate and or be less than usual This can occur because of a few different reasons Most of the time this symptom is caused from unit being clogged with debris A mat of weeds many leaves plastic bags etc can clog up the unit and cause it to be starved of water If the unit does not have the proper amount of water the flow or pattern will fluctuate up and down and look sporadic If you are seeing these symptoms unplug the unit and clean away the debris that is clogging up the screen Another possibility if these symptoms are noticed is a chipped or damaged prop that is causing the unit to wobble and not pump properly When the unit is unplugged check the prop for damages and replace if damage is found 6 The GFI breaker trips randomly and sporadically Sometimes it is a few hours of operation other times it can be days or we
15. o Marine Inc at 715 262 4488 or returns kascomarine com MAINTENANCE RECOMMENDATIONS Under No Circumstances should anyone enter the water while a fountain is operating Please keep the original box for maintenance shipping The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco Fountain and reduce the need for more costly repair work PROPER INSTALLATION Proper installation of Kasco equipment will include a power source with ground fault interruption For Fountain models the C 25 control 120V included with the unit has built in ground fault interruption that is sufficient Ground fault interrupters are a safety feature that can also alert you to electrical leaks in the equipment Jt is extremely important to test the GFI upon installation each reinstallation and monthly thereafter to ensure proper operation If you have repeat consistent trips on your ground fault the equipment should be disconnected and removed from the water The power cord should be inspected for damage and you should call Kasco Marine at 715 262 4488 for further instructions or email Kasco at service kascomarine com OBSERVATION Operating equipment should be observed on a regular basis daily if possible for any reduction or variation in performance If a change in performance is observed the equipment should be disconnected from power and inspected for any material that may have clogged th
16. of the pond or lake with the 5 interchangeable fountain patterns The lighting package Gf purchased will illuminate your fountain for beauty day and night We thank you for choos ing Kasco for your fountain needs and want you to be completely satisfied with your purchase IMPORTANT SAFETY amp HANDLING INSTRUCTIONS Please read and follow these extremely important safety and handling instructions for your Kasco equipment Following these instructions will help ensure your safety and the quality performance of your equipment e Under NO circumstances should anyone enter the water with the electrical equipment plugged in and or in operation All Kasco 1400JF and 1400JFL equipment is ETL ap proved to UL and CSA standards for safety in water and all fountain models included con trol panels with GFI protection However it is NEVER recommended to enter the water with the equipment in operation e Caution should be used when dealing with any electrical and or moving equipment e NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator e Extreme caution should be used around water especially cold water such as in Spring Fall and Winter which poses a hazard in and of itself e NEVER lift or drag the fountain by the power or light cord If you need to pull the unit to the side of the pond use the anchoring ropes e Do not use waders in deep ponds lakes or ponds lakes with drop offs drastic slo
17. ol Box is to be used with Kasco Approved Lights ONLY 1 Insert ON GREEN and OFF RED trippers into dial at desired ON and OFF times 2 Turn dial clockwise one or more revolutions until correct time of day AM or PM in window is aligned with the arrow 3 Plug aerator fountain cord into the RIGHT hand outlet labeled UNIT 4 Plug transformer light cord into LEFT hand outlet labeled LIGHT FOR TEMPORARY MANUAL OPERATION Rotate MANUAL knob counter clockwise to desired ON or OFF position Timer will follow next auto matic operation PARTS INCLUDED A 1400JF Aerating Fountain Assembled in box 1 NOTE If lights are not purchased or included the cord and Transformer on the left side of the picture will not be included with the shipment B Interchangeable Nozzle Heads Osprey Installed 5 Gr amp O Q Osprey Installed Condor Falcon Eagle s Nest Hawk s Nest 1 2 3 4 5 C Braided 15 Nylon Mooring Ropes 2 D 1 4 20 x 7 8 Long Fillister head screw for Nest patterns 1 E C 25 120V Control Unit 1 F Nylon Cable Tie for securing cords and a mooring rope 1 J awe O N D TOOLS amp SUPPLIES NEEDED Anchors or stakes for installing unit 2 Flat Head Screw Driver Philips head screw driver for mounting C 25 and Transformer if lights are included and installing nozzles 120V Electrical Supply near pond on a post with room for mounting the C 25 and Transforme
18. pes or soft bottom material e Do not use boats that tip easily for fountain installation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device e The fountain is supplied with an internal grounding conductor and a grounding type attach ment plug To reduce the risk of electrical shock be certain that the fountain is plugged into the C 25 Control Box supplied by Kasco and that the C 25 is plugged into a properly grounded grounding type receptacle GENERAL OWNER S INSTRUCTIONS INSPECT THE SHIPMENT Immediately inspect your Kasco Fountain shipment for any visible damages Also cross reference the parts supplied with the Parts Included list to check for shortages Shortages should be reported imme diately to your Kasco Marine distributor or representative and damages reported to your carrier and Kasco Marine CAUTION WARNING Under NO circumstances should anyone enter the water with the unit in operation Always operate the unit in the water and keep people and objects clear of the propeller Do not lift or pull the unit by the electrical cord Always use extreme caution around electrical equipment and wa ter situations ASSEMBLY amp INSTALLATION Please see the proper Assembly and Installation Instructions enclosed in this manual Each is specific for your model and size of Fountain Note Use the nylon tie provided to help keep the power cords for the unit and lig
19. r if lights are included Two 12 pieces of 1 galvanized pipe for weighting ropes optional 6 x 3 4 long or longer screw for mounting the Transformer if lights are included 1 10 x 1 long or longer screw s for mounting the C 25 3 1400JF NOZZLE OPTIONS amp PATTERN SIZES The unique center set design of Kasco s 1400JF Aerating Fountain nozzles offers the best clog resistance and interchangeability available To achieve the pattern you desire simply select the appropriate nozzle according to the accompanying photos and install using the proper bolt or screw into the fountain tube or upper pump housing depending on which nozzle chosen Be sure to snug the bolt or screw to ensure the correct pattern display and size NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes Osprey Produces a wide arch of water 3 5 feet high by 7 feet in diameter To use this nozzle you must have the upper pump housing in place This nozzle has flared outer fins and the number 1 molded on top portion of the noz Zle Comes installed on unit Produces a narrow arch of water 4 feet high by 4 feet in diameter To use this nozzle you must have the upper pump housing in place This nozzle has nearly vertical outer fins and the number 3 molded on the top of the nozzle Produces a narrow V pat
20. roblems etc Try to find out the answers to these questions before you contact Kasco to narrow down the problem How long does it take to trip the breaker Does it always take the same amount of time to trip How many times has it tripped Has there been any electrical problems in the area recently 6 My Fountain seems to run slowly This can also be a symptom of several possible problems There could be an electrical problem where the unit is not getting the proper voltage This could also indicate a problem with the motor of the unit which needs to be looked at by an Authorized Repair Center Check that the unit is receiving the proper voltage and 1f so contact Kasco for further steps 6 My Fountain hums but will not start When I spin the prop with a stick it starts up This indicated a problem with the Starting Capacitor Each Kasco Fountain is equipped with a Starting Capacitor to get the unit going when it is first plugged in If itis operating but not spinning and can be started by spinning the prop with a stick the Starting capacitor needs to be replaced by an Authorized Repair Center 6 My Fountain turns itself off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when 1t overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unp
21. st be hung upright in order to be water proof Install the Low Voltage Transformer if lights are included on the same pole below the C 25 with the one 6 x 3 4 long or longer screw NOTE The Transformer must be hung upright in order to be wa terproof STEP NINE Set C 25 Timer to desired ON and OFF times per the C 25 Instructions on page 7 Make sure to test the GFI using the Test Button located on the outlet be fore turning the equipment on and every 30 days thereafter Plug the 1400JF cord into the C 25 outlet labeled UNIT If lights are included plug the Transformer cord into the C 25 outlet labeled LIGHT STEP TEN Plug the C 25 into the 120V power supply on post and ENJOY YOUR NEW KASCO 1400JF AER ATING FOUNTAIN 13 TROUBLESHOOTING TIPS Below are some helpful troubleshooting tips If a problem occurs please double check the assembly and in stallation instructions as well as the instructions for the proper control panel More troubleshooting tips can be found at www kascomarine com solutions_troubleshooting htm 6 My Fountain trips the ground fault interrupter in the C 25 This is the most common symptom of several possible problems To correctly diagnose the problem you will need to collect more information A Ground Fault Interrupter GFI breaker that trips can 1n dicate an electrical service problem water contamination in the unit and or cord bad breaker control box problems motor p
22. tern of water 3 feet high by 7 feet in diameter This nozzle does not use the upper pump housing It has the number 5 molded near the screw collar of the nozzle Condor Produces a two tiered arch of water with an inner arc 4 feet high by 4 feet in diameter and an outer arch 2 feet high by 10 feet in diameter To use this nozzle you must have the upper pump housing in place This nozzle has flared outer fins and has the number 2 molded on the top of the nozzle Eagle s Nest Produces a wide V pattern of water 3 5 feet high by 10 feet in diameter This nozzle does not use the upper pump housing It has the number 4 molded near the screw collar of the nozzle Upper Pump Housing Must be installed and used with the Osprey Condor and Falcon nozzles Must be re moved to use the Ea gle s Nest and Hawk s Nest nozzles z E HACEN T PARTS amp ASSEMBLY DIAGRAM 4 ITEM Float 1400 Series Light Ring Assembl 140312 Retaining Clip 3 140512 Upper Pump Housing 1 144314 144 20 X 3 25 Long Bolt 3 3 3 4 142212 Nozzle 1400 Series Ospre 476628 1 4 20 X 7 3 Fillister Head Screw 1 mete 144100 1 Self Tapping Phillips Screw t t oa EN ao EE Panes Prop da0 Jr Casa 1420 X38 Fillister 1_ ES EA EE in EA 1 1 1 1 1 1 1 1 1 1 11 ASSEMBLY AND INSTALLATION INSTRUCTIONS STEP ONE Remove all contents from package and place on a clean