Home
D-303486 KF-235 PG2 User Guide EPS
Contents
1. 7 According to the state of the alarm system see section 2 2 3 2 Keyfob Response When executing a command the keyfob s Transmission LED blinks red once to indicate transmission of the command to the control panel If the operation is successfully completed the green LED lights momentarily and a happy tune is heard If the operation fails or cannot be completed for example when the system is not ready the red LED lights steadily and a sad tune is heard When executing a command and there is a communication failure between the keyfob device and the control panel the keyfob s Transmission LED remains off and no tune is heard 3 2 1 Primary LED and Buzzer Response to Keyfob Commands Panel Response Buzzer Indication Transmission LED Indication Blue LED above AWAY button lights Success Operation is successfully completed EME GS Eas Momentary GREEN Happy Success beep Fail Operation failed Za Sad E beep RED No communication For example control panel is out of range None eee None o Keyfob low battery Depends on the operation that is performed Blinks yellow 2 sec Note If transmission is still possible despite the battery condition the unit will send a low battery signal to the control panel Trouble in system Depends on the operation that is performed Lights yellow 2 sec When forced arming bypass zones is performed the keyfob buzzer protests by emitting a continuous tone during the exit delay for 5
2. al Visonic A Tyco International Company Wireless PowerG 2 Way Keyfob User s Guide Mando 2 Vias PowerG Inalambrico Guia del usuario Dispositivo de Chaves Seguidas de 2 Vias PowerG Sem Fios Guia do utilizador 1 INTRODUCTION KF 235 PG2 is a PowerG keyfob for use with the PowerMaster panels Commands are invoked by pressing any of the four command buttons Status is indicated via the Status LEDs and buzzer after every command 2 INSTALLATION 2 1 Enrollment Refer to the PowerMaster panel s Installer Guide and follow the procedure under the 2 Z0NES DEVICES option of the Installer Menu Step 1 Step 2 Step 3 Step 4 Enter the Installer menu and select Select ADD NEW DEVICE Eoo the keyfob by holding the Select the desired Keyfob Number 02 ZONES DEVICES iE for the new keyfob See Note 1 button and release it as soon as as the yellow LED lights or enter the device ID on the back of keyfob 02 ZONES DEVICES gt DADOS cS ENOO gt F02 Keyfob ENTR ID XXX XXXX ID No 301 XXXX MODIFY DEVICES Step 5 Step 6 Step 7 Notes Enter PARTITIONS Assign partitions by pressing the Select Device Settings and see 1 If the keyfob is already enrolled See Note 2 GEME MERN BEED cio io configure tne AUX bution You can configure the keyfob i parameter and assign partitions buttons via the Modify Devices option F02 PARTITIONS FO2 Pig P2 P3m cS F01 DEV SETTINGS cS see Step 2 2 PARTITIONS
3. seconds for more details see the PowerMaster Installer Guide section 5 5 2 3 2 2 Arming LED indication When executing a command using the keyfob device the status of the control panel is indicated by the status LEDs that light blue Exit from DISARM to AWAY AWAY lights 4 MAINTENANCE 4 1 Replacing the Battery When the keyfob device stops operating due to low battery and until the time the battery is completely depleted all LEDs will light blue A replacement 3V battery CR 2032 is available from hardware and electrical supply stores Replace the battery as shown in Figure 2 Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the manufacturer s instructions 4 2 Cleaning Clean the keyfob only with a soft cloth or sponge moistened lightly with a mixture of water and mild detergent and wipe it dry immediately The use of abrasives of any kind is strictly forbidden Also never use solvents such as kerosene acetone or thinner 4 3 Periodic Test Wireless equipment should be tested regularly to determine whether there are sources of interference and to protect against faults Refer to the PowerMaster Installer Guide Chapter 6 Periodic Test for instructions on how to conduct a periodic test 5 TROUBLESHOOTING Problem Diagnosis Proposed actions Keyfob does not enroll 1 Keyfob was pre enrolled 1 Enroll the keyfob again in the vicinity of the control panel
4. 2 The wrong ID number was entered 3 No free location 3 If the maximum number of keyfobs has already been enrolled the alarm system will not allow enrolling any more keyfobs 4 Unknown device 4 Make sure the frequency used for the device is the same as the control panel frequency Keyfob LED does not light when Low battery condition Replace the battery button is pressed 2 Reenter the ID number CAUTION Wireless control panels may be blocked by radio signals occurring on or near their operating frequencies 6 COMPLIANCE WITH STANDARDS Wa liance with Standards Europe EN 300220 EN 50131 1 Grade 2 Class II and EN 50134 2 Class II if used for social alarm EN 301489 EN 50130 4 EN 60950 EN 50131 6 VAC 3 The KF 235 PG2 is compatible with the RTTE requirements Directive 1999 5 EC of the European Parliament and of the Roll eo Council of 9 March 1999 and EN50131 1 Grade 2 Class Il Certified by the Dutch testing and certification body Telefication BV to the following standards 2 D 303486 KF 235 PG2 User s Guide Guia del usuario Guia do utilizador
5. will appear only if gt gt OK PARTITIONING was previously gt means scroll gt and select ok shabledin ihe panel 2 2 Configuring the New Keyfob Template Enter the CESS SMBS menu and follow the configuration instructions for the KF 235 PG2 keyfob as described in the following table Option Configuration Instructions Here you select the function of the button on the keyfob device Options Arm instant default Not Used Status Stop Beeps Skip exit delay and PGM Not Used No function assigned to the AUX button Status Control panel displays and announces the system status Stop Beeps The control panel and other devices in the system stop beeping for example during exit or entry delays Skip exit delay Immediately stops the exit delay and causes the system to arm PGM Activates the PGM output Arm instant While exit delay is in progress this will cause the system to arm instant the entry delay is canceled Applicable only to control panels that support the voice option 3 USING THE KEYFOB 3 1 Keyfob Functionality Step Functions User Actions _ _ ARM DISARM LED Indication E Arm AWAY ES Arm Jam Howe Disarm OFF CALs o a Blue LED above DISARM button lights ef D 303486 KF 235 PG2 User s Guide Guia del usuario Guia do utilizador 1 Step Functions User Actions _ ARM DISARM LED Indication LATCHKEY a PANIC alarm al IE buttons simultaneously 2 sec 4 AUX gt
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL - Pro Audio Centre open - Serrata Philips RC136/17 User's Manual compte personnel de formation Klipsch RF-63 User's Manual - Albalab Fujitsu ESPRIMO P720 E90+ Moscou 5 Maxi Rotators - User Manual Copyright © All rights reserved.
Failed to retrieve file