Home
SARG: Quick user guide - Telescopio Nazionale Galileo
Contents
1. CUMENTS RD1 1 3 ACRONYMS e CCD Charge Coupled Device e GUI Graphical User Interface e SARG Spettrografo ad Alta Risoluzione Galileo e TBC To Be Confirmed e TBD To Be Done e TBW To Be Written e TNG Telescopio Nazionale Galileo e TCS Telescope Control Panel DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 4 9 2 How to start up the system The SARG instrument is essentially composed of a CCD camera and motors to put optical elements Filters Slits and grisms into the optical beam The user will interact with the whole system by the Graphical User Interface choosing an instrument configuration and an exposure time The user will interact with the motors control and with the CCD controller only at the system start up shut down or if a new system initialization is needed In this section l Il describe how to start up and shut down the system If possible ask the support astronomer to do it for you 2 1 1 1 CCD controller The software to operate the CCD controller runs on a Windows PC This computer is located in the control room and share the monitor with another PC On the table there are 2 PC One operates the SARG CCD controller while the second operates the DOLORES one On the desktop of the SARG PC the huge CCD SARG is visible A panel named CCD see Figure 1 should be visible on the desktop and the led at the right of the Connect label on it should be in red not connect
2. DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 1 9 SARG Quick user guide Document TNG SARG OO2 Issue 1 0 Prepared by Name R Cosentino i r Institute INAF FGG Date 23 03 2009 Approved by Name R Cosentino Institute INAF FGG Date Released by Name Institute INAF FGG Date CHANGE RECORD 23 03 2009 First draft draft o 03 04 2009 draft 15 06 2009 a SST DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 2 9 1 IRER ST oases E teen dow ener ns we ees atest E E oath A E ocaeameees 3 1 1 Bre aaa oases ec Sree aan ned eee ed Sedan stew este nue a cee ee tee cde eee ca eine 3 1 2 REFERENCE DOCUMENTS ccccccc ccc c cece cece ee ee teen eee eeeeeeeeneeeneeeeeeeeeeeeneeeneeeueeeueeneeetennennetens 3 1 3 ACRONTM bes eee ements EC OP A ene Ooo eee eee eer ie 3 2 HOW TO START UP THE SYSTEM wiiceveccscvescavesntevdeneweausdnewnd oexenabenvedesw OR E aA 4 2 1 1 1 CCD CONTROLLER ntasitntssdedtaninshacdantedtoenntataddomnssiresabimeandcantedul are bien aa 4 2 2 1 2 HOW TO START UP THE MOTORS AND CCD SERVERS ceccecceccceceeceeeeeuceeueeueeeveneueueeeueeuueeueeveuenenes 6 T2 Sai UP TMS MOLONS serasi Upcaaensevacdpenctsrereesd a dene a e ara EA Ea 6 2 21 Startup Me CCD Serve sarei Ee A dene E A ENTE 6 2 3 TEMPERATURE SERVER ssssssussusnnennnnnnrnnnnnnnn rnnr nann nunan REAREA E AREARE ddan wiwentndune ual man AERAR AR EARRA AR KARRAR annaa 6 RP WEEE a a nate ane ered
3. E E A S 6 2 4 OPEN THE SARGO CUI eaa E E E R N AA EEA 8 2AL See AIO CMS Cl WISE e E E E E E E E teenies 9 3 HOW TO SHUT PROPERLY DOWN THE SYSTEM sisseiceccccccdccsdacds eccevecvacdeentdvecsianteandenwervucsneedecseenacaes 9 3 1 TOP THE Sle EG ara caeusie a cadence tania ans ustna bane dt ease aaah ad einen A dae Wand eeeenanina A 9 3 2 SAUT DOWN CHECK LIST eter ese oe aes tieteacsacdoon pit daa deantoncd a e a eE aa eiA edema E ENS 9 LI ST OF FI GURES Figure 1 CCD program control Window 4 Figure 2 Icon to start up the CCD program control 4 Figure 3 Click on the red circled button to switch on all the sections of SARG The Telescope Control Panel interface program runs on the WLBUILD computer 5 Figure 4 Icon to start up the motors 6 Figure 5 A double click on the Dolores Motors Start Up icon on the LRS linux PC desktop will open this panel Actions to be done here are described in the text 7 Figure 6 A double click on the SARG GUI icon on the LRS linux PC will open the SARG GUI 8 Figure 7 The SARG GUI 8 DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 3 9 1 INTRODUCTION 1 1 SCOPE This is a very short introduction to the SARG instrument control system Here the user will find a brief summary of the operations needed to start up the instrument control system as well as the main features of the interface and others The document is intended as a guide for the general observer 1 2 REFERENCE DO
4. SARG motors and to operate the CCD from the LRS linux PC Before starting the observation the astronomer has to verify if the position of the LRS folding mirror is in SARG position To operate with the folding mirror the DOLORES motor service must be ON To start it up double click an icon named Dolores Motors StartUp on the LRS linux PC desktop The LRS GUI interface will pop up See Figure 5 To move the folding mirror in the SARG position press the Sarg button in the select instrument section DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 7 9 Dolores Motors StarnUp shrutlown LRS Motors Server Start Up Shut Down OFF CCD Server Start Up Shut Down OFF selects Instrument Sarg NONE o SYSTEMINOTINTIAUZED Z Init All Figure 5 A double click on the Dolores Motors Start Up icon on the LRS linux PC desktop will open this panel Sarg Motors startupysnutDown SARG Motors Server CCD Server Init All Show log Figure 6 A double click on the Sarg Motors Start Up icon on the LRS linux PC desktop will open this panel Actions to be done here are described in the text DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 8 9 2 4 Open the SARG GUI The astronomer will send commands to SARG by means of the Graphical User Interface program GUI To start it up double click on the SARG GUI icon
5. ed If this window isn t visible it means that the program to operate the CCD controller is not running Start it up with a double click on the icon Shortcut to CCD See Figure 2 Shortcut bo Lop Figure 2 Icon to start up the CCD program control DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 5 9 Once you are sure that the CCD software is running switch ON SARG from the Telescope Control Panel TOP interface in the WLBUILD computer inside the control room To do that click ON CCD Motors Lamps Slit Viewer buttons The leds at the right of the buttons will change its color from gray to green See Figure 3 This operation will switch on the SARG devices but will not initialize the instrument The Telemetry and LRS Lakeshore buttons must be always ON are password protected E Telescope control panel vw Xx Telescope Control Panel Main Panel Command Panel Mirror Three Mirror Four Power Nasmyth A Control Power Nasmyth B NICS Aopt Nasmyth A M1 Naopt os Bove Selected Selected MICS Bie Pia HE _ on NASM YTHA Power Derotator Nas A mesran onera LRS Lakeshore Adopt Laser orr i Messages Power Derotator Nas B is cecvonic S usec Poder E CoN O ccome SI cosh SR LRS Pressure Clean Figure 3 Click on the red ci
6. rcled button to switch ON all the sections of SARG The Telescope Control Panel interface program runs on the WLBUILD computer DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 6 9 2 2 1 2 How to start up the motors and CCD servers Once having initialized the program to operate the CCD controller and having switched ON the controller you will have to run the SARG Motor Startup Sarg Motors StartUp Figure 4 Icon to start up the motors 1 2 1 Start up the motors On the LRSPC desktop you will find an icon named SARG Motors StartUp A double click on it will pop up the panel shown in Figure 6 On his panel activate the Start Up button on the right of the SARG Motors server label It will activate the motor server program and it will change the color of the led on the right from gray to green The label on it will also change from OFF to ON During the initialization a log window show the initialization processes 2 2 1 Start up the CCD server Again on the panel described in Figure 6 press the CCD Server Start Up button Again the led will change from gray to green and the label from OFF to ON 2 3 Temperature server The temperature server is strictly connected with the telemetry and must be always powered ON The user can shut down this server only if requested by the responsible of the instrument 2 3 1 What to check At this point you are ready to move the
7. see Figure 7 on the LRS linux PC desktop The SARG GUI interface will pop up See Figure 8 To be able to start your first image you still have to open the socket open the the WSS bridge and boot the CCD controller To start this three operations select the option SYSTEM STARTUP under the SARG MANAGER menu Once the boot ends send a dummy bias before to start the calibrations or observations SARG GUI Figure 7 A double click on the SARG GUI icon on the LRS linux PC will open the SARG GUI SARG USER INTERFACE Figure 8 The SARG GUI DOC TNG SARG 002 SARG Quick User DATE 15 June 2009 Guide 9 9 2 4 1 Start Up check list 1 Verify the status of the CCD software in the Windows XP PC Figure 1 a If is not in execution execute it shortcut to CCD icon b If is ON go to point 2 2 Power ON all the SARG sections in the Telescope Control Panel a CCD b Motors c Lamps d Slit viewer 3 Start the SARG motors startup Figure 4 panel and a Start up SARG motors server b Start up CCD server 4 Start the SARG user interface Figure 7 5 Start the system startup in the SARG manager menu more details in SARG The graphical user interface manual 6 When the boot ends stake one bias image to check that everything is working properly 3 How to shut properly down the system Once you have finished working with SARG please shut down the s
8. ystem as follows Close the GUI click on the Sun image marked with the label Arrivederci at the GUI bottom and the GUI program will end 3 1 Stop the servers Once having closed the GUI came back to the Dolores Motors StartUp ShutDown panel Press the Motors Shut Down button and the CCD Server Shut Down button The leds associated to these buttons will switch from ON to OFF while changing theirs color from green to gray Now close the panel itself Click on the cross at the top right of the panel Now you can go to the WLBUILD computer and switch all the SARG sections off from the TCP CCD motors lamps and slit viewer 3 2 Shut down check list Close the GUI shut down the CCD server in the SARG motors panel shut down the SARG motors server in the SARG motors panel Close the SARG motors panel Switch off the CCD Motors Lamps and Slit viewer buttons in the Telescope Control Panel U APUNE
Download Pdf Manuals
Related Search
Related Contents
User manual - Clear all refinements SERVICE MANUAL MUX-A22WV Guia do usuário para Windows Speco Technologies CVC5715DNV surveillance camera M-Series Remote Attendant Control, User Manual Manual do usuário de notebook MANUALE di SICUREZZA e di ISTRUZIONI Para トヨドレン製品総合資料(PDF 48.8MB) AEG F78400VI0P Copyright © All rights reserved.