ISTRUZIONI PER L'USO OPERATING INSTRUCTIONS
Contents
1. ISTRUZIONI PER L USO OPERATING INSTRUCTIONS MODE D EMPLOI BEDIENUNGSANLEITUNG GBRUIKSAANWIJZING BRUGERVEJLEDNING INSTRUCCIONES DE USO INSTRUCOES DE UTILIZAGAO OAHTIEX AEITOYPTIAZ os ae Cod 252 100 10 MOBILE AND FIXED GAS SALAMANDERS C 0051 MOD SG GN 1 1 SGF GN 1 1 GB IE CAT l2H3 INDEX Warnings Compliance with EEC directives for gas appliances Installation diagrams Technical data table Gas salamanders Characteristics of gas Data plate Instructions for qualified installer Appliance installation Legal standards technical regulations and guidelines Smoke discharge for type A appliances Check for gas leaks Maintenance Converting for use with a different type of gas gas salamander Changing spare parts User instructions Lighting the pilot Lighting and turning off main burner Complete shutdown of salamander Maintenance cleaning and care Maintenance Cleaning and care What to do if the appliance is going to be out of use for long periods of time Exploded functional parts table Exploded functional parts table for gas salamanders THIS APPLIANCE HAS BEEN MADE FOR COOKING FOOD AND MUST ONLY BE USED BY PROFESSIONALLY SKILLED PERSONNEL IN THE WAY DESCRIBED IN THIS INSTRUCTION MANUAL 1 WARNINGS Read this handbook through carefully as it provides important information for safe installation use and maintenance Keep this handbook in a safe place for future refere
2. GAS SALAMANDER SG GN 1 1 AND SGF 1 1 The appliance is tested and set for working with gas according to the characteristics table attached near the appliance s gas inlet In order for it to function with a different type of gas proceed as follows The conversion must be carried out by qualified personnel The nozzles for LPG are supplied with the appliance in a nylon bag Changing the burner nozzle fig 1 remove the cover 1 from the cooking top of the cabinet 2 the burner 3 will thus remain completely visible Open the air regulating bush 24 of the burner 3 completely and change the nozzle 27 Put everything back in place place the burner air regulating bush 24 at the distance specified A in the TECHNICAL DATA table according to the type of gas Fig 3 Changing the pilot nozzle 19 remove the panel 1 from the cooking top of the cabinet 2 unscrew the pilot connection pipe and replace the nozzle making sure you insert the nozzle and the pilot connection pipe in the nozzle holder at the same time Check that there are no gas leaks by using a soapy water solution Regulating the minimum flame remove the cock knob 8 use a screwdriver to turn the cock 6 adjustment screw 7 until you get the minimum flame required Make sure that the supply pressures are those given in the instruction handbook and on the data plate Supply pressure it must be as specified on the appliance s data plate and in the in
3. INTENANCE CLEANING AND CARE Always disconnect the appliance from the gas supply before starting on any maintenance work 9 1 MAINTENANCE There is very little maintenance to do thanks to the correct way the appliances have been made However we do advise having the systems checked by qualified personnel at least twice a year Control cocks they should be checked and greased by a gualified technician every 6 12 months 9 2 CLEANING AND CARE To ensure proper operation clean the cooking grill frequently as well as the grill supports and the fat collection tray Clean the stainless steel surfaces with a damp cloth or with soap and water if you use detergents make sure they contain no CHLORATES or ABRASIVES then wash with water and dry thoroughly 9 2 1 What to do if the appliance is going to be out of use for long periods of time First of all disconnect the gas supply clean thoroughly following the instructions incase of failures turn the appliance off and notify the assistance service 10 1 EXPLODED FUNCTIONAL PARTS TABLES Mod SG GN 1 1 Mod SGF GN 1 1 F gt S lt O Se a 18 W St Z Ps5 U or S 19 a CHIUSO PILOTA MAX MIN FERME VEILLEUSE MAXIMUM MINIMUM GESCHLOSSEM ZUNDFLAMME LAAG HOOG CLOSED PILOT DICHT WAAKULAM
4. ck in place Radiant panels 4 remove the cover 1 of the cooking top of the cabinet 2 loosen the panel fastening screws remove and replace the panels by turning them around the burners 3 then put everything back in place N B After any replacement or repair check for proper operation of parts that were replaced and adjust them Check for leaks from the gas pipe fittings with a soapy water solution never use a bare flame USER INSTRUCTIONS 8 1 PILOT IGNITION GAS SALAMANDER Push the knob 8 and turn it counter clockwise round to the pilot position M spark symbol Simultaneously press the piezoeleciric lighter knob and button and the pilot burner will light Keep the knob pressed for 10 to 15 seconds and then let it go Check ignition of the pilot located underneath the cooking top of the cabinet If it hasn t repeat the operation 8 2 TURNING THE MAIN BURNER ON AND OFF From the pilot position 4 turn the knob again counter clockwise round to the maximum position big symbol I he burner lights automatically By the turning the knob again counter clockwise round to the position small symbol the burner will be on minimum To turn the burner off turn the knob clockwise round to the JK position only the pilot burner stays alight 8 3 COMPLETE SHUTDOWN OF SALAMANDER To turn the salamander off completely press the knob in the JK position and turn it clockwise round to the position closed 9 MA
5. nce Only professionally skilled personnel must install the appliance and if required convert it to receive a different type of gas Only call one of the manufacturers authorised technical assistance centres for repairs and demand original spare parts Failure to observe the above could undermine the safety of the appliance 2 COMPLIANCE WITH EEC DIRECTIVES GAS APPLIANCES THIS APPLIANCE HAS OBTAINED THE CE APPROVAL CERTIFICATE AS IT SATISFIES ALL THE TESTS CARRYING OUT IN ACCORDANCE WITH STANDARD ESSENTIAL REQUIREMENTS ANNEX EEC DIRECTIVE 90 396 MD 26 06 1990 4 TECHNICAL DATA TABLE GAS SALAMANDERS TOTAL GAS DIAMETER OF NOZZLES IN o NEGE CONSUMPTION HUNDREDTHS OF A MILLIMETRE MODEL X POWER LPG iu LPG NATURAL GAS G30 G31 o G30 G31 G20 No x kW kg h m3 h 30 mbar 37mbar 20 mbar SG GN 1 1 ETA 0 544 135L 205L BY PASS 115 ADJUSTABLE PILOT 19 27 PRIMARY AIR POSITION A mm 20 15 THESE VALUES ARE APPROXIMATE ALWAYS MAKE SURE THE FLAME IS REGULAR 4 1 GAS CHARACTERISTICS The data relative to power and consumption refer to the following types of gas TYPE OF GAS NET HEAT VALUE PRESSURE SUPPLY NHV mbar mm water G20 natural gas CH4 9 45 kW ms h 20 200 G30 butane C4Hto 12 68 kW kg 30 300 G31 propane C3H8 12 87 kW kg 37 370 G25 G20L DE 8 12 kW m h 20 200 G25 aardgas NL 8 12 kW m h 25 250 When installing the appliances the gas supply pressures must be
6. ppliances see the Technical Data Tables and are not for connecting to a natural discharge duct for combustion products These appliances must discharge through specific extractors or similar devices connected to a properly working flue or discharged directly outside lf this is not possible an air suction device can be used connected directly to the outside with a capacity that must be no less than that required see Table 1 plus the quantity of fresh air that is necessary for the well being of the workers 6 4 CHECKING FOR GAS LEAKS Once installed check there are no gas leaks on pipe joints using a soapy water solution You will know if there are leaks by the foamy bubbles that form Never use open flames to check for leaks When the appliance is ready to use check that there are no gas leaks by checking on the gauge if used for a period of 30 minutes that there is no passage or consumption of gas Z MAINTENANCE There is very little maintenance thanks to the correct way the appliances have been made However we do advise having the systems checked by gualified personnel at least twice a year N B the manufacturer declines all responsibility for direct or indirect damage 7 1 caused by incorrect installation bad maintenance tampering improper use and failure to comply with the accident prevention norms regarding the prevention of fire and safety for gas systems CONVERSION FOR USE WITH A DIFFERENT TYPE OF GAS
7. struction handbook see the Technical Data table Check the supply pressure by inserting a rubber pipe with a water gauge or similar in the pressure tap 10 welded on the gas shaft 9 by removing the screw 11 After it has been checked tighten the screw If the supply pressure is different than that specified find the cause and correct it 7 2 CHANGING SPARE PARTS Safety cock 6 remove the cover 1 from the cooking top of the cabinet 2 loosen the nut 5 for connection to the supply shaft 9 and to the burner supply duct 12 unscrew the thermocouple 16 and the pilot ducting 21 from the cock and replace the cock Thermocouple 16 remove the panel from the cooking top of the cabinet 2 unscrew the thermocouple 16 from the cock 6 and from the pilot support 18 and then change it Ignition plug 20 remove the lid 1 form the cooking top of the cabinet 2 loosen the plug fastening nut front the pilot support 18 Remove the plug and change it Piezoelectric lighter 13 remove the lid 1 from the cooking top of the cabinet 2 remove the plug connecting cable 14 remove the fastening nut of the piezoelectric lighter and make the replacement Pilot burner 18 remove the lid 1 from the cooking top of the cabinet 2 loosen the pilot fastening nut 19 and the thermocouple 16 remove the ignition plug connecting nut remove the pilot securing screws and change the pilot Now put everything ba
8. those given above in order to have maximum burner efficiency Pressures mbar 1 millibar lt 1 mbar lt 10 mm water column millimetres Power 1 kW 860 kcal 3 6 MJ 3412 BTU 6 INSTRUCTIONS FOR THE GUALIFIED INSTALLER 6 1 APPLIANCE INSTALLATION e Remove the appliance from its packaging and position it always under an aspiration hood e Always use rigid galvanised steel or copper pipes for connecting the appliance e Ifthe appliance is wall mounted in contact with flammable material place a layer of heat resistant insulating material between the appliance and the wall or leave a space of 200 mm between the appliance and the wall e The appliance gas system and the characteristics of the room in which the appliance is installed must comply with current laws 6 2 LAWS TECHNICAL REGULATIONS AND GUIDELINES e Standard UNI CIG 8723 Ministerial circular no 68 dated 25 11 69 and variations e Accident prevention laws e Always install a cut off cock between each appliance and the gas pipe e Check that aeration in the room is sufficient when the appliance is working considering that the necessary quantity of air for combustion is 2 m h of air for each kW of installed power 6 3 DISCHARGE OF FUMES FOR TYPE A APPLIANCES The appliances must be installed on premises that are suitable for the discharge of the combustion products and must comply with the installation rules Our appliances are considered type A gas a