Home
PHARUS user manual eng rel 1.3
Contents
1. 2X 02M09653 46 U SHAPE metal plates black colour provided into the unit box for truss Suspension We recommend the use of a safety cable connected to the unit and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail Make sure that the iron cable can bear the weight of the entire unit You may attach the Safety cable as shown in the picture 5 1 Protection against liquids The projector contains electric and electronic components which should under no circumstances come into contact with oil water or any other liquid The proper unit functioning would be compromised should this occur 11 PHARUS 5 2 Movement The projector has a maximum vertical movement of 45 I 1 ibo 2 a 9 es ee aoe Sy Knobs for vertical position adjustment 5 3 Risk of fire Each fixture produces heat and must be installed in a well ventilated place The minimum recommended distance from flammable material is 1 MT Minimum distance from the object being illuminated is 2 MT 5 4 Forced ventilation You will note on inspection that the PHARUS features various air inlets and cooling fans located on both ballast and projector These shoul
2. O Pharus balancing with colour changer A A A x A E A QN gt N e A A 4 ON y N Y PR IS 171 o N PSS gt CK 4 4 y 4 y Y y UL 4 y 7 4 7 A IA M ACA 7 E S AY Q R COLOUR CHANGE CODE 03 TA204 The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY The Lighting
3. 3 Manual Rel 1 3 GB The Lighting Company D T S Illuminazione srl ITALY http www dts lighting it Made in Italy 2 PHARUS Le informazioni contenute in questo documento sono state attentamente redatte e controllate Tuttavia non assunta alcuna responsabilit per eventuali inesattezze Tutti i diritti sono riservati e questo documento non puo essere copiato fotocopiato riprodotto per intero o in parte senza previo consenso scritto della D T S DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche funzionali o di design a ciascun proprio prodotto D T S non assume alcuna responsabilita sull uso o sull applicazione dei prodotti o dei circuiti descritti The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All rights are reserved and this document cannot be copied photocopied or reproduced in part or completely without prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles inexactitudes Tous droits r serv s Ce d
4. MENU ENTER DOWN DISPLAY FUNCTIONS The PHARUS ELECTRONIC BALLAST display panel shows all the available functions Using these functions it is possible to change some of the parameters and add some functions Changing the D T S setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it Carefully follow the instructions below before carrying out any variations or selections NOTE the symbol shows which key has to be pushed to obtain the desired function IS IS gt C MEM MENU DOWN Software version 2 10 s MENU Up Down ENTER Up Down TIMER Visualization of lamp life reset possible and total time unit s working reset not possible BALLAST LIFE TIME HOURS 5 amp IS BALLAST LIFE TIME MINUTES o O gt gt gt LAMP LIFE TIME HOURS 111 On ENTER ES incr i IS E arn Is LAMP LIFE TIME MINUTES MITICI IS ISF LAMP STRIKES IS TORESET IS IF IS ion Owe MENU Up Down ENTER Up Down ENTER Up Down 1 7 NOMINAL LAMP POWER BALLAST MONITOR 8 3 3 Lamp Power up bown LI JL Ta ENTER Up Down LILILILI LAMP VOLTAGE Lamp Voltage Lamp Current nan LAMP RRENT Power supply temperature 057 ENTER UpDown LILILI CU monitor 6907 I POWER SUPPLY TEMP PFC and DC DC side IS Does die Password p Down ENTER Up Down DMX address m 1 474 L Ji 3 POWER SUPPLY TEMP won LOL I E Es COCO DC DC
5. SIDE core com INSERT PASSWORD AddM ES Seon R JUS OLI DEFAULTAS00 DMX address no Function on suo c Pharus 1200 1500 electronic IS On HOW AND CHANGE ballast i Up Down Ad c AL ENTER Up Down DMX ADDRESS 18 PHARUS MENU ENTER LAMP FORCED OFF i s COLE Up Down ES Up Down LAMP IS ON OFF lamp ES Down ENTER LAMP FORCED ON MENU Up Down ES ES Down SOFTWARE Software version SOFTWARE VERSION 13 HIDDEN MENU For technical personnel only To operate this menu Enter in Ballast monitor Mon b select sec n enter the default code 1500 and Press C MEM menu down IF IB B C MEM MENU DOWN IF IS RESET TIME AND ENTER Up Down CLLU IS ISS MEM STRIKE LAMP p ES Down 1101 P 135 RESTORE FACTORY MENU E I ES Dow I ANIL ES ES Down P 135 IS SETTING BALLAST E Mond 057 Down doun ES ES Down Up Down gt PL o ENTER ES Dow ob i 0024 GAY CHANGE PASSWORD Up Down ES Es Down 0024 Eg DI Fout E Ts Es SS ENTER Up Down 1E CHANGE FREQUENCY RS 3 IS r 136 MENU Up Down ENTER Up Down L L Iss Up Down gt 135 5 rs Down SURE i j IS MEM OUTPUT LAMP POWER C IS DOWNLOAD SOFTWARE Lic 41 C 3 UPLOAD SOFTWARE LI E PHARUS 19 14 UNIT BALANCING WITH AND WITHOUT COLOUR CHANGER Pharus balancing without colour changer
6. The ambient temperature should not exceed 40 A hot lamp may explode so always wait for at least 10 minutes prior to attempting to replace the lamp Always wear suitable hand protection when handling the lamp 2 5 Level of protection against the penetration of solid and liquid objects The projector is classified as an ordinary appliance and its protection level against the penetration of solid and liquid objects is IP 20 8 PHARUS 3 MOUNTING THE LAMPS Warning Switch off the unit before replacing the lamp Osram HTI 1500W D7 60 Osram HTI 1200W D7 60 Power 1500W Power 1200W Luminous flux 145 000 Im Luminous flux 110 000 Im Colour temperature 6 0009K Colour temperature 6 000 K Lampbase SFc10 4 Lampbase SFc 10 4 with notch Rated life 750 hours Rated life 750 hours 1 Loose the two screws located on the rear side of the unit photo 1 Photo 1 Photo 2 Photo 3 2 Remove the cover photo2 3 Insert the lamp on the lamp socket and tighten the lamp screws photo 3 The lamp used on PHARUS 1500 is made in quartz glass and should be handled with care Always follow the instructions supplied in the lamp s packaging Never touch the glass directly but use the tissue provided in the lamp s packaging The lamp socket is symmetrical DO NOT USE UNDUE FORCE ON THE GLASS In case of difficulty read again the instructions and repeat the procedure 3 1 Lamp alignment The lamp socket is self centering So there is no nee
7. any flammable surface Minimum distance from flammable materials 1 MT Minimum distance from the closest illuminable surface 2 MT Replace any blown or damaged fuses only with those of identical value Refer to the wiring diagram if there is any doubt Connect the unit to mains power via a thermal magnetic circuit breaker 2 2 Prevention of electric shock High voltage is present inside the unit Unplug the unit prior to performing any function which involves touching the inside of the moving head including lamp replacement The level of technology inherent in the PHARUS requires the assistance of specialised personnel for all servicing Please refer to an authorised DTS service centre good earth connection is essential for proper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 2 3 Protection against ultraviolet radiation Never turn on the lamp if any of the lenses or filters are damaged Their respective shielding functions will only operate efficiently if they are in perfect working order Never look directly the lamp when it is on 2 4 Safety The external surface of the unit at various points may exceed 709C Always wear suitable hand protection when handling the unit Always replace the lamp if any physical damage is evident Never install the fixture in an enclosed area lacking sufficient air flow
8. 251 x 269mm electronic 400 x 251 x 220mm 466 mm Projector Packaging Ballast Packaging Dimensions H Dimensions LxWxH LxWxH 1200 450 500 350 300 310 e HU Weight Weight L 4 23 2 Kg 20 5 Kg electromagnetic 8 5 Kg electronic 6 PHARUS 1 TECHNICAL FEATURES Accessories provided into PHARUS 1500 1200 unit box 1x User manual 1x 0505S021 Osram HTI 1500W D7 60 discharge lamp PHARUS 1500 1x 0505S007 Osram HTI 1200W D7 60 discharge lamp PHARUS 1200 2x 02M09653 46 U SHAPE metal plates black colour for truss suspension 4x 05010319 galvanized black Allen key screws 6x16mm for U SHAPE assembling 4x 0501R212 galvanized washers diam 6x12x 1 6mm for U SHAPE assembling Accessories provided into MAGNETIC ELECTRONIC BALLAST unit box 1x 0520P014 Powercon male cable connector blue colour Accessories on request 0521C034 SINGLE FLIGHT CASE for one unit compartment for accessories professional tripod and colour changer 4 swivel wheels 4 dishes on cover for piling 2 butterfly closures 1 each side 03 TA204 COLOUR CHANGER 03 TA205 GOBO HOLDER 02K00516 EXTRACTABLE IRIS 0521A007 PROFESSIONAL TRIPOD 7 PHARUS 2 IMPORTANT SAFETY INFORMATION 2 1 Fire prevention PHARUS 1500 uses a Osram HTI 1500W D7 60 PHARUS 1200 uses a Osram HTI 1200W D7 60 The use of any other alternative lamp is not recommended and will null and void the fixture s warranty Never locate the fixture on
9. 40V 50 60Hz PHARUS 1500 Cod 03 TP005 120 L Magnetic ballast 110V 50 60Hz PHARUS 1500 EB Cod 03 TPOO5 EB L Electronic ballast 90 260V 50 60Hz PHARUS 1200 Cod 03 TP009 L Magnetic ballast 220 240V 50 60Hz PHARUS 1200 Cod 03 TP009 120 L Magnetic ballast 110V 50 60Hz PHARUS 1200 EB Cod 03 TP009 EB L Electronic ballast 90 260V 50 60Hz Lamp Lamp HTI 1500W D7 60 PHARUS 1500 HTI 1200W D7 60 PHARUS 1200 Base SFc 10 4 with notch 5 PHARUS 1 TECHNICAL FEATURES Optical group New optical group with condenser lens Zoom 7 16 Linear focus Extractable iris diaphragm Mechanical dimmer with black out Colours Colour changer optional 5 interchangeable gel filter holders Automatic switching system between colours Gobos Gobo holder for gobo projections optional Construction Made on aluminium and stainless steel High resistance to heat and mechanical stress Removable cover for easy access to lamp Safety Safety microswitches Power supply 220 240V 50 60Hz electromagnetic ballast version 90V 260V 50 60Hz electronic ballast version Power consumption 1600 VA with built in power factor correction External ballast electromagnetic or electronic Weight 21 2 Kg PHARUS 22 8 Kg PHARUS with colour changer 7 Kg electronic ballast 19 Kg electromagnetic ballast Dimensions LxWxH Projector 996 x 381 x 466mm Projector with colour changer 1108 x 381 x 466mm Ballast electromagnetic 300 x
10. Company ISO 9001 2008 D T S quality system is certified to the ISO 9001 2008 standard D T S products are designed and manufactured at the D T S plants in italy 05171084 D T S Illuminazione s r Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it www dts lighting it
11. an all lenses and the reflector using a soft cotton cloth dampened with a specialist lens cleaning solution 10 2 Fans and air passages The fans and air passages must be cleaned approximately every 6 weeks This periodic cleaning will depend of course on the conditions in which the projector is operating Suitable instruments for performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor If necessary clean the fans and air passages more frequently 11 PERIODIC CONTROLS Lamp The lamp should be replaced if there is any visible damage or deformation due to heat This will help to avoid the danger of the lamp exploding Mechanical parts Periodically check all mechanical parts Periodically check the lubrication of all components particularly the parts subject to high temperatures If necessary lubricate with suitable lubricant available from your D T S Distributor Electrical components Check all electrical components for correct earthing and proper connection of all connectors refastening if necessary Fuse replacement Locate the fuse which protects the lamp and electronics in the balast of the PHARUS Using a multimeter test the condition of the fuse replacing it with one of equivalent type if necessary Attention Disconnect mains power prior to removing the projector housing 17 PHARUS 12 DISPLAY FUNCTIONS DFP Digital Function Panel PHARUS ELECTRONIC BALLAST
12. d under no circumstances be blocked or obstructed whilst the projector is in operation Doing so could cause the fixture to seriously overheat thereby compromising its proper operation 5 5 Ambient temperature The projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 6 MAINS CONNECTION PHARUS with electronic ballast operate at 90 260 VOLT 50 60 Hz PHARUS with electromagnetic ballast operate at 220 240 VOLT 50 60 Hz or 110 V 50 60 HZ Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available For connection purposes ensure that your plug is capable of supporting 8 amps at 220 24 0V Or 16 amps at 110 V Electromagnetic ballast Strict adherence to regulatory norms is strongly recommended 220 240 V 50 60 Hz or 110 V 50 60 Hz Main AC Panel connector 6 1 Protection The use of a thermal magnetic circuit breaker is recommended for each PHARUS A good earth connection is essential for the correct operation of the projector Electronic ballast 90 260V 50 60Hz Main AC Panel connector 12 PHARUS 7 OPENING THE PROJECTOR HOUSING It is possible to inspect the inside of the projector by opening the covers as indicated below ATTENTION REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR S INTERNAL COMPONENTS REAR SIDE 1 Loose the two screws located on the rea
13. d to align the lamp PHARUS 4 VOLTAGE AND FREQUENCY The PHARUS with electromagnetic ballast operates at 220 240 VOLT 50 or 60 Hz available also at 110 VOLT 50 or 60 Hz Please note that Electromagnetic Ballast can not be use in Pharus 1500 EB Electronic ballast On Off switch Main Ac Panel connector Fuse Proiector Fans speed holder regulation connector knob socket The PHARUS with electronic ballast operates at 90 260 VOLT 50 or 60 Hz Please note that Electronic Ballast can not be use with pharus 1500 Electromagnetic ballast On Off switch Main Ac Panel connector Projector connector socket holder 10 PHARUS 5 INSTALLATION PHARUS may be either floor or ceiling mounted For floor mounting installations the unit is provided with a bracket for fixing to floor stand The floor stand from which the unit is fixed should be capable of bearing the weight of the unit For ceiling mounted installations we reccomend the use of appropriate clamps to fix the unit to the mounting surface The supporting structure from which the unit is hung should be capable of bearing the weight of the unit as should any clamps used to hung it Two U SHAPE metal plates included into the unit box allow to hang the PHARUS on the truss by using an additional clamp Clamp not included gt T Bracket for fixing the unit to floor stand
14. ocument ne peut tre copi photocopi ou reproduit dans sa totalit ou partiellement sans le consentement pr alable de D T S D T S se r serve le droit d apporter toutes modifications et am liorations esth tiques fonctionnelles ou de design sans pr avis a chacun de ses produits D T S d cline toute responsabilit sur l utilisation ou sur l application des produits ou des circuits d crits Las informaciones contenidas en este documento han sido cuidadosamenteredactadas y controladas Con todo no se asume ninguna responsabilidad por eventuales inexactitudes Todos los derechos han sido reservados y este documento no puede ser copiado fotocopiado o reproducido total o parcialmente sin previa autorizaci nescrita de D T S D T S se reserva el derecho a aportar sin previo aviso cambios y modificaciones de car cter est tico funcional o de disefio a cada producto suyo D T S no se asume responsabilidad de ning n tipo sobre la utilizaci n o sobre la aplicaci n de los productos o de los circuitos descritos 3 PHARUS INDEX 1 TECHNICAL FEATURES 4 2 IMPORTANT SAFETY INFORMATION 7 2 1 Fire prevention 2 2 Prevention of electric shock 2 3 Protection against ultraviolet radiation 2 4 Safety 2 5 Level of protection against the penetration of solid and liquid objects 3 MOUNTING THE LAMP 8 3 1 Lamp alignment 4 VOLTAGE AND FREQUENCY 9 5 INSTALLATION 10 5 1 Protection against liquids 5 2 Movement 5 3 Risk of fi
15. r side of the unit photo 1 2 Remove the cover photo2 Photo 1 Photo 2 FRONT SIDE 1 Loose the screws located on the bottom front side of the unit photo 1 2 Now it is possible to move the covers for internal inspection photo2 and 3 Photo 1 Photo 2 Photo 3 13 8 IRIS REPLACEMENT ATTENTION REMOVE MAINS POWER PRIOR TO ACCESSING THE PROJECTOR S INTERNAL COMPONENTS 1 Move the dust cover toward the front of the unit photo 1 2 Push the iris security lock photo2 3 Pull up the iris assembly photo 3 Photo 1 Photo 2 Photo 3 14 PHARUS 9 PROJECTOR USE 9 1 Focus and Zoom Focus and zoom adjustment lenses are located on the front side of the unit Place the projector on the object to illuminate loose the fixing lenses knobs adjust the lenses position till the projection is whell focused on the object Thighten the knobs FOCUS ZOOM 15 9 2 Iris and Dimmer Iris and Dimmer are located on the front side of the unit Move the iris from left side to right side to reduce the projected area photo 1 and 2 Move the Dimmer from right side to left side to reduce the light output intensity till blackout photo 3 and 4 Photo 1 Photo 2 FULL FULL OPEN CLOSED Photo 3 Photo 4 PHARUS 1500 DIMMER FULL closed 16 PHARUS 10 PERIODIC CLEANING 10 1 Lenses and reflectors Even a fine layer of dust can reduce the luminous output substantially Regularly cle
16. re 5 4 Forced ventilation 5 5 Ambient temperature 6 MAINS CONNECTION 11 6 1 Protection 7 OPENING THE PROJECTOR HOUSING 12 8 IRIS REPLACEMENT 13 9 PROJECTOR USE 14 9 1 Focus and Zoom 9 2 Iris and Dimmer 10 PERIODIC CLEANING 16 10 1 Lenses and reflector 10 2 Fans and air passages 11 PERIODIC CONTROLS 16 12 DISPLAY FUNCTION 17 13 HIDDEN MENU 18 14 UNIT BALANCING 19 4 PHARUS 1 TECHNICAL FEATURES PHARUS is the latest evolution of the D T S follow spots range PHARUS is a new follow spot ideal for all professional applications theatres concerts television studios fashion displays special events etc PHARUS offers a distinct improvement in projection quality thanks to a new optical group with condenser lens PHARUS is available in two models PHARUS 1500 fitted with a 1500 W discharge lamp and PHARUS 1200 fitted with a 1200 W discharge lamp PHARUS offers also a series of updated functions that ensure effective and creative use New customizable colour system 5 interchangeable gel filter holders Linear iris diaphragm extractable Linear zoom 7 to 16 Linear focus Mechanical dimmer with black out PHARUS is designed to resist all the rigours of continuous use the body is made in aluminium and stainless steel which offer high resistance to heat and mechanical stress PHARUS is complete with external ballast electromagnetic or electronic PHARUS 1500 Cod 03 TP005 L Magnetic ballast 220 2
Download Pdf Manuals
Related Search
Related Contents
A-link NA110HR HQ W7-52700/ N ficha técnica del producto Mode d`emploi du Troc Soun de Seich Janvier 2014 -BON Samsung ProXpress M3825ND Mono laserski Operational manual truck operator Orientações aos Agentes da Administração 2014 Samsung AP-6151 User Manual Copyright © All rights reserved.
Failed to retrieve file