Home
GCR100 - GSM Controlled Relay
Contents
1. Capacita di commutazione Potenza massima commutata Consumo proprio Tecnologia GSM Quad Band 850 900 1800 1900 MHz Antenna integrata Cassetto SIM accessibile dal esterno SIM 1 8 3 3V no USIM Controlli LED rel LED GSM tasto TEST Contenitore policarbonato ABS gsmrelay gmail com
2. SWITCH amp TEST BUTTON Red LED gives the Relay status LED ON gt RELAY ON closed LED OFF gt RELAY OFF open Green LED gives functional information on the GSM network status and operation continuously ON during device power ON very fast blinking about 2 flash s no valid SIM or PIN enabled fast blinking about 1 flash s gt no GSM network coverage searching slow blink about 1 flash 3s gt GSM network OK 1 long flash about 2s when call is received or SMS is received sent After installation local test can be performed by pressing the TEST button This button has two functions short press Relay ON OFF press the button and keep pressing for about 1 s till the red LED goes OFF or ON this switches the relay long press gt Relay ON OFF and test SMS sending to phone number 1 press the button and keep pressed till the red LED changes status relay ON or OFF and the green LED makes a long flash about 2s means that test SMS was send also to the programmed phone number 1 Note for test SMS sending feature the phone numbers must be programmed previously see SMS COMMANDS LIST chapter SMS commands can be send easily by sending a text message to GCR100 by writing one of the strings in the Command column listed below Command Description Response Phn1 393401234567 Setup phone no 1 master Call back Phn2 393401234567 Setup phone no 2 only call switch Call back Phn3 393401234567 Setup phon
3. by call command 3 3 rd number can control GCR100 only by SMS commands GCR100 controls the incoming SMS or call number and accept commands only from the programmed numbers All other calls or SMS with no command content received from other numbers will be ignored and deleted Warning the phone numbers saved in the SIM card will be erased at first power up of GCR100 Relay status is saved If power interruption occurs after powering ON again the relay previous status is recovered see also notification SMS SMS COMMANDS LIST amp NOTIFICATION SMS SIM CARD INSTALLATION To use the GCR100 a valid SIM card is needed Before installation take care check if your SIM card has enough credit and is not expired disable PIN code by using a common cell phone the GCR100 swill not operate if the installed SIM card has PIN code enabled How to disable PIN code read your mobile phone users manual GCR100 is not compatible with USIM e g H3G To install the SIM card 1 unplug GCR100 from the wall socket wait about 15 s 2 using a pen or a similar object push the SIM card holder till the holder is released 3 pull out the SIM holder install the SIM in the holder follow the shape 4 reinstall the SIM holder by pushing back 2 li 3 WALL SOCKET INSTALLATION Simply connect the GCR100 to the wall socket The device is self powered from the socket The 2 LED s provides status of the operation LED s amp
4. is not sent if the switch is performed from phone number 1 TECHNICAL CHARACTERISTICS Power Supply Voltage 85 265VAC 50Hz Switching Capacity max 14A 265VAC Maximum Switching Power max 3200VA Self Power Consumption max 3 5W in Standby max 8 5W during GSM communication SMS call GSM Module Quad Band 850 900 1800 1900 MHz Antenna Internal SIM Slot Externally accessible 1 8 3 3V SIM no USIM Control Relay LED GSM LED TEST button Housing polycarbonate ABS gsmrelay gmail com GCR100 Telecontrollo GSM manuale d uso ITA rev1 120427 GCR100 un dispositivo di telecontrollo via rete GSM estremamente facile da usare in grado di accendere o spegnere a distanza qualsiasi dispositivo alimentato dalla rete da 115 o 230V come cancello caldaia serranda illuminazione irrigazione ecc Il sistema intelligente permette il controllo virtualmente da ovunque senza alcun addebito di costi Questo manuale descrive come installare e usare il dispositivo per telecontrollo GSM GCR100 Prima di qualsiasi operazione leggere attentamente il manuale 3 Tasto COMM TEST Pulsante rilascio SIM Supporto SIM Nota per poter inviare il SMS di test prima bisogna programmare i numeri telefonici vedere il capitolo COMANDI SMS e SMS DI NOTIFICA COLLEGAMENTO DELLO CARICO Prima di collegare il carico verificare che la potenza massima non supera la capacit di commutazione del GCR100 di cca 32
5. 00W Dopo semplicemente collegare la spina dello carico nella presa femmina del GCR100 CONTROLLO A DISTANZA TELECONTROLLO GCR100 pu essere controllato a distanza da qualsiasi telefono cellulare o fisso L accensione spegnimento dello carico pu essere fatta tramite delle chiamate voce oppure comandi SMS La chiamata viene interpretata come un commando chiusa subito senza alcun addebito di costo La condizione per il corretto funzionamento di non aver coperto nascosto i numeri dai quali sono ricevuti i comandi 3 diversi numeri di controllo possono essere impostati 1 numero 1 numero telefonico amministratore da questo numero sono accettati i comandi di chiamata comandi SMS verranno inviati i messaggi SMS di notifica e test 2 numero 2 controlla la commutazione del GCR100 solo con chiamate 3 numero 3 controlla la commutazione del GCR100 solo con comandi SMS Le chiamate ricevute da altri numeri gli SMS con contenuto diverso dai comandi saranno ignorati Attenzione al primo avvio i numeri salvati nella scheda SIM verranno cancellate Ad ogni commutazione lo stato viene salvato in modo che a una interruzione temporanea di alimentazione lo stato precedente viene ripristinato vedi anche SMS di notifica COMANDI SMS e SMS DI NOTIFICA INSTALLARE IL SIM CARD Per usare il GCR100 serve una scheda SIM attiva Prima d installare la scheda SIM bisogna effettuare i seguenti operazioni veri
6. GCR100 GSM Controlled Relay User Manual ENG rev1 120427 GCR100 is an easy to use remote control switch suitable to remote control trough GSM network so virtually from everywhere a 115 or 230V load such as garage door alarm system lighting boiler surveillance system etc The intelligent system gives the possibility perform the control without any cost charge This manual describes how to install and use the GCR100 Please read carefully this manual before installation and use SIM release button SWITCH amp TEST button CONNECT THE LOAD Before connecting the load check if the consumed power is below the GCR100 switching capability about 3200W After simply connect the load you need to control remotely to the female socket of the GCR100 REMOTE CONTROL Remote control can be performed by any active cell phone Relay can be switched ON or OFF remotely by an SMS command see SMS COMANDS LIST chapter or by a call Call will be hanged up without charging any cost The only condition is to program previously the phone number s of the phones from which you want to control GCR100 The cell phone numbers must be not hidden Three different phone numbers can be programmed f 1 st number this is used as master number from this GCR100 can be fully controlled by SMS commands and call commands and the notification and test SMS messages will be send to this number 2 2 nd number can control GCR100 only
7. a o PIN abilitato lampeggio veloce cca 1 lampeggi s gt mancanza rete GSM ricerca rete lampeggio lento cca 1 lampeggi 3s gt segnale GSM OK 1 lampeggio lungo cca 2s quando il GCR100 riceve chiamate o SMS oppure invia SMS Dopo l installazione possibile verificare il funzionamento tramite il tasto TEST Il tasto dispone di 2 funzioni pressione corta gt commutazione rel premere il tasto per cca 1s fino quando il LED rosso cambia stato con questa operazione possibile chiudere aprire il rel per verificare la corretta commutazione pressione lunga gt commutazione rel e invio SMS di test premere il tasto per cca 3s fino quando il LED rosso cambia stato e il LED verde fa un lampeggio lungo di cca 2s Questa operazione invier un SMS di test al Phn1 numero telefonico 1 La programmazione del GCR100 avviene tramite alcuni comandi SMS Oltre possibile abilitare anche dei messaggi SMS di notifica Comando Descrizione Risposta Phn1 393401234567 Imposta numero 1 amministratore Richiamata Phn2 393401234567 Imposta numero 2 solo chiamata Richiamata Phn3 393401234567 Imposta numero 3 solo SMS Richiamata Rphn Leggi numeri impostati SMS elenco numeri tel Notif en dis Abilita disabilita notifiche Richiamata Notif Leggi impostazioni notifiche SMS impostazioni notifiche Relon Commuta rel in chiuso Richiamata Reloff Co muta rel in aperto Richiamata Rstat Leggi stato rel SMS stato attuale re
8. e no 3 only SMS switch Call back Rphn Read programmed phone numbers SMS programmed numbers list Notif en dis Notification SMS enable disable Call back Notif Read notification s enable setup SMS notifications setup Relon Switch relay ON Call back Reloff Switch relay OFF Call back Rstat Read relay actual status SMS Relay actual status Power ON notification GSMRelay powered ON Relay is ON Switch notification GSMRelay was sitched ON Test SMS by pressing the key GMSRelay Test SMS Notes setup commands are not accepted from phone numbers 2 and 3 from phone no 3 are accepted only the Relon Reloff and Rstat commands phone numbers in the Phn commands are only example phone numbers within Phn commands must be always in international format lt gt lt country code gt lt operator code gt lt phone number gt call back response short call OK long call error e g bad command for notification setup Notif command first field regards the Power ON notification second field is for any Relay Status change in Notif command to enable en must be written to disable dis must be written commands are not case sensitive Relon RELON relon If power ON notification is enabled each time when the GCR100 is powered ON will send an SMS message to phone no 1 containing also the relay actual status Switch notification if enabled is sent even in case of switching the relay by button The switch notification
9. ficare se il SIM dispone di abbastanza credito e non scaduto usando un comune telefono cellulare disabilitare il codice PIN sulla scheda Per sapere come effettuare questa operazione consultare il manuale d uso del vostro cellulare GCR100 non funziona con schede SIM con codice PIN abilitato GCR100 non compatibile con schede USIM es H3G Per installare la scheda SIM 1 rimuovere il GCR100 dalla presa di corrente ed aspettare circa 15 s 2 con una penna o un oggetto simile premere il pulsante vicino al cassettino della scheda SIM fino quando il supporto fuoriesce 3 estrarre il supporto SIM posizionare la scheda nel supporto 4 inserire il supporto e premere fino in fondo non forzare 2 gt 3 as INSTALLAZIONE NELLA PRESA DI CORRENTE Semplicemente inserire GCR100 nella presa di corrente se serve usare un adattatore per spina SHUKO Il dispositivo autoalimentato dalla presa i 2 LED informano l utilizzatore sullo stato del dispositivo Se serve un adattatore tener conto dalla potenza assorbita dal carico che verr commutato preferibilmente usare una presa da 16A INDICATORI LED e TASTO COMMUTAZIONE TEST Il LED rosso segna lo stato del rel come segue LED ACCESO gt RELE CHIUSO LED SPENTO gt RELE APERTO Il LED verde fornisce informazioni sullo stato della rete GSM acceso continuo durante l avvio del dispositivo lampeggio molto veloce cca 2 lampeggi s gt scheda SIM non valid
10. l gt Notifica di accensione GSMRelay powered ON Relay is ON Notifica di commutazione GSMRelay was sitched ON SMS di test premendo il tasto GMSRelay Test SMS Note i comandi SMS d impostazioni non sono accettati dai numeri 2 e 3 dal numero 3 sono accettai solo il comandi Relon Reloffe Rstat i numeri di telefono nei comandi Phn sono solo esempi i numeri di telefono nei comandi Phn devono essere inseriti in formato internazionale lt gt lt codice paese gt lt codice operatore gt lt numero telefonico gt riposte con richiamata squillo corto OK squillo lungo errore es commando errato nel commando d impostazione per le notifiche Notif il primo campo riguarda la notifica ad ogni accensione il secondo campo riguarda la notifica ad ogni commutazione nel comando Notif per abilitare scrivere en per disabilitare scrivere dis i comandi non sono case sensitive Relon RELON relon Se la notifica di accensione abilitata ad ogni accensione GCR100 invia un SMS di avviso al numero 1 informando anche con lo stato del rel dopo la riaccensione La notifica di commutazione viene inviata anche se lo stato viene cambiato dal tasto TEST La notifica di commutazione invece non viene spedita se il controllo viene fatto dal numero telefonico 1 CARACTERISTICHE TECNICE 85 265VAC 50Hz mass 14A 265VAC mass 3200VA max 3 5W in standby max 8 5W durante la comunicazione in rete GSM Alimentazione
Download Pdf Manuals
Related Search
Related Contents
Polaroid PhotoMAX PDC 2070 User's Manual Harbor Freight Tools 1102 User's Manual 自転車安全のしおり_1110.indd Speedport W 920V USER MANUAL - BZB Express 取扱説明書 - トーヨーキッチン User manual manuel de l'utilisateur guía del usuario Printer Installation Guide Slides 圧力分布からサノ 買管理を Copyright © All rights reserved.