Home

LV8D : Reference and Installation Manual

image

Contents

1. AAAA vvvv C1 C2 Mode Wiring Diagram ON OFF In this configuration C1 uses Multibus power C2 uses an external power supply e Maximum combined current for outputs 1 to 4 1A according to available Multibus power e Maximum combined current for outputs 5 to 8 2A ci ci G Q 12Vde fe e Multibus Power ON 0 24Vac dc External Power D O 12Vdc Relay C2 OFF esses eese 0 c1123 4 C25 6 7 8 GND E BUS RX gL il LvsD Imperial Multibus BUS INPUT RED BLK GAN YEL IN1_IN2 Seeee AAAA vvvv 24Vdc Power Supply O 24Vdc Relay OFF ON In this configuration all outputs use the C1 power supply e Maximum combined current for all 8 outputs 2A CEEI _ 0 24Vac de OFF External Power C2 C2 ON C z 24Vdc Relay 24Vdc Power Supply C1 OFF C20N e0999 E Ur eese C25 6 7 8 GND Ea Bus RX TX i jiji LvsD Imperial Multibus Ji BUS INPUT RED BLK GAN YEL IN1_IN2 eeeee AA
2. Modules display area To view the Modules display area click the Modules toggle button Alternatively you may wish to add a module to canes Pang BabyWare before the module is physically connected to the system Click m gt IMPERIAL the Add Item button File View Tools Event Communication Help es Accounts E Save ep Print amp Trash cong Q Add item wosses EH Switch Areas zor Category Serial Q Volt a Macros 4 Relay Controller Properties File Modules 5 items 2 To program a module that has already appears in the system double me ko ame Pere click the module s icon The Relay Controller Properties window opens wis DEED 4 i Be 216d 3 From the Type drop down list select Sprinkler Light or Custom relay ES 2020 Name Type mode YUBAD M output 1 4 Label the outputs and set required activation deactivation delays es 1ita Output 2 Custom Related Topics Ne REDNO OON te If you have trouble locating the module in BabyWare you can use the Module Locate Feature see Bi directional Locate Feature Patents One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 and RE39406 and other pending patents may apply Canadian and international patents may also apply Trademarks Paradox Imperial MAMA BabyWare the M logo and the triangle logo are trademarks or registe
3. AA vvvvV O 24Vdc Relay OFF OFF In this configuration both C1 and C2 terminals use external power supplies e Maximum combined current for outputs 1 to 4 2A e Maximum combined current for outputs 5 to 8 2A ci ci 0 24Vac dc OFF External Power 0 24Vac dc External Power C2 2 C 24Vdc Relay E 24Vdc Power Supply C1 OFF e O09909 c1123 4 E Bus RX TX o B OL OC O Imperial Multibus BUS INPUT RED BLK GRN YEL IN1_IN2 eeeee AMAA e vvvv O a 24Vac Power Supply 24Vac Relay LED Feedback BUS RX TX _ STATUS eee besse Green Green OK communication in Ro flash flash progress Se ee Red Com fail short on GRN si Ai ol E Green Com fail too many BC 0 a i on modules GC GBE OUTPUTS 1 to 8 Green Green Com fail GRN and YEL C Oo Press to activate deactivate on on lines reversed lvaD __ _ Green On Output activated Off Output deactivated Red Bus power too low nnn flash Green Green Module locate mode Re a flash flash 600090909 Blue Firmware upgrade in flash progress Bi directional Locate Feature Pressi
4. LV8D 8 Output Low Voltage Relay Module Description Driven by the V32 main controller s 4 wire communication bus Multibus the LV8D has 8 solid state relay outputs that can drive up to 250mA each 0 to 24V AC DC Each set of 4 relays has a jumper selectable power source that can be the 12Vdc Multibus power or an external 0 24Vac dc power source These outputs can be used to control external relays or to power low voltage devices such as sprinkler valves low voltage lights door strikes or devices equipped with a 24Vdc external trigger e g air conditioners thermostats garage doors When using an external 24Vac dc power supply the LV8D outputs can be used to drive 24Vac dc relays With its DIN rail design the module saves space and makes installation and wiring significantly faster and easier Overview AX P E R l AL En A Installation Wiring Programming 1 Programming 2 Testing Total Time Features 8 solid state relay outputs 0 24V AC DC 250mA each e Selectable relay power internal 12V external Remote firmware upgradeability via bus e DIN rail design with manual control for outputs on board status display and removable terminals e Programming via BabyWare software e 4 wire connection to the Imperial Multibus with up to 900m 3000ft distance e Bi directional Locate feature from module to software and vice versa 1 Manual output control and stat
5. es low voltage lights door strikes Certain devices e g air conditioners thermostats garage doors may be equipped with an external trigger Triggers requiring 12Vdc and less than 100mA can be driven directly from the LV8D output using 12Vdc Multibus power For all other requirements e g current higher than 100mA or different voltage use an external power supply External Power The LV8D outputs can be used to drive 24Vac dc relays when connected to an external 24Vac dc power supply WARNING Do not supply external power to C1 if C1 jumper is on Do not supply external power to C2 if C1 jumper and C2 jumper are on WARNING It is highly recommended to power the module using an external source e g PS100 or PS27D and NOT from the Multibus to avoid flickering of the output in case of a loss of bus power Flickering may cause damage to electrical appliances connected to the outputs C1 C2 Mode Wiring Diagram ON ON In this configuration all outputs use Multibus power e Maximum combined O O current for all 8 outputs 12VdciRelay ON ooed Geoos 12Vdc Relay 1A according to available Multibus criza s czs e 7 8 cw power E ee oo oc of 2 1G 17 ON CON os OC NC OC RX mA ol xi C CjT ds ED BLK GAN vaj 1N1_IN2 00009 Imperial Multibus 4
6. ng and holding the LOC button for 3 seconds will initiate the Module Locate feature When a Module Locate is initiated the module s representation in the BabyWare software will flash and the module s BUS RX and TX LEDs will flash to indicate that it is in locate mode A module locate can also be initiated from the BabyWare software From BabyWare right click the module s representation and select Locate Physical The module s BUS RX and TX LEDs will flash We highly recommend that after pressing locate and identifying the module open the programming page and assign the proper physical location label and the outputs labels and locations After complete connection use the space provided on the module to indicate the outputs description Remote Firmware Upgrade The LV8D is firmware upgradeable remotely via the V32 controller s Multibus at 57 6Kbps Using BabyWare connect to the V32 account using any of the connection methods direct connect IP static or IP DNS Right click the desired module and select Upgrade A firmware upgrade for a single module or group of modules will take usually less than 10 minutes which keeps system downtime to a minimum Programming an LV8D Module Figure 16 LV8D Programming For more information on programming modules refer to BabyWare in the Imperial System Guide 1 When BabyWare is communicating with the V32 controller and a LV8D module is connected to the Multibus it automatically appears in the
7. red trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries Certification For the latest information on products approvals such as UL and CE please visit www paradox com Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www paradox com terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions 2009 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice P A R ADO X SECURITY SYSTEMS PARADOX COM Printed in Canada 04 2009 ILV8 E101
8. us buttons 2 Module Locate feature activation see Bi directional Locate Feature 3 Multibus status LEDs 4 Product serial number For LED status see LED Feedback Low voltage relay outputs 4 wire Multibus connection Trigger activation input future use Power configuration jumpers see Wiring For items A to E refer to Wiring Related Topics Specifications Installation Wiring refer to the Imperial System Guide Operating voltage Typically 12Vdc gt DIN Rail Enclosures Relay voltage range 0 24Vac dc e System Diagrams and Wiring Tips e Wire Gauge Selection Relay maximum 500mMA continuous current Features per output Remote Firmware Upgrade Current min 30mA e Bi directional Locate Feature Consumption max 120mA oh ae Dimensions DIN9 11cm X 10cm X 6cm 4 2 X 4 X 2 5 Applications refer to the Imperial System Guide i e Light Control Operating 10 C to 50 C Sprinklers Temperature 14 F to 122 F e Macros BabyWare refer to the Imperial System Guide e BabyWare Wiring To use the LV8D s internal 12Vdc power source connect the C1 relays 1 4 and or C2 relays 5 8 jumpers To use external power disconnect the jumpers and connect the external power source as shown in the wiring diagrams Internal Power The LV8D s 12Vdc Multibus supply can be used to control external relays or to power low voltage devices e g sprinkler valv

Download Pdf Manuals

image

Related Search

Related Contents

MC68030 Second-Generation 32-Bit .. Enhanced Microprocessor  Samsung 418 litros Refrigerador T F RT50WNPP1/GSL Manual de Usuario  RET 3275 Elektrický kultivátor  Arrow CHD1015 Installation Guide  Segurança - Amazon Web Services  RDM PARAMETER IDS 1. SL PAR 150 ZOOM RGBW LED  Mustek UPS PowerMust 2000 USB P    Montageanleitung-Oel-Brennwertkessel-Wolf-TOB    