Home
User Guide Model 480826
Contents
1. User Guide EXTECH INSTRUMENTS A FLIR COMPANY Three Axis Electromagnetic Field EMF Meter Model 480826 Triple Axis EMF TESTER EXTECH 480826 Introduction Congratulations on your purchase of Extech s Model 480826 Electromagnetic Field EMF Meter The Model 480826 is a battery powered meter that measures and displays EMF in Gauss and Tesla units with a frequency bandwidth of 30 to 300Hz The 3 axis sensor allows for three component xyz measurement coverage The Model 480826 is specifically designed to determine the magnitude of electromagnetic fields generated by power lines computers electric appliances televisions and many other similar devices This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Meter Operation Press the POWER button to turn the meter ON Press the UNIT button to select either uTesla or mGauss units 3 Ifthe approximate range of the measurement is known select the suitable meter range using the RANGE button For unknown measurements start with the highest range and work down through the ranges until the optimum range is reached 4 Hold the probe by its handle and move it slowly toward the object under test If the LCD display is completely blank or if the low battery symbol appears on the LCD check the 9V battery Notice that the field intensity reading increases as you move closer to a field Use the XYZ button to read the EMF meas
2. con appears on the left corner of the LCD the 9V battery has fallen to a critically low voltage level and should be replaced as soon as possible The battery compartment cover is located at the bottom rear of the meter Remove the Phillips head screw that secures the battery compartment and slide off the battery compartment cover Replace the battery and secure the compartment cover before use You as the end user are legally bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Copyright 2011 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form www extech com 4 480826 EU EN V3 1 8 11
3. tion Dimensions Sensor Cable Length Weight Battery compartment access screw Battery compartment cover Approx 0 4 seconds Accuracy Triple Axis EMF TESTER EXTECH 480826 3 1 2 digit 2000 count LCD 20u Tesla 0 01 and 200mGauss 0 1 attit sS 200uTesla 0 1 and 2000mGauss 1 2000uTesla 1 and 20 000mGauss 10 i NOTE 1 uTesla 10 mGauss 4 FS 3 digits for 20uTesla and 200mGauss ranges 10 FS 5 digits 2000uTesla amp 20 000mGauss ranges 30 to 300Hz Over range indication 1 is displayed Temperature 0 to 50 C 32 to 122 F RH 90 max from 0 to 35 C 32 to 95 F 80 max from 35 to 50 C 95 to 122 F 9V Battery Approx 2 7mA DC Meter 195 x 68 x 30mm 7 6 x 2 6 x 1 2 Probe 70 x 58 x 220mm 2 8 x 2 3 x 8 7 1m 3 ft approx 460g 16 2 oz including probe and battery 3 480826 EU EN V3 1 8 11 EMF Exposure The effect of EMF exposure is a modern day concern At the time of this writing to the best of our knowledge no standards or recommendations exist regarding limits of EMF exposure Exposure limits of 1 to 3mG have been suggested by several international bodies Until evidence suggests that there is not a health risk associated with EMF exposure common sense would dictate that a practice of minimal exposure be exercised Battery Replacement When the low battery i
4. urement in the X Y or Z axis If the meter s display indicates a 1 on the left side of the LCD an overload condition exists This indicates that the measured radiation is higher than the capability of the currently selected range Find the appropriate range using the RANGE button as described above Measurement Notes Due to environmental electromagnetic interference the display may show small EMF values before testing This is normal and due to the high sensitivity of the meter Once a signal is detected by the sensor the meter will display accurately If the object under test is turned off in the middle of testing the meter reading should fall close to zero unless a field from another source is detected Data Hold feature To freeze a displayed reading press the HOLD button The DH display icon will switch on To unlock the display and return to normal operation press the HOLD button again The DH indicator will switch off 2 480826 EU EN V3 1 8 11 Mete r Description 1 oe IX de eS N N o 13 Sensor plug shown inserted in meter s sensor jack LCD Display XYZ axis select button Manual Range button Power button Data Hold button Unit select button Sensor Sensor grip handle Tripod mount Pull out tilt stand Specifications Display Measurement rate Ranges and resolution stated for 50 60Hz Frequency bandwidth Operating Temperature Humidity Power source Power consump
Download Pdf Manuals
Related Search
Related Contents
Samsung SP-P400B Priručnik za korisnike Peerless MIS660 mounting kit QIG_NETIO4_4ALL installatie handleiding – manuel d'installation Kenmore 5.4 cu. ft. Electric Range w/ Convection Oven - White Owner's Manual 2014-Graines de Paix-Livres en vente M32 QS - Cryogenic Control Systems, Inc. Sin título-1 Ecole du dimanche virtuelle - the Anglican Church of Canada Nortel Networks Water System BCM 1000 User's Manual Copyright © All rights reserved.
Failed to retrieve file