SmartSite® needle-free valve user's guide

image

Contents

1. e Replace every 72 hours or 100 activations whichever occurs first For infusions flushed according to professional of blood blood products or lipid emulsions replace every 24 hours standards of practice and facility e The Centers for Disease Control CDC Infusion Nurses Society and other protocol in order to maintain organizations publish guidelines useful in developing facility protocols and atency and prevent the mixin policies Refer to hospital policies p y p g of incompatible medications e For Power Injector Use use only models that are labeled for Power Injector Use In addition needle free valve must be secured to other luer lock devices also pressure rated for power injector use e Models labeled for power injector use may be used with low pressure power injectors up to 325 psi and maximum flow rates up to 10 mL second e For full device instructions refer to the set Directions for Use Valve not activated As per Standard ISO 1055 5 1997 Valve activated As per NCQ 005 500mL fluid bag at 30 inch head height For more information visit CareFusion com 2010 CareFusion Corporation or one of its subsidiaries All rights reserved SmartSite is a registered trademark of CareFusion Corporation or one of its subsidiaries IV1372 0210 2500 CareFusion San Diego CA carefusion com
2. SmartSite needle free valve user s guide Instructions The SmartSite needle free valve is designed to permit injection and aspiration of fluids without the use of needles Prepare SmartSite needle free valve Prior to every access always swab the top of Flat surface the SmartSite valve with a sterile 70 isopropyl easy to swab alcohol wipe 1 2 seconds and allow to dry approximately 30 seconds For multiple syringes swab prior to each syringe access Attach luer Insert the syringe tip into the valve If syringe has va a male luer lock collar turn syringe clockwise Male to secure the connection If syringe has a slip luer luer Insert and rotate 1 4 turn to secure the connection Inject or aspirate fluid Do not leave slip luer syringes unattended SmartSite valve Apply clamp In accordance with INS flushing standards Straight apply clamp before disconnecting syringe through to help prevent any reflux in the fluid path catheter lumen equal to yA an 18g needle Disconnect luer Securely hold SmartSite valve while disconnecting luer Remove the luer trom the valve by turning counterclockwise closed activated SmartSite valve fluid path Key specifications Priming volume Valve 0 11mL CY Site 0 07 mL Note professional standards Residual volume valve 0 08mL Y site 0 04 mL of practice require Fl 4 L hr 8100 mL hr ow rate 500 mL hr menr Vascular access devices should be

Download Pdf Manuals

image

Related Search

Related Contents

Forerunner 410  GREE MULTI24HP302 Use and Care Manual  Moving ahead.  Mode d`emploi - Comment interroger la base de - CClin Sud-Est  Manual CoolServe Bedienungsanleitung CoolServe    SUNSHIELD 312 Installation Guide  Acesso PE 3.1 – Configurador  User Manual - Quevo Audio  Ultron HeadSet UHS-50  

Copyright © All rights reserved.
Failed to retrieve file