Home

User manual

image

Contents

1. delay parameter is determined delay from midnight This avoids unique devices to send pulse data to server at the same time Range is 0 1000 minutes With parameter value O the data is sent at midnight 00 00 Server path parameter is determined path in server where data is saved Example command where device identifier is 101 server address is services ionsign fi server port is 80 APN is internet input count 12 transmission delay is 1 minute and server path is neutrondata SETTINGS 101 services ionsign fi 80 internet 12 1 neutrondata INTERVAL lt ime gt With this command the device is set to send pulse data to server with defined interval Server is defined with settings command Time parameter is determined time which triggers the data sending to server Range is 0 or 60 65535 seconds With parameter value 0 the data sending by interval is stopped SENDNOW With this command the device sends incomplete pulse data to the server immediately This command has no parameters FACTORY With this command the device resets all its settings and pulse data This command has no parameters Copyright 2013 ionSign www ionsign fi v1 2 User manual 1onsicn 5 9 2013 Neutron12 3G 4 Neutron12 3G specifications e Inputs 12 pulse inputs for open collector or relay outputs of meters Open collector or relay output sourcing voltage 12 VDC maximum sourcing current 5mA Operating voltage 11 13 VDC Current consumption 70
2. mA peak 250 mA Real time clock 4 days backup Size WxHxD 105 x 90 x 52 mm 6 module wide DIN rail enclosure Protection class IP20 Operating temperature 25 C 455 C RH 5 95 non condensing Data storage capacity 30 days for each hour for each input channels Data communication Integrated 3G GSM GPRS module Conforming the following directives and standards R amp TTE Directive 1999 5 EC Radio Equipment amp Telecommunications terminal Equipments Low Voltage Directive 73 23 EEC and product safety Directive 89 336 EEC for conformity for EMC GSM Radio Spectrum Standard EN 301 511 and 3GPP 51 010 1 EMC Electromagnetic Compatibility Standards EN 301 489 1 and EN 301 489 7 LVD Low Voltage Directive Standards EN 60 950 e Antenna External SMA connector 5 Warranty lonSign Oy agrees the warranty of two 2 years for Neutron devices Warranty Starts from the day when the customer has received the device and it concerns material and production defects Warranty is not agreed for devices which are used or wired incorrectly It is not also agreed for situations where defect is related to 3rd party actions Things like this can be service changes by mobile network operator or changes in mobile network itself For devices which are broken during warranty time ionSign Oy delivers a new device for free Alternatively device can be corrected Broken device should be returned to supplier if required Th
3. User manual IOnNSIGN 5 9 2013 Neutron12 3G NEUTRON12 3G 1 General Neutron12 3G is a general purpose pulse counter designed for collecting and reporting pulses from different kind of energy and consumption meters Pulses are collected on an hourly basis and sent to server once per day 2 Introduction The device will be introduced as follows 1 Disable PIN query from the SIM card for example with cell phone 2 Open enclosure and insert the SIM card to the device 3 Connect power supply measuring device or devices and GSM antenna to the device as seen in picture 2 4 Set power on which PWR LED indicates 5 Within 15 seconds the device starts to search GSM network This can be seen in 2G 3G LED as two fast red blinks in interval With one red blink device indicates 2G network and one green blink 3G network Signal LED turns to solid green when signal is good enough for transmission If Signal LED is not on or it s blinking try to find a better place for antenna Device measures GSM signal for five minutes If a good place for antenna is not found in this time power off the device and set powers back on After this procedure the device starts to search network and measure GSM signal again 6 Send SETTINGS command to the device After that the device starts to operate Received command and connection to server is indicated by solid orange Init LED If Init LED is blinking the command is received but connection to server
4. e cost of delivery is paid by supplier ionSign Oy is not responsible for indirect or implicit damage or possible work or travel expenses related to broken device For warranty issues please contact to ionSign Oy by e mail ionsign ionsign fi or by tel 358 0 2 822 0097 Copyright 2013 ionSign www ionsign fi v1 2 User manual 5 9 2013 IONSIGN Neutron12 3G Antenna Neutroni 2 3G Meter Picture 2 Neutron 12 3G circuit diagram For example JAMAK 2x 2 1 x0 5mm2 instrumentation cable can be used between metering device and Neutron device The open collector or relay output of single meter is connected to Neutron device as shown above Copyright 2013 ionSign www ionsign fi v1 2
5. is not established 7 The device blinks PWR LED when it receives pulses from measuring device or devices Every other turns the LED on and every other off femeo 21 22 23 24 25 26 GSM Ant E a o q7 SEPP LSP N S ao E Oo ae 3G Neutron12 3G Signal Init PWR Se SFE SL SS SOS S I y y e SO 12 13 14 15 16 17 18 Picture 1 Device front panel Copyright 2013 ionSign www ionsign fi v1 2 User manual 1OnSIGN 5 9 2013 Neutron12 3G 3 Commands The device is controlled with text message commands shown below The device does not send any reply messages Commands and parameters are separated by one space character SETTINGS lt Device identifier gt _ lt Server address gt _ lt Server port gt _ lt APN gt _ lt nput count gt _ lt Transmission delay gt _ lt Server path gt With this command all required settings are given and pulse data counting is started Device identifier parameter is determined unique ID for each device Range is 1 32765 Server address parameter is determined IP address of the http server Alternatively a domain name server name can be used Maximum length is 30 characters Server port parameter is determined port number where server application waits for transmissions APN parameter is determined APN Access Point Name of GPRS 3G connection Maximum length is 19 characters Input count parameter is determined the number of connected meters in device Range is 1 12 Transmission

Download Pdf Manuals

image

Related Search

Related Contents

    Installation Instructions Instructions d`Installation Instrucciones de  Service And Repair Manual For Small Frame GN  Samsung GT-C3510L manual do usuário(Vivo)  Scarica il manuale d`uso  Accidents de la vie courante  Samsung HT-TZ318H User Manual  Astro Cremona  Tripp Lite Full-Motion Wall-Mount for 17" to 42" Flat-Screen Displays  