Contents
1. 737 4 EA ua LA i l gt AA A DOA ACO A A eg eg a NZ NAN Z id bM 4 Image 1 Recommended sauna room ventilation 1 Sauna room 3 Electric sauna heater 5 Exhaust flue or channel 2 Washroom 4 Exhaust valve 6 Door to the sauna room 7 A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing Inlet vent can be positioned in the A zone Make sure the incoming fresh air will not interfere with i e cool down the sauna heater s thermostat near the ceiling The B zone serves as the incoming air zone if the sauna room isn t fitted with forced ventilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LO CATED IN THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna heater may emit some odour If you detect any odour while the sauna heater warms up disconnect the sauna heater briefly and air the room Then you can turn the sauna heater on again The sauna heater is turned on from the control panel that has controls for the heating temperature and time The heating of a sauna should be started roughly an hour before you plan to take a sauna bath so that the stones have time to heat up proper
2. Produkten returneras till atervinningscentralen utan bastusten och eventuell taljstensmantel Vanligen kontakta de kommunala myndigheterna for att ta reda pa var du hittar narmaste atervinningsplats Hinweise zum Umweltschutz Dieses Produkt darf am Ende seiner Lebens Dauer nicht uber den normalen Haushaltsabfall Entsorgt werden sondern muss an einem Sammelpunkt fur das Recycling von elektrischen und elektronischen Geraten abgegeben werden Das Symbol auf dem produkt der Gebrauchsanleitung oder der Verpackung weist darauf hin Die Werkstoffe sind gem ihrer Kennzeichnung wiederverwertbar Mit der Wiederverwendung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten leisten Sie einen wichtigen Beitrag zum Schutze unserer Umwelt Dieses Produkt soll ohne Steine und Specksteinmantel an dem Sammelpunkt f r Recycling zur ckgebracht werden Bitte erfragen Sie bei der Gemeindeverwaltung die zustandige Entsorgungsstelle
3. T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles When installing the connection box to zones 2 or 3 refer to the instructions and regulations of the local energy supplier 10 Installation and User Manual FONDA 11 3 Principle image when T1 is used as control panel Connector strip Limiter 11 Valk Vit White Weiss Heater 12 Musta Svart Black Schwarz i 13 Vihre Gr n Green Gr n erer 14 Kelt Gul Yellow Gelb 15 Harm Gra Grey Grau J S d EN 16 Rosa Ljusr d Pink Rose pis E 17 Sin Bla Blue Blau EET 18 Pun R d Red Rot DOUOCOOCH 11 12 13 14 15 16 17 18 19 20 21 Control panel T1 Sensor OLET 28 Control panel T1 NOTE See the sauna heater instruction for correct installation location gee Silicone 4 x 0 25 LiYCY 8 x 0 25 Sauna heater Input 230V 240V 1N 2 230V 3 400V 415V 3N Image 4 Principle installation Installation and User Manual FONDA 3 8 Wiring diagram Teho Effekt L mp vastukset V rmeelement Tennid Heating elements Input Potencia Heizeelement Resistores T rmicos El ments chauffants vidis Dura Elementy grzewcze V imsus Wejscie yg TOHbI Puissance BnacTb 230 V SEPC SEPC SEPC TAKN 230V 240V 1N 2 kW 2200W 2200W 2667W Alelalelelo 4 4 L eren 6 6 123 f tf ft 8 0 4 4 kW 400V 415V 2N EY LLLI f ttf N 1 2 amp 6 6 8 0 kW 230V 240V 1N 2 6 t
4. are upwards The bottom wall mounts can be turned so that the holes are downward as no locking screws will be screwed into them 2 Then install the sauna heater so that the upper supporting iron is touching the groove in the wall mount and move the heater backwards as far as it goes towards the wall It might be necessary to slightly loosen the wall mount s screws so that it is easier to locate the supporting iron on the wall brackets 3 If you loosened the wall mounts screws in the previous point you must tighten them again Then place the locking screws in the holes in the upper wall mounts and fully tighten them Ensure that the heater has been locked in place by trying to move it forwards and backwards Installation and User Manual FONDA 8 3 3 Safety distances ten mm A A mm 40 Se section 3 4 Absolute measure min 1900 Image 2 Safety clearances Adequate amount Power Saunaroom Safety clearances min q of stones E E L On the sides In front Till tak To the ceiling Hoch D F Da s Approx kg mm 20 8 12 1900 50 50 1135 100 1900 50 50 1135 100 1900 50 50 1135 100 Table 1 Safety clearances Installation and User Manual FONDA 9 3 4 Installation of control unit and sensor The control unit has been connected electrically by a cable to the sauna heater The control unit must be installed
5. for the sauna heater in question Conform to the specified safe clearance around the sauna heater Please refer to on page 8 There should be enough room around the sauna heater for maintenance purposes Also a doorway can be considered as a maintenance area 3 1 Installation Note The installation template is printed on the lid of the sauna heater box Follow the safety clearance specifications on page 8 when installing the sauna heater Thin panel is not a suitable mounting base The mounting base must be reinforced with timber behind the panel The minimum clearances specified on page 8 must be followed also in case the sauna room wall materials are incombustible An optional stand is available for floor installation The sauna heater must be fixed to the wall using the upper fas teners even if the stand is used For more detailed instructions see page 7 paragraph 3 2 Walls or ceilings must not be clad with fibre reinforced plaster board or other light weight cladding because they may cause a fire hazard A single sauna heater is allowed per a sauna room Installation and User Manual FONDA 7 3 2 Installation steps 1 Secure the wall mounts in the wall with the accompanying screws 6 x 40 and 6 x 16 Note the heater s minimum clearance If the sauna heater is going to be fitted with legs you don t need to attach the bottom brackets The top wall mounts should be installed so that the holes in the heater s locking screws
6. N L1 L1 L2 6 6 8 0 kW 230 V 3 Ee tt o4 34 e L1 L2 L3 6 6 8 0 kW 400V 415V 3N TTT t ttti N Li 12 13 amp 1 Syotto Natet Stromnetz Power input Puissance absorb e Vermogensingang Entrada de alimentaci n BxoaHoe HanpsKeHne Wej cie zasilania 2 Sahkolammityksen vuorottelu Alternering med elvarme Signal kontakt Signal contact Contact du signal Signaalcontact Contacto se al curHana KOHTaKT Sterowanie ogrzewaniem elektrycznym 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light clairage du sauna Saunaverlichting Luz de sauna Beixon nns ocBeujeuus O wietlenie sauny 4 Ohjauskeskus Styrpanel Steuergerat Control panel Panneau de commande Bedieningspaneel Panel de control lynbt ynpaBneuHmua Panel steruj cy 5 Tuntoelin Sensor F hler Sensor Capteur Sensor Czujnik laruuk 354 SKCP 3A Image 5 Wiring diagram for the sauna heater Installation and User Manual FONDA 2 ROHS Ymp rist nsuojeluun liittyvia ohjeita Taman tuotteen kayttoian paatyttya sita ei saa havittaa normaalin talousjatteen mukana vaan se on toimitettava sahko ja elektroniikkalaitteiden kierratykseen tarkoitettuun kerayspisteeseen Symboli tuotteessa kayttoohjeessa tai pakkauksessa tarkoittaa sita Valmistusaineet ovat kierratettavissa merkintansa mukaan Kaytettyjen laitteiden uudelleenkaytolla materiaalien hyd ynt misell ta
7. for taking a sauna bath 2 The door and the window are closed 3 The sauna heater is topped with stones that comply with the manufacturer s recommendations the heating elements are covered with stones and the stones are piled sparsely NOTE Ceramic rocks are not allowed 1 2 Operation of the sauna heater controls Refer to the specific control panel operating instructions For additional information about enjoying a sauna bath please visit our website at www helo fi 2 Information for users Persons with reduced physical and mental capacity sensory handicap or little experience and knowledge about how the device is operated e g children should only operate the device while supervised or according to instruc tions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a sauna room should be thermally well insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements in the sauna room such as decorative stone glass etc note that these ele ments may extend the pre heating period even though the sauna room is otherwise well insulated see page 6 section 3 Preparing for sauna heater installation Installation and User Manual FONDA 4 2 2 Rekommenderad ventilation i bastun
8. er that will not be covered by the war ranty gt A VY 3 E j AA YYX 3 DR XY K Oe 2 5 Electric heating toggle The electric heating toggle applies to homes with an electric heating system Sauna heater has a connection marked 55 for controlling the electric heating toggle Connector 55 and the heat ing elements are simultaneously live 230V 2 6 If the sauna heater will not heat up If the sauna heater will not heat up please check that the power is on the main fuses of the sauna heater are intact is there any error messages on the control panel In case of an error message on the control panel please refer to the control panel instructions THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES FOR THE FUTURE USER Installation and User Manual FONDA 3 Preparing for sauna heater installation Check the following before installing the sauna heater The ratio of the heater s input KW and the sauna room s volume m Volume recommendations are presented in Table 1 on page 8 The minimum and maximum volumes must not be exceeded The sauna room height must be a min of 1900 mm Uninsulated and masonry stone walls extend the preheating time Each square metre of plastered ceiling or wall surface adds 1 2 m to the sauna room s volume Check page 9 Table 2 for a suitable fuse size A and the correct diameter of the power supply cable mm
9. helo GENUINE SAUNA amp STEAM Installation and User Manual FONDA ELECTRIC SAUNA HEATER 0315 44 040518 0315 66 040518 0315 80 040518 CONTROL PANEL 1601 27 T1 314 SKCP 1 3C Installation and User Manual FONDA Contents 1 Quick instructions for use of the sauna heater 1 1 1 2 Check before taking a sauna bath Operation of the sauna heater controls 2 Information for users 2 1 2 2 2 3 2 4 2 5 2 6 Sauna room Rekommenderad ventilation i bastun Heating the sauna Sauna heater stones Electric heating toggle If the sauna heater will not heat up 3 Preparing for sauna heater installation 3 1 Installation 3 2 Installation steps 3 3 Safety distances 3 4 Installation of control unit and sensor 3 5 Connection of the sauna heater to the mains 3 6 Locating the connecting box for the connection cable in the sauna room 3 Principle image when T1 is used as control panel 3 8 Wiring diagram 2 ROHS Bilder och tabeller Image 1 Recommended sauna room ventilation Image 2 Safety clearances Image 3 Location for the connection box Image 4 Principle installation Image 5 Wiring diagram for the sauna heater Table 1 Safety clearances Table 2 Connection cable and fuses 10 11 12 13 10 11 12 Installation and User Manual FONDA 3 1 Quick instructions for use of the sauna heater 1 1 Check before taking a sauna bath 1 The sauna room is suitable
10. i muulla uudelleenk yt ll teet arvokkaan teon ymp rist mme hyv ksi Tuote palautetaan ilman kiuaskivi ja verhouskivi kierratyskeskukseen Tietoa kierratyspaikoista saat kuntasi palvelupisteesta Instructions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the instruction manual or the package refers to this The materials can be recycled according to the markings on them By reusing utilising the materials or by otherwise reusing old equipment you make an important contribution for the protection of our environment Please note that the product is returned to the recycling centre without any sauna rocks and soapstone cover Please contact the municipal administration with enquiries concerning the recycling place 13 Anvisningar for miljoskydd Denna produkt far inte kastas med vanliga hushallssopor nar den inte langre anvands Istallet ska den levereras till en atervinningsplats for elektriska och elektroniska apparater Symbolen pa produkten handboken eller forpackningen refererar till detta De olika materialen kan atervinnas enligt markningen pa dem Genom att ateranvanda nyttja materialen eller pa annat satt ateranvanda utsliten utrustning bidrar du till att skydda var miljo
11. ly and the air warms up evenly in the sauna room Do not put any objects on the sauna heater Do not dry clothes on the sauna heater or anywhere in its vi cinity Installation and User Manual FONDA 2 4 Sauna heater stones Quality stones meet the following requirements Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on the stones Stones should be rinsed before use in order to avoid odour and dust Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from Sauna stones should be large enough measuring about 50 100 mm to allow good ventilation between the stones This extends the useful life of the heating elements Sauna stones should be piled sparsely in order to enhance ventilation between the stones Do not bend the heating elements together or against the frame Rearrange the stones regularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 8 Any small stones in the package of stones must not be piled on the sauna heater The warranty does not cover defects resulting from poor ventilation caused by small and tightly packed stones Ceramic rocks are not allowed They may cause damage to the sauna heat
12. outside the sauna room The sensor is mounted to the sauna wall directly on the centre line of the sauna heater 40 mm from the ceiling NOTE If the wall on which the sensor is to be installed is made of highly heat insulating material e g concrete brick etc or if the wall is made of toughened glass the sensor can be installed directly above the heater on the heater s centre line viewed from both the front and from the side Deviations from the fitting dimensions specified can lead to a risk of fire The temperature limiter in the sensor interrupts the heater s temperature output if the heater s temperature increases to such an extent that it represents a danger for the sauna s wooden parts When the temperature has fallen the limiter can be reset by pressing the reset button Before resetting you must always investigate why the temperature limiter was triggered 3 5 Connection of the sauna heater to the mains The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations The sauna heater is connected with a semi permanent connection Use HO7RN F 60245 IEC 66 cables or a corre sponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection cable for the sauna heater A multipolar e g 7 pole cable is allowed if the voltage is the same In the absence of a separate control curren
13. t fuse the diameter of all cables must be the same i e in accordance with the front fuse The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater The maximum height for the connection box is 500 mm from the floor See page 10 If the connection box is located at over 500mm distance from the heater the maximum height is 1000mm from the floor Sauna heater insulation resistance The sauna heater heating elements may absorb moisture from air e g during storage This may cause leakage currents The moisture will be gone after a few heating sessions Do not connect the heater power supply through a ground fault interrupter However adhere to the effective electrical safety regulation when installing the sauna heater Effect Sauna Heaters Sauna Heaters Sauna Heaters connection connection connection cable cable cable HO7RN F HO7RN F HO7RN F 60245 IEC 66 60245 IEC 66 60245 IEC 66 mm a mm 400 415V 3N 230 240V 1N 2 Table 2 Connection cable and fuses Installation and User Manual FONDA 3 6 Locating the connecting box for the connection cable in the sauna room 500 mm Image 3 Location for the connection box A Specified minimum safety clearance 1 Recommended location for the connecting box 2 Silumin box recommended in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box