Home

TECHCONNECT TC2-MATRIXBRIDGE OWNERS MANUAL

image

Contents

1. Load Matrix Telnet API Command Log 08 46 13 receive devicelist is EX141 341B228000C3 EX141 341B228000C4 EX131 341B2280009C EX131 341B22800072 EX141 341B228000AD EX141 341B228000B5 08 46 12 receive ipsetting2 is ip4addr 192 168 11 243 netmask 255 255 0 0 gateway 192 168 11 1 08 46 12 receive ipsetting is ip4addr 169 254 1 2 netmask 255 255 0 0 gateway 169 254 1 254 08 46 12 result code 1 Welcome to use 08 45 27 Info WebSocket connection opened Firefox automatically sends some data to Mozilla so that we can improve your experience It includes three parts Matrix TX RX Settings and System Settings TC2 MATRIXBRIDGE manual en Matrix Click Load Matrix button a table comes up Matrix TX RX Settings System Settings RX TX SEx131 341B2280009 EX131 341B22800072 Wex1 41 341B228000B5 The first row shows TX the first column shows RX Description device is online Icon d device is offline M Shows TX and RX are linked Click the green bar it changes into blank which means TX and RX are disconnected L The red bar represents TX RX connecting is in processing The white bar represents correspondence TX and RX are not linked You can link them by clicking this white bar 10 TC2 MATRIXBRIDGE manual en TX RX Settings Select a device you want to configure Matrix TX RX Settings System Settings Device Settings Devices EX141 341B228000C3 EX141 341B228000C4 OEX
2. Subnet Mask 255 255 0 0 Default Gateway 169 254 1 254 Attention After pressing Apply this IP control box will automatically reboot for the settings to take effect Apply IP Setup A telnet client and a browser communication IP Address 192 168 11 243 Subnet Mask 255 255 0 0 Default Gateway 192 168 11 1 Attention After pressing Apply this IP control box will automatically reboot for the settings to take effect Apply IP Setup TX and RX communication IP Address 169 254 11 Subnet Mask 255 255 0 0 Default Gateway 169 254 1 254 Attention After pressing Apply this IP control box will automatically reboot for the settings to take effect Apply GUI Element Description IP Address The IP address for TX and RX communication Subnet Mask The subnet mask for TX and RX communication Default Gateway The default gateway for TX and RX communication 13 TC2 MATRIXBRIDGE manual en IP Setup A telnet client and a browser communication IP Address 192 168 11 243 Subnet Mask 255255 0 0 Default Gateway 192 168 11 1 Attention After pressing Apply this IP control box will automatically reboot for the settings to take effect GUI Element IP Address Subnet Mask Default Gateway Web Password GUI Element Web Password Debug Log 9 ON OFF Apply Description The IP address for Telnet client and web The subnet mask for Telnet client and web The default gatewa
3. 131 341B22800072 EX141 341B228000AD EX141 341B228000B5 Select a device you want to configure Reload Matrix TX RX Settings System Settings Device Settings Devices EX141 341B228000C3 EX141 341B228000C4 EX131 341B22800072 EX141 341B228000AD EX141 341B228000B5 Select a device you want to configure Reload IP Setup IP Mode Auto IP DHCP Static IP Address 169254 5 175 Subnet Mask 255255 0 0 m ao O Default Gateway 169254 0 254 Apply GUI Element Description Auto IP Obtain the IP address automatically DHCP The IP address is assigned by a DHCP server Static The IP address is manually configured IP Address The IP address of the TX RX Subnet Mask The subnet mask of the TX RX Default Gateway The default gateway of the TX RX 11 TC2 MATRIXBRIDGE manual en Alias Apply GUI Element Description Alias Give the TX RX a different name which would be easier to remember Note Alias cannot contain _ 8 EX131 EX363 EX373 EX383 EX393 TX EX141 EX403 RX Commands Factory Default Reboot GUI Element Description Factory Default Restore the TX RX to factory default settings Reboot Reboot the TX RX 12 TC2 MATRIXBRIDGE_manual_en System Settings In this page you can configure the IP Control Box Matrix TX RX Settings System Settings IP Setup TX and RX communication IP Address 169254 11
4. SK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE All products are designed and imported into the EU by Vision who is wholly owned by Azlan Logistics Ltd Registered in England Nr 04625566 at Lion House 4 Pioneer Business Park Clifton Moor York YO30 4GH WEEE Registration GD0046SY ous X OC DECLARATION OF ORIGIN All Vision products are made in the People s Republic of China PRC 2 TC2 MATRIXBRIDGE_manual_en USE ONLY DOMESTIC AC OUTLETS Connecting the unit to an outlet supplying a higher voltage may create a fire hazard HANDLE THE POWER CORD WITH CARE Do not disconnect the plug from the AC outlet by pulling the cord always pull the plug itself Pulling the cord may damage it If you do not intend to use your unit for any considerable length of time unplug the unit Do not place furniture or other heavy objects on the cord and try to avoid dropping heavy objects on it Do not tie a knot in the power cord Not only could the cord be damaged but a short circuit could also be caused with a conseguent fire hazard PLACE OF INSTALLATION Avoid installing this product under the following conditions e Moist or humid places e Places exposed to direct sunlight or close to heating equipment e Extremely cold locations e Places subject to excessive vibration or dust e Poorly ventilated places Do not expose this product to dripping or splashing DO NOT PLACE OBJECTS FILLED WITH LIQ
5. TECHCONNECT TC2 MATRIXBRIDGE OWNERS MANUAL WA Ja ll a D g fi re www visionaudiovisual com techconnect tc2 matrix 1 TC2 MATRIXBRIDGE_manual_en DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations to a CB Certification standard Vision commits to ensure all products are fully compliant with all applicable certification standards for sale in the EU and other participating countries The product described in this owner manual is in compliance with RoHS EU directive 2002 95 EC and WEEE EU directive 2002 96 EC standards This product should be returned to the place of purchase at the end of its useful life for recycling WARNINGS RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL user to the presence of uninsulated dangerous voltage within the product s enclosure that may be h The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the of sufficient magnitude to constitute a risk of electric shock to persons important operating and maintenance servicing instructions in the literature accompanying the 1 The exclamation point within an equilateral triangle is intended to alert the user to the presence of appliance WARNING TO REDUCE THE RI
6. UIDS ON OR NEAR THIS PRODUCT MOVING THE UNIT Before moving the unit be sure to pull out the power cord from the AC outlet and disconnect the interconnection cords with other units WARNING SIGNS If you detect an abnormal smell or smoke turn this product off immediately and unplug the power cord Contact your reseller or Vision PACKAGING Save all packing material It is essential for shipping in the event the unit ever needs repair IF ORIGINAL PACKAGING IS NOT USED TO RETURN THE UNIT TO THE SERVICE CENTRE DAMAGE IN TRANSIT WILL NOT BE COVERED BY WARRANTY 3 TC2 MATRIXBRIDGE_manual_en OVERVIEW This product is a protocol exchange device which allows 3 party software to control the Techconnect Matrix devices Only one of these devices is reguired per system Provides built in web server and Telnet API used in a third party controller Detects TX RX automatically Supports matrix switching Supports Video Wall Standards and protocols HTTP TCP IP Multicast 2 gt ai Do p ms gt 4 TC2 MATRIXBRIDGE manual en FRONT PANEL WORK O 6 6 RESET 123 4 1 Power LED steady red when the device is powered on 2 WORK LED steady blue when the device is working properly If red the device is rebooting 3 RESET button When the device is powered on press and hold this button for 5 seconds to restores to factory default settings 4 Label Write down the IP address of the device on the labe
7. ff I should be able to create multiple video wall configurations and then recall a configuration Is this possible I would like to use the PC software to create a video wall configuration and then save the configuration as a video wall name I would then send a telnet command to recall a video wall name This command could be set vw name A Except add vw name tx other add commands of VW are effective instantly The screen would change based on the commands Create and store multiple video wall configuration or recall the configuration effective are decided by your Third party software Any Third party party software could recall a specific configuration based on this API protocol and repeat corresponding add commands 6 How to add a 2 2 video wall A Before you use video wall you can assign an alias name to it just like this if you have 4 tx and 4 rx config set device alias EX131 AAAAAAAAAAAA tx1 config set device alias EX131 BBBBBBBBBBBBB tx2 15 TC2 MATRIXBRIDGE_manual_en config set device alias EX131 CCCCCCCCCCCCC tx3 config set device alias EX131 DDDDDDDDDDD tx4 config set device alias EX141 EEEEEEEEEEEEEEE rx1 config set device alias EX141 FFFFFFFFFFFFFFFFF rx2 config set device alias EX141 GGGGGGGGGGGG rx3 config set device alias EX141 HHHHHHHHHHH rx4 The first solution 1 vw add vw1 2 2 tx1 This command means add a video wall with two rows and two columns and assign a name vwl1 The blue one means r
8. l which comes with the device REAR PANEL 000660 oC ETHERNET RS232 5 6 7 5 ETHERNET RJ45 Port 6 RS232 For debugging 7 Power 5V 2A DC power supply input 5 TC2 MATRIXBRIDGE manual en HARDWARE INSTALLATION a a Connect all transmitters receivers and the bridge to the network Connect Source to TX Connect Displays to RX Power on all the devices Use Telnet or Web browser to manage bridge SOD Ethernet IP Control Box Switch Apple TV Xbox 6 TC2 MATRIXBRIDGE_manual_en SETUP Users can access the device through Web Telnet or a Third party controller Web To access the device through Web Management Page follow these steps 1 Enter 192 168 11 243 into a browser EB IP Control Box System Gras Onn cla Most Visited Getting Started Suggested Sites Web Slice Gallery Welcome to IP Control Box Web System Password 2 Enter a password admin by default click Login to access the device Notes e The IP address of the computer and IP Control Box should be in the same network subnet For example if the IP address of IP Control Box is 192 168 11 243 then the computer should be 192 168 11 X e The IP address of the IP Control Box can be changed through Web Management Page or Telnet e If the Web Management Page cannot be displayed please refer to FAQ 7 TC2 MATRIXBRIDGE_manual_en Telnet To access the device through Telnet foll
9. ow the green one means column 2 vw addvw1 rx1 1 1 rx2 1 2 rx3 2 1 rx4 2 2 This command means add some devices to the video wall vw1 and assign the position to it The second solution vw add vw1 layout 2 2 txi rx1 rx2 rx3 rx4 this command is the most simple to add a video wall Just need one line of command Both solutions are effective 7 How to use command vw bezelgap vw name ow oh vw vh A This command is incorrect The correct one is vw bezelgap vw name vw ow vh oh If your TV vw is 90 01 cm ow is 91 01 cm vh is 40 52 cm and oh is 42 52 cm First you need to change the unit to 0 1mm means 90 01cm 9001 0 1mm you just need to send vw bezelgap vwname 9001 9101 4052 4252 8 How to use the command vw pictureparam vw name h shift v shift h scale v scale tearing delay A This command is used for adjusting screen display The range of Tearing delay is 10000 16000 and unit is us 16 TC2 MATRIXBRIDGE_manual_en SPECIFICATIONS PRODUCT DIMENSIONS 141 x 115 x 26 mm length x width x height PRODUCT WEIGHT 420g CONSTRUCTION MATERIAL Metal COLOUR Black TECHNICAL DETAILS Control Method Web Telnet Third party control system ESD Protection 8kV air gap discharge 4kV contact discharge Surge Protection 1000 V Tested ten times respectively for the positive and negative voltages Operating Temperature Range 0 to 35 C Operating Humidity Range 10 to 90 Yo RH no condensation Power Con
10. ow these steps 1 Click Start menu go to Run Input cmd click OK e ypethe name of a program folder document or Internet resource and Windows will open it for you Open cmd HP This task will be created with administrative privileges Cancel Browse 2 Input telnet 192 168 11 243 press Enter a Administrator C Window Microsoft Windows Version 6 1 76811 Copyright c 2669 Microsoft Corporation Al rights reserved C Users Mdministratoritelnet 172 168 11 2434 This window will come up EN Telnet 192 168 11 24 welcome to use hdip system Notes e The IP address of the computer and IP Control Box should be in the same network subnet For example if the IP address of IP Control Box is 192 168 11 243 then the computer should be 192 168 11 X e If you use a third party controller you can access the device refer to the document API Command TC2 MATRIXBRIDGE_manual_en WEB CONFIGURATION The Web Management Page is designed to perform the functions to control the device in a user friendly interface Home Screen Open your browser enter 192 168 11 243 in the address bar and input the password admin by default click Login Welcome to IP Control Box Web System This window will open Firefox KI IP Control Box System 192 168 11 243 Most Visited Getting Started Suggested Sites _ Web Slice Gallery Matrix TX RX Settings System Settings
11. sumption 1 4 watts CONNECTIVITY 1 x RS 232 3 port phoenix 1 x Ethernet RJ45 1 x DC Power 1 x POWER SUPPLY 100 240v 50 60Hz AC 5 volt 2 amp COMPLIANCES RoHS WEEE CE EMC FCC ACCESSORIES INCLUDED Serial cable 5 x Labels 17 TC2 MATRIXBRIDGE manual en WARRANTY This product comes with a 2 year return to base warranty effective from the date of purchase This warranty applies only to the original purchaser and is not transferable For the avoidance of doubt this will be taken from the information held by the appointed national distributor at the point of sale If the product is DOA dead on arrival you have 21 days from purchase date to notify the national distributor via your AV reseller The liability of the manufacturer and its appointed service company is limited to the cost of repair and or replacement of the faulty unit under warranty except for death or injury EU85 374 EEC This warranty protects you against the following e Failure of any components including the power supply e Damage when the product is first removed from its packaging if reported within 24 hours of purchase If you find you do have a problem with this product you should contact the AV reseller you purchased this product from The original purchaser is responsible for shipment of the product to the manufacturer s appointed service centre for repair We will endeavour to return repaired units within 5 working days however this may not al
12. ways be possible in which case it will be returned as soon as practicably possible In line with our WEEE commitments the manufacturer endeavours to replace the faulty parts of the product rather than replacing the whole unit This warranty does not protect this product against faults caused by abuse misuse incorrect installation unstable or faulty power input which might be caused by ignoring the guidelines set out in this manual LEGAL DISCLAIMER Because we are committed to improving our products the details above may change without prior warning This User Manual is published without warranty and any improvements or changes to the User Manual necessitated by typographical errors inaccuracies of current information or improvements to programs and or equipment may be made at any time and without notice Such changes will be incorporated into new editions of the User Manual 18 TC2 MATRIXBRIDGE_manual_en
13. y for Telnet client and web Apply Description Login password for Web Management page The default password is admin Apply If Debug Log is enabled a file will be saved in the IP Control Box when some unexpected problem happened Commands Factory Default GUI Element Factory Default Reboot Shutdown Reboot Shutdown Description Restore the IP Control Box to factory default settings Reboot the IP Control Box Shutdown the IP Control Box 14 TC2 MATRIXBRIDGE_manual_en FAO 1 Why I cannot login the Web Management Page 1 Check the IP address of your computer The default IP address of the IP Control Box is 192 168 11 243 so the IP address of the computer should be 192 168 11 X 2 Check the Web browser It will work with Firefox Opera Safari Internet Explorer 11 or Chrome If the problem persists try to upgrade you browser to the latest version 2 How do I set the addressing type of the Transmitters and Receivers A The IP address of Transmitters and Receivers are obtained automatically the default method is Auto IP 3 When I send matrix commands how do I specify TX and RX IP address Alias or Hostname A You can specify them by Alias or Hostname They are unigue 4 What is the format of the command Simple ASCII terminated with a lt CR gt A Yes exactly 5 It looks like to create a video wall I would use the command add vw name Once a video wall is created how do I turn it on and o

Download Pdf Manuals

image

Related Search

Related Contents

資料3 共用品市場規模調査結果の概要・・・・・・・・・・・・・・・ 31(PDF形式)  MyPBXPro User Manual  Kingston Technology ValueRAM 8GB DDR3-1333MHz ECC  フロントスプリング 取扱説明書 注 意 事 項 注 意 事 項  テレビューティリティーキット TK-N53 取扱説明書/狂暴言証書  Sony VAIO VPCL2 User's Manual  Unità a nastro HP StorageWorks DAT  Electrolux 8490 D Ventilation Hood User Manual  Phone.com Setup Guide  WABL Stadium Scoring User Guide  

Copyright © All rights reserved.