Home

MANUALE UTENTE - USER GUIDE - MANUEL

image

Contents

1. for further details Technical specification appearance functionally and other product charateristics may change without notice Ks 2 lares KEYBOARD OPERATIONS Refer to the keyboard manual to use the ergo capsense keyboard and get familiar with the functions of its keys and circular scroll ACTIONS IN STAND BY MODE Six operations can be performed while the system is in stand by mode Detailed list of information by pressing the Enter key Partitions status by pressing the key Zones status by pressing the key Activation of a function by holding down the corresponding numeric key for 3 seconds Entering the PIN default PIN is 147258 Keyboard lock for cleaning hold the ESC key pressed for 3 seconds N os In stand by mode the following informations can be displayed by pressing the ENTER key If an alarm occurs it is possible to see which zone is in alarm if the nofices without PIN display is enabled List of armed if the system activation status display is enabled List of open zones if open zones real time display is enabled Information about the installer Use the circular scroll to browse through these lines To activate a function macro without entering the PIN keep the corresponding numeric key pressed for seconds This function must be enabled by the installer If the keyboard is not configured in the system the keyboard display does not show
2. the remote assistance the SMS that should be sent to the panel will be 147258m0 RECOGNIZED CODE EVENT The SMS format must follow this directives user code n Example with the default user PIN 147258 in order to generate the Recognized Code event the SMS that should be sent to the panel will be 147258n The SMS will generate the Recognized Code event and if programmed you will perform the actions associated with this event This feature is very useful if you want to diversify actions for example to activate oufputs that can be performed by different users Kg lares REMOTE CONTROL VIA WEB BROWSER lares integrated panels Model lares 16 IP lares 48 IP lares 128 IP integrate a web browser for remote management of the system via Internet Installer should program the panel and enable the service moreover if a static IP address is not available the system support dynamic IP address service protocol DynDNS that allows to communicate with the panel from any Internet point For security reasons to gain access to web server service an additional login via a username and a password is required CERTIFICAZIONI CERTIFICATIONS CERTIFICATIONS T 014 1th Edition 2003 A1 2002 A2 2003 A3 2005 EN50131 3 EN50131 6 EN50136 1 1 ENTE CERTIFICATORE D IMQ Sistemi di Sicurezza GRADO 3 CLASSE Il c 2002 95 EC Kg lares
3. the panel Following operation can be performed 1 Scenarios activation 2 Pay as you go balance on prepaid SIM card 3 Remote assistance 4 Generating Recognized Code event SCENARIOS ACTIVATION VIA SMS It is possible to activate up to 10 different scenarios simple sending an SMS to the panel The SMS format must follow this directives lt user code gt s lt scenario number gt or lt user code gt space lt scenario name gt lt gt For example let s suppose that we want scenario number 1 arming to be turned on by default user PIN 147258 The SMS that should be sent to the panel will be 147258s1 or 147258 arming It is possible to program up to 8 different numbers that the system could send back an SMS of acknowledge to after the arming is executed PAY AS YOU GO BALANCE ON PREPAID SIM CARD The SMS format must follow this directives lt user code gt c For example with the default user PIN 147258 The SMS that should be sent to the panel will be 147258c Within few minutes the device will send the required information Ks 16 lares REMOTE ASSISTANCE The SMS format must follow this directives user code m 0 1 For example with the default user PIN 147258 to enable the remote assistance the SMS that should be sent to the panel will be 147258m1 If programmed the panel will send to the installer the IP address received from the network For example with the default user PIN 147258 to disable
4. MANUALE UTENTE USER GUIDE MANUEL UTILISATEUR Centrali integrate Integrated Panels Centrale Integr e KSI1000016 300 KSI1100016 300 KSI1000048 300 KSI1100048 300 KSI1100128 300 innovation www kseniasecurity com INDICE Introduzione Operazioni da tastiera 7 Operazioni a riposo 7 Visualizzazione informazioni a riposo Ingresso PIN utente Scenari Men Principale Men Avanzato Operazioni con la chiave Men vocale da remoto Operazioni da remoto via SMS Controllo remoto via Web Introduction Keyboard operations Actions in stand by mode Display information in stand by mode Login by user pin Main menu Advanced menu Operations with key Remote vocal menu Remote operations via sms Remote control via web resine rece 31 TABLE DES MATIERES Introduction Operations au clavier Actions sur clavier en attente Affichage de l information en mode d attente stand by Login via code Menu principal Options avanc es Operations avec badge smartphone Menu vocal a distance Operations a distance via sms Controle a distance via web browser Kg lares COME EFFETTUARE LE OPERAZIONI HOW TO PERFORM THE OPERATIONS COMMENT EFFECTUER LES OPERATIONS INSERIRE CODICI INSERT CODES INSERER LES CODES Enter FIN
5. SCORRERE MEN SCROLL THE MENU FAIRE D FILER LE MENU Programming Zones Kg lares CONFERMARE LE OPERAZIONI TASTO ENTER CONFIRM THE OPERATION ENTER KEY CONFIRMER LES OPERATIONS TOUCHE ENTRER Partition ENTER 23 69 1 4 7 R USCIRE DALLE OPERAZIONI TASTO ESC EXIT FROM THE OPERATIONS ESC KEY SORTIE DE PROGRAMMATION TOUCHE ESC SYSTEM 12 30 61 61 12 ESC 5 8 3 6 9 F 1 4 7 WO Kg lares AVVICINARE LA CHIAVE ALLA TASTIERA APPROACH THETAGTO THE KEYPAD APPROCHER LE BADGE DU CLAVIER SYSTEM DK 12 58 91781712 AVVICINARE LA CHIAVE AL LETTORE volo APPROACH THE KEY TO THE volo OUTDOOR READER APPROCHER LE BADGE DU LECTEUR DE PROXIMITE volo Kg lares INTRODUCTION lares is a burglar alarm amp Home Automation system that can be controlled by means of an ergo LCD keyboard as well as remotely by telephone and even via the Internet through a built in WEB server This manual describes the operations that can be performed by the end user Installation of these systems must be carried out strictly in accordance with the instructions described in this manual and in compliance with the local laws and bylaws in force These devices hare been designed and made with the highest standards of quality and performance adopted by Ksenia Security Is recommended that the installed sy
6. aker volume keys tone and touch sensitivity ADVANCED OPTION Press the Enter key to gain access to the advanced functions Please refer to the next paragraph OVERTIME REQUEST Press the Enter key to do an overtime request and delay the arming of the system FAULTS STATUS Press the Enter key to display the detected faults you can browse through them using the circular scroll Any failure in the system memory will be erased showing fault status STOP CALLS Press the Enter key to stop any actions of the telephone dialer in consequence of an alarm calls SMS or e mail Kg lares OVERTIME REQUEST Press the Enter key to do an overtime request and delay the arming of the system FAULTS STATUS Press the Enter key to display the detected faults you can browse through them using the circular scroll Any failure in the system memory will be erased showing fault status GEMINO STATUS Press the Enter key to display the GSM operator signal strength your remaining credit and the expiry of the SIM This item is available only if there is a configured gemino BUS into the system STOP CALLS Press the Enter key to stop any actions of the telephone dialer in consequence of an alarm calls SMS or e mail Ks lares ADVANCED MENU The advanced browsing menu consists of the following items which can be browsed using the circular scroll This menu is available only if the entered PIN has been programmed with the Main Code
7. any information and the user PIN is disabled In this way login is permitted only through the installer PIN Ky lares DISPLAY INFORMATION IN STAND BY MODE In stand by mode the upper line of the display shows the system status The informations are displayed in the following order of priority MAINTENANCE TAMPER ALARM MISSING PERIPH TAMPER MEMORY ALARM MEMORY SYSTEM FAULTS FAULT MEMORY ENTRY TIME EXIT TIME WARNING TIME PHONE CALL ACTIVE USB CONNECTION REMOTE ASS ZONE BYP TEST REMOTE LISTENING SYSTEM OK maintenance by the installator In this case no intrusion alarm nor tamper alarm will go off tamper condition on at least one of the partitions enabled for the keypad an alarm is active on at least one of the partitions enabled for the keypad at least one KS BUS peripheral is missing tamper memory on at least one of the partitions enabled for the keypad alarm memory on at least one of the partitions enabled for the keypad the system has at least one fault there is a fault in memory entry time is active on at least one of the partitions enabled for the keypad exit time is active on at least one of the partitions enabled for the keypad warning time is active on the partitions enabled for the keypad a telephone call is in progress the panel is connected to the pc by USB port or a flash USB key is connected to the panel remote assistancee is enable on the panel at least one zon
8. e is in test or Manually bypassed the remote listening from the keypad microphone is active there are no faults Ks lares During programming it is possible to disable the system status display on the first row when the keypad is in stand by In this case to display the status of the system you must enter a valid user PIN or approach a programmed key to the keypad with this setting when the system is disarmed on the first row it displays the strings Alerts queued or Ksenia security depending of whether there are or there are not anomalies When the system is armed it always displays the string Ksenia Security The lower line of the display shows pieces of information that can be tailored by the installer on each keyboard 1 Date and time 2 System activation status On or Off 3 Outdoor temperature requires at least an imago BUS outdoor siren 4 Indoor temperature requires at least a radius BUS indoor siren 5 GSM operator requires a gemino BUS link 6 Real time indication of open zones NOTE in the user menu if no key is pressed within 30 seconds the keyboard will automatically return to the stand by mode Kg lares In the user menu you can browse through the following items using the circular scroll LOGIN BY USER PIN SCENARIOS After the user digit user PIN that is always 6 digit long the keypad will show the enabled functions starting from the most used one depending on the
9. enabled choices and access is granted to the first level of the menu Let s assume for example that two functions are enabled on the keyboard assigned to key 0 system off and to key 1 system on respectively the keyboard shows the function to be applied or the most frequently used one if you don t press any key within 3 seconds the function shown on the display is performed automatically and the keyboard returns to the stand by modes SHORTCUTS Press a numeric key to activate the corresponding function or press the key to go into the main menu SEQUENTIAL EXECUTION OF MULTIPLE SCENARIOS To execute multiple scenarios in sequential mode simply press the enter key after the first scenario without having to re enter user code 2 On basis step on Bus Peripherals ergo x Macro Functions 3 If the proposed function is not to be applied use the circular scroll to move to the desired action and confirm it using the Enter key Ks 10 lares MAIN MENU RESET ALARM Press the Enter key to reset any active alarm and delete the alarm record PARTITION STATUS Press the Enter key to display the activation status on off of all partitions ZONE STATUS Press the Enter key to display the real time activation status on off of all zones CHANGE PIN Press the Enter key to change the access PIN ERGO OPTIONS Press the Enter key to modify the settings of the keyboard you are operating on namely display backlight loudspe
10. parameter enabled EVENT LOGGER Event record display Press Enter to display the record you can browse through the events starting from the last recorded one For additional details of the event press the Enter key again SCHEDULER In this menu it is possible to enable disable the autoarming feature ENABLE MAINT In this menu you can enable the installer to log in for system maintenance If this option is set to OFF the installer will have no access to the system for any operation whatsoever REMOTE ASS In this menu it is possible to enable disable the remote assistance TEST EVENT Press Enter to generate the Periodic Test event PHONE BOOK In this menu it is possible to program the phone numbers to call DATE amp TIME After pressing the Enter key on this item you will be able to change the system s date and time simply by operating the circular scroll To skip from one field to the other do not to press any key for 3 seconds VOICE MENU In this menu you can enable the voice menu which enables the system to be Managed remotely by telephone For the functions available in this section see next paragraph Kg lares MANAGE CODES In this menu you can modify the enable function and the user PIN codes enabled in the same partitions as login code REPLACE LEXAN This menu allows the colour lexan layer of the keyboard to be replaced without triggering a tampering alarm To open and close the cover you should follow
11. stem should be completely tested at least once a month Test procedures depends on the system configuration Ask to the installer for the procedures to be followed Ksenia Security srl shall not be responsible for damage arising from improper installation or maintenance by unauthorized personnel The content of this guide can change without prior notice from KSENIA SECURITY Information for users Disposal RAEE WEEE Directive Warning Do not use an ordinary dustbin to dispose of this equipment Used electrical and electronic equipment must be treated separately in accordance with the relative legislation which requires the proper treatment recovery and recycling of used electrical and electronic equipment Following the implementation of directives in member states private households within the EU may return their used electrical and electronic equipment to designated collection facilities free of charge Local retailers may also accept used products free of charge if a similar product is purchased from them If used electrical or electronic equipment has batteries or accumulators these must be disposed of separately according to local provisions Correct disposal of this product guarantees it undergoes the necessary treatment recovery and recycling This prevents any potential negative effects on both the environment and public health which may arise through the inappropriate handling of waste Please contact your local authority
12. the instructions provided in the keyboard manual OPERATIONS WITH KEY The transponder key or your own NFC telephone can be used instead of the keyboard keys to activate the codes to access the user menu bring a valid key near the reading zone of the keyboard located at top right Ks lares REMOTE VOCAL MENU In the case that a gemino BUS or a pontis communication interface is configured in the system it is possible to use a vocally guided remote menu which affords the following operations 1 Listening to the monitored environment from the keyboard panel microphone 2 Getting information on the status of the zones and inclusion exclusion of them 3 Getting information on the status of the partitions 4 Activating functions output and or arming disarming panel The menu is completely voice guided and the keys to be pressed are shown for every operation Generally any operation is confirmed by pressing the key and cancelled by pressing the key on your telephone There are three different ways to gain access to the vocally guided remote menu 1 Calling the phone number of the SIM installed on the gemino BUS if the responder is enabled 2 Calling the PSTN number the pontis interface is connected to 3 Press the key during an incoming call received from the system Kg lares REMOTE OPERATIONS VIA SMS If the panel is connected to a gemino BUS communicator some operations can be done remotely sending SMS to