Home

Operating Instructions - PACTware/DTM Collection 12

image

Contents

1. Fig 4 Project with VEGAPULS Project creation VEGAMET 391 with sensor The following example shows a typical project containing a sensor connected to a VEGAMET 391 Communication to VEGAMET 391 is carried out in this example via USB We recommend using the VEGA project assistant as this considerably facilitates project creation and helps avoid errors All participating components are found automati cally and integrated into the project In case the planning is nevertheless carried out manually e g when creating an offline project the following DTMs must be added to the project tree 1 Select in the device catalogue first of all the VEGA USB DTM from the category Driver and transfer it for example by double clicking to the project window 2 Selectthe VEGAMET 391 DTM from the category Gateways and transfer it into the project window 3 Select the requested sensor DTM from the category Device and transfer it to the project window 12 PACTware DTM Collection 12 2011 Installation first steps KEEEEE NG ETC8C 28243 EN 111111 Connection VEGAMET 624 via Ethernet 5 Operation 4 Now open the DTM by double clicking on the sensor in the project window and carry out the desired settings see chapter Parameter adjustment ixi File Edit View Project Device Extras Window Help Jac a m ge gi S a5 s jj Sensor S E Al Devices Ei i PACTware Consortium e V
2. Fig 6 Project VEGAMET with VEGAPULS Project creation VEGALOG and Profibus PA sensor The following example shows a typical VEGALOG project with EP card and Profibus sensors We recommend using the VEGA project assistant this facilitates the creation of projects considerably and errors during addressing of the VEGALOG module cards and sensors are avoided All existing cards are found automatically and added to the project All connected Profibus sensors are also taken over automatically into the project In case the planning is nevertheless carried out manually e g when creating an offline project the following DTMs must be added to the project tree 1 First of all a driver must be selected by which the communication via the PC can be carried out Select the VEGA Ethernet DTM from the instrument catalogue With this driver the connection to VEGACOM 558 in the VEGALOG 571 processing system is established When the VEGA Ethernet DTM in the project tree is selected you can later adjust the IP address for the VEGACOM 558 module card in the PACTware menu under Device data Add l functions Change DTM adaresses The implementation of this setting is only possible if a suitable DTM e g VEGACOM 558 has already been added to the project tree 2 Finally the DTM VEGALOG 571 must be added This DTM represents the VEGALOG 571 processing system In this DTM measurement loops are created and processed later on 14 P
3. VEGA Grieshaber KG my Device Driver i Gateway B Vendor Group Type Protocol All Devices WEGA Grieshaber KG Device 4 VEGAPULS 54 VBUS VEGAPULS 56 HART g VEGAPULS 56 Profibus PROFIBUS DP V1 YYO Ei VEGAPULS 56 VBUS VEGAPULS 61 FF 4 VEGAPULS 61 HART VEGAPULS 61 Profibus PROFIBUS DP V1 YVO VEGAPULS 62 FF WWO Protocol HART VVO Protocol YVO Protocol FF H1 VVO Protocol HART WVO Protocol l FF H1 O Protocol IT Show all devices 4 E Update device catalog Info Add 35 scewseruss Pwa Administrator Fig 5 Project with VEGAPULS Project creation VEGAMET 624 with sensor The following example shows a typical project containing a sensor connected to a VEGAMET 624 Communication to VEGAMET 624 is carried out in this example via network and Ethernet We recommend using the VEGA project assistant as this considerably facilitates project creation and helps avoid errors All participating components are found automatically and integrated into the project In case the planning is nevertheless carried out manually e g when creating an offline project the following DTMs must be added to the project tree 1 Selectin the device catalogue first of all the VEGA Ethernet DTM from the category Driver and transfer it for example by double clicking to the project window 2 Select the VEGAMET 624 DTM from the category Gate
4. 6 Copyright The proprietary rights and the copyright to DTM Collection including the accompanying printed material and all copies belong to VEGA or its suppliers and are protected in particular by German copyright laws and international copyright agreements as well as relevant interna tional property rights agreements in particular TRIPS RBU and WCT along with other laws and agreements on intellectual property 7 Miscellaneous As far as no other regulations are mentioned elsewhere in this document the general terms of sale delivery and payment of VEGA www vega com agb apply these are an inseparable component of the user agreement and the user must agree to abide by them German law applies here under exclusion of international civil law Place of jurisdiction is Mannheim PACTware DTM Collection 12 2011 Installation first steps 21 Index INDEX D V DotNet 5 8 VEGACONNECT 11 DTM 5 6 10 Collection 5 Full version 6 Standard version 6 E Ethernet 13 14 Export 6 F FDT 5 l Import 6 L License agreement 6 Login 10 Multiviewer 6 O Offline mode 11 15 Online help 16 Online mode 15 P PACTware 5 10 Project 10 Password 10 Project assistant 10 S Software update 10 17 System requirements 8 T Tank calculation 6 U USB 12 User administration 10 User name 10 22 PACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 11111
5. PACTware or the DTM Collection on your PC proceed as follows 1 Select item Software in the Control Panel can be reached via Start Settings Control Panel 2 Select from the list PACTware or the respective DTM and push the button Modify Remove 3 Carry out the deinstallation in the way suggested by the assistant and complete the procedure with a Windows restart 7 2 Disposal Please dispose of the data carriers and the packaging material via specialised recycling companies 18 PACTware DTM Collection 12 2011 Installation first steps LELLELL NS 728 28243 EN 111111 VEGA 8 Supplement 8 Supplement 8 1 Technical data System requirements Hardware Processor Intel Pentium AMD 1 GHz or higher Memory At least 1 GB RAM or higher Hard disk At least 1 GB free memory Mouse Microsoft compatible Resolution of the graphic at least 1024 x 768 Interfaces RS232 USB Ethernet Software Operating system Windows XP Windows Vista Windows 7 32 and 64 Bit Additional software Internet Explorer 6 0 or higher Microsoft NET Framework 2 0 PACTware DTM Collection 12 2011 Installation first steps 19 8 Supplement VEGA 8 2 License agreements 8 2 1 License agreement for VEGA DTM Collection The DTM Collection consists of the actual software and depending on the scope of delivery the accompanying storage media as well as the corresponding documentation such as online help etc This end u
6. project assistant the connected instruments are identified automatically and integrated into the PACTware project For this only an online connection to the respective instruments is necessary The VEGA project assistant is opened from the PACTware menu bar under Project VEGA project assistant The window VEGA project assistant opens and you only have to select the requested interface for automatic generation of the project If only one instrument is connected to the selected interface the DTM parameter adjustment window will be opened automatically and the device data loaded You can find further information on how to use the VEGA project assistant in the corresponding online help The online help can be opened directly from the window VEGA project assistant 10 PACTware DTM Collection 12 2011 Installation first steps LLLLLL NA E768 28243 EN 111111 5 Operation Create a project ma nually Connection of sensor via VEGACONNECT P PACTware File Edit View Project Device Extras Window Help 9 Ag 1X9 BA b VEGA project assistant De HOST PC O R5232 M create new project DEJA TCP IP connect devices Online OusB O load device data automatically I Limit network search Close window automatically LAng lt NONAME gt Administrator Fig 3 Project assistant Even when instruments that are to be parameterised are not yet available or connected the proj
7. 1 Index PACTware DTM Collection 12 2011 Installation first steps 23 VEGA Printing date VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone 49 7836 50 0 Fax 49 7836 50 201 E mail info de vega com www vega com 0 cce All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able at the time of printing VEGA Grieshaber KG Schiltach Germany 2011 Subject to change without prior notice 28243 EN 111111
8. 11111 1 About this document 1 About this document 1 1 Function This operating instructions manual provides all the information you need for installation and commissioning Please read this information before setting up the instrument and keep this manual accessible in the immediate vicinity of the device 1 2 Target group This operating instructions manual is directed to trained qualified personnel The contents of this manual should be made available to these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution If this warning is ignored faults or malfunctions can result Warning If this warning is ignored injury to persons and or serious damage to the instrument can result Danger If this warning is ignored serious injury to persons and or destruction of the instrument can result Ex applications This symbol indicates special instructions for Ex applications List The dot set in front indicates a list with no implied sequence Action This arrow indicates a single action Sequence Numbers set in front indicate successive steps in a procedure PACTware DTM Collection 12 2011 Installation first steps 2 For your safety 2 For your safety 2 1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the p
9. ACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 111111 5 Operation When the VEGALOG 571 DTM in the project tree is selected you can later adjust the card addresses for the VEGALOG module cards in the PACTware menu under Device data Add l functions Change DTM addresses The implementation of this setting is only possible if a corresponding DTM e g VEGACOM 558 has already been added to the project tree 3 Then the DTMs for the individual VEGALOG module cards must be added to the project tree These are in this example VEGALOG CPU VEGACOM 558 VEGALOG 571 EP 4 The two DTM types VEGALOG 571 EP and VEGALOG 571 EV are VEGALOG module cards for connection of digitally commu nicating VEGA sensors This means appropriate sensor DTMs can be added to these cards Select the suitable sensor DTM from the device catalogue and transfer it into the project window If the sensor is already connected it is possible to search for it with PACTware In this case the VEGALOG 571 DTM must be in online mode right mouse key Connect Then the automatic search function can be started via the right mouse key Add functions Instrument search sc PW Project COM558 LOG PW3 PACTware ODE File Egt View Project Device Extras Window Help AI ow 0 Made 1 Project ax i Device catalog Ts E at Devices All DevicesiVEGA Grieshaber KG Device amp T CodeWirights GmbH Devis AE A w Bl ics
10. GmbH muse e m eem nm gie enn cfl vecatocs7 ceu Softing AG VEGASON 56 Profibus PROFIBUS_DPV1 VVO Protocol vecacomsss 3 gs VEGA Grieshaber KG Vj VEGASON 66 VBUS VVO Protocol amp vecaLoc sz EP Ed VEGASON 61 FF FF H1 VVO Protocol 2 VEGABAR 64 PA E Driver j VEGASON 81 HART HART VVO Protocol VEGALEX 65 PA Qi Gateway VEGASON 61 Profibus PROFIBUS DP VI VVO Protocol VEGAPULS 62 PA VEGASON62FF FF H1 VVO Protocol I VEGAPULS 62 PA Group we A j amp VEGASON 62 HART HART VVO Protocol PRGISI ROFIBUS DI O Prot E VEGASON 62 PA 7 VEGASON 62 Profibus PROFIBUS DP V1 VVO Protocol IRA Show all devices gt Update device catalog me XP SCPW Project COM558 Administrator Fig 7 Project VEGALOG 571 with Profibus PA sensors 5 4 Parameter adjustment After the project is created the parameter adjustment of the instrument can be started This is done via double click to the requested DTM in the project window or via the right mouse key by selecting Parameter In the following procedure a difference is made between offline and online mode Offline mode In offline mode the project can be prepared created and stored without connected instruments Later on in online mode these data can be transmitted to the instruments ready for operation PACTware DTM Collection 12 2011 Installation first steps 15 5 Operation VEGA bile Online mode In
11. Tware DTM Collection 12 2011 Installation first steps 9 5 Operation pio Create a project auto matically 5 Operation 5 1 Start PACTware Start PACTware via the Windows start menu In the standard setting it is not necessary to enter a user name and a password If this is requested you can assign various users with different rights and assign a password under the PACTware menu item Extras User administration Information To ensure that all instrument functions are supported you should always use the latest DTM Collection Furthermore not all of the described functions are always included in older firmware versions For many instruments the latest instrument software can be down loaded from our homepage The transfer of the instrument software is carried out via PACTware A description of the update procedure is also available in the Internet 5 2 Create a project Starting point for the adjustment of all types of field devices is the partial or complete imaging of the device network in a PACTware project This device network can be created automatically or manually and is displayed in the project window The easiest and quickest way to create an instrument network in the project window of PACTware is via the VEGA project assistant The VEGA project assistant is a manufacturer specific extension module for PACTware It is part of each VEGA DTM installation package and is installed automatically By means of the VEGA
12. VEGA Operating Instructions PACTware DTM Collection 12 2011 Installation first steps Document ID 28243 Indication and adjustment Contents 1 About this document dad FUNGON s cesa esee dd be ed ERROR om eS 3 1 2 Targetgroup s ce cutie dad aie mh Dare ee ees 3 1 3 Symbolismused era 3 2 For your safety 2 4 Authorised personnel 4 2 2 Appropriate USE 4 2 3 Warning about misuse LL 4 2 4 General safety instructions 4 2 5 Environmental instructions 4 3 Product description 3 1 Structure ee ee eae ee eee eae ee 5 3 2 What is PACTware FDT DTM 5 3 3 VEGA DTM iii ek HE exu RR 6 3 4 Storage and transport 7 4 Software installation 4 314 System requirements 8 4 2 Installation of PACTware and DTM 8 5 Operation 5 1 Stat PACTware LL 10 5 2 Create aproject 2c LL 10 5 3 Project examples 11 5 4 Parameter adjustment llllllssslsn 15 6 Maintenance and fault rectification 6 1 Maintenance Update a nn anaana anaana 17 6 2 Remove iinterferences lll llle 17 7 Deinstallation of PACTware VEGA DTMs 7 1 Deinstallation procedure 18 71 2 DISposal ia 500 2 oe eae RRRRRE EU ER 18 8 Supplement 8 1 Technical data System requirements 19 8 2 License agreements 0 20 Editing status 2011 11 11 2 PACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 1
13. a double click on the file autorun exe In the opening installation assistant you now select the requested language This selection can be modified after installation In the next window you select Standard or User defined With the standard installation only the components required for VEGA instruments are installed If User defined is selected the available DTM packages can be selected individually in the following window Start the actual installation process via the button nstallation Note For the installation of PACTware Microsoft NET Frameworks 2 0 is a prerequisite The installation assistant checks automatically if NET PACTware and the VEGA plics DTMs are already installed If that is the case this will be marked in the respective window and the programs will not be installed again PACTware DTM Collection 12 2011 Installation first steps LELLELL NS 728 28243 EN 111111 VEGA 4 Software installation Visit our homepage www veaa com Standard installation Installs all components of the VEGA DTM on your PC Custom installation na ts Vai may choose mi dial components to be installed m ecommended for experienced users plics o ReadMe _ _ Continue Finish Fig 1 Installation assistant Vist our homepage www veaa com f NET Framework 2 0 PACTware 4 0 VEGA DTM Back Installation Finish Fig 2 Installation assistant PAC
14. also part of the standard version In the full version there is also an extended print function for complete project documentation as well as a save function for measured value and echo curves In addition there is a tank calculation program as well as a multiviewer for display and analysis of the saved measured value and echo curves The standard version is available as a free of charge download from our homepage The full version is available on CD from the agency serving you The licence regulations allow you to copy a VEGA DTM any number of times and use it on any number of computers as long as you are using the standard version The full version may be copied a number of times and can be installed on several computers however may not be used by more than one user at a time VEGA offers individual DTMs for more than 100 instrument types all of them are installed via a common setup program VEGA USB VEGA Ethernet VEGA RS232 VEGACONNECT VEGABAR 50 60 VEGACAL 60 VEGAFLEX 60 VEGAPULS 60 VEGASON 60 VEGABAR 40 D80 Serie VEGAFLEX 50 VEGAPULS 40 50 VEGASON 50 VEGAMET VEGASCAN VEGALOG PLICSRADIO PLICSMOBILE PROTRAC PACTware DTM Collection 12 2011 Installation first steps LELLELL NS 728 28243 EN 111111 VEGA 3 Product description e VEGA Modbus Serial 3 4 Storage and transport Packaging The packaging consists of easily separable monomaterials These materials are environment friendly and recyclable Di
15. ct the following DTMs must be added to the project tree PACTware DTM Collection 12 2011 Installation first steps 11 5 Operation VEGA Connection VEGAMET 391 via USB 1 Select in the device catalogue first of all the VEGACONNECT 4 DTM from the category Driver and transfer it for example by double clicking to the project window 2 Select the requested sensor DTM from the category Device and transfer it to the project window You are asked for HART or I2C depending on the connection If VEGACONNECT is connected directly to the sensor select type 2C When connecting via the 4 20 mA cable type HART must be selected 3 Now open the DTM by double clicking on the sensor in the project window and carry out the desired settings see chapter Parameter adjustment ixi File Edit View Project Device Extras Window Help JO ga alo LL G 393 Bas All Devices YEGA Grieshaber KG HT Veamos or rronbes 4 VEGAPULS 54 VBUS WWO Protocol 4 VEGAPULS 56 HART HART VVO Protocol VEGAPULS 56 Profibus PROFIBUS DP V1 YYO 4 VEGAPULS 56 VBUS VVO Protocol j VEGAPULS 61 FF FF H1 YVO Protocol 04 VEGAPULS 61 HART HART VVO Protocol md j VEGAPULS 61 Profibus PROFIBUS DPJV1 WO j VEGAPULS 62 FF FF H1 VVO Protocol Vendor Group Type Protocol IT Show all devices 4 Y Update device catalog Info Add AB scpwecos psez pw3 Administrator
16. ect can be created manually offline operation All DTMs installed on the PC are displayed in the device catalogue The DTMs usually have the same names as the instru ments that can be adjusted with them For a better overview the device catalogue is divided into different subgroups On the upper level the manufacturers of the respective DTMs appear first Below the DTMs are divided into different function categories such as Driver Gateway and Device To create a project in the project window paste in the DTMs from the instrument catalogue one DTM for each actually used instrument The entry HOST PC is the starting point for pasting in the DTMs The requested DTM can be brought over from the instrument catalogue to the project window with a double click or Drag and Drop In the project window you can change the names of the selected instruments for better differentiation If the project window or the instrument catalogue are not visible they can be activated in the menu bar under View 5 3 Project examples Project creation for a VEGA sensor The following example shows a typical project containing a sensor connected e g to a PLC We recommend using the VEGA project assistant as this considerably facilitates project creation and helps avoid errors All necessary components are found automatically and integrated in the project In case the planning is nevertheless carried out manually e g when creating an offline proje
17. equires a supporting program like PACTware from which it can run The VEGA DTM Collection a software package consisting of PACTware with VEGA DTM as well as various standard communica tion DTMs is the adjustment software for all currently available communication capable VEGA sensors Also VEGAMET 391 VEGAMET 624 625 signal conditioning instruments VEGASCAN 693 as well as all instruments of PLICSRADIO and PLICSMOBILE series can be operated completely via the corresponding DTM For VEGALOG 571 processing systems with DTM CPU CPU card from version 2 0 there is also complete DTM support PACTware DTM Collection 12 2011 Installation first steps 5 3 Product description VEGA Parameter adjustment of the VEGAMET series 500 and 614 signal conditioning instruments as well as VEGALOG 571 with CPU version lt 2 0 is not supported For paramerter adjustment of these instruments the parameter adjustment software VVO is required Access to the digital sensors Profibus PA VBUS connected to VEGALOG 571 is possible with the VEGALOG 571 DTM independent of the software version 3 3 VEGA DTM The device DTMs are available as a free of charge standard version and as a full version that must be purchased In the standard version all functions for complete setup are already included An assistent for simple project configuration simplifies the adjustment considerably Saving printing the project as well as import export functions are
18. gt Admin Eg Administrator istrator Fig 8 DTM view VEGAPULS 62 HART Information Detailed explanations on parameter adjustment and project creation are available in the online help of PACTware and the DTMs Also consult the operating instructions manual of the corresponding instrument for setup and correct parameter adjustment 16 PACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 111111 6 Maintenance and fault rectification 6 Maintenance and fault rectification 6 1 Maintenance Update PACTware and VEGA DTMs are maintenance free For the purpose of error removal or integration of new functions software updates will be available in certain cases When new sensor types become available the suitable DTMs will be included in the current DTM Collection which can be downloaded from the Internet Information on our homepage www vega com 6 2 Remove interferences If glitches occur PACTware and VEGA DTM generate their own fault messages with corresponding explanations Fault messages generated in the sensor and sent to the DTM are described in the corresponding sensor operating instructions manual or in the online help of the DTM PACTware DTM Collection 12 2011 Installation first steps 17 7 Deinstallation of PACTware VEGA DTMs VEGA 7 Deinstallation of PACTware VEGA DTMs 7 1 Deinstallation procedure If you want to deinstall
19. lant operator During work on and with the device the required personal protective equipment must always be worn 2 2 Appropriate use PACTware Process Automation Configuration Tool is a manufacturer and fieldbus independent software for adjustment of all types of field instruments The corresponding VEGA instruments can be adjusted with the DTMs Device Type Manager supplied by VEGA 2 3 Warning about misuse Inappropriate or incorrect use of an instrument adjusted with PACTware can give rise to application specific hazards e g vessel overfill or damage to system components through incorrect mounting or setting 2 4 General safety instructions Installation and use of the software are carried out at your own risk We do not accept liability for consequential damage 2 5 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental protection The environment management system is certified according to DIN EN ISO 14001 Please help us fulfil this obligation by observing the environmental instructions in this manual e Chapter Packaging transport and storage e Chapter Disposal PACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 111111 3 Product description Scope of delivery PACTware FDT DTM DTM Collecti
20. mputer but cannot be used by more than one user at the same time 3 Warranty For the DTM Collection as Standard version VEGA is only liable for intention and gross negligence 20 PACTware DTM Collection 12 2011 Installation first steps KEEEEL NG ETC8C 28243 EN 111111 8 Supplement 4 Restrictions The user agrees not to change reverse compile or compile the software nor extract any parts The user agress not to rent or lease the software nor use the software different to the regulations of this agreement by himself or third parties On the basis of this user agreement the user is authorized to transfer his rights to the DTM Collection as full version to third parties under the condition that the complete software product is transferred including all components the storage media and the printed material and that the third party agrees to the terms of this user agreement before using the software product The user is obliged to make a written agreement with the third party that corresponds to the regulations of this agreement 5 Right of termination Notwithstanding other rights VEGA is authorized to terminate this user agreement if the user violates the regulations of the agreement In such case the user is obliged to deinstall the software immediately and destroy or give back to VEGA all copies of the software product and all of its components particularly the software product certificates
21. on 3 Product description 3 1 Structure The scope of delivery encompasses e Data medium DTM Collection Microsoft NET Framework 2 0 The current PACTware version all currently available VEGA DTMs in free of charge standard version HART protocol driver from Codewrights GmbH Generic HART DTM from ICS GmbH Softing Profibus DTM Operating Instructions Installation first steps 3 2 What is PACTware FDT DTM PACTware Process Automation Configuration Tool is manufacturer and fieldbus independent software for adjustment of all types of field instruments The DTMs Device Type Manager of the respective field device manufacturers are integrated into this open freely available supporting program via the interface specification FDT 1 21 To adjust a field device a DTM corresponding to the instrument type is always required this DTM is developed and sold by the respective field device manufacturer FDT Field Device Tool is a standardised interface description that describes the interaction between DTM and frame application e g PACTware FDT controls the data exchange between the different DTMs and the supporting program The DTM Device Type Manager is the actual adjustment module for sensors and field components It contains all instrument specific data and functions of a sensor type and delivers all graphic elements and dialogues for adjustment A DTM is not a stand alone executable software but r
22. online mode the instruments on which the parameter adjustment is to be carried out must be connected and ready for operation By selecting the appropriate DTM with the right mouse key and the command Connect the online mode is set up for operation After double clicking to the DTM connection is initiated which simulta neously checks the communication the sensor type and additional parameters If necessary all parameters of the instrument will be transferred automatically Via the PACTware menu item Read data from device all parameters of the instruments can be loaded anytime All modifications which are carried out will be stored automatically in the instruments after pushing the OK or Accept button Sensor Parametrierung Device name VEGAPULS 62 HART VEBA Description Radar sensor for continuous level measurement with horn antenna Measurement loop name Sensor Dee a gt Ej Setup Application Min max adjustment Damping Current output E Display E Diagnostics E Additional settings Info Min max adjustment Set distances for level percentages Max adjustment c gt Distance A Min adjustment gt Distance B Software version Serial number Max adjustment in percent 10000 Distance A max adjustment 0 000 m OFFLINE Min adjustment in percent 000 x Distance B min adjustment 20 000 m ok cancel Apply Ip Disconnected Data set mal aR lt ioname
23. ser licence agreement is a contract between the user either as a natural person or a legal entity and VEGA Grieshaber KG Schiltach VEGA for the software product VEGA DTM Collection The VEGA DTM Collection is available as Standard version or Full version In the Standard version all standard functions are available In the Full version the storing and printing of data recorded in the sensor such as measured values events or echo curves is also possible The Full version also contains the programs MultiViewer as well as Tank Calculation When the user installs copies or otherwise uses the VEGA DTM Collection he accepts the following regulations and declares that he has read and understood all requirements and regulations 1 Agreement VEGA makes the DTM Collection available as free of charge Standard version including Online help via the Internet The DTM Collection is also available as Standard version on CD The DTM Collection as Full version is only available on CD The DTM Collection as Standard version is available for free of charge use For the DTM Collection as Full version a license fee must be paid once The content of the license agreement for both versions depends on the regulations of this agreement 2 Rights of the user The DTM Collection as Standard version can be copied and used on as many computers The DTM Collection as Full version can be copied and installed on several co
24. spose of the packaging material via specialised recycling companies Storage and transport No special storage and transport conditions are necessary conditions PACTware DTM Collection 12 2011 Installation first steps 7 4 Software installation General information bio bio 4 Software installation 4 1 System requirements CPU 1 GHz oer highr 1 GB RAM 1 GB free memory Windows XP 32 Bit Vista Windows 7 32 64 Bit Internet Explorer 6 0 or higher Microsoft NET Framework 2 0 graphic resolution 1024 x 768 or higher Microsoft compatible mouse RS232 USB Ethernet interface The size of the working memory depends on the operating system and the processor as well as the installed application software and corresponds to an average value Under Windows XP 512 MB can be sufficient depending on the configuration of the operating system At least 2 GB RAM should be available with 64 Bit systems Note To install the software you will need administrator rights After the installation a Windows restart is necessary to actually complete the installation For that reason the subsequent Windows login must be carried out with the same user name the installation was performed under 4 2 Installation of PACTware and DTM Before installation all running programs should be exited 2 Insertthe CD the installation program will be started automatically If the CD does not start automatically the installation can be started by
25. ways and transfer it to the project window 3 Select the requested sensor DTM from the category Device and transfer it to the project window 4 Selectthe VEGA Ethernet DTM in the project tree and select via the right mouse key the menu item Aaditional functions Change DTM addresses Enter in the field New address the IP address the VEGAMET should get later on in real operation 5 Open now the VEGAMET and sensor DTM by double clicking and carry out the desired settings see chapter Parameter adjust ment PACTware DTM Collection 12 2011 Installation first steps 13 5 Operation VEGA Connection via VEGACOM 558 Ethernet ixi File Edit View Project Device Extras Window Help O ga alo Ge 9 00 G 3 Bas TS St Al Devices All Devices VEGA Grieshaber KG Device Ei PACTware Consortium e V Eg LAN VEGA Grieshaber KG mg Device Driver 24 Gateway 4 VEGAPULS 54 VBUS WWO Protocol 4 VEGAPULS 56 HART HART VVO Protocol VEGAPULS 56 Profibus PROFIBUS DP V1 YYO 4 VEGAPULS 56 VBUS VVO Protocol j VEGAPULS 61 FF FF H1 YVO Protocol 9j VEGAPULS 61 HART HART VVO Protocol __y j VEGAPULS 61 Profibus PROFIBUS DPJV1 WO j VEGAPULS 62 FF FF H1 VVO Protocol Device Name jj Sensor Vendor Group Type Protocol IT Show all devices 4 Update device catalog Info Add gt 39 scew szeiaN PWS Administrator

Download Pdf Manuals

image

Related Search

Related Contents

Grindmaster 650 User's Manual  INSTRUCTION MANUAL  Présentation ISG - Partie 2 - Conférence des Grandes Écoles  Manuale dell`utente Ammortizzatori posteriori 2004  File    エコリーフ環境ラベル 製品分類別基準( PCR ) 住宅用洗面化粧ユニット  FEE 2009 Illustrer une fable avec Anipaint – Mission rouge  Performance is an attitude  Frigorifero Installazioe e uso Frigorífico Instalación y uso  