Home
Controller user manual
Contents
1. Prog to continue to the minute digit Repeat the actions listed in this section e Press Prog to exit the setting mode f Press the arrow pointing down once and repeat the steps listed in sections c e to set end time 1 for the machine to stop working g Press the arrow pointing down once and press Prog to set from humidity 1 the minimal desirable humidity in the greenhouse h Press Prog to exit the setting mode i Press the arrow pointing down once and press Prog to set to temp 1 the maximal desirable temperature in the greenhouse j Press Prog to exit the setting mode k There are 2 options 1 If you want to set a second program different time frame different minimal humidity different maximal temperature go to section 1 2 below 2 If you don t want to set a second program Press Enter to return to the main menu 1 2 a Press the arrow pointing down b Press Prog to set start time 2 for the machine to start working a flickering line will appear below the hour digit c Using the arrows choose the desirable hour and press Prog to continue to the minute digit Repeat the actions listed in this section d Press Prog to exit the setting mode e Press the arrow pointing down once and repeat the steps listed in sections c e to set end time 2 for the machine to stop working f Press the arrow pointing down once and press Prog to set from
2. humidity 2 the minimal desirable humidity in the greenhouse g Press Prog to exit the setting mode h Press the arrow pointing down once and press Prog to set to temp 2 the maximal desirable temperature in the greenhouse 1 Press Prog to exit the setting mode j Press Enter to return to the main menu 2 Settings a Press Enter to enter the main menu b Using the arrow buttons go to settings menu c Press Prog to enter the menu d Password screen will appear Enter the password as described below you will then enter the settings menu e Press Prog to set the desirable variable a flickering line will appear below the digit f Using the arrow buttons choose the desirable value Press Prog to exit the setting mode Set the variables according to the following table Temp Mode 0 Stop Delay 10 Lvl Resume Delay 2 Reg Resume Delay 15 To be used according Temp Unit 0 C 1 F 0 to manufacturer s directives only Humidity Hyst 2 Temp Hyst 1 Group Act Delay 2 Group 4 Operative 1 Choose 1 if the group is activated by the machine Group 5 Operative 1 and 0 if it is not g Using the arrow buttons move to the next variable and repeat sections e f Repeat until all Variables are set h Press Enter to return to the main menu 3 System Mode Setting a Press Enter to enter the main menu b Using the arrow buttons go to s
3. move between the sub menus and press prog to enter the desirable one 1 Control From Humidity To Temp 1 Start Time End Time 2 From Humidity 2 To Temp 2 2 Settings Upon entering the settings menu you will be asked to enter a password see section G 3 System Lvl Resume Delay Reg Resume Delay Temp Unit 0 C 1 F Humidity Hyst Temp Hyst Group Act Delay Group 4 Operative Group 5 Operative Mode 4 System Unit Number Baud Rate 5 History of events Reg Stop Thermo Stop Reset To reset the data you will be asked to enter a password see section G 6 Test Low Level High Level Regenerator Control Thermostat Bypass 1 2 7 Calibration This function is to be changed by the manufacturer only Press Enter to return to the main menu Press Enter again to return to the main screen Controller settings Primary settings Lift the main switch All the lights will turn on and the version number will appear on the screen Then the lights will turn off and the main screen will appear 1 Control Setting the machines operating program 1 1 a Press Enter to enter the main menu b Press Prog to enter the control menu c Press Prog to set start time 1 for the machine to start working a flickering line will appear below the hour digit d Using the arrows choose the desirable hour and press
4. Controller user manual Contents page Controller s setup 3 The program map 4 Controller settings 8 Controller set up Front board door 1 Leds indicating whether the application is on or off Light is on application is on light 1s off application is off 1 Main desiccant pump 2 Main blowers 3 Regenerator including minor desiccant pump water pump and blower 4 optional electrical tap dumper 5 Heater hot water pump Bypass Machine is working without the controller in which case all other lights are off Warning The door is locked by buckles on its left side They should be opened and closed carefully while administering counter support to the fuse box 2 Prog Button is used to enter the sub menus from the main menu and to change the variables press once to enter edit mode a flickering line will appear below the variable to be edited press again to move to the next variable or to exit the edit mode 3 Arrow buttons are used to navigate within the menus and to change the variables values while in edit mode 4 Enter button is used to enter the main menu from the main screen and to exit the menus Bypass switch Left Panel Electrical switches 1 Controller bypass switch has the shape of a lock has 2 states a On machine is working in controller bypass mode b Off machine is working in normal mode 2 Electrical switch box In
5. relay activates a group as described in controller setup ON One can turn the group on or off by pressing Prog moving to the desirable ON state using the arrow buttons and pressing Prog again to choose ON After 5 minutes the relay will return to its previous state NOTE The relays activated within the test menu will automatically return to the state which was previously set within the control menu immediately after exiting the Test mode e Press Enter to return to the main menu 7 Calibration This function is to be changed by the manufacturer only Entering a password In certain cases you will be asked to enter a password The password is 1234 a Press Prog A flickering line will appear beneath the digit 0 b Using the arrow buttons move to the digit 1 c Press Prog again to move to the next digit d Using the arrow buttons move to the digit 2 e Continue accordingly until you have entered the whole password 11
6. set using the arrow buttons and press Prog Enter the password as described in section G g Press Enter to return to the main menu 6 Test checking the machines functioning a Press Enter to enter the main menu b Using the arrow buttons go to history menu c Press Prog to enter the menu d Review the sections to see if they are compatible with the machine s status according to the explanations in the following table Temp 24 0 459 Displays the current temperature in the greenhouse Humidity 44 405 Displays the current humidity in the greenhouse Input Low Level ON Displays the desiccant s status ON normal level OFF level is too low see problem solving Input High Level ON Displays the desiccant s status ON normal level OFF level is too high see 10 Input Regenerator Input Control Input Thermostat Input Bypass Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 problem solving ON Displays the desiccant s status ON normal concentration OFF concentration 1s too high see problem solving ON Displays distal activation by computer ON normal OFF was turned off by the computer or electrical bridge is disconnected ON Displays the hot water status ON desirable temperature OFF temperature is too low OFF Displays activation by a controller bypass ON activated by controller bypass OFF normal activation by controller ON ON _ Each
7. side the box there are 3 switches a Main disconnects the machine from electricity b Fl supplies current to groups 1 and 2 c F2 supplies current to groups 3 4 and 5 Bottom panel Contains the entrance points of the electrical cables from the different parts of the machine and the corresponding sensors according to the electrical scheme see attached drawing Power electric diagram electricity and control box Program map Main screen Current Temperature Current Humidity Current Time Current State Normal Auto Normal Manual Not Operational Low Limit High Limit Regenerator Limit Temperature Failure Humidity Failure Control Input Bypass Mode Thermostat Machine is working in automatic mode Machine is working in manual mode Machine is not working Desiccant level is too low Desiccant level is too high Desiccant concentration is too high Temperature sensor is not connected not working Humidity sensor is not connected not working Machine is activated by computer Machine is activated by controller bypass Hot water temperature is too low Fast approach to view target humidity and temperature values While at the main screen press the a button The following screen will appear for 5 seconds While at the main screen press Enter and the main menu will appear Settings System Mode System History Test Calibration Using the arrow buttons
8. ystem mode menu c Press Prog to enter the menu d Press Prog for adjustment of the work mode A flickering line will appear below the variable being processed e Using the arrow buttons choose the desirable option and press Prog to exit the setting mode f Press Enter to return to the main menu 4 System Adjustment of the current time a Press Enter to enter the main menu b Using the arrow buttons go to system menu c Press Prog to enter the menu d Press Prog to adjust the hour a flickering line will appear below the hour digit e Using the arrow buttons choose the desirable hour press Prog to pass to the minute digit and repeat the actions in this section f Press Enter to return to the main menu 5 History a Press Enter to enter the main menu b Using the arrow buttons go to history menu c Press Prog to enter the menu d Using the arrow buttons move between the different categories e Check the number of stops which occurred If there were stops which happened due to a too low or too high level of desiccant see management options under problem solving in the user manual The same applies for cases when the regenerator has stopped working more than 3 times a night If the machine was stopped by the thermostat check whether the heater supplies the appropriate heat f In order to reset the data navigate to Re