GJD505 & GJD509 USER GUIDE

image

Contents

1. field width is defined by teach in RESTORING TO FACTORY VALUES teach in SAVING AN ACCESS CODE The access code is recommended for sensors installed close to each other 9 0 0 910 910 910 9 O DELETING AN ACCESS CODE al 0 9 0 9 0 930 9 v Oss O Enter the existing code X NUMBER OF FLASHES VALUE OF THE PARAMETER 9 X TROUBLESHOOTING No blue LED There is no power The polarity of the power supply is inverted All LEDs have been de activated by remote control Only the blue LED is on The detection LED remains green The detection field is too small or deactivated The object size is too small The detection LED remains red The orange LED is flashing and the detection LEDs are red No background reference point is found The sensor is masked The orange LED is on 30 minutes after last use of the remote control the sensor locks the access to the remote control session The sensor does not respond to the remote control The batteries in the remote control are not installed properly or dead The remote control is badly pointed A reflective object is in close proximity to the sensor The sensor does not unlock 10 Ep Check cable and connexion EJ Check the polarity of the power supply EJ Activate the LEDs by remote control EE Check wiring The RED and BLUE cable have to be connected to the test input or
2. E Max detection range GJD509 9 9 m x 9 9 m GJD505 5 0 m x 5 0 m Remission factor gt 2 Angular resolution OSS lo Min detected object size typ in proportion to object distance GJD509 2 1 m 3m s5cn eam 7cne 10m GJD505 21cm 3 mMm 35 cin San Testbody 700 mm x 300 mm x 200 mm testbody A according to EN 12445 Emission characteristics IR laser wavelength 905 nm max output pulse power 75 W CLASS 1 Red visible laser wavelength 650 nm max output CW power 3 mW CLASS 3R Supply voltage 10 35 V DC sensor side Power consumption lt 5W Peak current at power on 1 8 A max 80 ms 35 V Cable length 10m Response time typ 20 ms max 80 ms output activation delay Output Max switching voltage Max switching current Switching time Output resistance Voltage drop on output Leakage current 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 MA resistive ty D MS tog39 MS typ 300 lt 0 7 V 20 mA lt 10 pA Input Max contact voltage Voltage threshold 2 optocouplers galvanic isolated polarity free 30 V DC over voltage protected Log ale S18 VDC Log Eeo VDC Response time monitoring input lt 5 ms LED signal 1 blue LED power on status 1 orange LED error status 2 bi coloured LEDs detection output status green no detection red detection Dimensions 1
3. of the 2 sensors must be max 20 cm FJ MOUNTING SIDE Select the corresponding mounting side The sensor learns its environment and automatically determines the detection field s Both RED LEDs flash slowly and the 3 visible laser beams automatically light up during 30 seconds looo left right left centre WITH BACKGROUND WITHOUT BACKGROUND The sensor memorizes the floor as reference point and signals a fault when its orientation is changed No reference point no signal EJ SAFETY FIELD DIMENSIONS WIDTH MIN MAX MIN MAX no field 0 5m 99m no field oim 06 00 06 60 0 5 m 9 9 m oim 5 0m m HEIGHT EXAMPLE g GOO iora field width of 6 2 m TEACH IN Launch a teach in after changing the sensor position or when new objects are added to or changed in the detection zone Wait for the sensor to learn its environment or lock it by remote control During teach in the sensor learns its surroundings and adapts the detection field shape to these Objects in the detection field will be cut out max 305 6 REMOTE CONTROL ADJUSTMENTS OPTIONAL DETECTION CURTAINS ID O 0 0O Q EX C1 C2 active on optional field only CURTAIN C1 C2 C3 C4 C3 C4 active on safety field only deactivate curtain on both fields C1 active on both fields C2 C3 active on safety field only C4 deactivated activate curtain only on optional field activate curtain only on safe
4. teach in each time the sensor position is changed or new objects are added to or changed in the detection zone ATTENTION This PB teach in is different from the safety field teach in When the red LED flashes very slowly after 3 seconds hold your hand in front of the sticker to learn the detection zone The green LED flashes 3x to confirm the selection When the red LED flashes again learn a second max 2 detection zone or wait until the LED switches to green OR SAFETY DURING OPENING OF INDUSTRIAL DOORS Configure a second detection field to secure the door during opening LO After setting the mounting side the safety and the optional field will have the same dimensions 2 Adjust the size of the field by remote control 3 Change the output redirection if needed WIDTH f amp 0000 00 00 00 00 A 0 5 m 9 9 m U 0 5 m HEIGHT Hak ia 00 06 00 00 06 60 A no field 0 5 m 9 9 m no field 0 5 m HOW TO USE THE REMOTE CONTROL e o a DPIDO 0 0 920 920 940 9 q gt q gt u After unlocking the red If the red LED flashes quickly after unlocking you To end an adjustment session LED flashes and the sensor need to enter an access code from 1 to 4 digits always lock the sensor can be adjusted by remote control ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE _0000 2 2a_ 6 EE EDGED a Turn LED s OFF Turn LED s ON D field width 4 2 m 4 IA r r 4
5. 25 mm D x 93 mm W x 70 mm H mounting bracket 14 mm Material PC ASA Colour black or white Mounting angles on bracket AUS 18 Alls Rotation angles on bracket 5 to 5 lockable Tilt angles on bracket 3 to 3 Protection degree IP65 Temperature range 30 C to 60 C if powered 10 C to 60 C unpowered Humidity 0 95 non condensing Vibrations lt 20 Pollution on front screens max 30 homogenous Expected lifetime 20 years Norm conformity 2006 95 EC LVD 2002 95 EC RoHS 2004 108 EC EMC 2006 42 EC MD EN 12453 2000 chapter 5 1 1 6 chapter 5 5 1 Safety device E EN 12978 2009 EN ISO 13849 1 2008 PI d CAT2 EN 60529 2001 IEC 60825 1 2007 EN 60950 1 2005 EN 61000 6 2 2005 EN 61000 6 3 2006 IEC 61496 1 2009 EN 61496 3 2008 ESPE Type 2 EN 62061 2005 SIL 2 DIN 18650 1 2010 Chapter 5 7 4 Specifications are subject to changes without prior notice All values measured in specific conditions NOTES GJD Manufacturing Limited Unit 2 Birch Business Park Whittle Lane Heywood Lancashire United Kingdom OL10 2SX Tel 44 0 1706 363 998 Fax 44 0 1706 363 991 e info gjd co uk DETECT amp SECURE
6. CJ 0 5 cr E ID e Be he ed R CJIDS05 amp OJIDS09 CJDS05 amp OJIDSOSD LASER SCANNERS FOR INDUSTRIAL DOORS amp OTHER SAFETY AND PROTECTION APPLICATIONS GJD509 max detection range of 10 mx 10 m GJD505 max detection range of 5 0 m x 5 0 m SAFETY The device contains IR and visible laser diodes IR laser wavelength 905nm max output pulse power 75W Class 1 according to IEC 60825 1 Visible laser wavelength 650nm max output CW power 3mW Class 3R according to IEC 60825 1 The visible laser beams are inactive during normal functioning The installer can activate the visible lasers if needed Do not look into the laser The warranty is void if Only trained and qualified Test the good functioning emitter or the visible red unauthorized repairs are personnel may install and of the installation before laser beams made or attempted by adjust the sensor leaving the premises unauthorized personnel When used in conjunction with industrial doors the manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with the applicable national and international regulations and standards on door safety and if applicable the machinery directive 2006 42 EC Other use of the device is outside the permitted purpose and cannot be guaranteed by the manufacturer The manufacturer cannot be held responsible for incorrect installations o
7. he Pass the cable 10 cm though template to position the sensor mounting template Make a hole the cable opening If drilling an correctly The grey area indicates for the cable if possible opening is not possible use the the detection range cable conduits on the back side of the bracket Position the bracket and fasten Open the protection cover plug Close the protection cover and the 4 screws firmly in order to the connector and position the fasten it firmly avoid vibrations cable in the slit Position the housing on the Turn the sensor until the two bracket triangles are face to face GREEN POWER SUPPLY BROWN POWER SUPPLY WHITE RELAY 1 OPTIONAL FIELD YELLOW a RELAY 2 SAFETY FIELD VIOLET j RED Test T ENABLE LED S BLUE test CONNECT RED TO AND BLUE TO WITH POWER SUPPLY CONNECTORS WHITE RED NOT USED WHITE BLUE E POSITIONING Unlock the sensor and activate the visible laser beams The visible laser beams indicate approximately the postion of curtain C1 and limit the angle of the detection field The visible laser beams stay activated for 15 minutes or can be turned off the same way they were activated Adjust the lateral position of Adjust the tilt angle of the Lock the position of the the detection field detection field with the hex mounting bracket to avoid key malfunctioning in case of extreme vibrations AUTION The distance between the inner curtains
8. r inappropriate adjustments of the sensor INSTALLATION AND MAINTENANCE Avoid extreme Do not cover Avoid moving objects Avoid the presence Avoid condensation vibrations the front screens and light sources in of smoke and fog in the detection field the detection field Avoid exposure to Avoid direct exposure Do not use aggressive Wipe the front Keep the sensor sudden and extreme to high pressure products to clean screens regularly permanently powered temperature changes cleaning the front screens with a clean and in environments where damp cloth the temperature can descend below 10 C DESCRIPTION 1 laser sweep emission 6 protection cover 2 laser sweep reception 7 visible laser beam 3 3 LED signal 4 8 notch for tilt angle adjustment 2 4 screw for position lock 2 9 adjustable bracket 5 connector 10 cable conduit 4 LED SIGNAL 1 Detection LED relay 1 optional field 2 Detection LED relay 2 safety field TY LED flashes quickly 3 Error LED 12 3 4 4 Power LED LED flashes DETECTION LEDs ERROR LED POWER LED J detection error power J LED flashes slowly no detection no error no power C E osor SYMBOLS According according to to Caution Remote control Possible Factory EN ISO 13849 1 2008 Laser radiation sequence remote control values PI d CAT2 adjustments KJ MOUNTING Use the adhesive mounting Drill 4 holes as indicated on t
9. the power supply 1 Check the size of the fields 2 Launch a teach in EJ Decrease the min object size KI Step out of the field and or remove the any object s from the field EF Activate the 3 red beams and check if the position of the sensor is correct If not adjust the hex screws Zi Verify the field size EF Launch a teach in MD Check the position of the sensor EJ Check the mounting side setting If there is no background set the mounting side to value 3 to 5 EJ Launch a new teach in EJ Verify and clean the front screens with a damp cloth EF Check the power supply voltage EF Verify the outside temperature where the sensor is installed Eventually protect the sensor from sunlight using a cover EF Wait a few seconds If the LED remains ON reset the power supply If the LED turns on again replace the sensor EJ Cut and restore power supply The remote control session is accessible again during 30 minutes in Verify or replace the batteries EJ Point the remote control towards the sensor but with a slight angle The RC should not be pointed in a right angle in front of the sensor EJ Avoid highly reflective material in proximity to the sensor EF Cut and restore power supply No code is required to unlock during the first minute after powering TECHNICAL SPECIFICATIONS Technology laser scanner time of flight measurement Detection mode motion and presence EN 12453 Typ
10. ty field 0 0 0 6 O00900 activate curtain on both fields All curtains active on both fields The distances between the curtains depend on the mounting height and side When mounted on the left the distance between the first and the last curtain is approximately 10 cm for every meter mounting height Example at 5 m the distance is 50 cm UNCOVERED ZONE O 0 e e 0 10 15 20 25 cm CAT 2 a Increase in case of snow dead leaves etc IMMUNITY FILTER 0000 O QOQ OQO oi outdoor outdoor low med high Increased immunity to rain snow fog Increased sensitive detection of black objects sr 00000 off 10 15 20 cm OUTPUT ACTIVATION DELAY 0 9 O 000606609600 approximate values off 100 200 300 400 500 600 700 800 900 ms The outputs are triggered after a constant detection time of x ms ex value 3 300 ms DETECTION FIELD ui REDIRECTION optional or safety safety OUTPUT CONFIGURATION 0000 ee R1 A NOL P NCI P Nc A no 2 lt tve P passive R1 R2 R2 P NC A NO P NC A NO NO normally open NC normally closed _ FACTORY VALUES Rx RELAY OUTPUT 7 OPTIONAL FIELD CONFIGURATIONS VIRTUAL PUSH BUTTON FOR INDUSTRIAL DOORS Install 1 or 2 virtual push buttons as activation zone s to open the door manually Fag Apply the vitual push button sticker s within the opening field 2 Launch a PB teach in to configure the detection zone s Launch a new PB

Download Pdf Manuals

image

Related Search

Related Contents

Aiphone CCS-1A User's Manual  descargar - Oenobrands.com  おじずる省エネルギー対策に最適な提案  SV-iP5A User Manual  Stampa documenti - Agenzia provinciale per le risorse idriche e l  Hampton Bay IMS1691L Instructions / Assembly  Owner`s Manual Mode d`emploi  Fluke Corporation Fluke 125 Industrial ScopeMeter Manual  シリーズ最強新登場!!    