Home
InstallatIon & User GUIde thermostatIc Bar ValVe
Contents
1. MIRA ATOM ERD THERMOSTATIC BAR VALVE INSTALLATION amp USER GUIDE These instructions must be left with the user CONTENTS INTRODUCTION Introduction 2 Guarantee 2 Recommended Usage 2 Patents and Design Registration 3 Safety Warnings 3 Pack Contents 4 Specifications 5 Pressures 5 Temperatures 5 Thermostatic Shut down 5 Connections 5 Dimensions 5 Installation 6 Suitable Plumbing Systems 6 General 6 Solid Wall Installation 7 Stud Partition Laminated Panel or Unfixed Rear entry Pipework Installation 8 Divertor and Rigid Riser Assembly Installation 10 Commissioning 12 Maximum Temperature Setting 12 Operation 12 Adjusting the Temperature 12 Adjusting the Flow 12 Operating the Divertor 12 User Maintenance 13 Fault Diagnosis 13 Spare Parts 14 Accessories 16 Notes 17 Customer Service Back Page If you experience any difficulty with the installation or operation of your new thermostatic mixer please refer to Fault Diagnosis before contacting Kohler Mira Ltd Our contact details can be found on the back cover of this guide Thank you for purchasing a quality Mira product To enjoy the full potential of your new product please take time to read this guide thoroughly having done so keep it handy for future reference The Mira Atom thermostatic bar valve is a thermostatic shower control designed for wall mount installations The thermostati
2. O 1660 161 Deluge Head 1660 163 Rigid Riser Rail 1 Piece 1660 289 u Rigid Riser Rail 2 Piece 1663 190 Showerhead 1603 137 Flexible Hose 1660 172 Clamp Bracket 1660 178 Compression Nut amp Olive N 1660 165 Divertor Assembly 1595 073 Hose Retaining Ring 15 ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services our contact details can be found on the back cover of this guide or from approved stockists or merchants Eco Showerhead White 2 1668 001 Chrome 2 1668 002 The Eco shower head gives you an invigorating shower but reduces water consumption and heating costs Everclear Showerhead White 2 1616 030 Chrome 2 1616 031 Mira s new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up Wall Mounted Soap Dish White 1 1540 278 Chrome 1 1540 279 Wall mounted for use anywhere in or outside the showering area Bar Valve Fixing Kit Chrome 2 1663 017 A fixing kit designed to make the installation of bar valves easier and more secure than traditional Z connectors Shower Seat White 2 1536 128 White Chrome 2 1536 129 For use in or out ofthe showering area Folds up when not in use Maximum User Weight 127 kg 20 stone Note Must be installed onto a solid wall Premium Shower Seat White Chrome 2 1731 001 Grey Chrome 2 1731 002
3. pipework in the wall The offset connectors must protrude between 35 and 40 mm from the finished wall Note Connections are Hot Left Cold Right This is very important as this product does not allow for reversed inlets 35 40 mm 2 BSP Female Connection a Offset 2 o Connector Sto 20 Oo AOS So sO es So ao Tile Apply Silicone Sealant to seal Support Pipework Wall hole in wall Bracket Spirit Level Tighten the offset connectors using a spanner on the spanner flats Make sure that the connectors are level and set at the correct distance apart using the bar valve as a guide to spacing Concealing Plates Screw the concealing plates onto the offset connectors until they come into contact with the wall Caution Make sure that the supply pipework is flushed before installing the Bar Valve Assemble the bar valve with a sealing washer filter in each inlet and attach to the offset connectors Note Connections are Hot Left Cold Right Sealing Washer Filter Tighten the connections using a suitable spanner Install the divertor and rigid riser assembly go to section Divertor and Rigid Riser Assembly Installation Stud Partition Laminated Panel or Unfixed Rear entry Pipework Installation For all installations using the Wall Mounting Bracket 1 Install the pipework make sure that it is set at the correct distance apart 150 24
4. Stylish slim line and robust shower seat for use in or outside ofthe shower area Folds up when not in use Maximum User Weight 150 kg 23 5 stone Note Must be installed onto a solid wall 16 Logic Showerhead Holder White 2 1605 149 White Chrome 2 1605 150 An alternative to the traditional slide bar Often a useful addition when positioned for the smaller members of the family Mira Bar Valve Fixing Elbows Chrome 2 1712 002 Designed to allow any bar valve with 3 4 female connections to be easily installed onto exposed rising or falling inlet supply pipework NOTES NOTES NOTES CUSTOMER SERVICE Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase To activate this guarantee please return your completed registration card visit our website or free phone 0800 0731248 within 30 days of purchase UK only Within the guarantee period we will resolve defects in materials or workmanship free of charge by repairing or replacing parts or product as we may choose This guarantee is in addition to your statutory rights and is subject to the following conditions e The product must be installed and maintained in accordance with the instructions given in this user guide Servicing must only be undertaken by us or our appointed representative Note if a service visit is required the product must be ful
5. mm and solidly fixed 150 24 mm hi Pipe Centres in Wall g 27 mm 2 Screw the mounting brackets onto the offset connectors The offset connectors must protrude between 35 and 40 mm from the finished wall 3 The mounting bracket must extend in the same direction as the offset of the offset connector The angle between the offset connector and the mounting bracket must be less than 45 otherwise the mounting bracket will not fit under the concealing plate Wall Mounting Bracket Offset Connector 4 The mounting bracket boss should protrude to the rear facing the wall 5 Apply suitable thread sealant not supplied and attach the offset connectors to the pipework in the wall Note Connections are Hot Left Cold Right This is very important as this product does not allow for reversed inlets gt 10 mm Y BSP Female Connection Offset Boss Connector Pipework Wall Mounting Bracket Wall Apply Silicone an Sealant to seal racket hole in wall Spirit Level Tighten the offset connectors using a spanner on the spanner flats Make sure that the connectors are level and set at the correct distance apart using the bar valve as a guide to spacing Fix the mounting bracket to the wall through the small hole using the appropriate wall fixings for the type of wall not supplied Caution Take care not to drill though any concealed pipework Screw the concealing plates on
6. the securing bracket with a 6 mm drill and insert the wall plugs supplied For other types of wall structure alternative fixings may be required not supplied Secure the securing bracket to the wall using the screws supplied Securing Bracket N Fixing Screws Rigid Riser Wall Plugs Overhead Pipe w Pin A Securing Bracket Cover KOJ N Rigid Riser Rail Spirit Level piri eve Slide the clamp bracket hose retaining ring compression nut and olive onto the rigid riser rail and locate into the divertor outlet Make sure that the securing bracket cover is fitted onto the rigid riser overhead pipe then fix the pipe to the securing bracket with the pin Screw the securing bracket cover over the securing bracket Tighten the compression nut using a suitable spanner Note Hold the divertor in position whilst tightening the compression nut Fit the 12 L Min flow regulator into the hose then screw the hose onto the outlet of the divertor making sure that the hose seal is fitted 10 Pass the flexible hose through the hose retaining ring and screw the remaining end of the hose onto the showerhead making sure that the hose seal is fitted 11 Place the showerhead in the clamp bracket 18 Make sure that the hose washer is fitted and screw the deluge head onto the rigid riser arm 12 Turn on the hot and cold water supplies and chec
7. al to see if simple home maintenance is required If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy excludes Eire Ring 01922 471763 for more details Mira is a registered trade mark of Kohler Mira Limited The company reserves the right to alter product specifications without notice 1098814 W2 F HO4B 1663 Helpdesk Service Our dedicated Customer Services Team is comprehensively trained and can offer help and advice spare parts accessories or a service visit We willneed you to have your model name or number power rating if applicable and date of purchase As part of our quality and training programme calls may be recorded or monitored Mira Showers Website www mirashowers co uk From our website you can register your guarantee download additional user guides diagnose faults purchase our full range of accessories and popular spares refer to our FAQ s and request a service visit Spares and Accessories We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product s expected life Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days Items purchased from us are guaranteed for 12 months from date of purchase For safety reasons
8. c bar valve has two knobs one knob controls the flow and the other knob controls the temperature The Mira Atom ERD is supplied with a deluge head rigid riser and divertor assembly in addition to a single mode showerhead and shower fittings kit The thermostatic bar valve incorporates a wax capsule temperature sensing unit which provides an almost immediate response to changes in pressures or temperature of the incoming water supplies to maintain the selected temperature An adjustable maximum temperature stop is provided which limits the temperature to a safe level Inlet filters are fitted to protect the thermostatic cartridge Guarantee For domestic installations Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of three years from the date of purchase shower fittings for one year For non domestic installations Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of one year from the date of purchase For terms and conditions refer to the back cover of this guide Recommended Usage Application Mene with Fittings Domestic v Light Commercial v Heavy Commercial x Healthcare x Patents and Design Registration Patents GB 2 407 138 Design Registration 000793401 0001 0004 SAFETY WARNINGS The function of a thermostatic mixing valve is to deliver water consistently ata safe temperature In k
9. d legs should be kept to a minimum 6 Decide on a suitable position for the mixer The position of the mixer and the shower fittings must provide a minimum gap of 25 mm between the spill over level of the shower tray bath and the showerhead refer to illustration This is to prevent back siphonage Note Only use shower fittings recommended by the manufacturer or supplier 7 All pipework must be checked for leaks before the product installation is completed The product should be pressurised amp the inlet amp outlet connections inspected 8 DO NOT overtighten grubscrews as product damage may occur Use hexagonal key provided and hand tighten only do not use powertools Q jim 25 mm Spill Over BD ee Solid Wall Installation For solid wall installations the thermostatic bar valve can be supported by the pipework provided that it is securely fixed to the wall Alternatively for unfixed rear entry pipework the wall mounting bracket can be used For installation onto a stud partition laminated panel or onto unfixed rear entry pipework using the wall mounting bracket refer to section Stud Partition Laminated Panel or Unfixed Rear entry Pipework Installation 1 Install the pipework making sure that it is set at the correct distance apart 150 24 mm and solidly fixed 2 Apply suitable thread sealant not supplied and attach the offset connectors to the
10. eeping with every other mechanism it cannot be considered as functionally infallible and as such cannot totally replace a supervisor s vigilance where that is necessary Provided it is installed commissioned operated and maintained within manufacturers recommendations the risk of failure if not eliminated is reduced to the minimum achievable Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance provided 1 They are installed commissioned operated and maintained in accordance with the manufacturer s recommendations 2 Periodic attention is given when necessary to maintain the product in good functional order Caution 1 Read all of these instructions 2 Retain this guide for later use 3 Pass on this guide in the event of change of ownership of the installation site 4 Follow all warnings cautions and instructions contained in this guide 5 Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering Particular consideration should be given to the young the elderly the infirm or anyone inexperienced in the correct operation of the controls 6 Rapid Excessive movement of the flow and or temperature control levers may result in momentary unstable blend temperatures 7 Care is required when adjusting flow or temperature make sure that the temperature has stabilised 8 When this product ha
11. fed from a cold water cistern usually fitted in the loft space and a hot water cylinder usually fitted in the airing cupboard providing nominally equal pressures Gas Heated System The thermostatic mixer can be installed with a combination boiler Unvented Mains Pressure System The thermostatic mixer can be installed with an unvented stored hot water system Mains Pressurised Instantaneous Hot Water System The thermostatic mixer can be installed with systems of this type with balanced pressures Pumped System The thermostatic mixer can be installed with an inlet pump twin impeller The pump must be installed on the floor next to the hot water cylinder General Installation must be carried out in accordance with these instructions and must be conducted by designated qualified and competent personnel The installation must comply with the Water Supply Regulations 1999 Water Fittings or any particular regulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to the information given in section Specifications 1 The mixer must not be installed in an area where it may freeze 2 For stud partitions alternative fixings may be required 3 Isolating valves must be installed close to the mixer for ease of maintenance 4 Pipework must be rigidly supported and avoid any strain on the connections 5 Pipework dea
12. k for leaks 13 Before using the shower refer to section Commissioning Securing Bracket Cover Clamp Bracket Hose Retaining Ring Compression Nut mM Kop XA 12 L Min Flow Hose Regulator COMMISSIONING OPERATION Maximum Temperature Setting Before using the shower the maximum temperature must be checked to make sure that it is at a safe level It has been preset to a safe showering temperature under ideal conditions at the factory appropriate for most systems However site conditions and personal preference may make it necessary to reset this temperature Note Make sure thatthe hot water temperature is at least 55 C and that there is sufficient supply Caution Before testing the mixer make sure that the hot and cold water is flowing correctly by exercising the temperature selector knob between the cold and hot stops 1 Turn the temperature selector knob to position 7 and test that the temperature of the water from the shower outlet is hot enough 2 If not depress the override button and carefully rotate towards position 9 Ifthe water temperature is still not hot enough complete the following procedure 3 Rotate the temperature selector knob back to position 7 4 Using a suitable screwdriver carefully prise off the concealing cap and unscrew the fixing screw 5 Pull off the temperature selector knob without disturbing the stop assembly Tempe
13. lly equal pressures Recommended Hot Supply 60 C to 65 C Note The mixing valve can operate at temperatures up to 85 C for short periods without damage However for safety reasons itis recommended thatthe maximum hot water temperature is limited to 65 C Minimum Differential between Hot Supply and Outlet Temperature 10 C Cold Water Range 5 C 25 C Thermostatic Shut down For safety the thermostat will shut off the hot supply within 2 Seconds if the cold supply fails achieved only if the hot supply temperature is greater than 10 C above the set blend temperature Connections Hot Left side nearest flow control BSP Male Cold Right side nearest temperature control 2 BSP Male Outlet top 15 mm compression from divertor Note This product does not allow for reversed inlets and will deliver unstable temperatures if fitted incorrectly Offset connector inlet centres are 150 mm 24 mm Y BSP Connection to Bar Valve Connection to Pipework Dimensions rO A 1000 59 gt x 70 Va Le 100 lt 2 ep 150 24 100 Min to Wal yo Av gt 100 Min to Wall 340 80 I gt 145 190 Dimensions in mm INSTALLATION Suitable Plumbing Systems Gravity Fed The thermostatic mixer must be
14. ly installed and connected to services Repair under this guarantee does not extend the original expiry date The guarantee on any replacement parts or product ends at the original expiry date e For shower fittings or consumable items we reserve the right to supply replacement parts only The guarantee does not cover e Call out charges for non product faults such as damage or performance issues arising from incorrect installation improper use lack of maintenance build up of limescale frost damage corrosion system debris or blocked filters or where no fault has been found with the product e Water or electrical supply waste and isolation issues Compensation for loss of use of the product or consequential loss of any kind e Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative e Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes What to do if something goes wrong If your product does not function correctly when you first use it contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual Should this not resolve the issue contact our Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call If the performance of your product declines check in this manu
15. rature Selector Knob Fixing Screw 6 Replace the temperature selector knob so that the 6 mark is in line with the stop assembly 7 Rotate the temperature selector knob to position 7 wait for the water to stabilise and test that the temperature of the water from the shower outlet is hot enough Ifthe water temperature is still not hot enough repeat the procedure until a maximum safe temperature is achieved at position 9 8 Refit and tighten the fixing screw refit the concealing cap Adjusting the Temperature The temperature is controlled by rotating the temperature knob For safety reasons the temperature is limited by an override stop To obtain a higher temperature press the override button on the temperature knob and continue to rotate Adjusting the Flow The flow is controlled by rotating the flow knob Operating the Divertor The flow is switched between the deluge head the showerhead and both together by rotating the divertor knob USER MAINTENANCE If you require a Mira trained service engineer or agent refer to section Customer Services Fault Diagnosis Symptom Only hot or cold water from the mixer outlet Outlet temperature too hot too cold Cause Rectification Inlets reversed hot supply to cold supply Rework inlet pipework No hot or cold water reaching the mixer Check the filters for any blockage Installation conditions outside operating parame
16. re located in the thermostatic bar valve body and are accessible through the inlet connectors Caution Make sure that the non return valves are installed correctly to prevent crossflow or malfunction of the valve 1 With the water supplies turned off and the thermostatic bar valve removed remove the sealing washer filter 2 Unscrew the non return valve housing using a 12 mm hexagonal wrench Note The non return valve housing has a Left Hand Thread turn clockwise to unscrew 3 Carefully remove the non return valve and clean any debris 4 Onre assembly make sure that the non return valve is fitted the correct way round with the arrow indicating the flow pointing towards the valve Non Return Valve Inlet Connector Non Return Valve Housing Sealing Washer Filter SPARE PARTS Note All spare parts are supplied individually unless stated otherwise 456 29 Wall Mounting Bracket x2 1663 113 Non Return Valve and Filter Washers x2 Ce Ye 1630 049 Qa Or Filter Washer 0 gt ON 9 1663 170 Outlet Connector 1630 041 Offset Connector Kit x2 O y 1663 311 Long Inlet x2 1663 117 Flow Cartridge 1663 118 Flow Knob Assembly 1663 116 Temperature Knob Assembly 1663 115 Temperature Stop Assembly 1663 114 Thermostatic Cartridge 14 1663 289 Rigid Riser Overhead Pipe 2 1660 162 Fixing Pack
17. s reached the end of its serviceable life it should be disposed of ina safe manner in accordance with current local authority recycling or waste disposal policy PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that all ofthe parts are included SS O Z7 U 2 x Wall Plugs 2x Fixing Screws 1x Securing Bracket 1x Securing Bracket Cover L 1xPin U 1 x Rigid Riser Overhead Pipe U 1 x Rigid Riser Rail supplied in 2 parts Chix Deluge Head amp Seal 09 U 2 x Washers Filters 2x Concealing Plates n ew U 1 x Divertor Assembly inc Nut Olive amp M4 x 5 mm Grubscrew U 1 x EV Fittings Kit U 1x2 mm Hexagonal Key U 1x Flow Regulator 12 L Min 2 2 x Inlet Connectors Documentation U 1 x Guarantee Registration Document SPECIFICATIONS Pressures Max Static Pressure 10 Bar Max Maintained Pressure 5 Bar Min Maintained Pressure Gas Water Heater 1 0 Bar for optimum performance supplies should be nominally equal Min Maintained Pressure Gravity System 0 1 Bar 0 1 bar 1 Metre head from cold tank base to showerhead outlet Note 0 25 Bar when running both outlets Temperatures Close temperature control is provided between 20 C and 50 C Optimum Thermostatic Control Range 35 C to 45 C achieved with supplies of 15 C cold 65 C hot and nomina
18. spares exposed to mains voltages should only be fitted by competent persons Returns items can be returned within one month of date of purchase providing that they are in good condition and the packaging is unopened Please obtain authorisation from our Customer Services Team before return We reserve the right to apply a 15 restocking charge Service Repairs We have a nationwide team of Service Technicians who can carry out all service or repair work to your product within the guarantee period and beyond You have the assurance ofa fully trained Mira Technician genuine Mira spare parts and a 12 month guarantee on any chargeable work done Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards To Contact Us UK Telephone 0844 571 5000 Mon to Fri 8 00 am 5 30 pm Sat 8 30 am 3 30 pm E mail technical mirashowers com Fax 01242 282595 By Post Mira Customer Services Dept Cromwell Road Cheltenham Gloucestershire GL52 5EP Eire Telephone 01 459 1344 Mon to Fri 9 00 am 5 00 pm E mail sales modernplant ie Fax Dublin 01 459 2329 By Post Modern Plant Ltd Dublin Otter House Naas Road Clondalkin Dublin 22 m ra A SHOWERS FM 14648 O Kohler Mira Limited April 2010
19. ters refer to sections Specifications and Commissioning Symptom Fluctuating or reduced flow rate Cause Rectification Check the showerhead hose and filters for any blockage Make sure that the maintained inlet pressures are nominally balanced and sufficient refer to section Specifications Make sure that the inlet temperature differentials are sufficient refer to section Specifications Flow regulator fitted incorrectly Air lock or partial blockage in the pipework Symptom Water leaking from showerhead Cause Rectification Normal for a short period after shut off Check that the pressures are not in excess of the specifications for the product Cartridge inlet seals damaged renew Renew the thermostatic cartridge Filters The sealing washers filters are located in the inlet connector Clean or renew as necessary 13 Lubricants Silicone based lubricants must only be used on the rubber seals Caution Oil based or other lubricant types may cause rapid deterioration of seals Cleaning The chrome plated parts should be cleaned using a mild washing up detergent or soap solution rinsed and then wiped dry with a soft cloth Warning Many household cleaners contain abrasive and chemical substances and should not be used for cleaning plated or plastic fittings Do not use descalents on this product Maintaining the Non Return Valves The non return valves a
20. to the offset connectors until they come into contact with the wall Cold 150 24 mm Concealing Plates Spanner Flats Caution Make sure that the supply pipework is flushed before installing the Bar Valve Assemble the bar valve with a sealing washer filter in each inlet and attach to the offset connectors Note Connections are Hot Left Cold Right Sealing Washer Filter 10 Tighten the connections using a suitable spanner 11 Install the divertor and rigid riser assembly go to section Divertor and Rigid Riser Assembly Installation Divertor and Rigid Riser Assembly Installation 1 Fit the divertor onto the mixer outlet and tighten the M4 x 5 mm grubscrew with a2 mm hexagonal key supplied Note The divertor must be fitted as illustrated with the divertor knob atthe right and the outlet at the back of the mixing valve Screw the rigid riser rail together then into the rigid riser overhead pipe Locate the rigid riser rail into the divertor outlet and the rigid riser overhead pipe into the securing bracket make sure that they are pushed fully home Important Align the rigid riser overhead pipe with the securing bracket using the pin Then using a spirit level make sure that the rigid riser rail is vertical and mark the position ofthe fixing holes for the securing bracket on the wall Caution Do not cut the rigid riser rail For solid walls drill the fixing holes for