Home

USER GUIDE - Patron Security Specialists

image

Contents

1. 11 The control panel indicates alarms and warns your correspondents or keyholders 14 The control panel indicates faults 15 Performing a real test on your security system 16 Remotely operating your security system 17 Additional keypad functions 18 User guide gt gt YOUR DAITEM SECURITY SYSTEM detect deter remote switched relay outputs receiver smoke detector motion external strobe detectors siren universal i multicontact transmitter _ detectors A EEA N su BIRA transceive radio relay repeater transceiver remote control units A remote keypads control hardwired and information listen in S ia remote keypads and speak out yp talk back module user control OPERATING YOUR SECURITY SYSTEM The control panel has up to 3 intrusion protection groups that can be operated separately or together Switching your system ON or OFF e Remote control unit press ON or OFF e Control keypads or interface 9909 9 master code OFF d A or ees ON ARMED ON all groups switched on armed Switching your system ON for PARTIAL part set operation e Remote control unit appui sur la touche Partiel 1 ou Partiel 2 TOO TH E 999 CD t Partial 1 sroup 1 only armed e Contro
2. When the call is to an individual alone the system OFF command stops the call trans mission to the correspondents 16 Dait ii REM OTE LY OP FRATING YO UR SE C URITY SYSTEM if telephone module board installed Your control panel confirms the code is correct with a long beep followed by announcing the system status Your control panel picks up the call Boe master code Call your control panel using a DTMF tone dial telephone device fax answering enter the switching code machine etc 5 1 to 9 programmed I by your installer another device picks up the call system status announced To modify system For Disarming x status press i D control panel OFF x For Arming control panel armed For menu return to main menu For system control e command sent JA Pr GK Sartze gite see table below To modify the call To check number saved JA number press announced new number saved n of Ist announced mm correspondent I For menu x ut return to mam merr User mode OFF Group 1 D amp AD Armed Group 1 LL LE ZZ OFF Relay 1 Test mode QD OFF Group 2 DD Armed Group 2 MOG Armed Relay 1 6 4 OFF 2 t OFF Group 1 2 LL Zu JE Armed Group 1 2 aD OFF Relay 2 Armed 2 UZ OFF Group 3 GO O Armed Group 3 JIE A Armed Relay 2 Armed partial 1 2 5 OFF Group 13 0309 Armed Group 1 3 ERREZE
3. 93939 QO 9999 9999 A Current New master code Repetition master code of new master code Example do not copy ESE SE 50 099 9 SE 099 9 DD For reasons of security we recommend you change your keypad access codes regularly and keep the keys clean To prevent any undesired calls to your remote monitoring company do not end your master code with a 0 Modifying your USER CODES The user codes limit access to specific functions They are designed for occasional users 999 9 399 9999 8 9999 99 w K Master code from 1 to 16 New user code Repetition of new user code Example do not copy 1456 user code 2 D293 202 D DYDD E DYDD EE When a user code is saved it is automatically authorised The user code authorisation sequence does not need to be entered again DISABLING or ENABLING your USER CODES The following procedures enable or disable user codes without modifying their programming 9399 DDO 9 D Master code from 1 to 16 0 disable pan 7 RESTRICTING access to control functions The user codes can provide separate restricted access to e certain keypad control keys e certain groups Only the control keys or groups selected during the master programming can be accessed when a user code is entered To allocate a user code to a certain key s only press 9939 9 299 9 9999 9 9999 99 939 99 _ aa master code user c
4. Control panel siren 311 21W 312 21W User guide You have just bought a DAITEM security system designed to cover all your protection needs We would like to thank you for your confidence With TwinBand and TwinPower you will benefit from the flexibility of a totally wire free system based on dual band radio technology and a doubly secure power supply EOI Correct programming is confirmed by a long beep or the green LED indicator lamp lighting up Incorrect programming is indicated by 3 beeps or the red LED indicator lamp flashing IMPORTANT ADVICE Your security system is simple to use We advise you to switch it on arm every time you leave your home Do not leave your remote control in view Keep a back up remote control in a secret place If one of the devices in your system is lost stolen or sabotaged call your installer right away Keep the access codes to your remote control keypads secret SOME PRECAUTIONS TO FOLLOW When you are at home Do not leave entrances doors and windows open for no reason Switch your system to partial protection mode Part Set to protect unoccupied rooms When you leave home Close all the protected doors and windows Switch on arm your security system If necessary check for any indications of faults or doors and windows left open When you re going to be away for a while Check that all doors and windows are closed Check your se
5. Armed partial 2 2 OFF Group 2 3 l 4 1 Armed Group 2 3 GD CORED Armed presence mode ES 3 OFF Group 123 DDO Armed Group 1 2 3 DM UZU LE 17 ADDITIONAL KEYPAD FUNCTIONS Checking system status 993938988 039399 9 master master A code code System status Silently operating your system 9339 93993999 Q nn ee Ze Wait Key s code 2 sec for command to be sent Triggering an alarm P 9 9 9 2 2 EA or Alert personal attack master Press for more than 2 sec code Loud siren sounding can cause hearing problems The necessary precautions must therefore be taken when performing device triggering tests Triggering a silent alarm if a keypad key has been programmed iP 939939 GO AA o gt Silent alarm master code Press for more than 2 sec Triggering a fire alarm if a keypad key has been programmed 9999 D II DD 9999 N Z master master code code Fire alarm Activating or de activating the chime 999 QDD PB master code Changing your system to summer time or winter time 9339 8939909 99 master code 2999 9 9993 AA master code 18 GOIO JOLd 1noullA p lJipoui aq Aew qu uinoop en1oelluo2 uo N S0 0 V ZP6EOR
6. D information number DELETING a saved NUMBER You can delete your correspondents telephone numbers separately 2999 99 I 9 IP Master code D 1 number D 2 number D 3 number D information number 12 pan ii Test call procedure fr press on 0 on the telephone handset unit to acknowledge and terminate the telephone transmission Telephone dialler call cycle procedure Your first correspondent does not answer as s he is already on the phone or has not terminated the call cycle correctly e the telephone dialler calls the number saved in the next memory e if none of the correspondents stop the call cycle or they are all on the phone or not answering the complete call sequence is carried out Acknowledgement Procedure BOT is and termination For each cycle if the 1st calls are not acknowledged transmission continues on to the following numbers in the cycle As soon as one of the cycle calls is acknowledged transmission stops For voice transmission to an individual correspondent for information purposes owner s mobile for example This infor mation call does not acknowledge and terminate the cycle 13 THE CONTROL PANEL INDICATES ALARMS AND WARNS CORRESPONDENTS e Alarms intrusion personal protection technical problem e Voice indication specifies tampering or fire are indicated e the date and time the alarm occurred when a Disarm command switch
7. LT RADIO LINK REMOTE CONTROL and the control panel N 15 PERFORMING A REAL TEST ON YOUR SECURITY SYSTEM You are now going to perform a real test on your security system This test will trigger the alarm units and trans mit a message to your remote central station monitoring company or individual correspondents by phone if a telephone transmission module has been installed by your installer We recommend you warn the person s in charge of remotely monitoring your system beforehand Close all the entrances and leave the protected areas for at least 90 secs to allow any movement detectors to set Switch ON ARM the system e when it receives the ON command the control panel responds beep armed beep armed Wait until the end of the Exit time delay e the control panel announces armed After 90 secs enter a protected room e the control panel and siren are triggered e the telephone dialler calls the programmed correspondents depending on the type of event transmitted Let the sirens sound for 30 sec and then switch OFF disarm the system e on receipt of the OFF command the Beep OFF on 21 5 2004 at 7 30 sirens stop and the control panel responds PM intrusion detector 3 group 1 Beep OFF on 21 5 2004 at 7 30 PM intrusion detector 3 group 1 ed p Check the alarm was transmitted by phone to your programmed correspondents
8. OFF is received e the type of alarm e when the system is remotely controlled e the identity of the device generating the alarm Protection against intrusion Intruder on premises BEEP INTRUSION DETECTOR N GROUP N BEEP INTRUSION CONFIRMED Intruder moving about on premises DETECTOR N GROUP N Personal Attack d gg rg Alarm or silent alarm triggered by control unit BEEP ALARM Technical protection i a U S a Dye e0s BEEP TECHNICAL ALARM DETECTOR N associated with the universal transmitter Protection against fire i gg z Fire protection triggered by a detector BEEP FIRE ALARM DETECTOR N Fire protection triggered by a remote b BEEP FIRE ALARM REMOTE CONTROL N control unit Protection against system tampering BEEP TAMPER REMOTE CONTROL CONTROL Attempt to open or remove a control interface PANEL Attempt to open or remove a keypad BEEP TAMPER REMOTE CONTROL N Attempt to remove or open the control panel BEEP TAMPER CONTROL PANEL BEEP TAMPER SIREN N Or BEEP TAMPER RELAY N Attempt to remove a siren or radio repeater relay Attempt to open or remove a detector BEEP TAMPER DETECTOR N Radio jamming detected Telephone line cut detected lt The alarm memory is automatically deleted the next time the system is armed 14 THE CONTROL PANEL INDICATES FAULTS e The control panel continuously monitors the state of e radio link system devices batter
9. curity system is operating properly by actually testing it Switch on arm your system IMPORTANT REMARK The installer can access your system remotely in order to perform maintenance or uploading amp downloading operations via a telephone and computer accord ing to the conditions outlined in this guide It is up to your installer to define with you the specific contractual conditions for accessing your system WE WOULD APPRECIATE YOUR SUGGESTIONS If you have any comments about how we might improve our guides and our products we would be grateful if you could send them in writing to Daitem Technical Service Atral UK Itd Hortonwood 50 Telford TF1 7FT 01952 67 5566 info atral co uk LEGENDE important points 3 press once recommendations ieS press and hold d pan ii CONTENTS Your installer has provided you with a memo sheet to help you use your system on a daily basis Your DAITEM security system 4 Operating your security system 5 The information keypads provide information about device status and messages from the control panel 7 Modifying your access codes 8 Defining access for remote upload download service computer operations 9 Regularly testing your system Test mode 10 Your telephone dialler warns your designated correspondents or keyholders
10. h an entrance s open Control keypad or interface Switch the system ON Close the entrance Switch the system ON End of exit time delay The contro panel is not iS The system can be switched on and armed if there is no anti tamper fault or entrance open SWITCHING OFF YOUR SYSTEM UNDER DURESS feature only accessible through remote monitoring This feature allows you to discretely send out a warning if you are forced to disarm your alarm system under threat The system behaves in exactly the same way as if you were disarming it but it sends a specific alert message to the remote central station monitoring company via the telephone line 99309 9 9 HE This duress option needs to be selected by your installation company eta OFF and with the agreement of the central station monitoring company group OFF a group armed Daitem security system THE INFORMATION KEYPADS PROVIDE INFORMATION ABOUT DEVICE STATUS AND MESSAGES FROM THE CONTROL PANEL Groups i i DE 3 secs The information keypads allow you to Sei e operate your system O83 operation e check system status at any time O4 The voice keypads provide all control panel messages and indicate OC e the status of the protection groups O Entrances e the status of the doors and windows which have contact sensors fitted ed dee sensor points alarms Alarm
11. l keypad or interface master code artial 1 I f j r _ beep armed partial 2 DTME DD Fi Partial 2 group 2 only armed O partial 2 Switching SEVERAL GROUPS ON and OFF Using a control keypad or interface press DDD D P Bq gt h master code D group 1 2 group 2 EN group 3 Examples e Arming group 3 999 9 9 4 master code ON beep armed beep OFF e Switching off group 2 d E on j 999 OA 9 7 master code OFF e Switching off group 1 group 2 beep OFF group 1 20 920090020 master code Groups 1 2 OFF group OFF group armed GY group unchanged 5 OPERATING YOUR SECURITY SYSTEM cont ARMED PRESENCE stay mode The control panel has a protection mode that makes it possible to arm group 1 only and cause the system to generate a discrete response in case of intrusion Armed Presence mode or stay mode G ZZ Armed Presence mode group 1 only is armed 5 master code presence mode There is no entry or exit time delay in presence mode Switching the system ON Arming when an ENTRANCE is OPEN or there is a FAULT The control panel is factory configured to prevent the system from being armed when a protected entrance door fitted with a con tact sensor point is open or there is a protection mechanism fault This factory configuration can be modified by your installer Example system armed wit
12. ode repetition from 1 to 16 of user code control keys authorised Example To allocate user code 1 to Partial 1 operation only press DDI Q DOD E DADD E DADD R BD D x Noe EL Partial OE s EE Partial 1 key To allocate a user code to a certain group s only press 2399 299 9999 9999 B I E master code f user code repetition from 1 to 16 of user code n of groups authorised In this way the user code only allows the authorised groups to be armed or switched off disarmed DEFINING ACCESS FOR REMOTE UPL OA DIN G D O WNL OA DING OP FRATI ONS if telephone transmission module board installed In compliance with current regulations access to system uploading or downloading requires your explicit authorisation this is why by default uploading downloading operations are only authorised if your control panel is in Test mode see page 13 Using the uploading downloading software your installer can perform different operations remotely e remote configuration to check or modify your system s configuration e remote inhibition to activate or inhibit one or several system devices e events log reading to check the list of time and date stamped system events that have occurred You can modify your installer s uploading downloading access rights and conditions It is up to you to define the most suit able procedure to be adopted with yo
13. peak out talk back loud speakers Command for all listen in microphones Repetition of listen in period 1 min Command to stop listen in and terminate transmission 11 User guide YOUR TELEPHONE DIALLER WARNS YOUR CORRESPONDENTS OR KEYHOLDERS cont SAVING or MODIFYING your correspondents numbers You can programme telephone numbers for your correspondents separately using the control panel keypad or a control inter face Memories 81 to 83 are dedicated to your correspondents numbers Memory 89 is dedicated to the information number DIII IO DPP The telephone numbers must Master telephone n code 20 figures max be different If the memory is empty the control panel generates a long beep at the end of the reading D 1 number D 21 number 3 3 number D information number CHECKING and TESTING the numbers saved You can check your correspondents telephone numbers separately using the control panel keypad or the control interface 29299 99 9 DIP D 1 number D 2 number 3 3 number D information number TESTING the call to your correspondents You can test your correspondents telephone numbers separately First let your correspondents know that you are going to perform a test call We recommend that you systematically do this every time you save a new number 99399 89 999 9 Master code D 1 number D 2 number 3 3 number
14. rt key on a remote control for more than 2 seconds Alert Press for more than 2 secs Put the control panel back to user mode 999 D e d master code WAT TSE gt Gradual siren sounding for 3 secs Gradual siren sounding and strobe for 5 secs YOUR TELEPHONE DIALLER WARNS YOUR CORRESPONDENTS OR KEYHOLDERS UTZ The chapter on telephone transmission applies to your installation if your installer has installed the additional i telephone transmission module If this module has not been installed go directly to page 14 Procedure for a voice call to an individual To make it easier to listen in to the site the control panel siren temporarily stops Procedure for a call to a remote central station monitoring company call picked up by remote monitoring company Remote i E monitoring requency monitoring company company ring 1 transmitted response frequency gt lt gt dk SFU Wr erie eratik gi User site test dialling DIMF message transmitted long beep gt lt gt change to listen in mode List of commands possible during the listen in period Depending on the alarm transmitted you have access to a listen in mode During this period you can send commands using the keys on your telephone handset unit Command for all s
15. s faults or alarms e faults LED Indicator lamp and voice message indications LED Indicator lamps lit System status Voice message Group 1 Group2 Group3 Contacts Faults Alarms e FF Armed R R R Beep Armed Partial 1 R beep armed partial 1 Partial 2 R beep armed partial 2 Armed group 1 R X X Beep armed group 1 Armed group 2 X R X Beep armed group 2 Armed group 3 X X R Beep armed group 3 OFF group 1 G X X Beep OFF group 1 OFF group 2 X G X Beep OFF group 2 OFF group 3 X X G Beep OFF group 3 brie Beep armed presence mode mode Alarm memory R Beep OFF alarm system Fault memory Y Beep armed fault system Contact open Y Beep armed contact X open without anti tamper system fault or entrance open for 3 secs group OFF alarm indication red LED indicator lamp orange LED indicator lamp for 3 secs yellow LED indicator lamp for 3 or 5 secs group armed control panel in presence mode for 5 secs faults or entrances open lt Only the commands sent from the control and information keypad light the LED indicator lamps Only the commands issued from the voice keypad generate the above voice messages Commands issued by another control unit have no effect on the voice keypad MODIFYING YOUR ACCESS CODES Modifying your MASTER CODE The master code provides the main user with access to all system controls
16. ur installer FORBIDDING access to uploading downloading operations 939339 9 99393 99 8 D9 99 master code AUTHORISING access to uploading downloading according to the code used and the system status 9939 9 9093999989 9 DB master code In 24 hour mode access to uploading downloading via the engineer installer code is not authorised if your system is ARMED D uploading downloading code 0 system in test mode D engineer installer code D inhibited 3 uploading downloading D 24 hour according and engineer installer code to system status REGULARLY TESTING YOUR SYSTEM TEST MODE UE Once a year or before going away for a long period we advise you to test your security system The test mode will allow you to test each system unit Loud siren sounding can cause hearing problems and the necessary precautions must therefore be taken when testing device triggering Switch the control panel to test mode 999 DDA 9 master code Test each detector e Move in front of each motion detec tor installed in rooms offices etc e Check the systems voice message e Open and then close all the entrances protected by door and win dow or multicontact detectors e Check the system s voice message Test each remote control unit e Press the OFF button on each remote control or e Enter your master code and press the OFF button on each keypad Test the alarm siren units Press the Ale
17. y e The control panel indicates faults anti tamper system e when an ARM or DISARM command is received e telephone line availability e by remotely checking system status Device battery failure Control panel battery low BEEP FAULT BATTERY CONTROL PANEL Detector battery low BEEP FAULT BATTERY DETECTOR N Siren battery low BEEP FAULT BATTERY SIREN N Radio repeater relay battery low BEER FAULI BATI Ry RELAY NS BEEP FAULT BATTERY REMOTE CONTROL N Keypad or control interface battery low or BEEP FAULT BATTERY REMOTE CONTROL CONTROL PANEL Device anti tamper mechanism failure Control panel anti tamper system fault BEEP FAULT TAMPER CONTROL PANEL Detector anti tamper system fault PET TAVE TAMPER BSE D IN Bo i GROUP N BEEP FAULT TAMPER SIREN N or BEEP FAULT TAMPER RELAY N Siren or radio repeater relay anti tamper system fault Control unit anti tamper system fault BEEP FAULT TAMPER REMOTE CONTROL N Telephone line fault Connection fault or telephone line unavailable Device radio link fault Loss of control panel radio link BEEP FAULT RADIO LINK CONTROL PANEL Loss of radio link between a detector BEEP FAULT RADIO LINK DETECTOR N and the control panel GROUP N BEEP FAULT RADIO LINK SIREN N or BEEP FAULT RADIO LINK RELAY N Loss of radio link between a siren or a radio repeater relay Loss of radio link between a keypad BEEP FAU