1. 9452 9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4 Channel Minicom 496330 Issue 1 1 of 10 9452 3 Introduction The 9452 and 9453 are fully programmable 4 zone control units designed to meet the requirements of both domestic and small commercial installations The basic 9452 system comprises a main control panel complete with built in keypad while the 9453 system comprises a blank end station and one remote keypad The 9452 control unit and 9453 end station both house the system electronics power supply battery and remote signalling device if fitted A numeric keypad and row of indicators LEDs are provided only on the 9452 control unit from which the user and installer perform the system operation Remote keypads provide the user with the facility to set and unset the system from strategic locations within the premises and allow the installer to pro gramme the system Up to TWO remote keypads may be connected to the 9452 3 A numeric keypad and row of indicators LEDs are also provided on the keypads to perform the system operation The keypads also have an optional key press PA facility if required Zones Display Keypads Expansion BS 4737 Log Panel Siren Extension Spkr Battery 12 Volt Power 12 V Aux Output Dimensions Weight Comms Output Input Outputs 2 of 10 Technical Specification Four plus
2. PA Entry Exit and global tamper LED One built in 9452 only plus up to two remote keypads 9425 None Full Spec 15 events Yes 9040 2 max if Internal Speaker is disconnected 1 9Ah Quiescent Panel 70mA 9425 RKP 40mA 350mA Panel h x w x d 163 x 257 x 72mm RKP hxwxd115x 115 x 28mm Panel 1 2Kg PA Intruder Open Close Line fault SAB SCB Strobe Prog O P PIR set latch or SD reset 496330 Issue 1 9452 3 Wiring EE 21VAC aes SWITCH KEYPAD AREA a 9452 only J MICRO NVM Z1 Z2 z3 z4 osbobsksbeesopo RESET ENTRY EXIT VOL PINS PA BATT AIT E el glelelel golo ele er 4 g Stb Bell 12V OV TR O P 112V OV r SIG LS ET 7 ua Normally Openn a rid HARNESS PLUS push to make Exit a LOCATOR Terminate Button Pia x Connect to Remote Keypad 9425 eee 00680 Terminals J 12V LAN OPEN CLOSE LINE MONITOR INPUT Figure 1 9452 3 PCB Layout Communicator Output Pins Pin on panel Function Colour Pin on communicator Pin 1 PA Red ST2 Pin2 Line Monitor Input Blue O P Pin 3 Intruder Yellow ST3 Pin 4 Open Close Black ST4 Pin 5 12V Brown 12V Pin 6 ov Orange ov Notes 1 Pins 1 3 and 4 are removal of positive in alarm to trigger 2 Pin 2 is a 12V ve input for Line Fault 3 If a communicator is fitted and has an output for line fault connecti
3. inated permanently Any condition indicated by a combination of the Fault Service or Alarm LEDs are to be considered an abnormal condition as shown on the opposite page 8 of 10 496330 Issue 1 9452 3 Fault Finding Oentrviexit PO O Zone 1 pay O Zone 2 FULL O O Zone 3 PART _ Zone 4 panic al SERVICE TAMPER power pay ENTRY EXIT Zone 1 O Zone 2 FULL O O Zone 3 PART _ O Zone 4 panic z SERVICE TamPeR ans power oO pay ENTRY EXIT O Zone 1 O Zone 2 FULL O O Zone 3 PART _ O Zone 4 i O Be SERVICE TAMPER FAULT Telephone line fault Alarm activated on Zone 1 System requires Engineer reset Tamper fault Battery not charged or missing remote keypad missing back tamper normal circuit tamper or bell tamper faults If there is no SAB fitted link OV to TR ENTRY EXIT power ENTRY EXIT power ENTRYIEXIT power d O Zone 1 pay O Zone 1 pay Zone 1 pay O Zone 2 FULL O O Zone 2 FULL O O Zone 2 FULL C Zone 3 PART _ Zone 3 PART C Zone 3 PART _ O Zone 4 Zone 4 O Zone 4 panic z O PANIC z O panic Z O Preen SERVICE Cee SERVICE et SERVICE FAULT C FAULT FAULT C Tamper fault has occurred Panic alarm has occured Mains failure Enter user code twice to clear Reset the panic button Check the fault LED is extinguished then enter the user code t
4. ng a ve to the Line Monitor Input will reduce any programmed bell delay to zero and give a visual indication on the panel LED LF 4 If a communicator is not fitted remove the communicator wiring harness from the main pcb 496330 Issue 1 3 of 10 Programming 9452 3 Keypad Wiring 9425 PCB PIEZO _ BUZZER or SWITCH VOL uesigovev VOLUME CONTROL FOR 42 ooog eur LINK FOR KEYPAD TONES ONLY REMOTE KEYPAD ADDRESS NO 2 To next FROM fi CONTROL e keypad if PANEL using daisy s chain IP SIG ov V A T EXITTERMINATE PUSHBUTTON Figure 2 Keypad Connection Notes 1 Maximum cable distance Daisy chain 300m Star Wire 100m per leg 2 Do not wire the extension speaker or circuit wiring within the same cable as the remote keypad Programming Initial Start Up Before applying power to the control panel or end station ensure that all used circuits are connected The control panel or end station lid switch should be defeated or closed and NO power connections to detectors sounders or battery should be made at this stage Note If connections to the bell and AUX power are made when the system is powered up damage to the main pcb may occur 1 Apply mains to the control panel or end station The green Power and Day LED will illuminate and the internal sounder will sound 2 Key in the factory default customer code 1234 The internal s
5. ntrol panel mains and battery 2 Find the RST pins located to the middle of the control pcb 3 Place a small screwdriver blade to short between the RST pins With the blade still across the pins power up the control panel battery first then Mains All the LEDs will flash 4 Remove the screwdriver blade The control panel loads the factory default codes 5 Key in 1234 then press 0 Enter 7890 Momentarily close then open up control panel lid Re program the system Engineer Reset An engineer can reset the system without opening the control panel or end station lid 1 Press 0 then Enter 2 Key inthe Engineer Access Code 3 Keying9 To Re Enter Programming Mode 1 Press 0 then Enter 2 Key inthe Engineer Access Code The Fault and Service LEDs flash and the internal sounder starts bleeping 3 Open the control panel or end station lid The internal sounder stops bleeping and the Service LED glows stead ily The system is now in programming mode To Leave Programming Mode 1 Close the panel or end station lid 2 Keyingg Fault Finding Under normal conditions the Fault Service and Alarm LEDs will not be illuminated Only the Mains Day Full and Part Set LEDs should be illuminated during normal use of the system Any other LEDs which are illuminated or flashing signify a fault or alarm condition Note The Mains LED will be illum
6. ounder will stop and the Tamper Service and Fault LEDs will be flashing 4 of 10 496330 Issue 1 9452 3 Programming Commands 3 Key in the factory default engineer code 0 followed by ENTER then 7890 The Fault and Service LEDs will flash and the internal sounder will be bleeping 4 Open the control panel or end station lid The internal sounder stops bleeping and the Service LED will be steady Make connections to AUX power stand by battery and connections to SAB Proceed to program the system Note If an SAB SCB module is fitted within the bell it will continue to ring until the panel supply is connected and until the bell cover lid tamper switch is closed Programming Commands To change the factory default program use the commands listed in this section as follows 1 Enter the command number 2 Enter one or more digits to give the new program 3 Press ENTER The panel will give a double bleep to show that it has accepted the command If you enter the command incorrectly the panel gives a single tone Default Settings When delivered from the factory the panel is programmed as follows Zone 1 Entry Route Part Set zone 01 36 Zone 2 Normal alarm active in Part Set Omit allowed 02 16 OMIT Zone 3 Normal Alarm active in Part Set Omit allowed 03 16 OMIT Zone 4 Normal Alarm active in Part Set Omit allowed 04 16 OMIT Zone 7 E E part set 076 Use
7. r code 1234 Engineering Program Commands To change Key in Followed by ENTER Zones 1 4 01 04 0 Not used 1 Normal Alarm 2 24 Hour Alarm 3 Entry Route 4 Double Knock 5 Chime 6 Part set zone OMIT Omit Allowed 496330 Issue 1 5 of 10 Engineering Program Commands 9452 3 To change Key in Followed by ENTER Default Entry exit zone options 07 0 Reset to none 5 Chime 6 Part set zone Programmable Output 11 18 PIR set latch J 29 Shock sensor reset Engineer Access 20 Any 4 digit code 7890 Bell output type 21 0 SAB 1 SCB Internal sounder 22 1 Follows strobe 0 Follows bell PA 30 0 Audible Alarm 1 Silent Alarm System Reset 31 0 Customer Reset 1 Engineer Reset Abort facility 32 0 Disabled 1 Enabled Keypad PA 33 0 Disabled 1 Enabled System status 34 0 LEDs ON when set and part set 1 LEDs OFF when set and part set Exit Mode 35 0 Timed or Terminated 1 Final Door Set Rearm 40 0 Never v 1 Once 2 Twice 3 Three times 4 Always External sounder delay 41 0 Nil v 1 1 5 mins 2 3 mins 3 5 mins 4 10 mins 5 15 mins 6 20 mins 7 No duration Ext sounder duration 42 0 Nil 1 1 5 mins 2 3 mins y 3 5 mins 4 10 mins 5 15 mins 6 20 mins 7 No duration VV VV ANON NN 6 of 10 496330 Issue 1 9452 3 Refresh NVM System Memory Chip To change Key in Followed by ENTER Defaul
8. t Entry Time 43 0 Continuous 1 10s 2 20s 3 30s 4 60s 5 90s 6 120s Exit Time 44 0 Continuous 1 10s 2 20s 3 30s 4 60s 5 90s 6 120s CSID code 50 nnnn key in four digit code Part Set Entry Exit 60 0 As Final Exit 1 Normal Alarm Part Set Entry Response 61 0 As Entry Route 1 Start Entry Timer Part Set Exit Mode 62 0 As Full Set 1 10 Second Set 2 Instant Set Part Set Alarm Response 63 0 Local No comms 1 Full Alarm Engineer Log 90 1 see earlier events 3 to see more recent events ENTER to quit log 15 events max External Sounder 91 ENTER to stop test Strobe 92 ENTER to stop test Internal Sounder 93 ENTER to stop test Test keypad LEDs 94 ENTER to stop test Output 1 95 ENTER to stop test Walk Test 97 ENTER to stop test Load Factory Defaults 98 Leave Engineering Mode 99 Refresh NVM System Memory Chip The 9452 3 control panels have a Non Volatile Memory chip which retains all programmed information and access codes If the system suffers a total power failure the NVM will retain all information and the panel will only require powering up and resetting However if the end user forgets the user access code or the installer wants to return the panel to the factory pro grammed settings continue as follows 496330 Issue 1 7 of 10 Fault Finding 9452 3 os Power down the co
9. wice to clear the system ENTRY EXIT power Zone 1 pay Zone 2 FULL O Zone 3 PART C O Zone 4 Panic z O SERVICE TAWPER a ENTRY EXIT power Zone 1 pay Zone 2 FULL O Zone 3 PART C O Zone 4 panic tO oo SERVICE FAULT C Zone 1 programmed as 24 hours has activated Enter the user code to stop the sounder s Close the 24 hour door or circuit Check the fault light has extinguished then enter the user code to clear the system Either an exit fault or alarm activation has occurred in zone 1 Enter the user code twice to clear the system 496330 Issue 1 The power light flashes 9 of 10 Full Set System Part Set System Unset Reset System Omit zone Omit 24 hr zone Change User code Read Log Chime On Off Bell Test Walk Test 10 of 10 9452 3 User Commands 1 ENTER User code 2 ENTER User code User code 1 or 2 ENTER User code OMIT zone number repeat OMIT zone number for other zones as required OMIT ENTER User code zone number zone number for other zones as required 4 ENTER Old code Old code the system beeps twice New code the system beeps twice 5 ENTER User code 1 to read earlier events 3 to read later events ENTER to leave the log 7 ENTER User code 8 ENTER User code 9 ENTER User code ENTER to end the test 496330 Issue 1
Download Pdf Manuals
Related Search
Related Contents
Samsung 삼성 헤드셋 FiberCom Media Converter User Manual V.1.01 Sony Alpha NEX-7 NEX-7/B NEX-7K/B NEX7 NEX-7KB Body Black SEL 16mm Lens SEL-18200LE Lens Case 32GB Battery - NEX はじめにお読みください・クイック設定ガイド(5.00MB) AVR 505 Limited Edition Audio/ Video Receiver Bush Generic 2yr 6LIM.indd 高濃度ガス検知器コスモテクター XP-3140 デイジタルマルチリレー 98-112a Descripción Campos de aplicación Datos técnicos Modo de empleo User Manual Automated Perimeter Copyright © All rights reserved.