500r Installation and User Guide
Contents
1. take up to two seconds variable to transmit after detecting a moving person WHEN DOOR OPENED TAMPER AND ZONE LEDS FLASH AND INTERNAL ALARM SOUNDS Detector case not properly closed or not screwed down fully to close front or back tamper switch SAB WILL NOT STOP RINGING SAB not receiving power e Check fuse F1 Check tamper switch on external sounder Ensure cover on External sounder is secure First to Alarm Indication When several alarm events occur before the user can reset the system the control unit indicates which event occured first It does this by flashing LEDs lit by the first event and lighting LEDs steadily for subsequent events For example if the control unit detects a tamper on zone 2 followed by a violation on zone 3 then the Tamper and zone 2 LEDs flash while the Alarm and zone 3 LEDs glow steadily 496360 Issue 1 11 of 12 From the Keypad Full Set Unset Part Set Silence Bells Reset Change User Code Read log Walk Test Test Bell Test Strobe 500r User Commands User code ENTER User code User code OMIT zone number ENTER User code RESET User code 2 new code User code 3 3 to read earlier events 0 User code 1 activate detectors 0 to end test User code 5 0 to end test User code 4 0 to end test From the 525 Remote Setting Device Full Set Part Set Unset PA 12 of 12 Press Arm
2. time Deleting Detectors Command 82 If you wish to change detectors then the control unit cannot learn a new detector for a zone that is already in use You must delete the existing detec tor first as follows 1 Enter programming mode if you have not already done so 2 Enter 82 on the keypad The Standby LED flashes The LEDs of zones that already have detec tors glow steadily The LEDs of zones with no detectors stay off The control unit uses the Jamming LED for any 502r or 525r s 3 Enter the number of the zone you want to delete use 9 for 502r and 525r s The LED of the zone you selected flashes Note The control unit deletes all 502r and 525r s if you select 9 4 Press 8 on the keypad The LED of the zone you selected goes out and the control unit gives a double bleep 5 Repeat steps 2 to 4 for any other detectors you want to delete Programming Commands To change the factory default program use the commands listed in this section as follows 1 Enter the command number The Alarm LED flashes if the current program is the factory default 2 Enter one or more digits to give the new progam 3 Press Reset 496360 Issue 1 7 of 12 Restoring Factory Default Program 500r The control unit will give a double bleep to show it has accepted the command If you enter the command incorrectly the control unit gives a single low bleep When delivered from the factory the control unit i
3. 1 3 of 12 500r Wiring External Bell Figure 9 shows an example of connections for a typical external bell see the manufacturers instructions supplied with individual units for further informa tion on wiring diagrams CONTROL PANEL BELL OR SIREN O P1 12V O P2 12V BELL STR TR OV TYPICAL BELL MODULE ISIAIGI S SO DIO Seu 2 Hold off Hold Off O ve Ring Z Tamper Return ve ve STROBE Figure 9 Typical External Sounder Connections Make connections to the control unit and SAB module as follows STR Negative trigger in alarm for strobe light BELL Negative bell trigger 12V Positive bell module hold off voltage Supply OV Negative bell module hold off Supply TR Negative tamper return from bell module to control unit Notes 1 SAB shown for negative applied 2 Link tamper return to OV if no external bell is required 3 Connect all bell wiring to the control unit with the exception of the bell trigger The bell siren will continue to ring from the on board battery until the final connections are made after initial power up See Programming Initial Power Up 4 of 12 496360 Issue 1 500r Fitting a 660 or 8440 Communicator Fitting a 660 or 8440 Communicator OIP1 12V O P212V BELL STR TR OV IIIS VJSVJeg Bjo O LF O ov Ola
4. 500r Installation and User Guide Compatible Equipment 502rUK 50 Watch Pendant PA 509rUK 50 Smoke Detector 515rUK 00 10 metre passive infra red movement detector 525rUK 00 Remote Set Unset Full and Part Set unit plus PA facility 535rUK 00 Universal door contact transmitter 545rUK 00 Radio Signal Strength Meter 546rUK 00 Test Transmitter 8440UK 01 4 Channel Digital Communicator 660UK 00 4 channel wire in speech communicator 09040UK 00 16 Ohm loudspeaker sounder 496360 Issue 1 1 of 12 500r Introduction The 500r is a programmable Radio Alarm Systems designed specifically for domestic and small business premises The 500r provides seven zones with a PA on zone 8 A basic system comprises a control unit with built in keypad and associated radio detectors The control unit houses the system electronics power supply battery and 660 Speech Communicator if fitted A numeric keypad and two rows of Light Emitting Diodes LEDs allow the user and installer to operate the system Up to three remote setting devices can also be used on the 500r to set or unset the system and act as Personal Attack alarms Each detector and remote setting device contains a digital identity code that the control unit learns during installation The code is one of over 16 million possibilities This ensures that the control unit will not respond to any other detectors or remote setting switches apart from the ones it has learned The rad
5. Press Night system sets omitting any zones previously omitted using the keypad Press Off Press Arm and Off together 496360 Issue 1
6. ction and fuse TAMPER FLASHES CONTROL UNIT WILL NOT RESET Check connections and ensure external sounder tamper switch is fully closed Ensure cover on External sounder is secure FAULT TONE LOW BATT LED ON Low battery in 502r or 525r indicated replace battery System can still be armed with low battery indication FAULT TONE LOW BATT AND ZONE LED ON Low battery in detector indicated replace battery System can still be armed with low battery indication CANNOT LEAVE PROGRAMMING MODE TAMPER AND POSSIBLY ZONE LED ON Tamper on steadily control unit tamper not closed Tamper flashing External sounder tamper not closed Zone LED with Tamper detector open or not screwed down firmly e Clear fault Press Reset Standby will glow steadily Key in 99 and Standby glow steadily JAMMING LED FLASHING Control unit detecting interference on same frequency as detectors Wait till Jamming LED goes out If problem persists call Scantronic Technical Support PIR DOES NOT DETECT MOVING PERSON NO RED LIGHT To save power after each activation the PIR sleeps for three minutes Any movement during the three minutes will extend the sleep period by another three minutes See PIR Installation Guide e Check detector battery PIR DOES NOT APPEAR TO TRANSMIT IMMEDIATELY WHEN DETECTION TAKES PLACE e This is normal The PIR may
7. ctors Command 81 You must make the control unit learn the identity of each detector in the system and link them to zones To do this 1 2 Enter programming mode if you have not done so already Enter 81 on the keypad The Standby LED flashes The LEDs of zones that already have detec tors flash The LEDs of zones with no detectors glow steadily The contol unit uses the Jamming LED for any 502r or 525r s Enter the number of the zone you want the control unit to learn use 9 for a 502r or 525r The LED of the zone you selected flashes all the other zone LEDs go out the Jamming LED flashes if you selected 9 Point the activity LED of the detector at the Learn sensor on the control unit marked by Learn Hold the activity LED of the detector close to the sensor Trigger the detector by operating the tamper or press a button on the 502r or 525r 6 of 12 496360 Issue 1 500r Deleting Detectors The activity LED on the detector flashes and transmits an identity code to the Learn sensor The control unit gives a short double beep when it learns the code 6 Repeat steps 3 to 5 for any other detectors you want the control unit to learn Notes 1 The default factory setting is Zone 1 as the Entry Exit zone 2 The control unit will not learn the same detector more than once 3 The control unit can learn a total of three 502r or 525r s in any combination Each device uses hidden zone 9 and zone 8 PA at the same
8. e control unit bleeps once every second 2 Press Omit three times 8 of 12 496360 Issue 1 500r Leaving Programming Mode The control unit gives a double bleep erases all the programs the user and previous engineers have entered and restores the original factory defaults Note The control unit will still remember any detectors that it has learned Leaving Programming Mode Command 99 The control unit will stay in programming mode until you enter a command to return it to user mode as follows 1 Close control unit lid 2 Enter 99 The amp and Standby LEDs glow steadily The control unit is now in user mode To Re enter Programming Mode 1 Make sure the control unit is unset 2 Enter Engineer Code The Standby LED flashes 3 Open the control unit lid The control unit gives a double bleep the LED goes out and the Standby LED glows steadily The control unit is now in programming mode Clearing a Control unit For a New User To remove all programming including detectors and Engineer and User codes perhaps to reuse the control unit with another user then while the control unit is unset 1 Open the lid 2 Remove the mains supply and disconnect the Battery 3 Short together the two middle CLR pins on the NVM Reset pin block and reconnect battery supply The control unit restores all its programming to the factory default settings and deletes all detectors Remove the short after two seconds Res
9. io operating frequency between the control unit receiver and the detectors is 418MHz with a bandwidth of 200kHz The radio section is ap proved to MPT 1340 The 500r system is designed to meet the requirements of BS6799 Class III and complies with all current NACOSS codes of practice for domestic and small business Audible ONLY intruder alarm systems The system can be certified by approved installers as a Wirefree Class III installation 2 of 12 496360 Issue 1 500r Zones Display Keypads Expansion Compliance Radio Section Radio section Log Control unit Siren Internal Sounder Battery 12V power Aux DC power Dimensions Weight Communicator Outputs Technical Specification 7 wirefree plus PA PA can use up to three 502r or 525r LED On board Remote Set Unset using 525r up to 3 per control unit None Product is CE tested to EN 50081 1 and EN 50082 1 Operating frequency 418 MHz at 200 kHz bandwidth CE tested to I ETS 300 339 draft standard 16 events Yes approx 80db at 1 metre 1 x 9040 16 Ohm loudspeaker approx 90db at 1 metre 1 9 2 1 Ah lead acid gel type rechargeable Control unit quiescent current 55mA 500mA max at 12V in alarm state h xw xd 163 x 257 x 74 mm 1 2 kg 50mA max PA and Burg outputs for 660 Speech Communicator or 8440 Digital Communicator Positive removed in alarm Bell and Strobe negative applied SAB 500mA total output 496360 Issue
10. s programmed with stand ard defaults for each command A WY in the right hand column of the table shows the default Omit Reset Yes Additional E Exit Zones 96 Zone number s 2 to 7 Reset Omit Reset Zone 1 only Tamper response 97 1 Reset Full alarm in user mode To change Key in Followed by Default Add Detector 81 see Learning Detectors none Delete Detector 82 see Deleting Detectors Entry Exit Time 86 A number 10 to 99 seconds Reset 30s Bell Duration 87 A number 01 to 20 minutes Reset 20 mins Strobe follows bell 88 1 Reset Yes Omit Reset Continuous Vv Engineer Code 89 New four digit code Do not use 0 zero for the first digit 7890 Remote Unset 90 1 Reset No entry timer required Omit Reset Needs entry timer Vv Bell Delay 91 Anumber 01 to 30 minutes Reset Omit Reset Reset nil Vv System Reset 92 1 Reset Engineer only Omit Reset Customer reset Vv Entry Route Zone 93 Zone number s 2 to 7 Reset Omit Reset None Vv PA Response 94 1 Reset Silent Omit Reset Audible Vv Omit Allowed 95 1 Reset No Vv Vv Yv Omit Reset Internal alarm in user mode Restore Factory Defaults 98 Omit Omit Omit Leave Programming 99 Restoring Factory Default Program Command 98 If you want to restore all the programming to the original factory defaults then 1 Enter 98 Th
11. tore the mains supply Close the lid Enter 1234 and press Reset Note To restore all the programming apart from the learnt detectors repeat steps 1 to 7 above but at 3 short together the top two LOAD DFLTS pins SL Ole 496360 Issue 1 9 of 12 500r 5 Testing PIR Testing and Lockout In normal use the 515r uses a three minute lockout timer in order to extend battery life The lockout timer works like this a The unit detects movement signals the panel and starts the lockout timer b If the unit detects movement while the lockout timer is running then it restarts the lockout timer but DOES NOT signal the panel c When the lockout timer expires the unit signals the panel the next time it detects movement If you want to test a 515r PIR in normal use you should leave the protected area and wait at least four minutes between activations To make testing easier the detector changes the lockout period to 10 seconds for the first half hour after you put the batteries in or after you trigger its tamper Note Make sure the control unit is in programming mode before you open or move any of the detectors This will avoid setting the tamper alarm off 10 of 12 496360 Issue 1 500r 6 Fault Finding Symptom Response FAULT TONE AND amp FLASHES CONTINUOUSLY Mains supply has failed control unit operating from battery only If Fault tone present mains failed over 1 hour ago e Check mains conne
12. x O sv i BURG Bie PA O st2 O sT O st OIP1 12V OIP2 12V BELL STR TR OV WENNS a Bie BURG Ol st Osm 8440 O st O st Ol 1x O ov oP1 Figure 10 660 or 8440 Communicator Connections The output connectors available are OP1 Burglar output positive removed in alarm 12V 50mA max OP2 PA output positive removed in alarm 12V 50mA max Fit the communicators inside the back casing Locate the communicator toward the top left of the back box Note Do not connect the 12V supply to the communicator until after the initial power up See Programming 496360 Issue 1 5 of 12 500r Programming Initial Power Up Note Before applying power to the control unit ensure that the bell trigger is not connected to any external sounders or 12V supply connected to the 660 Speech Communicator if fitted Close the control unit lid or defeat lid tamper Apply mains power to the control unit Key in the default user code 1234 if there is an alarm Ignore any LEDs that are lit at this stage Key in the engineer code default 7890 The Standby LED flashes Open the control unit lid or release control unit tamper The amp Power LED goes off and the Standby LED glows steadily The control unit gives a double bleep You are now in Programming mode Connect the battery and make any final wired connections for example to the bell and 660 Speech Communicator Learning Dete