Home

Torque Screwdriver Repair and Calibration Manual

image

Contents

1. Page 11 3 Place the 1 8 T Shaped Hex in the back of the screwdriver and Turn the set screw to set the calibration as follows c If the reading on the tester was below the accuracy limit for the value tested turn the set screw clockwise to increase the value Test and repeat this procedure until the readings are within the accuracy limits 2 Ifthe reading on the tester was above the accuracy limit for the value tested turn the set screw counterclockwise to decrease the value Test and repeat this procedure until the readings are within the accuracy limits 3 Place the end plug on the end of the screwdriver Page 12 CDI SCREWDRIVER TROUBLESHOTTING MATRIX Calibration accuracy at 2096 of scale Perform a minor calibration adjustment is out of tolerance NOTE If a minor calibration fails to bring the 20 of scale reading into tolerance or if adjustment causes the 60 or 100 of scale to fall out of the tolerance a major calibration is required OR Calibration accuracy at 20 60 Perform a major calibration and 100 of scale is out of tolerance OR Calibration accuracy at 60 and Perform a major calibration 100 of scale is out of tolerance The screwdriver is jammed See repair instructions for spherical ball Knob disassembled from screwdriver See knob engagement instructions Page 13
2. C LUPA A Division of Snap on Logistics Company Torque Screwdriver Repair and Calibration Manual CL91722977 e m Aid mm ASE PART NUMBER 21 275A 01 Rev A ISSUED MAY 2009 TABLE OF CONTENTS TITLE SAFETY INSTRUCTIONS WARNING amp CAUTION CDI TORQUE TESTING EQUIPMENT ILLUSTRATION INTRODUCTION CLEANING LUBRICATION REPAIR TOOLS REQUIRED INSPECTION ACCURACY VERIFICATION AND MINOR CALIBRATION PROCEDURE ASME B107 14 ISO6789 MINOR CALIBRATION ADJUSTMENT MAJOR CALIBRATION ACCURACY ADJUSTMENT How to check the Spherical Ball placement How to re engage the knob Calibration Instructions for Pre Set Screwdrivers CDI SCREWDRIVER TROUBLESHOOTING MATRIX PAGE S 1 2 5 7 7 8 9 11 11 11 12 13 REVISIONS The Torque Screwdriver Repair Manual was originated and first issued on December 2001 The manual will be reviewed and revised as necessary to assure that it contains the latest changes in product or repair changes In between revision product bulletins may be issued to assure any changes in product or repairs are supplied to authorized repair facilities m December 2001 0 0 0 0 0 0 0 000 O May 2009 i 3 4 6 8 9 10 amp 15 now 13 E S Deleted pages 11 amp 12 Affected Pages Written By Donna E Brunot Photographs By Gary Fitzhugh CDI ADJUSTABLE AND PRE SET TORQUE SCREWDRIVER WRENCH REPAIR MAINTENANCE AND TROUBLESHOOTING INSTRUCTIONS
3. SAFETY INSTRUCTIONS Failure to follow WARNING instructions can cause personal injury to the operator Failure to follow CAUTION instructions can cause the equipment to fail or break in use WARNING Always wear Safety Glasses or goggles when using or repairing hand tools Read this manual completely before repairing torque wrenches DO NOT use or tests a wrench that shows signs of damage cracked or broken parts caused by misuse Recommend replacement Check all sockets or other test accessories for wear damage or crack prior to their use with torque wrenches Do not exceed their rated maximum torque r CAUTION L um ms jet Periodic recalibration 1s necessary to maintain accuracy Periodic examination and cleaning is necessary to maintain the torque screwdriver Page 1 MULTITEST TORQUE CALIBRATION SYSTEM SURETEST TORQUE CALIBRATION SYSTEM EIT ELECTRONIC TORQUE TESTER Page 2 INTRODUCTION This manual covers the calibration repair maintenance and a troubleshooting guide to identify and remedy problems that could occur with CDI Torque Screwdrivers Each wrench model has an Exploded Illustration that lists the component parts and shows assembly particulars The exploded illustration must be used as a guide for assembling the screwdrivers CDI has a Service Centers that performs repairs and calibration on all of our products at the factory plus a list of factory authorized repair calibration centers thr
4. scale and tighten the screws Recheck the readings at 20 60 and 100 of scale If the screwdriver is calibrated torque the Bezel screws at 3 2 IN LB Then the set screw to 6022 IN LB Place a new end plug on the end of the screwdriver Page 6 9 Ifa minor calibration cannot be used to calibrate the screwdriver perform a major calibration Major Calibration Accuracy Adjustment NOTE A major nose cone adjustment is used to adjust all of the scale reading If the reading at 20 60 and 100 of scale are either to high or low to the required accuracy to adjust with a minor adjustment a major adjustment must be used to bring the accuracy within torque specification If the torque wrench requires major adjustment follow steps 1 through 4 1 Usea 34 open end wrench turning it clockwise to loosen and remove the cone nut 2 Turn the cone to set the calibration as follows a If the reading on the tester was below the accuracy limit for the value tested turn the cone clockwise to increase the value Test and repeat this procedure until the readings are within the accuracy limits or a minor adjustment could be used to bring the wrench within the accuracy limits b If the reading on the tester was above the accuracy limit for the value tested turn the cone counterclockwise to decrease the value Test and repeat this procedure until the readings are within the accuracy limits or a minor adjustment could be used to bring the w
5. or each reading If the readings are within the accuracy requirements for the test direction 6 or readings no calibration adjustment is required Page 4 Minor Calibration Accuracy Adjustment NOTE A minor knob scale adjustment is used to adjust 20 of the scale reading If the reading at 20 and 100 of scale are both either high or low to the required accuracy a minor adjustment may be used to bring the accuracy within torque specification If the torque wrench requires minor adjustment follow steps 4 through 8 4 Set the knob so that the scale is at 20 of full scale Remove the plug from the end of the knob 5 Testthe screwdriver and Adjust the handle clockwise to increase and counterclockwise to decrease the reading until the screwdriver read within specification of the 2096 reading example For a 100 IN OZ CDI screwdriver the low reading is 20 IN OZ and 18 8 to 21 2 IN OZ is the tolerance Page 5 6 Place the 1 8 T Shaped Hex in the back of the knob and Loosen the set screw Pull the knob back and turn it until it is on the 0 increment of the knob is aligned with the 2096 increment of the scale Push the knob back to engage it and tighten the set screw Recheck the reading 7 Usea 1 16 hex in a screwdriver to loosen and remove the 2 two screws on the scale bezel Remove the bezel Move the scale until the increment line 1s aligned to the lowest increment 8 Place the Bezel over the
6. oughout the world Contact CDI Sales or Service Center at 626 965 0668 or die technical assistance on the repair or calibration of CDI products CLEANING Wipe all exterior parts with a dry clean and lint free cloth DO NOT USE any abrasive or corrosive materials to clean any components of CDI Torque Wrenches LUBRICATION Super Lube MULTI Purpose Synthetic Lubrication with Teflon CDI Part 10 1000 NO SUBSTITUTES ALLOWED REPAIR TOOLS REQUIRED CDI Torque Screwdrivers Torque Tester range determined by the torque wrench to be tested 1 8 Hex T shape 9 16 Open End Wrench 34 Open End Wrench QC11200Torque Wrench 1 16 Hex 3 8 Sq Dr ratchet head J shank pd pb jem o oe o Sfo We recommend that CDI torque testers be used to test the calibration accuracy of CDI manufactured torque products CDI manufactures a complete line of torque testing equipment from moderately priced testers to complete state of the art test systems used in metrology calibration laboratories all over the world Contact CDI Sales or Service Center at 626 965 0668 or Page 3 INSPECTION Inspect all wrenches repaired to determine that they are 1n an operational condition by visually inspecting for worn broken cracked or damaged parts Replace parts not found to be in satisfactory condition ACCURACY VERIFICATION AND MINOR CALIBRATION PROCEDURE This procedure is to be used to check the accuracy and if necessary pe
7. rench within the accuracy limits Page 7 3 Replace the cone nut and tighten counterclockwise Then tighten the cone nut to 803 IN LB eL Uhh a i P l f fil j PERN ur al OR Page 8 How to check the Spherical Ball Placement NOTE If the torque screwdriver jams or does not turn the spherical balls can be the problem Follow steps 1 through 7 to check and or replace the spherical balls 1 Usea 74 open end wrench turning it clockwise to loosen and remove the cone nut 2 Turn the cone counterclockwise to the remove from cone from the screwdriver 3 Remove the cam from the screwdriver Page 9 4 Inspect the secondary cam to assure that the spherical balls 2 are in place in the secondary cam If they are not grease lightly to hold them in the secondary cam 5 Grease the cam 6 Place the cam into the cone and screw into place Page 10 7 Perform a major calibration adjustment to bring the screwdriver within the accuracy limits or a minor adjustment could be used to bring the wrench within the accuracy limits How to re engage the knob 1 If the knob becomes disengaged Line up the decagon on the knob with the decagon on the inside of the screwdriver Apply a force until the knob re engages 2 Perform a minor calibration adjustment to set the low reading Calibration Instructions for a Pre Set CDI Screwdriver 1 Remove the plug from the end of the knob
8. rform a minor adjustment on calibration It must also be used after a major calibration There are two major international standards that establish torque wrench accuracy requirements They are ASME B107 14 Hand Torque Tools American Society of Mechanical Engineers and ISO 6789 Hand Torque Tools Requirements and Test Methods International Organization for Standardization Both standards are recognized as established accuracy test methods and referenced in this section ASME and ISO standards are subject to review and changes The repair manual will be reviewed and revised periodically but may not reflect the latest revisions of the specifications listed above ASME B107 14 Preload the wrench by setting the wrench at 100 of full scale and operating three times on the tester 2 Reset handle to 20 of full scale Take 3 readings at 20 3 Set and test the wrench three 3 times at 60 and 100 of full scale noting the accuracy error for each reading If the readings are within the accuracy requirements for the direction 4690 or readings no calibration adjustment is required ISO 6789 1 Preload the wrench by setting the wrench at 100 of full scale and operating five 5 times in the direction of the test 2 Reset handle to 2095 of full scale 3 Test the wrench five 5 times at 2096 noting the accuracy error for each reading Set and test the wrench five 5 times at 60 and 100 of full scale noting the accuracy error f

Download Pdf Manuals

image

Related Search

Related Contents

  Miele W 3164  KitchenAid KECC056RBL04 User's Manual  Guide de démarrage de SafeGuard Easy.  RG_INF_IN2128HDa_Portuguese Brazil.book  User Manual - Express Cleaning Supplies  Manual - Texas  Epson 3600e Quick Setup Guide  Neigungssensor Typ N3... / N4... / Tilt sensor type N3... / N4  Componenti per Automazione_Catalogo di gamma  