Home

Campaver - Installation and Operating Instructions - Issue 1

image

Contents

1. xX lt Dimplex Campaver Bathroom Radiator Model No s CMV1200B W R CMV1600B W R Installation and Operating Instructions July 2006 lssue 2 T E Dimensions mm Model Height A Width rails B Depth rails C CMV1200B 1202 352 54 113 67 CMV1600B 1502 427 54 113 67 CMV1200W 1202 352 54 113 67 CMV1600W 1502 427 54 113 67 CMV1200R 1202 352 54 113 67 CMV1600R 1502 427 54 113 67 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE WARNING This product must be installed by a competent person or electrician in conjunction with the current IEE Wiring Regulations and relevant Building Regulations When using electrical appliances basic precautions should always be followed to reduce risk of fire electrical shock and injury to persons including the following WARNING THE SURFACES OF THIS HEATER CAN BE HOT Momentary contact with any part of the heater should not cause injury However aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted This appliance is not intended for use by children or other persons without assistance or supervision if their physical sensory or mental capabilities prevent them from using it safely e DO NOT cover or obstruct the air inlet or air outlet vents only
2. Operation The Campaver incorporates simple to use electronic controls to provide maximum comfort and energy saving benefits Radiant Heat 1 Press the ON OFF switch to the T position see Fig 4 A 2 Turn the thermostat dial E see Fig 5 clockwise to the maximum setting the neon indicator F will light to show the front panel is starting to heat 3 Once the desired room temperature is achieved turn the thermostat dial slowly anti clockwise until the indicator F is no longer lit and the radiator will automatically maintain the set temperature 4 The thermostat dial E offers a frost protection setting Turn the thermostat dial ant clockwise to the X symbol and the radiator will automatically maintain a room temperature of 7 C 3 C Fan boost and runback timer For additional room heat or rapid towel drying the Campaver bathroom radiator incorporates a runback timer controlled fan boost NOTE The fan boost will only operate with the runback timer control Fan boost and runback timer 1 Press the runback timer dial C the digital display B will show a preset time of 20 minutes and the fan boost will start to blow hot air from the front base of the radiator upwards 2 To adjust the amount of time you want the fan boost to run turn the runback timer dial anti clockwise to decrease the time and clockwise to increase the time 0 120 minutes maximum 3 The digital display will countdown from the time selected to zero
3. and glass cleaner solution After Sales Service Your product is guaranteed for two years from the date of purchase Within this period we undertake to repair or exchange this product free of charge subject to availability provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales service you should contact our customer services help desk on 0870 727 0101 It would assist us if you can quote the model number date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service Please retain your receipt as proof of purchase Glen Dimplex UK Ltd Customer Help Line Millbrook House Tel 0870 727 0101 8am 6pm Mon Fri 8 30am 1pm Sat Grange Drive Fax 0870 727 0102 Hedge End E mail customer service glendimplex com Southampton Web site www dimplex com Republic of Ireland Tel 01 842 4833 C Glen Dimplex UK Limited All rights reserved Material contained in this publication may not be reproduced in whole or part without prior permission in writing from Glen Dimplex UK Limited
4. use the towel hangers for drying airing towels DO NOT recess the unit in to a wall as this will cause overheating and potentially be a fire risk The wall bracket provided must be used for installation DO NOT use outdoors DO NOT locate the radiator immediately below a fixed socket outlet or connection box This radiator is IP24 rated and therefore can be installed in a bathroom but must be located so switches and other controls cannot be touched by a person using a bath or shower Technical Specification Model Radiant Output W Fan Output W Voltage CMV1200W 600 600 230V AC CMV1600W 1000 600 230V AC CMV1200B 600 600 230V AC CMV1600B 1000 600 230V AC CMV1200R 600 600 230V AC CMV1600R 1000 600 230V AC General Principle The Campaver range of bathroom radiators combine the use of multiple radiant element technology with an innovative and stylish use of glass to provide the perfect balance of radiant and convected heating for optimum comfort The highly efficient aluminium radiant element and thin surface heating film work together to provide rapid warm up and even heat distribution across the surface of the glass The Campaver range also incorporates a fan boost controlled by a runback timer which overrides the thermostat setting for powerful room heating and rapid towel drying Location All Campaver radiators should be installed by an electrician or competent person in strict accordance with the current IEE Wiring Regulati
5. Once the digital display reaches zero the fan boost will automatically switch off 4 To switch off the fan boost manually press the runback timer dial C 5 To save the desired time setting for the runback timer press and hold the runback timer dial C for 3 seconds When the runback timer is switched off and on again the digital timer will display the new run back time as its default setting NOTE When the runback timer is activated all three heat sources both radiant elements and fan boost will operate at maximum heat output and will override the thermostat setting until the runback timer reaches zero HASN y Co Run back timer countdown display B D Lf Run back timer control dial G Filter saturation indicator D Thermostat dial radiant heat only E Heating indicator F Fig 4 Operation Contd Pilot wire control Unscrew the metal receiver sleeve from the back of the radiator see Fig 6 NOTE Do NOT remove the receiver sleeve if a slot in programmer is not to be used c or RXPW4 Pilot Wire 4 zone controller no receiver required Mode Comfort On Background Setback Off Frost protection sleeve RX9911 Single zone Pilot Wire programmer Rear view or Fig 6 RXMBS4 RX9913 Mains BorneSignalling Mains Borne Signalling Receiver 4 zone controller Function Radiant Elements Only Heater functions at thermostat setting Heater functions at 3 5 C below thermost
6. at setting No heat output Heater functions at 7 C 3 C NOTE Pilot wire and MBS controllers only control the radiant elements If the runback timer is in use the fan boost will continue to run regardless of the mode selected Please also refer to individual instructions for programmers and receivers Assembly of towel rail s 1 Place the rail above the radiator and push firmly in to the two slots at the rear of the radiator there are three sets of slots for different height options see Fig 7 Filter Cleaning the filter When the filter requires cleaning the Filter neon indicator will light see Fig 10a 1 First turn the child lock knob anti clockwise 1 and lift the knob upwards 2 see Fig 8 2 Gently pull the right hand side of the radiator outwards see Fig 9 3 Slide out the filter towards you see Fig 9 4 Wash the filter in warm soapy water and replace 5 Ensure the child lock is engaged see also Fig 4 in the Installation section on page 2 Fig 10a N S o Saturation indicator i E a Front view Rear view Side view Fig 10b Fig 8 Fig 9 Cleaning IMPORTANT o Never clean the appliance whilst it is hot always allow the product to cool sufficiently e Do NOT use abrasive cleaning products Always wait for the appliance to dry before switching it on again Clean the casing of the product with a sponge and soapy water Clean the glass front panel with a soft cloth
7. nd turn clockwise 2 until tight to lock in position see Fig 4 lt SHELF 160 A Fig 1 Fig 2 E poeet gt PA Eee H M EPERE i O A Ca ad Fig 3 Fig 4 Dimensions Model Dimensions in mm A B C D E F G CMV1200W 1202 352 140 265 106 514 265 CMV1600W 1502 427 215 505 106 514 325 CMV1200B 1202 352 140 265 106 514 265 CMV1600B 1502 427 215 505 106 514 325 CMV1200R 1202 352 140 265 106 514 265 CMV1600R 1502 427 215 505 106 514 325 Electrical Connection Please also refer to IMPORTANT SAFETY ADVICE on page 1 IMPORTANT If the appliance is NOT connected to a pilot wire controller isolate the black pilot wire The wires in the mains lead are coloured in accordance with the following code N Neutral grey L Live brown E Earth yellow green P Pilot Wire black Pilot Wire Connection IMPORTANT Do NOT connect the pilot wire to earth Care should be taken with the installation of the pilot wire s as when switching to background setback they become energised at 240V although only at a current of 1mA In every case a suitable means of isolation must be provided for the pilot wire and marked to indicate that two sources of supply may be present at the heater Where pilot wires are installed separately from the heater final sub circuit they should be protected double insulated and carry their own integral earth continuity conductor Note Pilot wire installations are appropriate for single phase connection only
8. ons and relevant Building Regulations Class 1 appliances UK amp Northern Ireland installations All Campaver radiators are IPX4 rated and can therefore be installed in Zone 2 of a bathroom These appliances are NOT suitable for installation in Zone 0 or Zone 1 see Fig 2 Republic of Ireland installations All Campaver radiators are IPX4 rated and can therefore be installed in Zone 3 of a bathroom These appliances are NOT suitable for installation in Zone 0 Zone 1 or Zone 2 see Fig 2 Ceiling OUTSIDE ZONES zones 7 a and am I Fig 2 Current Amps Weight kg Casing Finish Glass Finish 5 16 White White 7 22 White White 5 16 Black Black 7 22 Black Black 5 16 White Mirror 7 22 White Mirror Installation WARNING This product must be installed by a competent person or electrician in conjunction with the current IEE Wiring Regulations and relevant Building Regulations The Campaver bathroom radiator must be wall mounted as follows 1 Make sure the minimum clearances are adhered to Fig 1 and Fig 2 2 Place the wall bracket on the wall making sure it is the correct way up and mark the relevant fixing points 3 Drill the holes and secure the wall bracket with the appropriate fixing type for the wall 4 Using the 6 vertical hooks on the wall bracket place the radiator over the hooks 1 and pull downwards to secure 2 see Fig 3 D Pull the child lock knob downwards 1 a

Download Pdf Manuals

image

Related Search

Related Contents

EVEREST U1008 Instructions / Assembly  2P/2P 6~10KVA Online UPS User Manual  Groupes 2013 - Domaine des Grottes de Han  Multi-Function Power Monitor User Manual  HP ENVY 6-1200ea  FRANÇAIS  IMPORTANTE!  KBDA Series Installation & Operation Manual  20110815 Mayfair EULA for ImageWay  アマチュア局の非常通信マニュアル(pdf)  