Home
Bedienungsanleitung de Operating instructions en Mode d
Contents
1. Elektrowerkzeuge Hiltistrasse 6 86916 Kaufering Deutschland iL Ti Hilti Corporation LI 9494 Schaan Tel 423 234 21 11 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3154 1013 00 Pos 1 1 Printed in Germany 2013 Right of technical and programme changes reserved S E amp O 274258 A2
2. be completed Repeat the measuring operation constantly correctly Small red LED right lights con The wrong filter is selected Check and correct the filter setting stantly Large red and small red LED The PT 10 quick check device and or Repeat the measuring operation left light constantly the laser tool under test was shaken during measuring Large red and green LED light Camera error Remove the PTA 10 optical level and constantly despite several return it to a Hilti service center for measuring attempts repair 10 Disposal WARNING Improper disposal of the equipment may have serious consequences The burning of plastic components generates toxic fumes which may present a health hazard Batteries may explode if damaged or exposed to very high temperatures causing poisoning burns acid burns or environmental pollution Careless disposal may permit unauthorized and improper use of the equipment This may result in serious personal injury injury to third parties and pollution of the environment Most of the materials from which Hilti tools and appliances are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrangements for taking back old tools and appliances for recycling Ask Hilti customer service or your Hilti representative for further information For EC countries only Do not dispose of electrical appliances together with househol
3. conformity original 18 El These numbers refer to the corresponding illustra tions The illustrations can be found on the fold out cover pages Keep these pages open while studying the oper ating instructions In these operating instructions the designation the tool always refers to the PT 10 quick check device Component parts El On button Mains plug 3 Calibration switch Adjusting screws Beam search fine adjustment Bubble level PTA 10 optical level with camera Filter unit Operating unit PTA 70 tripod adapter PTA 45 tripod head PTA 40 tripod column Rear cover Concrete base Table of Hilti tools Screw feet Crank 18 Disc or accessory QBQOOQOEOOESOOEOOOEHOELOOO o ne o i S gt a c 3 Power indicator Aim laser beam at center of filter Accuracy class selector button Filter selector Beam on camera indicator Start measuring Laser tool within specified tolerance 8 Laser tool not within specified tolerance 9 Laser tool moved during measuring 10 Check filter and or accuracy class settings ASS 1 General information 1 1 Safety notices and their meaning DANGER Draws attention to imminent danger that will lead to serious bodily injury or fatality WARNING Draws attention to a potentially dangerous situation that could lead to serious personal injury or fatality CAUTION Draws attention to a potentially dangerous situation that could lead to slight person
4. falling and injury d Use the tool only within its specified limits 5 3 Electromagnetic compatibility Although the tool complies with the strict requirements of the applicable directives Hilti cannot entirely rule out the possibility of the tool being subject to interference caused by powerful electromagnetic radiation leading to incorrect operation Check the accuracy of the tool by taking measurements by other means when working under such conditions or if you are unsure Likewise Hilti cannot rule out the possibility of interference with other devices e g aircraft navigation equipment Bu 6 1 Setting up the tool 1 Check that the surface of the table or bench is flat and that it stands level 2 Place the concrete base on a sturdy table or bench if the PTA 30 is used assemble and secure this table first NOTE Version without PTA 30 table Use an open end wrench to adjust the screw feet so that the bubble of the bubble level on the tripod adapter is inside the inner ring Tighten all lock nuts on the screw feet securely 14 3 Position the flat surface of the concrete base so that the hole for the tripod column lies beyond the edge of the table NOTE Please observe the safety rules in the section Proper organization of the work area 6 1 1 Fitting the tripod column EJ El A 1 Fit the tripod column through the hole in the concrete base from below and secure it with the screws NOTE Please note that cr
5. light The laser beam is not striking the cam era Check that the Hilti laser tool is switched on Only one yellow LED lights The laser beam is striking the camera only partially Use the fine adjustment screws to rotate the optical level until both yellow LEDs light constantly Both LEDs light constantly Both yellow LEDs blink The laser beam is striking the camera and the tool is ready to begin measur ing Information displayed while measuring is in progress Large green and red LEDs The green LED lights The red LED lights 2 5 PT 10 quick check device in cardboard box items supplied PT 10 quick check device PTA 70 tripod adapter PTA 45 tripod head PTA 40 tripod column Disc or accessory Mains adaptor Operating instructions A A oa a an an an a Manufacturer s certificate 2 6 PT 10 associated items in separate box 1 PTA 10 optical level with camera 2 7 PT 10 associated items in Hilti toolbox 1 PTA 20 calibration tool 1 Mains adaptor Result of test The laser tool under test is within the specified accuracy Result of test The laser tool under test is not within the specified accuracy and must be returned to a Hilti service cen ter for calibration 1 Operating instructions 1 Manufacturers certificate 2 8 PT 10 quick check device set in cardboard box items supplied PT 10 quick check device PTA 30 table PTA 70 tripod adapter PTA 45 tripod head PTA 40 tripod
6. 7 1 1 Mounting point lasers rotating lasers or multidirectional lasers on the tripod adapter El Screw the PTA 70 tripod adapter onto the tripod head 2 Place the Hilti laser tool under test on the adapter plate and switch it on 3 Use the crank to adjust the height of the Hilti laser tool so that the laser beam is aimed at the center of the crosshairs in the middle of the filter disc a 7 1 2 Mounting the laser tool on the adapter plate for the PP 10 and PP 11 pipe lasers Screw the PPA 73 tripod adapter onto the tripod head 2 Place the pipe laser on the tripod adapter and switch it on 3 Use the crank to adjust the height of the Hilti laser tool so that the laser beam is aimed at the center of the crosshairs in the middle of filter disc 7 1 3 Switching on Switch on the PT 10 quick check device 7 2 Setting the accuracy class 1 Select the applicable accuracy class 1 9 according to the table of Hilti tools 2 Press the buttons until the corresponding accur acy class appears 7 3 Filter setting 1 Select filter setting or Il according to the table of Hilti tools 2 Move the switch on the filter disc to the correspond ing position 7 4 Adjusting the camera The position of the laser beam on the camera lens is indicated by the yellow LEDs If neither of the yellow LEDs light up or only one LED lights turn the fine adjustment screw on the optical level until the laser beam is found Both yellow LE
7. Ds light up as soon as the laser beam strikes the camera At the same time the Start meas uring button becomes active and the device is ready to begin the test 7 5 Measuring NOTE Do not touch or move the PT 10 quick check device while measuring is in progress An error message will be displayed in the event of vibration The PT 10 quick check device is ready to begin meas uring as soon as both yellow LEDs light and the Start measuring button is shown to be active Press the Start measuring button The measuring op eration is indicated by the yellow LEDs blinking and continues on average for approx 50 seconds 7 6 Indication of result NOTE All 4 directional axes X Y of rotating lasers must always be tested After measuring for approx 50 seconds either the green or the red LED lights to indicate whether the laser tool under test is within the specified accuracy If the green LED lights the laser tool is within the specified accuracy If the red LED lights the laser tool is not within the specified accuracy and should be returned to a Hilti service center for calibration 7 7 Repeating the test procedure NOTE The test procedure can be repeated with each Hilti laser tool as often as desired 7 8 Calibration NOTE Monitoring of measuring equipment for users certified in accordance with ISO 9000X The required procedure for monitoring the PT 10 quick check device within the scope of ISO 900X c
8. al injury or damage to the equipment or other property NOTE Draws attention to an instruction or other useful informa tion 1 2 Explanation of the pictograms and other information Warning signs General warning Symbols Location of identification data on the tool The type designation and serial number can be found on the type identification plate on the tool Make a note of this data in your operating instructions and always refer to it when making an enquiry to your Hilti representative or service department Read the Disposal of operating power tools instructions or Type before use appliances and batteries together with Serial no household waste is not permissible 2 Description 2 1 Use of the product as directed The PT 10 is a quick check device that allows a single person to quickly and accurately check whether the accuracy of a Hilti rotating laser point laser or line laser is within the specified tolerance The accuracy of the horizontal laser beam is checked in each case NOTE Important Only Hilti laser tools featuring a visible laser beam can be tested 2 2 Features This device allows the user to test the laser tool quickly and easily takes approx 50 seconds Operation of the device is self explanatory and the result obtained is clear and unequivocal The PT 10 is compact and robustly built The accuracy of the following Hilti laser tools can be checked PML 32 PML 32 R PML 42 PM 2 L line la
9. an be carried out by the owner The PTA 20 a tool specially designed for the purpose of calibrating the PT 10 quick check device is available from Hilti Please contact Hilti Customer Service for information about the availability of this item 7 8 1 Calibrating the PT10 quick check device El E Y E E A 2 NOTE Calibration should be carried out at regular intervals The PTA 20 calibration tool to be used for calibrating the PT 10 quick check device is available from Hilti The calibration tool should be sent to a Hilti service center in advance for checking and calibration 1 Mount the calibration tool on the tripod adapter of the PT 10 15 2 Plug the supply cord of the calibration tool into the power outlet 3 A message appears in the display and the present accuracy deviation is shown The calibration se quence number is also shown The calibration se quence number increases by one after each suc cessful calibration of a PT 10 quick check device 4 Check the bubble level of the optical level again and correct the level if necessary by turning the optical level adjusting screws Switch on the PT 10 quick check device 6 Use the tip of a pointed object such as a ball point pen to press the calibration switch 16 on the panel at the rear of the device The small red LED on the right lights indicating calibration mode 18 7 Select filter setting Il The accuracy class does not have to be selected 8 Turn the cr
10. ank must be positioned toward the front 2 Fit the tripod head onto the tripod column 3 Screw the PTA 70 tripod adapter onto the tripod head Rotate the tripod adapter until the designation PTA 70 can be read from the front and then use the hex socket wrench supplied to tighten the screw 6 a 2 Fitting the optical level Unscrew the two wing screws and open the rear cover on the concrete base 2 Place the PTA 10 optical level on the raised part of the concrete base and secure it with the adjusting screw provided NOTE Take care to ensure that the filter unit is directed toward the tripod head 3 Close the rear cover on the concrete base and tighten the two wing screws a 6 1 3 Electrical connections El 1 Connect the cable from the PTA 10 optical level to the connector on the rear of the concrete base 2 Connect the supply cord to the rear of the concrete base 3 Plug the supply cord into the power outlet 6 1 4 Setting up the PT 10 quick check device in the horizontal plane A El NOTE The PT 10 must be set up in the horizontal plane before use First use the bubble level on the tripod adapter as a reference and then the bubble level incorporated in the optical level The bubbles of both levels must be centered in the inner circle before the tool can be used for measuring Calibrate the PT 10 quick check device before use 7 Operation Bu 7 1 Mounting the laser tool on the tripod adapter
11. ank to adjust the height of the PTA 20 calibration tool 16 so that the laser beam emitted is aimed at the center of the crosshairs on the PT 10 quick check device The position of the laser beam on the camera lens is indicated by the LEDs 9 Turn the fine adjustment screw 17 on the PTA 20 until the display shows zero NOTE The direction in which the fine adjustment screw should be turned is indicated by the two ar rows in the display The arrows at the beginning of the line indicate the direction in which the fine adjust ment screw should be turned and the subsequent digits indicate the present deviation inclination in arc seconds and arc minutes 10 Both yellow LEDs light up as soon as the laser beam strikes the camera At the same time the Start measuring button becomes active and the device is ready to begin the test 11 If neither of the yellow LEDs 19 20 light up or only one LED lights turn the fine adjustment screw on the optical level until the laser beam is found 12 Press the Start measuring button 21 The meas uring operation is indicated by the yellow LEDs blink ing and continues for a maximum of 50 seconds NOTE Do not touch or move the PTA 20 calibration tool or the PT 10 quick check device while measuring is in progress An error message will be displayed in the event of vibration The green LED lights after successful calibration and the PT 10 returns to normal operating mode The smal
12. column Disc or accessory Mains adaptor Operating instructions 422000200 Manufacturer s certificate 2 9 PT 10 set associated items in separate box 1 PTA 10 optical level with camera 2 10 PT 10 set associated items in Hilti toolbox PTA 20 calibration tool Mains adaptor Operating instructions Lo Manufacturer s certificate 3 Accessories Designation PP tripod adapter for pipe laser Tripod adapter Table for PT 10 Disc or accessory Mains adaptor Table of Hilti tools Description PPA 73 PTA 70 PTA 30 PTAW 80 PTAW 10 4 Technical data Right of technical changes reserved Measuring time in seconds Max 50 Operating status indicators LED Power supply DC voltage 6 V 0 2 A Operating temperature range 10 35 C Storage temperature 0 50 C Protection against dust and water spray IP 54 protection against dust and water spray Tripod thread BSW Weight 36 4 kg Dimensions 600 mm X 190 mm X 520 mm 5 Safety instructions WARNING Read all safety instructions and other in structions Failure to observe the safety precautions and instructions may result in electric shock fire and or seri ous injury Keep all safety precautions and instructions for future reference 5 1 General safety rules a Check the condition of the tool before use If the tool is found to be damaged have it repaired at a Hilti service center b The tool must be c
13. d waste In observance of the European Directive on waste electrical and electronic equipment and its implement ation in accordance with national law electrical appliances and batteries that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility 17 11 Manufacturer s warranty tools Hilti warrants that the tool supplied is free of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instructions and the technical system is main tained This means that only original Hilti consumables components and spare parts may be used in the tool This warranty provides the free of charge repair or re placement of defective parts only over the entire lifespan of the tool Parts requiring repair or replacement as a result of normal wear and tear are not covered by this warranty Additional claims are excluded unless stringent na tional rules prohibit such exclusion In particular Hilti is not obligated for direct indirect incidental or con sequential damages losses or expenses in connec tion with or by reason of the use of or inability to use the tool for any purpose Implied warranties of merchantability or fitness for a particular purpose are specifically excluded For repair or replacement send the tool or related parts i
14. eile PT 10 Bedienungsanleitung Operating instructions Mode d emploi Manual de instrucciones Istruzioni d uso Gebruiksaanwijzing Brugsanvisning Bruksanvisning Bruksanvisning K ytt ohje Manual de instru es ERSTE Hasznalati utasitas N vod k obsluze N vod na obsluhu Instrukcja obs ugi Upute za uporabu Navodila za uporabo PbKOBOACTBO 3a O6CNYMBAHE MHCTPyKUMA NO skcnnyaTaynn MRE MBAS ce U Im UN Printed 15 11 2013 Doc Nr PUB 5161904 000 00 al Printed 15 11 2013 Doc Nr PUB 5161904 000 00 ORIGINAL OPERATING INSTRUCTIONS PT 10 quick tester It is essential that the operating instructions are read before the tool is operated for the first time Always keep these operating instructions to gether with the tool Ensure that the operating instructions are with the tool when it is given to other persons Contents Page 1 General information 10 2 Description 11 3 Accessories 13 4 Technical data 13 5 Safety instructions 14 6 Before use 14 7 Operation 15 8 Care and maintenance 16 9 Troubleshooting 7 10 Disposal 17 11 Manufacturer s warranty tools 18 12 FCC statement applicable in US IC statement applicable in Canada 18 13 EC declaration of
15. hecked at a Hilti service center after it has been dropped or subjected to other mechanical stresses c The tool is intended exclusively for indoor use d Before operating the tool check that it is com plete and standing or secured in a stable position e The tool and its ancillary equipment may present hazards when used incorrectly by untrained per sonnel or when used not as directed f Have the tool repaired only at a Hilti service cen ter g To avoid the risk of injury use only genuine Hilti accessories and additional equipment h Modification of the tool is not permissible i Observe the information printed in the operat ing instructions concerning operation care and maintenance 6 Before use j Do not render safety devices ineffective and do not remove information and warning notices k Keep laser tools out of reach of children Take the influences of the surrounding area into account Do not use the tool where there is a risk of fire or explosion m Only laser tools featuring a visible laser beam may be checked using the PT 10 quick check device 5 2 Proper organization of the work area a Secure the working area and take care to ensure that the surface of the bench or table is steady and level when setting up the tool b Ensure that the tool is set up on a steady level surface not subject to vibration c Do not set up the tool at a passageway or where people frequently pass by risk of tripping
16. l red LED on the right goes out a 8 Care and maintenance 8 1 Cleaning and drying 1 Blow dust off the lenses 2 Do not touch the glass or the filter with the fingers 3 Use only a clean soft cloth for cleaning If necessary moisten the cloth slightly with pure alcohol or a little water NOTE Do not use any other liquids as these may damage the plastic components 4 The temperature limits for storage of your equipment must be observed especially in winter summer 8 2 Storage Remove the appliance from its case if it has become wet The tool its carrying case and accessories should be cleaned and dried at maximum 40 C 104 F Repack the equipment only once it is completely dry After a long period of storage check the calibration of the tool before use 8 3 Transport Use the Hilti shipping carton the Hilti shipping case or packaging of equivalent quality for transporting or shipping your equipment 9 Troubleshooting Fault Possible cause Remedy The PT 10 can t be switched on The supply cords are not or not fully Check the supply cord and ensure connected that all cords are connected correctly The PT 10 can t find the laser The laser beam is not aimed at the Aim the laser beam at the crosshairs beam crosshairs The laser tool is not switched on Switch the laser tool on Not a Hilti laser tool Only genuine Hilti laser tools can be tested Large red and green LEDs light Measuring could not
17. mmediately upon discovery of the defect to the address of the local Hilti marketing organization provided This constitutes Hilti s entire obligation with regard to warranty and supersedes all prior or contemporaneous comments and oral or written agreements concerning warranties 12 FCC statement applicable in US IC statement applicable in Canada This device complies with part 15 of the FCC rules and with CAN ICES 3 A NMB 3 A Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received in cluding interference that may cause undesired operation NOTE Changes or modifications not expressly approved by Hilti may restrict the user s authorization to operate the equipment 13 EC declaration of conformity original Designation Quick tester Type PT 10 Year of design 2006 We declare on our sole responsibility that this product complies with the following directives and standards 2011 65 EU 2006 95 EC 2004 108 EC EN ISO 12100 Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan dy E Paolo Luccini Head of BA Quality and Process Man agement Business Area Electric Tools amp Ac diba p Matthias Gillner Executive Vice President Business Area Electric cessories 01 2012 Tools amp Accessories 01 2012 Technical documentation filed at Hilti Entwicklungsgesellschaft mbH Zulassung
18. sers PM 10 PM 24 PMP 34 PMP 45 point lasers PR 10 PR 15 PR 16 PR 20 PR 25 PR 26 PRE 3 PR 35 PRI 36 PR 2 HS PR 30 HVS rotating lasers PP 10 PP 11 PP 25 pipe lasers Plus new Hilti leveling and alignment lasers visible beam type from future product generations 2 3 Settings in accordance with the table of Hilti tools Hilti laser tool Accuracy class Filter setting PM 10 PM 24 PMP 34 PMP 45 9 Il PML 32 PMC PMM 9 PP 1 Il PR 10 PR 15 5 PR 16 PRI 2 PRI 36 3 PR 20 PR 28 PRE 3 PRE 38 PR 2 HS 1 PR 25 PR 26 PR 35 PR 3 PR 30 HVS 2 The table of Hilti tools will be updated and replaced when new products are introduced 11 2 4 Information displayed during operation Small green LED The green LED doesn t light The green LED doesn t light The tool is switched off The tool is not connected to the electric supply The green LED lights con stantly Beam search for the laser beam from the tool under test is active After searching in beam search mode unsuccessfully for 2 minutes the PT 10 quick check device reverts automatically to standby mode The green LED blinks Ready mode Small yellow LED The yellow LED doesn t light The laser beam is not aimed at the opening in the filter unit and therefore not at the camera Use the fine adjustment screws to rotate the optical level until both yellow LEDs light constantly The yellow LED doesn t
Download Pdf Manuals
Related Search
Related Contents
MCI500H/05 Philips Wireless Micro Hi-Fi System Dokumentation Samsung Galaxy Tab A com S Pen 9.7" Wi-Fi manual do usuário MANUEL DE L`UTILISATEUR DE L`E-ICON JT Paintball se réserve Acronis True Image Enterprise Server 9 SelEstim version 1.1.4 User Manual Les mesures pour l`emploi, mode d`emploi Lincoln Electric IM723-A User's Manual Copyright © All rights reserved.
Failed to retrieve file