Triton Aqua Pump Operating Instructions

image

Contents

1. breaker for outside use We recommend you should use one for inside use too Specification Discharge Bore 40mm Max Head 7m Max Capacity 240 litres min 1m Motor Output 1 3 Hp Width 164mm Height 352mm Length 236mm Voltage 230v Fuse rated 5 0amp Pump installation Insert the TRITON AQUA PUMP MAS 250V in the base of the sump basin and connect the water discharge pipe to the flexible coupling already attached to the pump The discharge end of the pipe can be taken through a wall and extended to a gully outlet at ground street level Alternatively the discharge pipe can be connected straight into a soil pipe using a boss connection Where a double pump installation is being used Aqua Pump Plus each pump must be wired into an independent fused spur outlet One of the Aqua Pumps the secondary pump in the double pump kit must be fitted with 25mm leg extensions at the base of the pump so that this pump is raised off the bottom of the sump basin Connect the wires from the float switch sensor to the wires of the water alarm using the bullet connectors provided Then connect the pump s power cable into a fused spur outlet fuse rating Samp and test the pump and alarm for working order Pump operation The pump is positioned within the Sump Basin and is controlled by an automatic snap action tube float switch As the water level increases within the sump the float rises and when the pre set switch lev
2. ION Triton Aqua Pump Model MAS 250V Operating Instructions Triton Systems Units 3 5 Crayford Commercial Centre Greyhound Way Crayford Kent DA1 4HF www tritonsystems co uk info tritonsystems co uk tel 01322 318830 fax 01322 524017 Introduction TRITON AQUA PUMP SYSTEM System overview The TRITON AQUA PUMP SYSTEM is a ready to use complete water control system principally designed for use in below ground structures to control water ingress The system consists of a pre formed polyethylene sump basin a mains powered 230v submersible pump a non return valve assembly and a battery operated high water level alarm which is linked to an integral float switch The system can be linked to TRITON AQUA CHANNEL see Triton Agua Channel Data to manage water ingress from retaining walls and in turn pumping out to a suitable drainage point TRITON AQUA PUMP MAS250V Pump description The TRITON AQUA PUMP MAS 250V is a strong and efficient pump in 304 stainless steel and thermoplastic Excellent flow and head are produced from an energy efficient 250 watt motor The close compact positioning of the integral tube float switch and rubber feet ensure that this pump can work quietly in confined spaces ensuring it is particularly suited to basement and cellar applications Long term trouble free operation is enhanced with an integral vent valve to prevent air locking The 410 stainless steel shaft incorporates a hardwearing mechani
3. cal seal and an oil seal within an oil chamber and a semi vortex thermoplastic impeller Each pump is supplied with 1 one set of 3 leg extensions for assist duties high level alarm twin pump systems 2 1x50mm to 32mm reducing nipple 3 1x 32mm non return valve 4 5 metres of heavy duty rubber power cable The TRITON AQUA PUMP MAS 250V must only be used for pumping ground water The pump should not be used to pump grey water from sinks washing machines dishwashers condensing boilers or effluent Triton Chemical Manufacturing Co Ltd will not accept responsibility or liability for pump failure or damage caused due to the misuse of the pumping system E Q mula D ep PPPPPPPE PEE Read all instructions before use Keep all pump equipment away from the reach of children These pumps are not suitable for pumping salt water corrosive explosive or flammable liquids petrol thinners Do not modify the pump in any way Do not operate the pump if anyone is in the water liquid you are pumping Do not lift or carry the pump by the power cable or float cable Before taking action of any kind on the pump make sure it is disconnected from the power supply Do not operate or connect to a power supply if there are any signs of damage to the pump or the power cable Do not try to disconnect the power cable plug from the mains by pulling on the power cord 17th edition regulations states you must always use a power
4. el is reached the pump will automatically operate and discharge the water The Pump is 230v and requires wiring into an independent fused spur outlet within 1 5m of the pump Non return valve assembly To avoid any discharged water backing up into the sump basin a non return valve assembly is provided This is fitted to the submersible pump with the supplied reducing nipple Care should be taken that the rubber flap valve opens in the direction of the pipe i e away from the pump The valve will accept a standard 40mm waste pipe Pump maintenance The TRITON AQUA PUMP MAS 250V has 1 year guarantee from the date that it is installed A further 2 years is given taking the guarantee up to 3 years if the pump is maintained serviced at a minimum every six months This should be carried out by a competent contractor under a maintenance contract During a service all parts of the kit should be checked to ensure fully operational The sump should be cleared of any silt sludge that may have accumulated to avoid potential damage to the pump s The sump must be filled with water to ensure the automatic float switch and pump are fully operational Any defective or worn parts must be replaced repaired to avoid failure of the whole system Example of suitable sump pump and drainage schedule can be found in the Isola manual or downloaded from the Triton website below www tritonsystems co uk Records must be kept of each service be kept by the propert
5. etting or roding the outlet pipe Clear and wash away any blocking debris Un kink outlet pipe Start and stop pump several times and or check for clogged vent hole in pump case Remove pipe and inspect non return valve clear or fit other way Unblock by jetting or roding Un kink outlet pipe Clear and wash away any blocking debris Reduce head or length of outlet pipe or increase diameter of outlet pipe Check for any obstructions to float and clear them Contact your supplier Casing can be removed and debris cleared Warranty is offered for a period of one year from date of purchase or 3 years if serviced every 6 months and covers failure of equipment due to faulty components or assembly Warranty covers parts and labour only and excludes any carriage charges to the supplier s works Fair wear and tear and mis use are excluded from any warranty Triton Systems reserves the final decision regarding validity of any claim Customers shall not attempt any repair or adaptation to equipment during the warranty period or use the equipment for any purpose other than for which it was designed Any such interference or mis use will negate any claim for warranty Declaration of Conformity Product MAS 250V Manufacturer Hung Pump Industrial Co Ltd Address 16 Lian Ming Street Ba de City Taoyuan Taiwan 334 R O C Imported by UK Agents of Hung Pump Industrial Ltd for Triton Chemical Manufacturing Compan
6. l CA CE Ring 14 Sleeve SUS304 34 Packing NER l5 Oil Seal NER Aa 10 r 4 OOIE a NES e 7 A3 SS RS Se pal 13 Trouble shooting Pump will not run circuit breaker trips fuse blows Pump runs but no liquid is delivered Insufficient flow rate Pump will not switch off Pump is vibrating excessively amp or is noisey Warranty Faulty or switched off power supply Fault or break in the power cable or float cable Water level not deep enough to activate float Blocked impeller pt no 7 Motor protector may be operational Fuse rating too small Defective motor Blockage in the outlet pipe Blockage of inlet of pump casing Outlet pipe kinked Pump is air locked Non return valve stuck or wrong way round Debris blocking outlet pipe Outlet pipe kinked Blockage of inlet of pump casing Too much head outlet pipe too long or diameter too small Float maybe obstructed and unable to return to an off position Motor bearings pt no 11 amp 12 are damaged Loose debris in the pump casing pt no 8 9 e Check power supply Inspect the cable for any damage If damage is found do not attempt to run the pump Wait for water level to rise more Casing can be removed and debris cleared Disconnect power supply and leave the pump for a few minutes to cool Fit correct rated fuse Contact your supplier Unblock by j
7. y Ltd Units 3 5 Crayford Commercial Centre Greyhound Way Crayford Kent DA1 4HF We hereby declare that the above mentioned products conform to the following EU directives EN 60335 2 41 2003 A1 2004 A2 2010 EN 60335 1 2002 incl Corr 2009 2010 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 A14 2010 EN 62233 2008 incl Corr 2008 Person responsible for this declaration Jason Lien Director of Engineering Hung Pump Industrial Co Ltd
8. y owner Features e The MAS 250V has a built in overload switch that shuts the pump down if over heating occurs the pump then restarts once the motor has cooled down Over heating can occur in the event of dry running or restricted flow if this does occur it is important to identify the cause of the over heating and act to prevent it 3 x Leg extensions Automatic tube float Switch longer than factory fitted versions The MAS 250V is supplied with leg extensions when used in a twin pump arrangement along side a standard MAS pump with origanal feet it creates a backup assisst setup The pump with extented feet will only operate when the pumping fluid is coming in quickly to assist or if the initial pump has failed it will operate as a back up This 32mm one way valve is included which prevents the back flow of fluid from the pipework Also supplied with a 32mm 50mm nipple to connect the valve above to the pump Construction NO Description Material NO Description Maternal l Top Cover NL GF l Oil Seal 2 Motor Housing 5145304 17 O ing 3 Rotor amp Shaft SUS410 18 Oving NBR 4 stator 260 19 Oxing NBR 5 Bearing Cover PC200 20 Packing NER 6 Oil Seal Cover NL GF 21 Screw US304 7 Impeller SU3430 PU 22 Strainer NL GF 8 Upper Pump Casing NL GF 23 Feet NBR 9 Lower Pump Casing PP GF zo NUT Uaua 10 capacitor if Key SUS304 11 Bearing suJ 32 Oing NBR 12 Bearing ma m Palmia _ 13 Mech Sea