Home
MZX, installation manual, doc. version 1,1, 120.415.963
Contents
1. Information Ordering Information CPR Information Component Ordering Numbers FC421CP Outdoor CP with 514 800 806 isolator Table 3 Ordering Information Product information Doc version 1 0 CE 0832 Control Equipment Ltd Hillcrest Business Park Cinderbank Dudley West Midlands DY2 9AP UK 14 DoP 2014 2012 EN 54 11 and EN 54 17 Manual callpoint with Short Circuit Isola tor for fire detection amp fire alarm sys tems for buildings Type A Indoor FC421CP I Essential Characteristics EN54 11 Nominal activation conditions Sensitiv ity and Performance under fire condi tions Pass EN54 17 Performance under fire conditions Pass EN54 11 and EN54 17 Operational reliability Pass Durability of operational reliability tem perature resistance Pass Durability of operational reliability vibra tion resistance Pass Durability of operational reliability humidity resistance Pass Durability of operational reliability corro sion resistance Pass Durability of operational reliability elec trical stability Pass 3 4 CPR Information FC421CP I FIRECLASS Hillcrest Business Park Dudley West Midlands DY2 9AP UK www fireclass co uk FI R EC LASS FC D 421CPI PI doc version 1 0 17 December 2014 Subject to change without notice
2. Technical Specification Table 1 shows the technical specification information ture Parameter Value Material Housing and KAC Weatherproof Flame Retardant ABS Cover KAC Weatherproof Surface Mount Plastic Backbox Backbox Environment Outdoor applications Operating 25 to 70 C Temperature Storage Tempera 30 to 70 C Operating Humidity Up to 95 non condensing Dimensions HWD 93 x 97 5 x 73 mm Weight 240 g IP Rating IP67 Approvals m Product family standard EN50130 4 in respect of Conducted Disturbances Radiated Immunity Electrostatic Discharge Fast Transients and Slow High Energy m EN61000 6 3 for emissions m Construction Product Direc tive CPD fulfilling the requirements of EN 54 11 2001 A1 2006 for Manual Callpoints EN 54 17 2005 for Short Circuit Isolators Table 1 Technical Specifications 2 4 Terminals Fig 2 shows connection to the FC421CP made via the 4 way terminal connector as shown in table 2 Description Marking Comment Loop 1 L IN Interface 3 L Left 3 L OUT 4 L Right Table 2 Terminals o rOVO E Fig 2 FC421CP I Rear View and Wiring Information 1 Ancillary Programming Port 2 Ancillary Programming Lead 3 Connected to Loop N 4 Connected to Loop Left 5 Connected to Loop Out 6 Connected to Loop Right Product information Doc version 1 0 FC421CP Ordering
3. FC421CP FC421CP I Outdoor Weatherproof Resettable Callpoint FC421CP I Outdoor Weatherproof Resettable Callpoint 94 5 FIXING HOLES 3 PLACES 76 53 83 8 Fig 1 FC421CP I Weatherproof Outdoor Weatherproof Resettable Callpoint Overall and Fixing Dimensions 1 Short Circuit Isolator Activation Yellow and Alarm Indicator LED Red 2 Test Release Key Access 3 Earth Continuity Terminal Internal Introduction The FC421CP I Weatherproof Addressable Resettable Callpoint is an outdoor manual callpoint The callpoint is designed to monitor and signal the con dition of a switch contact that is operated by activating the resettable element Any change in the status of the switch is immediately communicated to the control panel The FC421CP I is fitted onto a standard KAC weather proof backbox which is supplied with the callpoint TheFC421CP I has an integral short circuit isolator for monitoring the field wiring The FC421CP I callpoint meets the requirements of EN54 Pt 11 and EN54 Pt 17 Mechanical Construction The housing consists of a combined test reset and lid release mechanism main assembly incorporating lid moulding and KAC weatherproof cover plus weather proof backbox The lid release mechanism and lid moulding retain the resettable element The lid mould ing contains the switch assembly A dual colour status indicator LED is provided on the front cover Cables may enter in
4. to the callpoint via cable gland entries at the top and bottom of the KAC weath Product information Doc version 1 0 erproof backbox The KAC weatherproof backbox may only be surface mounted An addressable module is secured within the main assembly The terminals are used for connection to the addressable circuit Operation The FC421CP I consists of a switch contact which is operated by pushing on the centre of the resettable ele ment When the callpoint is addressed by the control panel it signals the condition of this switch contact to the control panel The LED on the front of the callpoint is normally OFF until the resettable element activates then it is turned ON until the resettable element is reset As the callpoint is resettable it can be tested at any time with the aid of the callpoint test key provided After operating the callpoint the callpoint can be reset by inserting the key into the bottom of the housing releas ing the combined test reset and lid release mechanism Remove the key and slide the mechanism together with the resettable element back up until it locks into the non activated position If a section of the loop wiring adjacent to the FC421CP is shorted the built in short circuit isolator trips isolat ing the shorted section The LED is illuminated in yellow to indicate that the isolator is tripped This status remains until the short is removed 1 4 Technical Specification FC421CP
Download Pdf Manuals
Related Search
Related Contents
Samsung DIGIMAX 350 SE Manual de Usuario 取扱説明書 DinionXF – LTC 0610 & LTC 0485 series cameras Toshiba 22EL833 LED TV MAXIMA DE 2012 FHSS Test resport - Summit Data Communications - Herborner Pumpenfabrik J. H. Hoffmann & Co. dreamGEAR Silver Edition 20 In 1, DSi XL Page 1 Page 2 「世界初--`ー」 がハック社の 濁度測定にまたーつ加わり Copyright © All rights reserved.
Failed to retrieve file