1. D3 El TA B E D E F G a 4 Emergency external output def external external Output device ID Output channel Output to emergency emergen setting file 2 output name c 3 OUTPUT NAMEO1 0 no write 4 OUTPUT NAMEG2 D no write En OUTPUT NAMEOS 0 no write 6 OUTPUT NAMEO4 D no write 7 OUTPUT NAMEOS 0 no write 8 OUTPUT NAMEOS D no write EN OUTPUT NAMEO7 0 no write 10 OUTPUT NAMEOS D no write EE OUTPUT NAMEOS 0 no write 12 OUTPUTNAMEIO D no write 13 OUTPUT NAME11 0 no write 14 OUTPUT NAME12 D no write 15 OUTPUT NAME13 0 no write 16 OUTPUT NAME14 D no write EA OUTPUT NAME15 0 no write 18 OUTPUT NAME16 D no write 19 OUTPUT NAME17 0 no write 20 OUTPUT NAME18 D no write EN OUTPUT NAME1S 0 no write 22 OUTPUT NAME20 2 0 no write 23 OUTPUT NAME21 0 no write 24 OUTPUT NAME22 D no write 25 OUTPUT NAME23 0 no write 26 OUTPUT NAME24 D no write 27 OUTPUT NAME25 0 no write 28 OUTPUT NAME26 D no write 29 OUTPUT NAME27 0 no write 30 OUTPUT NAME28 28 0 no write Id 41 gt pi Fre alarm input def _ _Daor ockinput def Emergency external output def Power meter input d 4 f Ready NUM I
2. 6 10 2 Window Description 1 External emergency output name Input another name for an external emergency output number This name is not used 2 External emergency output No input prohibited External emergency output numbers are displayed in this column Do not update these numbers 3 Output device ID Specify a device ID corresponding to the external emergency output number on the line Items that can be selected in the list vary depending on the settings of the System Setting and System equipment configuration sheets 4 Output channel Specify a device output channel corresponding to the external emergency output number on the line 5 Write to setting file Specify whether to output data on the line to a setting file 45 6 10 3 Buttons No buttons are provided on this sheet 46 6 11 Power meter input definition sheet This sheet is used to set Energy Monitoring Relay Interface and its input channels when energy monitoring is used No setting is required when energy monitoring is not used 6 11 1 Window Image EJ Setting File creation software Yer 2 00 Rev01 SettingDatafile xls Eile Edit view Insert Format Tools Data Window Help DSH AaSRY XHRlO Sx amp A M0 gt Indoor unit equipment sheet
3. ERROR_CODE_C DEF ERROR CODE E DEF ERROR_CODE_J DEF and unit_table xls Details of these files are described in the table below Table 3 1 File structure File name Description DefMake xls Included in this software Start this file to run the software ERROR_CODE_C DEF Master file of the Chinese English Japanese versions of the setting Simplified Chinese file ERROR_CODE_DEF ERROR_CODE_E DEF English ERROR_CODE_J DEF Japanese setting ini An INI file stores the language to be used and previously stored data such as file path Language msf A file describing a message number word correspondence table to make this software multilingual Japanese Japanese environment or English English environment is applied for Language unit_table xls Equipment model name file Excel Workbook file describing equipment parameters Used to determine parameters power model etc The following shows the directory structure of these files Destination folder MasterFile O A ERROR_CODE PARAM_FILE DefWake xls setting ini fanrgvage mst E ERROR_CODE_C DEF unit_table xls ERROR_CODE_E DEF ERROR CODE _J DEF Fig 3 1 Directory structure of the software Do not change the directory file name or file saving place of the installation destination In this software create a new Excel Workbook file to input data equipment data tenant data etc t
4. Indoor unit ID number issue Used to issue indoor unit specific numbers to the Indoor unit ID number column sequentially from the top Header indoor unit object_id number Used to issue object_id to input data automatically in the object_id and Header indoor unit ID number columns R C group indoor unit capacity code input Used to input data automatically in the Indoor unit capacity code to Power consumption through HA control interface columns by finding capacity code of each indoor unit indoor unit fan motor capacity and indoor unit heater capacity using the Indoor unit model name data 4 R C group indoor No issue Used to input indoor unit group specific data automatically in the R C group indoor No column 5 Outdoor unit No input from Outdoor unit group definition sheet Used to input appropriate data automatically in the Outdoor unit No column in the Indoor unit group definition sheet based on the outdoor unit numbers issued for each refrigerant system in the S MMS outdoor unit group definition sheet Insert parting line for line address Used to separate refrigerant systems in the table with horizontal lines No setting input at once Used to specify No setting in all the lines of selected items when Door lock input name Fire alarm input name and Power meter input name are currently selected 1
5. Setting File creation software Ver 2 00 Rev01 File selection View Exit File name Microsoft Excel Ax C Program Files TOSHIBA CARRIER SettingFileCreationSoftwarelBin DefMake xls contains macros Macros may contain viruses It is always safe to disable macros but if the macros are legitimate you might lose some Functionality i Enable Macros More Info Fig 4 2 Main dialog Fig 4 3 Macro enable disable selection dialog If the dialog does not appear click Tools Macro Security from the Excel menu bar to open the Security dialog Choose Medium security level Fig 4 4 Then exit Excel and double click the DEF Make Tool icon on the desktop to restart the software Security 2 x 3 Trusted Sources asert Format Tools Data Window Help C High Only signed macros from trusted sources will be Zee BF Spe gt allowed to run Unsigned macros are automatically 188 AA disabled e pe Medium You can choose whether or not to run a DEEE potentially unsafe macros Track Changes wars Mod C Low not recommended You are not protected from Protection potentially unsafe macros Use this setting only if you Online Collaboration gt have virus scanning software installed or you are sure mmm all documents you open are safe ros ord New Macro Customize Security Options No virus scanner installed 5 visual Basic Editor Alt F11
6. node_id x1 x2 and x3 in the Intelligent Server table at their lowest value because this data is entered automatically for these items in the following processes Input data in the Block number issue sheet Firstly input all the block names to be registered from the uppermost line of the Block name Then press Block number issue and List display input at once to input data automatically into the Block No and List display validity columns List display validity is used to select whether to display the block name on the line in the list displayed when Block name in the Indoor unit group definition sheet is selected Input data in the Area number issue sheet Firstly input all the area names to be registered from the uppermost line of Area name Then press Area number issue and List display input at once to input data automatically into the Area No and List display validity columns List display validity is used to select whether to display the area name on the line in the list displayed when Area name in the Indoor unit group definition sheet is selected Input data in the Monthly report tenant name definition sheet Firstly input all the monthly report tenant names to be registered in Monthly report tenant name Then press Monthly report tenant number issue and List display input at once to
7. Ajs s juos oo 8 oo wa Fig 7 1 unit_table xls window 59 The unit table xls file includes 3 sheets Outdoor Indoor and Parameter The Outdoor sheet describes the outdoor unit parameters and the Indoor sheet describes the indoor unit parameters To register an outdoor unit model name describe the parameters for the following items in the table on the Outdoor sheet e Device type Input 0 for multi system models Model name Input an outdoor unit model name to be registered Total indoor unit capacity code HP Total indoor unit fan motor capacity kW Total indoor unit heater capacity kW Input 0 Total outdoor unit crankcase heater capacity kW Input total outdoor unit crankcase heater capacity of the models to be registered in kW Indoor unit Qty Input 0 Outdoor unit Qty Input 1 for single outdoor unit model name For outdoor units with set model name input the number of outdoor units defined by the set model name Indoor unit object management No Input FFFF Outdoor unit object management No Input OFO2 for multi system equipment Domestic overseas Date of addition Do not input data for these items Use for reference To register an indoor unit model name describe the parameters for the following items in the table on the Indoor sheet e Device type Inpu
8. sheet 33 List display input at once Used to set 1 display for List display validity in all lines with a block name 5 Delete duplicated block name Used to delete the line of duplication if any block name is duplicated Sort block name Used to sort Block name from the top 34 6 5 Area number issue sheet This sheet is used to register area names Ensure one or more area names are registered 6 5 1 Window Image EJ Setting File creation software Ver 2 00 RevO1 SettingDataFile xls ll xj 168 Eile Edit View Insert Format Tools Data Window Help lal xj Sua SAS seer oer slm gt M5 ur Gothic 10 gt B7U H 8 E A A 2 Areato issue Indoor settingSheet sAreaNo UpDate Indoor settingSheet sAreaName UpDate List display input at once Delete duplicated name Sort name c3 z AT B G gt E ae a a n LT MIN 4 1 Area number issue Areo No Areo nome List disploy volidity GEE EE Sige ala als als ala ojo o als 00 1 a Ina Ia Ina mo Ino Ia Ina N 8 8 0 3 0 01 8 00 gt ja Y Ready 6 5 2 Window Description 1 Area No A unique number assigned to each area name Area numbers can be issued by pressing Area number issue button 2 Area name Input an area name to be displayed on the Touch Screen Controller screen 3 List display validity Specify whether to display the area name on th
9. ON OFF switching prohibition reset Setting No 3 OFF ON OFF switching prohibition reset 9 Door lock interlocking central setting Specify a door lock interlocking operation The following 4 patterns can be selected Setting Locking OFF to ON OFF ON OFF switching prohibited ON ON OFF switching prohibition reset Unlocking ON to OFF No central setting OFF No action Setting No 1 OFF ON OFF switching prohibition reset Setting No 2 OFF ON OFF switching prohibited ON OFF switching prohibition reset Setting No 3 10 Energy monitoring OFF No action Choose 1 Valid or 0 Void for whether to use energy monitoring 11 Power meter pulse constant setting Choose 1 Valid or 0 Void for whether to input power meter pulse constant in WHM _CH DEF Set 0 Void usually 12 Stand by power counting Specify Outdoor refrigerant system heater capacity kW calculation method in the Indoor unit group definition sheet The following 3 methods can be selected 1 Proportional sharing on indoor unit horse power codes Calculated using the proportional sharing method 2 Equal sharing on indoor units Qty 0 N A 13 kW conversion coefficient input prohibited This coefficient is used when calculating outdoor refrigerant system heater capacity kW of indoor unit sw using the proportional sharing
10. Setting No 2 OFF ON OFF OFF ON OFF ON OFF switching switching prohibition reset switching prohibited prohibition reset Setting No 3 OFF ON OFF OFF ON OFF ON ON OFF switching switching prohibition reset switching prohibited prohibition reset e Setting numbers for door lock interlocking central setting items Interlocking operation patterns vary depending on the setting Setting Locking OFF to ON Unlocking ON to OFF No central setting OFF No action Setting No 1 OFF ON OFF switching prohibition reset Setting No 2 OFF ON OFF switching prohibited ON OFF switching prohibition reset Setting No 3 OFF No action e When energy monitoring is not used Stand by power counting and Power meter pulse constant setting are not entered Input data in the System equipment configuration sheet Specify the number of interfaces connected to each Intelligent Server Depending on the number input in Intelligent Server Qty on the System Setting sheet areas allowing data input will vary Input the number of interfaces in the white cells on the table For details of each item refer to 6 2 in this manual 17 Input data in the Address Setting sheet Input data in the white cells Device type and TCS Net Relay Interface No Leave items TCS Net Relay Interface No Header indoor unit ID number object_id net_id
11. file and close the window Registered model names are available for the next time the Setting File Creation Software is used 61 7 2 Setting file output Setting file output starts by pressing Setting File create on the System Setting sheet When the Setting File create button is pressed the following dialog Fig 7 2 appears Click OK on the dialog Microsoft Excel xi Check the data before creating setting file Fig 7 2 Data checking start dialog Checking of data in the sheets start If no data or invalid data is found an error dialog appears and the ongoing processing is interrupted In such case correct the error and then press Setting File create again Upon completion of the data checking the following dialog Fig 7 3 appears Microsoft Excel xi Data checking has Completed And now start to make DEF files Fig 7 3 Data checking completed dialog Click OK on the dialog The Browse for Folder dialog Fig 7 4 appears Choose a folder to save the setting file to and click OK Do not choose Desktop or My Computer This will result in an error Browse for Folder Wi xj Select the folder output to Desktop A My Documents My Computer H E Local Disk C H E Removable Disk E EE Control Panel E e My Network Places f Recycle Bin amp Internet Explorer ca picture concel_ Fig 7 4 Browse for Folder dialog Then the Fi
12. 6 14 2 Window Description Input items 1 Power meter input name Input the name of the power meter input corresponding to the outdoor unit on the line 2 Write into setting file When 2 no write is selected on the line the description of the line is not output to WHM_OUT_MAP DEP Input prohibited items 3 Device type input prohibited Device type of the outdoor unit on the line is input This is entered automatically each time you press New 57 4 R C group indoor No input prohibited R C group indoor No of Digital Inverter Super Digital Inverter unit and general purpose interface corresponding to the outdoor unit on the line entered in the in Indoor unit group definition sheet is input This number is entered automatically each time you press New 5 Power meter input No input prohibited Power meter input number corresponding to the Power meter input name data on the line is displayed Do not input data directly as appropriate values are input automatically by entering data in the Power meter input name column 6 Outdoor unit model name input prohibited The Digital Inverter Super Digital Inverter model name of the outdoor unit on the line is input For general purpose interfaces General purpose interface outdoor unit is input This model name is entered automatically each time you press New 7 Outdoor unit address input prohibited This unit addre
13. GA Microsoft Script Editor Alt Shift F11 o ca Fig 4 4 Security dialog 4 2 2 Exiting the software program To exit the software program with the main dialog open click Exit on the main dialog or click X at the upper right of the dialog When the data input window is open click X at the upper right of the window or click Files Exit on the menu bar in the same way as exiting Excel 14 4 3 Data input window Fig 4 5 shows the setup data input window Enter setup data in the blank area of the table on each sheet in the same way as Excel data input You do not need to input data into the grey coloured cells on the table data will be automatically generated within these cells Be oe yen poet Format a Winds teb Dlo AF LBA gt Or MD Teer AC AA Y Doj seme fie creme Setting Touch Sereen Controler No _Daay report closing sme meter read tne Dady report closing tme meter read tene 1 name Server Oty und total O Moreny report closing date 1 Stand by power counting Y Proposonal shanng on Conversion coeficient dspiay mode ares Gsplay bumons Setting unt Buking Mor hty amber or tock dada been Number of Namber of hedde Number of block dspiay buttons SSS Number of R C groupindoor display butors Number of RC grouplindoor display buttons Sede semmgunt Fer sign display mode IOP p System setting
14. kWh pulse item is not available Input data in the S MMS outdoor unit group definition sheet Input data for the white cells in the table Intelligent Server No TCS Net Relay Interface No Line address Outdoor unit model name and Outdoor unit No from the uppermost line for all outdoor units If a model name you want to input is not included in the model list displayed when entering data in the Outdoor unit model name column the model name must be registered in the equipment model table see 7 1 However this is not necessary when energy monitoring is not used In such case a similar model name can be entered No data input in this sheet is required for the outdoor units of Digital Inverter Super Digital Inverter equipment When using an outdoor unit of outdoor set model input the line of the header outdoor unit of the model input an outdoor set model for Outdoor model name and 1 for Outdoor unit No and then press Outdoor follower unit insert Lines of outdoor follower units of the outdoor set model are inserted automatically Press Outdoor unit number issue and Input at once Write into setting file buttons to input data automatically in the Outdoor unit No and Write into setting file columns Choose the name of the power meter input corresponding to the outdoor unit on the line from the list for Power meter input name Also enter the
15. Power meter input name column on the line is displayed Do not input data directly as this number is input automatically by entering data in the Power meter input name column 17 Device type input prohibited Device type number corresponding to the outdoor unit model name on the line is displayed Do not input data directly as appropriate values are input automatically by entering data in the Outdoor unit model name column 50 6 12 3 Buttons Outdoor unit number issue Used to issue an outdoor unit number unique to each outdoor unit group to input data automatically in the Outdoor unit No column Outdoor follower unit insert Used to insert lines by finding the number of follower outdoor units from the model name when the model name in Outdoor unit model name is a set model name Check with Indoor unit group definition sheet Used to check whether multi system indoor units are included in the same refrigerant system by comparing with the data in the Indoor unit group definition sheet Insert parting line for line address Used to separate refrigerant systems in the table with horizontal lines 5 Insert at once Write into setting file Used to specify 1 write for Write into setting file on all the lines with data No setting input at once Input No setting in all lines in the Power meter input name column 51 6 13 Indoor
16. SAY RA 2 f Ald 0 nsu Gothic 10 B7Uu Es x E aA 2 Follower Outdoor unit insert Check with Indoor unit group definition sheet Insert parting line for line address Input at once Write into setting file No setting input at once B a 4 B D E POEs IE I J K L mM N 0 AER a TIA 1 SMMS Outdoor unit group det Header obj_id net_id node x1 x2 x3 Intelligen TCS Net Line Outdoor unit Outdoor Power meter Write into Outdoor Power D outdoor d t Server Relay address model name unit input name setting file unit No meter c unit ID No Interface address input No ty re eee oo md an MD PI Emergency external output def Power meter input def _ SMMS Outdoor unit group def Indoc 4 gt f Ready ii NUM 6 12 2 Window Description Input items 1 Intelligent Server No Input Intelligent Server No corresponding to the outdoor unit on the line 2 TCS Net Relay Interface No Input TCS Net Relay Interface address corresponding to the outdoor unit on the line 3 Line address Input refrigerant line address of the outdoor unit on the line 4 Outdoor unit model name Input outdoor unit model name of the outdoor unit on the line 5 Outdoor unit address Input outdoor unit address
17. Sytem mamen coign J adie stra a Ale ei Roady WM Fig 4 5 Setting data input window Customized buttons are displayed on the Excel toolbar Fig 4 6 The customized toolbar is displayed on each of the work sheets with their respective buttons These buttons are assigned to the following number issue for setting files data update setting file creation etc Details of the buttons are described in chapter 6 When the length of the button is insufficient some buttons are hidden In this case click the arrow at the right end of the toolbar to display the hidden buttons Fig 4 7 sel a LTT TELE EELEE iaa R C groupfindoor unit capacity code input R C groupfindo A B C D E F Indoor unit group de DOE dn set qdo del cs st rn det E Sn SS un E Fig 4 6 Buttons on the toolbar s x E A 2 it once E Q R Fig 4 7 Display hidden buttons 15 5 Setting File Creation Procedure The Excel Workbook file for setup data input includes 14 sheets in total Complete them in the following order System Setting sheet System equipment configuration sheet Address Setting sheet Block number issue sheet Area number issue sheet Monthly report tenant name definition sheet Tenant number issue sheet Fire alarm input definition sheet 9 Door lock input definition sheet 10 Emergenc
18. group is described here When the indoor unit is a follower unit is displayed Do not input data directly as appropriate values are input automatically by pressing R C group indoor unit capacity code input button 37 Indoor unit fan motor capacity kW input prohibited Indoor unit fan motor capacity corresponding to the indoor unit model name on the line is displayed Do not input data directly as appropriate values are input automatically by pressing R C group indoor unit capacity code input button When energy monitoring is not used data input is not required 38 R C group indoor unit fan motor capacity kW input prohibited When the indoor unit on the line is a header or individual unit R C group indoor unit fan motor capacity total of indoor unit fan motor capacity in the indoor unit group is described here When the indoor unit is a follower unit is displayed Do not input data directly as appropriate values are input automatically by pressing R C group indoor unit capacity code input button 39 Outdoor unit stand by consumption kW input prohibited When the indoor unit on the line is a header or individual unit outdoor unit stand by consumption is described here When the indoor unit is a follower unit is displayed Do not input data directly as appropriate values are input automatically by pressing R C group indoor unit capacity code input button 55 6 13 3 Buttons
19. group definition sheet When Intelligent Server No TCS Net Relay Interface No Line address or Outdoor unit model name is updated Press R C group indoor unit capacity code input Outdoor unit No input from Outdoor unit group definition sheet and Header indoor unit object id number buttons in the Indoor unit group definition sheet to update the data To add a outdoor unit Input data in the white cell on the blank line Press Outdoor unit number issue to input data automatically in the Outdoor unit No column and then press R C group indoor unit capacity code input Outdoor unit No input from Outdoor unit group definition sheet and Header indoor unit object id number buttons on the Indoor unit group definition sheet to update data A line can be inserted by clicking Insert Line on the menu bar To delete a outdoor unit Choose a cell on the line where the outdoor unit is that you want to delete and click Edit Delete on the menu bar Select All lines on the dialog displayed and click OK The line is deleted Next press R C group indoor unit capacity code input in the Indoor unit group definition sheet to update Indoor unit capacity code to Model 3 Indoor unit group definition sheet To add a indoor unit Update Indoor unit total Qty in the System Setting sheet first Then input data in the whit
20. input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 10 x1 input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 31 11 x2 input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 12 x3 input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 6 3 3 Buttons No buttons are provided on this sheet 32 6 4 Block number issue sheet This sheet is used to register block names Ensure one or more blocks are registered 6 4 1 Window Image ile creation software Ver 2 00 Rev01 SettingDataFile xls Tan laj xj E Eile Edit view Insert F
21. name of the power meter input corresponding to the follower outdoor unit on the line of follower outdoor unit Set the power meter input name for each outdoor unit When you do not assign the power meter input select No setting Leave Header outdoor unit ID number and object_id because these items are completed automatically in the following process When the system is configured with Digital Inverter Super Digital Inverter equipment only this sheet requires no data input Write into setting file is used to specify whether to output the outdoor unit data on the line to OUT_GROUP DEP or listOfApparatus txt file Select 1 write usually 3 Input data in the Indoor unit group definition sheet Press Indoor unit ID number issue first to input data automatically into the Indoor unit ID number column Then input data into the white cells for the table from the uppermost line for all indoor units For Header indoor unit ID number input 0 when the indoor unit on the line is a header or an individual unit or input the header indoor unit ID number when the indoor unit is a follower unit If a model you want to input is not included in the model list displayed when entering data in the Indoor unit model name column the model name must be registered in the equipment model table see 7 1 However this is not necessary when energy monitoring is not used In such
22. not input data directly in this column e I O kit table for use in Japan Displayed when a number more than 0 is set for I O kit Qty in the System Setting sheet 1 Equipment category input prohibited I O kit is displayed Do not update this column directly 2 Unit number input prohibited I O kit numbers are listed Do not update this column directly 3 Device type Specify I O kit type 8ch or 16ch Though this setting is not used no setting file can be output if this item is left blank 30 e Energy Monitoring Relay Interface table for use in Japan Displayed when a number more than 0 is set for Energy Monitoring Relay Interface Qty in the System Setting sheet 1 Equipment category input prohibited Energy Monitoring Relay Interface is displayed Do not update this column directly 2 Unit number input prohibited Energy Monitoring Relay Interface unit numbers are listed Do not update this column directly 3 TCS Net Relay Interface No Specify an Energy Monitoring Relay Interface number Though this setting is not used no setting file can be output if this item is left blank Intelligent Server Interface table lowest 1 Intelligent Server No input prohibited Intelligent Server numbers are listed Do not update this column directly 2 IP address input prohibited IP addresses assigned to respective Intelligent Servers in each line are listed
23. of the outdoor unit on the line 6 Power meter input name Input the name of power meter input corresponding to the outdoor unit on the line when using energy monitoring Also enter the name of the power meter input corresponding to the follower outdoor unit in the line of the follower outdoor unit Set power meter input name for each outdoor unit When you do not use energy monitoring or assign power meter input select No setting 7 Write to setting file Specify whether to output the outdoor unit data on the line to the OUT_GROUP DEF or listOfApparatus txt file 49 e Input prohibited items 8 Header outdoor unit ID number input prohibited Hexadecimal data to be described in setting files is displayed indicating outdoor unit group data Do not input data directly as appropriate values are input automatically by pressing Header indoor unit object_id number button in the Indoor unit group definition sheet 9 object_id input prohibited Hexadecimal data to be described in setting files is displayed The data is unique to the interfaces and all units connected to the Intelligent Server Do not input data directly as appropriate values are input automatically by pressing Header indoor unit object_id number button in the Indoor unit group definition sheet 10 net_id input prohibited Hexadecimal data to be described in setting files is displayed indicating TCS Net Relay Interface number Do not
24. on indoor unit horse power codes Do not change this value as it is fixed to 0 75 Calculated using the equal sharing method Stand by power counting is always 0 27 14 Whole building display mode Specify a display unit when Whole building button is pressed Choose 0 block 1 tenant 2 area or 3 R C group indoor 15 Number of block display buttons Specify the number of horizontal buttons in the block display mode 16 Number of tenant display buttons Specify the number of horizontal buttons in the tenant display mode 17 Number of area display buttons Specify the number of horizontal buttons in the area display mode 18 Number of R C group indoor display buttons Specify the number of horizontal buttons in the R C group indoor display mode 19 Schedule setting unit Choose 1 R C group indoor or O area unit for schedule setting unit 20 Filter sign display mode Choose 1 display or O not display for filter sign display mode 21 Backlight save count minutes Set backlight save count on the Touch Screen Controller screen in units of minute 6 1 3 Buttons Setting File create Used to output setting files Press this button after entering all data on every sheet to execute the creation of a setting file 28 6 2 System equipment configuration sheet This sheet is used to specify the number of the following interfaces connected to
25. 14 4 2 1 Starting the software program nnn eennnenennnnerreneereennerennnenvennnerennnnenvenvnervennneneennnenenneereennnn 14 4 2 2 Exiting the software program nnnnnnnneennenneeneeeennnnneneevennnenvennevennennenreeennnennensevennnnnneene vennen 14 4 3 Data input WINDOW Sara io 15 5 Setting File Creation Procedure nennen 15 S TINGW Tile CS MON AA ca 17 5 1 1 Starting the Program nennen iina aa aaia ae na iaa aE aa ae iane aa akie 17 5 1 2 Creating a neW file mersa ntt rant AA en el 17 5 2 Setting file update Rs eee dann 22 5 2 1 Starting the Program rant a A a adi 22 5 2 2 Updating data anne teeeeinventervervamann teeven eveneens leveren ane a A E 22 6 Window Descriptions and Buttons on Each Sheet 26 61 System Seting Sheen dette eten 26 6 1 1 Window Image cece ere nennen 26 6 1 2 Window Description enoia a aae a EA AE a E A RATAA aiaa 26 621 3 1 te ALERE aS AOT denn A A A telnr E AE AEEA OEE AE A 28 6 2 System equipment configuration sheet nnnnnnennnnnnnnnenee eeen vennnneenenenenen 29 6 2 1 Window Image nennen vennen nenene A aA EE NA AART E aa E rA AAA Ea 29 6 2 2 Window Description asrorni AD Aa N a aA 29 6 2 9 BURON Shae a a da da 29 6 3 Address Setting sheet cee a Lec edelen 30 6 3 1 Window Image ccoo A 30 6 3 2 Window Description eiiiai an icki i ieena asn ar aan EEEa aasa EAE EEEE TA aE a ea 30 6 3 3 BUTONG serii ese eae id aa devel
26. 26 R C group indoor No input prohibited Numbers used in setting files which are issued for each indoor unit group Press R C group indoor unit No issue to input data automatically 27 Outdoor unit No input prohibited Outdoor unit number of the outdoor unit in the R C group of the indoor unit on the line Do not input data directly as appropriate values are input automatically by pressing Outdoor unit No input from Outdoor unit group definition sheet button 28 Device type input prohibited Device type number corresponding to the indoor unit model name on the line is displayed 0 MMS indoor units 1 Digital Inverter Super Digital Inverter indoor units 2 General purpose interfaces Do not input data directly as appropriate values are input automatically by entering data in the Indoor unit model name column 29 Tenant No input prohibited Tenant number corresponding to the Tenant name data on the line Do not input data directly as appropriate values are input automatically by entering data in the Tenant name column 30 Area No input prohibited Area number corresponding to the Area name data on the line Do not input data directly as appropriate values are input automatically by entering data in the Area name column 54 31 Block No input prohibited Block number corresponding to the Block name data on the line Do not input data directly as appropri
27. 7 6 1 4 T Window IMAGE arne AA 57 6 14 2 Window Description annen E E a T eE TEE R A EA IE 57 6714 3 Buttons iosi nier E E venen EET E ewa i O N AA 58 T NOTES naaa a a a 7 1 Equipment model table unit_table xls oooooooonccnnnccccncccncnconanoncnnncncnnnnnnnnnnnnnnnnnos 59 7 1 1 Registering indoor unit outdoor unit model names in Equipment model table nn 59 7 2 Send MSS OUI reeet ee NA a ee sane ene 62 1 What is Setting File Creation Software This software is a tool to create setting files for the Air conditioning Control System Setting files of Touch Screen Controller Setting File Creation Software Character code used for setting files Font used for input on Microsoft Excel sheets Japan version Shift JIS MS UI Gothic Overseas version Unicode MS UI Gothic Verified foreign languages e Japanese e English e Chinese Simplified Traditional The software is composed of Excel VBA output setting files according to the specific format of the data in the Excel workbook Table 1 1 Output setting files File name Description AC_GROUP DEF Indoor unit group config file AC_MAP DEF R C group indoor setting file AC_NAME DEF R C group indoor name definition file ANBUN_MAP DEF Energy monitoring tenant name conversion setting file ANBUN_NAME DEF Energy monitoring tenant name setting file BACKLIGHT DEF Backlight save count setting file BLOCK_NAM
28. Do not update this column directly 3 Equipment category input prohibited Interface names connected to respective Intelligent Servers in each line are listed 4 Unit number input prohibited Interface unit numbers in each line are listed Do not update this column directly 5 TCS Net Relay Interface No Specify an interface number connected to each Intelligent Server When an interface number is updated press Header indoor unit object_id number on the Indoor unit group definition sheet to update data of items 6 to 12 6 Header indoor unit ID number input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 7 object_id input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 8 net_id input prohibited Hexadecimal data to be described in the setting files is displayed Do not input data here directly because the appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 9 node_id
29. E DEF Block name definition file BUILD_NAME DEF Building name definition file CONT_IP DEF Touch Screen Controller IP address definition file CONT_no DEF Touch Screen Controller number check file DISP_FORM DEF Display setting file EMGOUT_CH DEF Emergency external output definition file EREA_NAME DEF Area name definition file ERROR_CODE DEF Error code definition file FIRE_CH DEF Fire alarm input definition file IO_IP DEF I O Controller IP address definition file KEY_CH DEF Door lock input definition file ListOfApparatus txt Equipment definition file ListOfEpcPackage txt View at once file LSV_IP DEF Intelligent Server IP address definition file OUT_GROUP DEF Outdoor unit group config file REPORT DEF Report setting file RUN_MODE DEF Operation mode setting file TENANT_NAME DEF Tenant name definition file WHM_CH DEF Power meter input definition file WHM_MAP DEF Energy monitoring setting file WHM_MAP_OUT DEF Energy monitoring setting file for outdoor units 2 Operating Environment Operating environment Personal computer Windows 2000 or XP compatible PC Operating system OS Windows 2000 XP Microsoft Excel Excel 2000 or newer is required separately 3 Installation Uninstallation Procedures 3 1 Program file structure The software is composed of 5 files DefMake xls
30. TOSHIBA FILE NO E05 412 TCS NET Air Conditioning Control System Setting File Creation Software User s Manual Introduction This is the User s Manual for the Setting File Creation Software here after referred to as the software for the Air conditioning Control System Setting File Creation Software Ver 2 00 Revision 02 This Software Ver 2 0 Rev 02 is not compatible with Ver 1 0 e Windows 2000 and Windows XP are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries e Microsoft Excel is a trademark or registered trademark of Microsoft Corporation in the United States and other countries e All company names and product names appearing in this manual are the trademark or registered trademark of their respective holders No indication such as TM or that stands for a trademark or registered trademark appears in this manual Table of Contents NOA UICN REEN 2 TADEO Croin int EE 3 1 What is Setting File Creation Software oooccconcccccnnacicocaninnns 6 2 Operating Environment nnnnnaassnennenaneennennnnennnnnnenn 7 3 Installation Uninstallation Procedures 00ccoccccoonccononcoonononos 8 3 1 Program file structure wateren deden neten 8 ISAO A ARI 10 3 39 UAM Sa AIM A A Ac 12 4 OperatlOn cisco d eect asada iat ee esters 13 4 1 Transition Of WINDOWS usa a did 13 4 2 Start p And SNG eener nent drankenmarkt
31. adecimal data to be described in setting files is displayed indicating TCS Net Relay Interface number Do not input data directly as appropriate values are input automatically by entering data in the TCS Net Relay Interface No column 21 node_id input prohibited Hexadecimal data to be described in setting files is displayed indicating line address Do not input data directly as appropriate values are input automatically by entering data in the Line address column 22 x1 input prohibited Hexadecimal data to be described in setting files is displayed indicating device type Do not input data directly as appropriate values are input automatically by entering data in the Indoor unit model name column 23 x2 input prohibited Hexadecimal data to be described in setting files is displayed indicating device type Do not input data directly as appropriate values are input automatically by entering data in the Indoor unit model name column 24 x3 input prohibited Hexadecimal data to be described in setting files is displayed indicating indoor unit address Do not input data directly as appropriate values are input automatically by entering data in the Indoor unit address column 25 Indoor unit ID number input prohibited A number used for this software only to identify indoor units This is used to specify group in 13 Press Indoor unit ID number issue to input data automatically
32. ame for a fire alarm input number This name is used on the Indoor unit group definition sheet 2 Fire alarm input No input prohibited Fire alarm input numbers are displayed in this column Do not update these numbers 3 Input device ID Specify a device ID corresponding to the fire alarm input number on the line Items that can be selected in the list vary depending on the settings of the System Setting and System equipment configuration sheets 4 Input channel Specify a device input channel corresponding to the fire alarm input number on the line 5 Signal logic Specify whether to stop operation of equipment when a fire alarm input turns ON positive logic or when it turns OFF negative logic 6 Output to a setting file Specify whether to output data on the line to a setting file 41 6 8 3 Buttons Indoor unit equipment sheet update by fire alarm input No Used to update Fire alarm input name based on the Fire alarm input No data on the Indoor unit group definition sheet Indoor unit equipment sheet update by fire alarm input name Used to update Fire alarm input No based on the Fire alarm input name data on the Indoor unit group definition sheet 42 6 9 Door lock input definition sheet This sheet is used to set I O interfaces and input channels used for door lock inputs when using the door lock interlocking function No setting is require
33. ate values are input automatically by entering data in the Block name column 32 Door lock input No input prohibited Door lock input number corresponding to the Door lock input name data on the line Do not input data directly as appropriate values are input automatically by entering data in the Door loek input name column 33 Fire alarm input No input prohibited Fire alarm input number corresponding to the Fire alarm input name data on the line Do not input data directly as appropriate values are input automatically by entering data in the Fire alarm input name column 34 Power meter input No input prohibited Power meter input number corresponding to the Power meter input name data on the line Do not input data directly as appropriate values are input automatically by entering data in the Power meter input name column 35 Indoor unit capacity code input prohibited Indoor unit capacity code corresponding to the indoor unit model name on the line is displayed Do not input data directly as appropriate values are input automatically by pressing R C group indoor unit capacity code input button When energy monitoring is not used data input is not required 36 R C group indoor unit capacity code input prohibited When the indoor unit on the line is a header or individual unit R C group indoor unit capacity code total of indoor unit capacity code in the indoor unit
34. case a similar model name can be entered Be careful with MMS and Digital Inverter Super Digital Inverter equipment 19 Press Input at once Write into setting file Header indoor unit object_id number and R C group indoor number issue buttons to input data automatically into the object_id Header indoor unit ID number Write into setting file and R C group indoor No columns Press R C group indoor unit capacity code input button see 7 1 to input the data automatically in the Indoor unit capacity code to Power consumption through HA control interface columns For general purpose interfaces input data directly into Power consumption through HA control interface Press R C group indoor unit capacity code input button to input the data automatically into the Indoor unit capacity code columns Press Outdoor unit No input from Outdoor unit group definition sheet button to input data automatically into the Outdoor unit No column For Digital Inverter Super Digital Inverter equipment input a set model name for Indoor unit model name Data of outdoor unit or follower indoor units is not required Write into setting file is used to specify whether to output the indoor unit data on the line of OUT_GROUP DEP or listOfApparatus txt file Select 1 write usually R C group indoor name Tenant name Area name Bloc
35. d Header indoor unit ID number e No item needs to be updated when these items are updated Block number issue sheet e To add a block Input a block name you want to add to the blank line of Block name Then press Block number issue to input data automatically in the Block No column Choose 1 display for List display validity A line can be inserted by clicking Insert Line on the menu bar e To delete a block Choose a cell in the line you want to delete and click Edit Delete on the menu bar Select All lines on the dialog displayed and click OK e When Block name is updated Block name in the Indoor unit group definition sheet can be easily updated by pressing Equipment setting sheet block name update Further Block No in the same sheet can be updated with the Equipment setting sheet block number update button e To re issue Block No Delete all data in Block No and then press Block number issue to issue a block number 22 Area number issue sheet Same as Block number issue sheet Monthly report tenant name definition sheet Same as Block number issue sheet Press Monthly report tenant number update in tenant number issue sheet and Monthly report tenant name update in tenant number issue sheet buttons to update Monthly report tenant No or Monthly report tenant name in the Tenant numbe
36. d when door lock interlocking is not used 6 9 1 Window Image El Setting File creation software Yer 2 00 Rev01 SettingDataFile xls File Edit View Insert Format Tools Data Window Help JOSS 6A sBOelo Szr 24 00 M5 ur Gothic 10 B7U Indoor unit equipment sheet update by input No Indoor unit equipment sheet update by input name Input device ID Input channel Signal logic Nas o 15 INPUT NAMES INPUTRAMES gg T INPUT NAMET INPUT NAMES TTT TTT Se _ _ ______ __ _E INPUT NAMES INPUT NAMES PUT NAMES a ra RRR t4 41 gt PIZ Tenant number issue Fire alarm input def Door lock input def Emergency external output def 4 Ready 6 9 2 Window Description 1 Door lock input name Input another name for a door lock input number This name is used on the Indoor unit group definition sheet 2 Door lock input No input prohibited Door lock input numbers are displayed in this column Do not update these numbers 3 Input device ID Specify a device ID corresponding to the door lock input number on the line Items that can be selected in the list vary depending on the settings of the System Setting and System equipment configuration sheets 4 Input channel Specify a device input channel corresponding to the door lock input number on the line 5 Signal logic Specify whether to stop operation of equipm
37. data automatically in the Outdoor unit No column Once R C group indoor No is issued an issue log is recorded in the R C group indoor unit No manage sheet and so a number that was previously issued can no longer be issued unless the issue log is cleared To clear the log and re issue R C group indoor No from the beginning clear all the data in R C group indoor No and R C group indoor unit No manage sheet and then re issue R C group indoor No If the R C group indoor number issue button is pressed with R C group indoor No issued already the Do you re issue dialog appears Click Yes to re issue R C group indoor No When a Digital Inverter Super Digital Inverter unit is added or removed the Outdoor unit group definition other than S MMS sheet must be updated Click New on the sheet to update the table When a Digital Inverter Super Digital Inverter unit is added a line of the corresponding outdoor unit is created Perform setting on the line for power meter input e When R C group indoor name Tenant name Area name Block name Door lock input name Fire alarm input name or Power meter input name is updated no item must be updated Outdoor unit group definition other than S MMS sheet No item need to be updated when these items are updated 25 6 Window Descriptions and Buttons on Each Sheet 6 1 System Setting sheet Th
38. e Items that can be selected in the list vary depending on the settings of the System Setting and System equipment configuration sheets 4 Input channel Specify a device input channel corresponding to the power meter input number on the line 5 Pulse constants kWh pulse Specify power meter pulse constants on the line 6 Write to setting file Specify whether to output data on the line to a setting file 47 6 11 3 Buttons Indoor unit equipment sheet update by power meter input No Used to update Power meter input name based on the Power meter input No data on the Indoor unit group definition sheet Indoor unit equipment sheet update by power meter input name Used to update Power meter input No based on the Power meter input name data on the Indoor unit group definition sheet 48 6 12 S MMS outdoor unit group definition sheet This sheet is used to input various setting data for Super Modular Multi System outdoor units Input data for all connected outdoor units When input data of outdoor set model name fill in the header outdoor unit line and press Outdoor follower unit insert Lines of outdoor follower units corresponding to the outdoor set model name are inserted automatically 6 12 1 Window Image El setting File creation software Ver 2 00 Rev01 SettingDatarile xls i E laj xi 69 Bile Edt View Insert Format Tools Data Window Help laj x IDS
39. e gt m Programs Add Remove Components Windows Control Panel Set Program Access and Defaults Fig 3 9 Add Remove Programs dialog Add Remove Programs xd 2 Are you sure you want to remove SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 from your computer Fig 3 10 Confirmation dialog 12 4 Operation 4 1 Transition of windows The following shows the window transitions of the software Details of this diagram are described in the following Fig 4 1 Transition of windows r Setting File creation software er 2 00 Revot El r j i Edit File selection View Exit File name Double click startup Exit button END in di Edit a file to input nt MARIO e existing setting data File selection button mas Jue Weten a Setting File creation software ver 1 000 x l l l l New Edit l l l 1 File selection l l l l l l l l l 1 l Save button File name C Documents and Settings AdministratoriMy Documents isettingDataFile xls AS Main dialog F l Doaa S ale OS 8e ORS Isem arenei Edit or View button 13 4 2 Startup and exiting 4 2 1 Starting the software program Double click the DEF Make Tool icon on the desktop to start the software program The main dialog Fig 4 2 appears If the dialog of Fig 4 3 appears click Enable Macros
40. e cells except for Header indoor unit ID number on the blank line on the Indoor unit group definition sheet and press Indoor unit ID number issue to input indoor unit ID number automatically Input data in the Header indoor unit ID number column and press Header indoor unit object_id number to input data automatically in the object_id and Header indoor unit ID number columns Then press R C group indoor unit capacity code input to input data automatically in the Indoor unit capacity code to Power consumption through HA control interface columns For general purpose interfaces input data directly in Power consumption through HA control interface Then press R C group indoor unit capacity code input to input data automatically in the Indoor unit capacity code column etc Press Outdoor unit No input from Outdoor unit group definition sheet to input data automatically in the Outdoor unit No column A line can be inserted by clicking Insert Line on the menu bar To delete a indoor unit Update Indoor unit total Qty in the System Setting sheet Then select a cell in the line with an indoor unit you want to delete in the Indoor unit group definition sheet and click Edit Delete on the menu bar Select All lines on the dialog displayed and click OK to delete the indoor unit When Indoor unit model name is updated Press R C group i
41. e set here is also displayed in the Building name column on the Touch Sereen Controller screen 2 Word in error code definition file Choose 0 Japanese 1 English2 or 2 Chinese Simplified for the ERROR _CODE DEF language output 3 Touch Sereen Controller No Specify this when using two or more Touch Screen Controllers on a network When only one Controller is used leave this item as the default setting 1 Touch Screen Controller No 1 4 Intelligent Server Qty Specify the number of Intelligent Servers to be used 5 Indoor unit total Qty Specify the number of indoor units to be controlled For Digital Inverter Super digital Inverter equipment twin triple and group control system is counted as one unit 6 Daily report closing time meter read time Specify daily report closing time in the hh mm format Default 23 59 26 7 Monthly report closing date Specify monthly report closing date 8 Scheduled operation central setting Specify an operation mode for scheduled operation The following 4 patterns can be selected Setting OFF 10 minutes after OFF within 10 minutes ON No central setting OFF OFF ON Setting No 1 OFF ON OFF switching prohibition reset OFF ON OFF switching prohibition reset ON ON OFF switching prohibition reset Setting No 2 OFF ON OFF switching prohibition reset OFF ON OFF switching prohibited
42. each Intelligent Server Input correct number of interfaces beforehand in the System Setting sheet as the system equipment configuration table is automatically created based on the Intelligent Server Qty data in the System Setting sheet 6 2 1 Window Image EJ Setting File creation software Ver 2 00 Rev01 SettingDataFile xls iaj xj 6 file Edit view Insert Format Tools Data Window Help laj x OSES 4A e Az A mT 2 nun u B z u aam 8 2 A gt c2 OWA System equipment configuration general purpose input output in the touch par 0 N A a Intelligent Server number Not No No3 No4 Nos Nos No Nos Nod bh TCS Net Relay Interface Q ty 3 Digital O Relay Interface Q ty E Energy Monitoring Relay Interface Q El El Tp bi System Setting System equipment configuration Address Setting Blockmumberissue A Ar lt Ready ESI NUM J 6 2 2 Window Description 1 TCS Net Relay Interface Qty for use in Japan and overseas Specify the number of TCS Net Relay Interfaces connected to each Intelligent Server 2 Digital I O Relay Interface Qty for overseas use Specify the number of Digital I O Relay Interfaces connected to each Intelligent Server 3 Energy Monitoring Relay Interface Qty for overseas use Specify the number of Energy Monitoring Relay Interfaces connected to each Intelligent Server 6 2 3 Buttons No buttons are provided on this shee
43. ed to set 1 display for List display validity on all lines with a tenant name Delete duplicated tenant name Used to delete the line of duplication if any tenant name is duplicated Sort tenant name Used to sort Tenant name from the top 40 6 8 Fire alarm input definition sheet This sheet is used to set I O interfaces and input channels used for fire alarm inputs when using the fire alarm interlocking function No setting is required when fire alarm interlocking is not used 6 8 1 Window Image 2s Setting File creation software Yer 2 00 Rev01 SettingDataFile xls file Edit View Insert Format Tools Data Window Help OSHS 6RY sBBelo Sr 24 00 M5 ur Gothic Indoor unit equipment sheet update by input No Indoor unit equipment sheet update by input name Fire alarm Input device ID Input channel Signal logic input No 14 PZ Tenant number issue Fire alarm input def Door lock input def Emergency external output def 4 f Ready I NUM 6 8 2 Window Description 1 Fire alarm input name Input another n
44. egistered the model name can be selected from the model list displayed by Indoor unit model name in the Indoor unit group definition sheet and by Outdoor unit model name in the S MMS outdoor unit group definition sheet Furthermore parameters such as indoor unit capacity code can be input automatically Destination folder masterF ile wevonsaoasveensenscossenrsacnsoenvcogpsornsoosvereoorsooevsensosscsnn DefMake xls setting ini Language mst zee 4 N i ERROR_CODE_C DEF nile aR lack ie ERROR_CODE_E DEF a sgt ERA CHIE DEF Describes indoor outdoor unit model names and parameters 7 1 1 Registering indoor unit outdoor unit model names in Equipment model table Open unit table xls with Microsoft Excel Fig 7 1 E Microsoft Excel unit_table xls E ll x File Edit view Insert Format Tools Data Window Help la xj JOSE Sa S6R s BB o B 2 MG gt ava M35 gt A B c D E H G 1 Outdoor unit model name table MMY MAP0501T8 MMY MAPO601T8 MMY MAPO801 T8 MMY MAP1001T8 MMY MAP1201T8 MMY AP1401T8 MMY AP1601T8 MMY AP 180178 I MMY AP2001T8 MMY AP2201T8 MMY AP2211T8 MMY AP2401T8 MMY AP2411T8 MMY AP2601T8 MMY AP2801T8 MMY AP3001T8 MMY AP3201T8 MMY AP3211T8 MMY AP3401T8 MMY AP3411T8 MMY AP3601T8 MMY AP3611T8 MMY AP3801T8 MMY AP4001T8 I MMY AP4201T8 Outdoor Indoor Parameter Ready a T_T _homr Super MMS 1 1 1 1 1 2 2 2 2 3 2
45. ennvnnnnnenene 43 6 9 3 BUONG aso ennveeverenverrserdengneerdedaweinnerr a ade aci enten 44 6 10 Emergency external output definition sheet nennen nee ennnennnnennenennn 45 6 1 0 A Window Image narren entente weed een 45 6 10 2 Window Description eneen niii AE AEE Aa AEE EEE EE EE 45 6 10 3 ButtOns miina oT iair A A E tease chee a EE ee edn 46 6 11 Power meter input definition sheet nnnunnnnnnnnnenene nennen nennen 47 6 111 1 Window IMAG e cuado nnen 47 6 1 1 2 Window D amp seriptiOM arn eeetewevsdevene lle beeidende eet eb makende plas 47 6 1 1 3 BUTONS oen el rvan erneer neen ada patio 48 6 12 S MMS outdoor unit group definition sheet nnn ennen eener nennennenenneen 49 6 1251 Window Imagen nameten eeen eaten an eee ma 49 6 12 2 Window Description nnee eenneereeenenennsenreerennennenreenennanneenvenenenaneeevenenennnsenenenennnnnen 49 6 1 2 3 ButtONS ren reren vendetta dennen neten aleen 51 6 13 Indoor unit group definition sheet nnnnnnenenneennenenenenee nee nennnennnnnenenen 52 6 13 1 Window Mage vereer e wenden deden Avenant verde E A 52 6 13 2 Window Description menres en en ianen EEEn Ear AEE NEEESE E NEE ANAE rn rr naar rn rra ner EA ARAETA EEA E 52 6 13 3 Buttons vicio tie ia eee iaai OE ANA E weaved ae an eeen dee Aveda ew vaa dae 56 6 14 Outdoor unit group definition other than S MMS sheet nnn nnn nennen 5
46. ent when a door lock input turns ON positive logic or when it turns OFF negative logic 6 Write to setting file Specify whether to output data on the line to a setting file 43 6 9 3 Buttons Indoor unit equipment sheet update by door lock input No Used to update Door lock input name based on the Door lock input No data on the Indoor unit group definition sheet Indoor unit equipment sheet update by door lock input name Used to update Door lock input No based on the Door lock input name data on the Indoor unit group definition sheet 44 6 10 Emergency external output definition sheet This sheet is used to set I O interfaces and output channels used for emergency external outputs when using the emergency external output function Use external emergency output No 1 usually when the emergency external output function is used No setting is required when the emergency external output is not used 6 10 1 Window Image EJ Setting File creation software Ver 2 00 Rev01 SettingDatafile xls o laj xj Eile Edt View Insert Format Tools Data Window Help 18 x josh al4Rrl smelo zr yl a ms ur Gothic fils E l 9 A gt
47. his is necessary for the creation of setting files 3 2 Installation Insert the installation CD into the drive The setup operation starts automatically If it does not start execute SETUP EXE on the CD The Choose Setup Language dialog Fig 3 2 appears first Choose the language to be used for the software and Click OK The Welcome window Fig 3 3 opens next click Next gt The License Agreement dialog Fig 3 4 appears Read the license agreement and select I accept the terms in the license agreement and then click Next gt The window changes to the Destination Folder window Fig 3 5 Choose a folder in the installation destination default folder usually and click Next gt Click Install on the dialog Fig 3 6 that opens next Installation of the selected file starts The dialog Fig 3 7 appears during the installation and then changes to the InstallShield Wizard Completed window Fig 3 8 Click Finish on the window to complete the installation operation Choose Setup Language xj En Select the language for this installation from the choices below Y Fig 3 2 Choose Setup Language dialog 15 SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 InstallShield Wi xj 13 SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 x Welcome to the InstallShield Wizard for License Agreement SETTING FILE CREATION SOFTWARE Ver2 00 Please read the Following license agreeme
48. input data automatically in the Monthly report tenant No and List display validity columns Press Tenant input at once as required to input 2 tenant for Summing up category at a time Register one or more monthly report tenants Input data in the Tenant number issue sheet Firstly input all the tenant names to be registered in Tenant name Then press Tenant number issue and List display input at once to input the data automatically in the Tenant No and List display validity columns Choose a monthly report tenant name corresponding to the tenant name on the line from the list for the Monthly report tenant name When the entered monthly report tenant name is registered in the Monthly report tenant number issue sheet the tenant number is automatically entered into the Monthly report tenant No column Input data in the Fire alarm input definition sheet when using a fire alarm interlocking function Input Input device ID Input channel and Signal logic on the line of fire alarm input number to be used usually from line 1 and select 1 write for Output to setting file on the line If no data is input in the System Setting sheet and System equipment configuration sheet no list is displayed when Input device ID is selected Input data in the Door lock input definition sheet when using the door lock interloc
49. input data directly as appropriate values are input automatically by entering data in the TCS Net Relay Interface No column 11 node_id input prohibited Hexadecimal data to be described in setting files is displayed indicating line address Do not input data directly as appropriate values are input automatically by entering data in the Line address column 12 x1 input prohibited Hexadecimal data to be described in setting files is displayed indicating device type Do not input data directly as appropriate values are input automatically by entering data in the Outdoor unit model name column 13 x2 input prohibited Hexadecimal data to be described in setting files is displayed indicating device type Do not input data directly as appropriate values are input automatically by entering data in the Outdoor unit model name column 14 x3 input prohibited Hexadecimal data to be described in setting files is displayed indicating outdoor unit number Do not input data directly as appropriate values are input automatically by entering data in the Outdoor unit No column 15 Outdoor unit No input prohibited The outdoor unit number used for setting files on the line is displayed Outdoor unit numbers are issued automatically by pressing Outdoor unit number issue button 16 Power meter input No input prohibited Power meter input number corresponding to the value in the
50. is line when entering data in the Area name column in the Indoor unit group definition sheet 6 5 3 Buttons Area number issue Used to issue area numbers to the Area No column sequentially beginning with 1 Equipment setting sheet area number update Used to update Area No by finding an area number based on the Area name data in the Indoor unit group definition sheet Equipment setting sheet area name update Used to update Area name by finding an area name based on the Area No data in the Indoor unit group definition sheet 35 O List display input at once Used to set 1 display for List display validity in all lines with an area name Delete duplicated area name Used to delete the line of duplication if any area name is duplicated Sort area name Used to sort Area name from the top 36 6 6 Monthly report tenant name definition sheet This sheet is used to register monthly report tenant names Be sure to register one or more monthly report tenants This setting is only used when a monthly report is created 6 6 1 Window Image El Setting File creation software Ver 2 00 Rev01 SettingDataFile xls 9 xl Eile Edit view Insert Format Tools Data Window Help x jOseasai4aa seea OB fe AM E 2 mur cothic 0 B z u aam s E 2 0 A gt Monthly report tenantNo issue Tenant number issueSheet sMo
51. is sheet is used to input general system information such as building name and window display 6 1 1 Window Image El Setting File creation software Yer 2 00 Rev01 SettingDataFile xls E 15 xj Eile Edit view Insert Format Tools Data Window Help 18 x JD SE S S6RY SB o B A AME P msurcotnic zu B 7 1U Biv O A 2 gt setting File create o cc y System Setting Building name Words in error code definition file 1 English Touch Screen Controller No 1 Touch Screen Controller No 1 Intelligent Server Q ty 1 Indoor unit total Q ty Daily report closing time meter read time 23 59 Scheduled operation central setting 0 No scheduled operation central setting Door lock interlocking central setting energy monitoring 1 Valid Power meter pulse constant setting 1 Valid Stand by power counting 1 Propotional sharing on indoor unit horse power codes KW conversion coefficient 0 75 D Block Number of block display buttons 2 Number of tenant display buttons Number of area display buttons Number of R C group indoor display buttons Schedule setting unit 1 R C groupfindoor Filter sign display mode 1 display Back light save count minutes 10 a IM bi System Setting System equipment configuration Address Setting Block number issue Ar 4 Ready 6 1 2 Window Description 1 Building name Input a building name The nam
52. it group def Ex SMMS5 Outdox 4 f Ready NUM 6 13 2 Window Description Input items 1 Intelligent Server No Input Intelligent Server No corresponding to the indoor unit on the line 2 TCS Net Relay Interface No Input TCS Net Relay Interface address corresponding to the indoor unit on the line 3 Line address Input refrigerant line address of the indoor unit on the line 4 Indoor unit address Input indoor unit address of the indoor unit on the line 5 Header indoor unit ID number When the indoor unit on the line is a header unit set to 0 When it is a follower unit input the header indoor unit ID number 6 Indoor unit model name Specify indoor unit model name of the indoor unit on the line 52 7 R C group indoor name Specify R C group indoor name of the indoor unit on the line 8 Tenant name Specify tenant name to which the indoor unit on the line belongs 9 Area name Specify area name to which the indoor unit on the line belongs 10 Block name Specify block name to which the indoor unit on the line belongs 11 Door lock input name Specify a door lock input name when the indoor unit on the line performs door lock interlocking Select No setting when doo
53. k Click Cancel to Installshield Installshield Fig 3 5 Destination Folder window Fig 3 6 Ready to Install the Program dialog 10 SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 Installshield Be xi Installing SETTING FILE CREATION SOFTWARE er2 00 Revision01 InstallShield Wizard Completed The program features you selected are being installed Please wait while the InstallShield Wizard installs SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 This may take several minutes The InstallShield Wizard has successfully installed SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 Click Finish to exit the wizard InstallShield Fig 3 7 Installing dialog Fig 3 8 InstallShield Wizard Completed window 11 3 3 Uninstallation When the software is running close the software down completely Double click the Add Remove Programs icon in the Control Panel to open the Add Remove Programs dialog Fig 3 9 Choose SETTING FILE CREATION SOFTWARE and click Remove The Comfirmation dialog Fig 3 10 appears Click Yes to start un installing of the program Upon completion the dialog disappears automatically E Add Remove Programs lol x Currently installed programs Sort by Name z Change or Gee ote OND eet oh ee Remove Programs Dm Due tra nen wo Lo E AS af Add New Programs Add Remov
54. k name Door lock input name Fire alarm input name and Power meter input name in the follower indoor unit line are not used However if these items are left blank no setting file can be created Input the same data as header indoor unit Input data in the Outdoor unit group definition other than S MMS sheet When using Digital Inverter Super Digital Inverter units with energy monitoring Data must be entered in this sheet when using Digital Inverter Super Digital Inverter units or general purpose interface while using energy monitoring If energy monitoring is not used this sheet is not used irrespective whether it is completed or left blank Even when energy monitoring is used this sheet is not used either if no Digital Inverter Super Digital Inverter unit is used Click New first Outdoor units corresponding to all Digital Inverter Super Digital Inverter units registered in the Indoor unit group definition sheet are entered in each line in the table Enter the power meter input name corresponding to each outdoor unit in the Power meter input name column When you do not assign a power meter input select No setting When assigning power meter input to multiple outdoor units in a Digital Inverter Super Digital Inverter system make the cell in the line of the outdoor unit in the system active and click Insert Then a line of the second outdoor unit of the system is added to the table Repeat this operatio
55. king function Input Input device ID Input channel and Signal logic on the line of door lock input number to be used usually from line 1 select 1 write for Write into setting file on the line If no data is input in the System Setting sheet and System equipment configuration sheet no list is displayed when the Input device ID is selected 18 Input data in the Emergency external output definition sheet when using the external emergency output function Input Output device ID and Output channel on the line of an external emergency output number to be used usually line 1 and select 1 write for Write into setting file on the line If no data is input in the System Setting sheet and System equipment configuration sheet no list is displayed when the Output device ID is selected Only external emergency output No 1 is used usually Input data in the Power meter input definition sheet when using power meters Input Input device ID Input channel and Pulse constants kWh pulse on the line where a power meter input number is to be used usually from line 1 and select 1 write for Write into setting file on the line When specifying pulse constants by the Monthly Report Creation Software set Pulse constants kWh pulse in the System Setting sheet to N A In such case the Pulse constants
56. l icon on the desktop to start the program The main dialog opens Press File selection The File open dialog opens Select the Excel Workbook file for data input which was saved previously and press Open to reopen the main dialog Confirm that the selected file name is displayed under File name and then click Edit The selected Excel Workbook file is displayed and the program enters the data entry standby state 5 2 2 Updating data The following describes notes on updating data System Setting sheet e When Intelligent Server Qty data is updated Check the data in the System equipment configuration sheet first and then data in the Address Setting sheet e When I O kit Qty or Energy Monitoring Relay Interface Qty data is updated Check data input in the Address Setting sheet e When Stand by power counting data is updated Press R C group indoor unit capacity code input in the Indoor unit group definition sheet to update Indoor unit capacity code and other necessary items System equipment configuration sheet e When interface quantity is updated Check the data in the Address Setting sheet Address Setting sheet e When TCS Net Relay Interface No is updated in the Intelligent Server table at the bottom Press Header indoor unit object_id number in the Indoor unit group definition sheet to update object_id an
57. ld all deed ode ENa AGORA 32 6 4 Block number issue sheet nnnnnnnnsnssssssrrnnnrnnnnnnnnnnnaeeeeeeeeeerrrerererereeeeeerreeeeereenssns 33 6 4 1 WINDOW IMAGE tt ad di 33 6 4 2 Window Descriptions seia ean e a ls iio 33 6 4 3 Buttons iii a Deeb ev ah eto 33 6 5 Area number issue SNES iii rra id 35 6 5 1 WINdOW Image nn arten retard ae i Sega eden didnt 35 6 5 2 Window Description dende 35 6 5 3 BUONS Treinen e 35 6 6 Monthly report tenant name definition sheet nennen en eennennennnnneneenn 37 6 6 1 Window Image nnen a TE A E a a TA AER ASE AEN T 37 6 6 2 Window Description scenie entane iaai nna aaia AEA aE AN AiE EAEAN an aTa AA i anea 37 O ART 38 6 7 Tenant number issue SNES team i hann dane 39 6 7 1 WINDOW IMAGO ziee interneren denkenden as 39 6 7 2 Window Description nnnneeeeeeeneeneeeeeeennnnneerenennneneeerenenenenneerenennnenneerenennnnnverseneennnnneen 39 62723 BUUONS batas 39 6 8 Fire alarm input definition sheet unuunsnnsensennnnrenensennnneensneennnnennsenennnn 41 6 8 1 Window IMAJS gt iai Ri 41 6 8 2 Window DESCI UON caian iran 41 6 823 BUTON S ardido lalala 42 6 9 Door lock input definition sheet cccccoconcncnnccccnncnncnnnononcnnnonnnncnnnnonanencnnnnnnoncnnninnns 43 6 9 1 Window IMAGE annonseringer ad a ene 43 6 9 2 Window Description anneer eneneneeevenenenennenveneneneneenvensnenanneevensnennnenvenenennneer
58. le type setting dialog Fig 7 5 opens 62 Specify a character code and the applicable signal logic used for the output setting file When English Chinese is selected for character code the setting file is output in Unicode Select this to create a setting file for overseas air conditioning control system Select Signal logic applicable when performing fire alarm door lock interlocking using the Digital I O Relay Interface Select Signal logic N A for use in Japan where a Digital I O Relay Interface is not used File type setting x Select the language Character code m Signal logic Japanese Signal logic applicable English Chinese C Signal logic N A OK Cancel Fig 7 5 File type setting dialog Click OK on the dialog The setting file is output to the specified folder Upon completion of the setting file output the following dialog Fig 7 6 opens Click OK on the dialog to close the output procedure microsoft Excel HE Completed Fig 7 6 Setting file output completed dialog 63 TCS NET Air conditioning Control System Setting File Creation Software Version 2 00 User s Manual June 2005 First Edition 2005 08 09 Fourth Edition TOSHIBA CARRIER CORPORATION
59. n to register three or more outdoor units in the system 20 5 Create a setting file Open the System Setting sheet and press Setting File create For details of the Setting File create button see 7 2 Upon completion of the data checking the following dialog appears Microsoft Excel En xi Data checking has Completed And now start to make DEF files Fig 5 1 Data checking completed dialog Click OK on the dialog The folder selection dialog appears Choose a setting file output folder and click OK The file type setting dialog appears Specify a character code and signal logic on the dialog In principle select Signal logic N A when a Digital I O Relay Interface is not used File type setting 1 xj Selectthe language Character code m Signal logic Japanese Signal logic applicable English Chinese C Signal logic NIA OK Cancel Fig 5 2 File type setting dialog Click OK on the dialog The selected setting file is created in the specified folder Save Excel Workbook files for data input in the same way as normal Excel Workbook files Excel Workbook files for data input can be saved at any time Exit the program Click the X button at the upper right of the window to close the window The software program can be exited at any time 21 5 2 Setting file update 5 2 1 Starting the program Double click the DEF Make Too
60. ndoor unit capacity code input to input data automatically in the Indoor unit capacity code to Power consumption through HA control interface columns For general purpose interfaces input data directly in Power consumption through HA control interface Press R C group indoor unit capacity code input to input data automatically in the Indoor unit capacity code column etc Then press Outdoor unit No input from Outdoor unit group definition sheet to input data automatically in the Outdoor unit No column 24 e When the Intelligent Server No TCS Net Relay Interface No Line address Indoor unit address or Header indoor unit ID number is updated Press R C group indoor number issue to re issue R C group indoor No Then press Header indoor unit object_id number to input data automatically in the object_id and Header indoor unit ID number columns Then press R C group indoor unit capacity code input to input data automatically in the Indoor unit capacity code to Power consumption through HA control interface columns For general purpose interfaces input data directly in Power consumption through HA control interface Press R C group indoor unit capacity code input to input data automatically in the Indoor unit capacity code column etc Then press Outdoor unit No input from Outdoor unit group definition sheet to input
61. nt carefully Revision01 The InstallShield R Wizard will install SETTING FILE CREATION E SOFTWARE Ver2 00 Revislon01 on your computer To TOSHIBA CARRIER SOFTWARE LICENSE AGREEMENT continue click Next IMPORTANT PLEASE READ TERMS AND CONDITIONS OF THIS AGREEMENT CAREFULLY BEFORE USING SETTING FILE CREATION SOFTWARE HEREINAFTER CALLED THE SOFTWARE BY USING OR INSTALLING A WHOLE OR A PART OF THIS SOFTWARE YOU HEREINAFTER CALLED USER ARE DEEMED TO ACCEPT ALL THE WARNING This program is protected by copyright law and TERMS AND CONDITIONS OF THIS AGREEMENT IF USER DO NOT international treaties AGREE TO THESE TERMS AND CONDITIONS DO NOT USE OR INSTALL THE SOFTWARE AND RETURN TO THE LOCATION FROM murron TT mae APTATMEN 1 accept the terms in the license agreement Print o A coe eej Fig 3 4 License Agreement dialog 113 SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 InstallShield xj 113 SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 x Destination Folder Ready to Install the Program Click Next ta install to this folder or click Change to install to different folder The wizard is ready to begin installation Install SETTING FILE CREATION SOFTWARE Ver2 00 Revision01 to Click Install to begin the installation C Program Files TOSHIBA z CARRIER SettingFileCreationSoftwareVer2 Change yyol pelo review or change any of your installation settings click Bac
62. nthly report tenantNo UpDate Tenant number issueSheet sMonthly report tenantName UpDate Sort name Tenant input at once Suming up category Total List display validity Division Ha rid Address Setting Block number issue Area number issue Monthly report tenant name def 4 Ready 6 6 2 Window Description 1 Monthly report tenant number A unique number assigned to each monthly report tenant name Monthly report tenant numbers can be issued by pressing Monthly report tenant number issue button 2 Monthly report tenant name Input a tenant name to be used for the monthly report 3 Summing up category Specify a section to be displayed when a monthly report is created Choose 0 N A 1 Common use area or 2 Tenant Choose 2 Tenant usually 4 List display validity Specify whether to display the monthly report tenant name on this line when entering data in the Monthly report tenant name column in the Tenant number issue sheet 37 6 6 3 Buttons Monthly report tenant number issue Used to issue tenant numbers to the Monthly report tenant No column sequentially beginning with 1 Monthly report tenant number update in tenant number issue sheet Used to update Monthly report tenant No by finding a monthly report tenant number based on the Monthly report tenant name data on the Tenant number issue sheet 3 Monthly rep
63. ormat Tools Data Window Help laj xi DSRS SRY s AnA A 21 00 gt vsucane vorlBzul sls s 8 E 0 A gt Blockno issue Indoor settingSheet sBlockNo UpDate Indoor settingSheet sBlockName UpDate List display input at once Delete duplicated name Sort name c3 X Al B E a EC r a aS i EN ij Al 1 Block number issue Block Block nome List disploy volidity dlp pi System Setting System equipment configuration Address Setting Block number issue ar 4 Ready 6 4 2 Window Description 1 Block No A unique number is assigned to each block name Block numbers can be issued by pressing Block number issue button 2 Block name Input a block name to be displayed on the Touch Screen Controller screen 3 List display validity Specify whether to display the block name on this line when entering data in the Block name column in the Indoor unit group definition sheet 6 4 3 Buttons Block number issue Used to issue block numbers to the Block No column sequentially beginning with 1 Equipment setting sheet block number update Used to update Block No by finding a block number based on the Block name data in the Indoor unit group definition sheet Equipment setting sheet block name update Used to update Block name by finding a block name based on the Block No data in the Indoor unit group definition
64. ort tenant name update in tenant number issue sheet Used to update Monthly report tenant name by finding a monthly report tenant name based on the Monthly report tenant No data on the Tenant number issue sheet List display input at once Used to set 1 display for List display validity on all lines with a monthly report tenant name Delete duplicate monthly report tenant name Used to delete the duplicated line if any monthly report tenant names are duplicated Sort monthly report tenant name Used to sort Monthly report tenant name 38 6 7 Tenant number issue sheet This sheet is used to register tenant names Be sure to register one or more tenants 6 7 1 Window Image El setting File creation software Ver 2 00 Rev01 SettingDataFile xls E 9 x Bile Edit view Insert Format Tools Data Window Help i la xi OSES 4B e z slm Zj vuren 0 B z u as e x E d A 7 TenantNo issue Indoor settingSheetsTenantNo UpDate Indoor settingsheetsTenantivame UpDate List display input at once Delete duplicated name Sort name c3 al A Bal 5 I D E F EE TI J KIA 4 Tenant number issue Tenont No Tenant nome Monthly repor tenant Monthly report List disploy volidily nome tenont number le ON E N 0 MTD PZ Area number issue __ Monthly report tenant name def Tenant number Ready 6 7 2 Window Descrip
65. r issue sheet Tenant number issue sheet Same as Block number issue sheet Fire alarm input definition sheet e To increase input Input the necessary data such as input device ID in the line where fire alarm input number you want to set is displayed and select 1 write for Write into setting file on the line e To decrease input to invalidate currently valid input Select 2 no write for Write into setting file in the line where fire alarm input number you want to invalidate is displayed e When Fire alarm input name is updated Press Indoor unit equipment sheet update by fire alarm input No button to update Fire alarm input name in the Indoor unit group definition sheet When the button is pressed Fire alarm input No in the same sheet is also updated 9 Door lock input definition sheet Same as a Fire alarm input definition sheet Emergency external output definition sheet e To increase output Input necessary data such as output device ID on the line of the target output number and then select 1 write for Write into setting file e To decrease output Select 2 no write for Write into setting file in the line where the external emergency output number you want to invalidate is displayed Power meter input definition sheet Same as Fire alarm input definition sheet 23 2 S MMS outdoor unit
66. r lock interlocking is not used 12 Fire alarm input name Specify a fire alarm input name when the indoor unit on the line performs fire alarm interlocking Select No setting when fire alarm interlocking is not used 13 Power meter input name Specify a power meter input name corresponding to the indoor unit on the line when using energy monitoring Select No setting when energy monitoring is not used 14 Write to setting file When 2 no write is selected in this column the indoor unit data on the line is not written in the AC_MAP DEF AC_GROUP DEF or listOfApparatus txt file 15 Power consumption through HA control interface Input appropriate power consumption through HA control interface in this column when the model name on the line is a general purpose interface If the model name on the line is MMS or a Digital Inverter Super digital Inverter model O is input automatically by pressing R C group indoor unit capacity code input button requiring no data input When energy monitoring is not used data input is not required 16 Power consumption through HA control interface indoor unit group for use in Japan only Input appropriate power consumption through HA control interface of indoor unit group in this column when the model name on the line is a general purpose interface If the model name on the line is MMS or Digital Inverter Super Digital Inverter model O is input automatically by p
67. ressing R C group indoor unit capacity code input button requiring no data input When energy monitoring is not used data input is not required 17 Power consumption through HA control interface outdoor unit group for use in Japan only Input appropriate power consumption through HA control interface of outdoor unit group in this column when the model name on the line is a general purpose interface If the model name on the line is MMS or Digital Inverter Super Digital Inverter model O is input automatically by pressing R C group indoor unit capacity code input button requiring no data input When energy monitoring is not used data input is not required Input prohibited items 18 Header indoor unit ID number input prohibited Hexadecimal data to be described in setting files is displayed indicating indoor unit group data Do not input data directly as appropriate values are input automatically by pressing Header indoor unit object_id number button on the Indoor unit group definition sheet 53 19 object_id input prohibited Hexadecimal data to be described in the setting files is displayed The data is unique to each of all the interfaces and units connected to the Intelligent Server Do not input data directly as appropriate values are input automatically by pressing Header indoor unit object_id number in the Indoor unit group definition sheet 20 net_id input prohibited Hex
68. ss is used to identify each outdoor unit when multiple outdoor units of the same system are registered This address is entered automatically by clicking New or Insert 6 14 3 Buttons New Used to automatically input data of the system that is not registered in the table in the Outdoor unit group definition other than S MMS sheet among Digital Inverter Super Digital Inverter units and general purpose interfaces registered in the Indoor unit group definition sheet in a line for each system When energy monitoring is not used when 0 None is selected for Energy monitoring in the System Setting sheet this button does not function as you do not need to enter data on this Outdoor unit group definition other than S MMS sheet Add lines Used to add a new line for the system on the line where a cell is active Use this button to assign power meter input to multiple outdoor units in the system of a Digital Inverter Super Digital Inverter unit or general purpose interface 58 7 Notes 7 1 Equipment model table unit_table xls The model lists displayed by Indoor unit model name in the Indoor unit group definition sheet and by Outdoor unit model name in the S MMS outdoor unit group definition sheet are described in the unit_table xls file Registration of new model names and model name parameter change are made possible by editing this file Once a model name is r
69. t 29 6 3 Address Setting sheet This sheet is used to specify the interface number of each device to be connected Input correct data beforehand in the System Setting and System equipment configuration sheets as the address setting table is automatically created based on the data entered in these sheets 6 3 1 Window Image EJ Setting File creation software er 2 00 Rev01 SettingDataFile xls y 15 xj GI File Edit View Insert Format Tools Data Window Help laj x Eer E E AME 2 va so sle aU E D226 zl Address Setting Equipment category IP address Touch Screen Controller 192 168 2 69 Intelligent Server number IP address Equipment category PLR No 1 192 168 2100 Lel Digital KO Relay Interface No 2 192 168 2107 TCS Net Relay Interface ergy Monitoring Relay Interfa No 3 192 168 2 102 i 1 7 No 1 i Digital I O Relay Interface No 7 i No 1 1 ergy Monitoring Relay Interfal No 7 7 lal oi System Setting System equipment configuration Address Setting Block number issue Ar 4 Hr Ready TE NM 6 3 2 Window Description The uppermost table 1 Equipment category input prohibited Equipment names are listed Do not input data directly in this column 2 Unit number input prohibited Equipment numbers are listed Do not input data directly in this column 3 IP address input prohibited Equipment IP addresses are listed Do
70. t 0 for multi system models or 1 for Digital Inverter Super Digital Inverter models Model name Input the outdoor unit model name to be registered Input a set model name for Digital Inverter Super Digital Inverter models Total indoor unit capacity code HP Total indoor unit fan motor capacity kW Total indoor unit heater capacity kW Input parameters of the models to be registered Total outdoor unit crankcase heater capacity kW Input 0 for multi system models For Digital Inverter Super Digital Inverter models input the total outdoor unit crankcase heater capacity in kW Indoor unit Qty Input 1 for single indoor unit model name For indoor units with set model name input the number of indoor units defined by the set model name 60 Outdoor unit Qty Input 0 for multi system models For Digital Inverter Super Digital Inverter models input the number of outdoor units defined by the set model name Indoor unit object management No Input OFO1 for multi system models Input OF88 for Digital Inverter Super Digital Inverter models Outdoor unit object management No Input FFFF Domestic overseas Date of addition Outdoor unit model name and Indoor unit model name You need not input data for these items Use for reference When input of these items is completed overwrite save the unit table xls
71. tion 1 Tenant No A unique number assigned to each tenant name Tenant numbers can be issued by pressing Tenant number issue button 2 Tenant name Input a tenant name to be displayed on the Touch Screen Controller screen 3 Monthly report tenant name Input a monthly report tenant name corresponding to the tenant on the line 4 Monthly report tenant number input prohibited Monthly report tenant numbers corresponding to respective monthly report tenant name on each line are displayed You need not input data in this column because data is automatically input by finding a tenant number from the Monthly report tenant name definition sheet when a monthly report tenant name is entered 5 List display validity Specify whether to display the tenant name on this line when entering data in the Tenant name column on the Indoor unit group definition sheet 39 6 7 3 Buttons Tenant number issue Used to issue tenant numbers to the Tenant No column sequentially beginning with 1 Equipment setting sheet tenant number update Used to update Tenant No by finding a tenant number based on the Tenant name data in the Indoor unit group definition sheet Equipment setting sheet tenant name update Used to update Tenant name by finding a tenant name based on the Tenant No data in the Indoor unit group definition sheet List display input at once Us
72. unit group definition sheet This sheet is used to input various setting data of indoor units For Digital Inverter Super digital Inverter indoor units input data for header indoor unit only and input a Digital Inverter Super digital Inverter set model name for Outdoor unit model name For HA control interfaces select General purpose interface for Outdoor unit model name When using energy monitoring input appropriate values in the Power consumption through HA control interface column 6 13 1 Window Image El Setting File creation software Yer 2 00 Rev01 SettingDataFile xls laj xj gie Edt view Insert Format Tools Data Window Help la xj O SR S SR BB 0 6 A AMD zj nue 10 B Z u Sjans E _ d0 A gt fr C groupfindoor unit capacity code input R C group indoor unit No issue Outdoor unit No input from Outdoor unit group definition sheet 1 write input at once x B Aaa aaa 1 J K E M N 0 mn fs Header obj id net id node ij x1 x2 x3 Intellige TCS Line Indoor Indoor Header Indoor unit model R C group R C group Outdoor indoor d nt Net address unit unit 1D indoor unit name findoor indoor unit No unit 1D Server Rela address number ID number No name 14 PIZ Power meter input def SMMS Outdoor unit group def Indoor un
73. update by input No Indoor unit equipment sheet update by input name LAT B Cc 1 Power meter input def Power meter input name INEST NAMENI INPUT NAM INPUT NAMEO3 INROTNAMEDS INPUT NAMES INPUT NAME16 INPUT NAMEIT INPUT NAME18 INPUT NAME19 INPUT NAME20 INPUT NAME INPUT NAME25 INPUT NAME 26 Input device ID MS UI Gothic 10 BZ U ll xl EIER A Input channel Pulse constants kWhipul Output to setting file 0 no write 0 no write D no write 0 no write 0 no write 0 no write 0 no write O no write 0 no write 0 no write D no write 0 no write D no write 0 no write 1 0 no write O no write O no write 0 no write i T En INPUT NAME22 no write INPUT NAME23 D no write INPUT NAME24 D no write INPUT NAME27 INPUT NAME 28 INPUT NAME29 0 no write 0 no write 0 no write PEA 6 11 2 Window Description 1 Power meter input name Input another name for a power meter input number This name is used on the Indoor unit group definition sheet 2 Power meter input No input prohibited Power meter input numbers are displayed in this column Do not update these numbers 3 Input device ID Specify a device ID corresponding to the power meter input number on the lin
74. write input at once Used to specify 1 write in all the lines of Write into setting file 56 6 14 Outdoor unit group definition other than S MMS sheet When using Digital Inverter Super Digital Inverter units or general purpose interface with energy monitoring this sheet is used to specify power meter input corresponding outdoor units of Digital Inverter Super Digital Inverter unit or general purpose interface Data must be entered in this sheet when using Digital Inverter Super Digital Inverter units or general purpose interface while using energy monitoring If energy monitoring is not used this sheet is not used irrespective whether it is completed or blank Even when energy monitoring is used this sheet is not used either if neither Digital Inverter Super Digital Inverter unit nor general purpose interface is used 6 14 1 Window Image tion software er 2 00 Rev01 SettingDatafile xls lelx file Edit View Insert Format Tools Data Window Help ll xl DERA any tene 2 i Zj murene 10 B2U E eSB 8 o A Update Add selected line D3 y A Cam F G H a a EE na 4 Ex SMMS Outdoor unit group def Device R C group in Power meter Write into Power meter Outdoor unit model Outdoor unit type door No input name mn file input No name address FN is alaeo or on gt eo r 13 t4 41 gt PIZ stams Outdoor unit group def Indoor unit group def DE Ready
75. y external output definition sheet 11 Power meter input definition sheet 12 S MMS outdoor unit group definition sheet 13 Indoor unit group definition sheet 14 Outdoor unit group definition other than S MMS sheet Do not input data in the R C group indoor unit No manage sheet ONOaRWN Input data in the white cells of the table on each sheet 16 5 1 New file creation 5 1 1 Starting the program Double click the DEF Make Tool icon on the desktop to start the program The main dialog opens Click New The Save As dialog opens Specify the destination and the name of the Excel Workbook file for entering setup data Click Save The specified Excel Workbook file opens and is ready for data entry 5 1 2 Creating a new file Input data in the following procedure Input data in the System Setting sheet Data must be entered for all items except kW conversion coefficient in the table For details of each item refer to 6 1 in this manual Notes on the System Setting sheet e Setting numbers for the scheduled operation central setting items Scheduled operation ON OFF patterns vary depending on the setting Setting OFF 10 minutes after OFF within 10 minutes ON No central setting OFF OFF ON Setting No 1 OFF ON OFF OFF ON OFF ON ON OFF switching switching prohibition reset switching prohibition reset prohibition reset