Home
GJD830R D-TECT R Ricochet Enabled Wireless Installation Manual
Contents
1. unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or zi ce ae dispose of it at designated collection points For more information see www recyclethis info Contact information Web www gjd co uk Tel 44 0 1706 363 998 Email sales gjd co uk September 2013 Rev 4
2. IMPORTANT INFORMATION To fully utilize the GJD D Tect Unit with Texecom Ricochet Monitoring Software please upgrade your monitoring software via the Texecom website to the Version 2 18 0 or later q p J E O Q Jet Si a SSE RICOCHET GJD830R D TECT R Ricochet Enabled Wireless Installation Manual Compatible with Premier Elite control panel with firmware V2 08 and above The D TECT Ricochet MUST be learnt to the control panel BEFORE it is mounted in its final location Please see page 4 of this manual and Premier Elite INS467 5 for details 1 2 1 Batteries RALLOARP RAPPERS SEER PADENA PA APINN DDD RE RPREL ELAR AD RAR RDO mm PEA Page 1 of 4 2013 GJD Manufacturing Limited September 2013 Rev 4 All rights reserved Page 2 of 4 15 10 10 15 5 10 15 20 25 30 Beam Pattern set to maximum range Masking top section of lens will reduce range to 20 metres SS ONG RANGE EI METRE SECTION 5 ai 1000D pedi TM MASK THIS SECTION OFF FOR PET ALLEY APPLICATIONS UP TO 30 METRES 0 2 4 6 8 10 12 14 Beam Pattern set to minimum range Masking top section of lens will reduce range to 6 metres 10 20 30 September 2013 Rev 4 Packaging The package contains e 1x wireless detector e 3x wall plug amp screw sets e 1x lens mask e 2x additional curtain shutters 1x tamper cup e 2x tamper caps different lengths e 1x plastic opening tool e 1x i
3. base d Tighten the locking screw Batteries Only use CR123 3 V Lithium batteries Observe correct polarity when fitting Battery safety information e Do not putin a fire e Do not charge e Do not heat e Do not short circuit e Do not disassemble e Only fit batteries of the same type and voltage To preserve battery life the zone mode must be programmed to be Auto which introduces a 3 minute sleeptime Beam alignment and masking The multifunction lens fitted to the GJD830R detector focuses seven long range and seven medium to short range curtain beams The circuitry detects changes in heat and movement in the beam pattern The presence of trees shrubs ponds boiler flues black tarmac and animals should be considered when positioning the detector PIR sensors are more sensitive to movement across the beams and less sensitive to movement directly towards or away September 2013 Rev 4 The detector is fitted with two sliding shutters to reduce the detection angle The shutters are clipped to the pan and tilt module as shown in Figure 5 Each vertical section of the Fresnel lens gives a coverage pattern of approximately 10 degrees An additional set of shutters is provided for further adjustment Figures 7 8 and 9 show typical beam patterns A pet alley can be created my applying the lens mask as shown in Figure 9 Programming Figure 10 shows the position of the programming button 2 and the programmi
4. nduct walk tests with the cover removed The range of the detector increases without the protective front cover Therefore the front cover must be fitted to establish the correct beam pattern Adjust the range as necessary Pan and tilt the detector module over the field of view to obtain the correct coverage Specifications Detection range Programmable 10 20 or 30m Coverage 10 to 70 detection angle 30 x 25m coverage max Adjustment 180 pan 90 tilt Fresnel lens 28 zones for each detection element which can be masked with the curtain sliders Optics Double silicon shielded quad element eliminates 50 000 Lux of white light LED Red alarm Batteries 2x 3 V CR123 Current 50 pA Pulse count 1 or 2 Control Digital micro with non volatile memory Walk test Output test mode with LED indication Operating temperature Housing Dimensions W x H x D Weight Mounting height Compliance Manufacturer 25 to 65 C High impact ABS plastic with HDPE cover UV stabilised 145 x 145 x 120mm 268g Net 425g Gross Variable up to 6m Optimum height 3m GJD Manufacturing Limited Unit 2 Birch Business Park Whittle Lane Heywood Lancashire OL10 2SX UK Certification E R amp TTE This device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Environmental IP65 class 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as
5. ng LED 1 Table 1 Programming settings Option 1 2 3 1 Range m 10 20 30 2 Pulse count 1 2 Default settings Pulse count is the number of detections before signalling an alarm Pulse count 1 is most sensitive Changing settings 1 Press the programming button once for range and twice for pulse count 2 Wait until the programming LED turns off typically 4 seconds 3 Count the number of times the LED flashes to determine the current value for that option 4 Press the programming button to select the value number for the new setting E g to change the range to 20m press twice The LED blinks twice to indicate that the new value was set Programme settings are stored in non volatile memory Resets 1 Remove the batteries 2 Press and hold the programming button See Figure 10 item 2 3 Refit the batteries 4 After the programming LED has flashed release the programming button Learning to control panels When the control panel is in learn mode press the detector programme button once After about 10 seconds the wireless detector will be learnt on to the control panel Walk test In walk test mode the detection LED option is set to ON and the detection LED will illuminate on detection Page 4 of 4 To enter the walk test mode press the programming button once The unit can now be aligned Walk test mode ends automatically five minutes after the last detection Do not co
6. nstallation manual e 1x drilling template for fixing holes GJD s Ricochet enabled D TECT The wireless detector uses a quad pyro where both sensors must trigger to cause the detector to signal an alarm ensuring precise and reliable presence detection Programmable options include a variable pulse count and a choice of detection ranges up to 30 meters The dual axis tilt sensor allows 180 of pan and 90 of tilt This increases the speed of the outdoor installation and provides accurate aiming of the detection pattern Precision electronics digital white light filtering and double shielding eliminates false alarms from the sun The detector housing has a professional appearance with the sensing module hidden behind the front cover Quick installation 1 Place two CR123 batteries into the detector battery holders Observe the polarity See figure 4 item 1 The detection LED will flash four times 2 With the Ricochet expander in commission mode enter the learning menu on the control panel To learn the device follow the instruction given in the control panel documentation 3 Press and release the programming button once to learn the device Fig 10 item 2 This action also activates walk test mode Note The learn process may take up to 10 seconds from pressing the programming button Learn will be confirmed on the control panel 4 The detector will take approximately 3 minutes to settle The detection LED is no
7. w enabled for five minutes 5 Mount the detector following the instructions below Note To carry out a walk test the zone mode must be programmed to be Always Awake and the front cover must be fitted and secured The default settings are e Range 30 meters e Pulse count 1 Fitting the detector Protect the electronics against water Trapped moisture can affect or damage the unit Mounting holes should be sealed from within the detector using acrylic non silicone based sealants Silicone sealants must not be used as vapours may corrode the electronics and metal parts Ensure the detector s field of view is unobstructed Mounting the detector 1 Drill the wall to accept the fixing screws and the tamper cup if used See Figures 1 and 3 A hole drilling template is provided Notes e Use the tamper cup on uneven surfaces e Optimum height for the detector is 3m Higher mounting heights will result in reduced detection range 2 Remove the cover assembly using the plastic opening tool and by loosening the locking screw See Figure 2 3 Screw the unit to the wall Ensure the tamper pin is correctly located and the tamper switch is closed Two different length tamper feet are provided for uneven surfaces The tamper foot is a push fit see Figure 1 4 When the detector is aligned powered and programmed a Fit the cover b Loosely tighten the locking screw c Push the two side plastic latches into the
Download Pdf Manuals
Related Search
Related Contents
GBP301W3 Spanish manual.p65 Jensen KT7015A User's Manual WindChaser Products PACRWC-HP Air Conditioner User Manual Betriebs- und Montage- anleitung Stellantrieb Typ DMA Q5K-YSK-001-X04 Technique & information Hitachi 50UX58B 50" Rear Projection Television IBM Unica Distributed Marketing: Installationshandbuch Copyright © All rights reserved.
Failed to retrieve file