1. GJD SAPPHIRE MK3 LIGHTING CONTROLLER INSTALLATION MANUAL PART NO GJDO05 THE GID SAPPHIRE IS A SINGLE AREA SECURITY LIGHTING CONTROLLER WHICH ENABLES EXTERNAL AREAS TO BE ACCURATELY MONITORED IT AUTOMATICALLY SWITCHES UP TO 1500 WATTS OF RESISTIVE LIGHTING AT NIGHT FOR A PRE SET PERIOD AND CAN BE MANUALLY OVERRIDDEN WHEN REQUIRED THE CONTROLLER INCORPORATES AN AUDIDLE WARNING TONE AND FEATURES FOUR DETECTOR INDICATORS WHICH ILLUMINATE WHEN ACTIVATED BY DETECTION DAY AND NIGHT SPECIFICATION SUPPLY 230Vac 50Hz via ELCB MCB unit fused at 10A 12VDC 100mA GID Opal XL 6mA or Elite Detectors OmA Optional external12VDC piezo sounder upto 50mA LOAD Each Sapphire Controller can switch up to 1500W of resistive load or 1000W of inductive load The inductive load may require a snubber suppressor to manage the lamp discharge current INDICATION Four 24 hour detector indicators which pulse during detection and are steady _ after detection for the duration of the light on timer setting AUDIBLE Internal warning tone which sounds on detection day and night and is button selectable CONTROL Controls up to 8 x GID detectors Switches one area of lighting with manual override when required OPTIONS Ability to activate lighting with remote push button Ability to have an auxiliary output Ability to activate lighting when linked to an intruder alarm panel DIMENSIONS 146 W x 86 H x S6 D mm Weig
2. Max DUAL CABLE SINGLE CABLE LAMPING CLAMPING Low voltage connections Cable 4 6 core 7 0 2mm GJD SAPPHIRE MK3 OPTIONAL PIEZO SOUNDER 7 p T i watas tt RELAY DIODE spend 184002 fet 42VDC 60mA MAX A ee a OPTIONAL el BUTTON 0 ET FSL 0H 9m 9 O tO O 3 4 ZONE 1 GJD DETECTORS 1 Remote triggering of lights for the timer p 2 Activate zone lighting for alarm period All diodes IN4148 IN4002 etc eriod Pulse Count 1 must be selected when linked to an intruder alarm panel Caution if this equipment is intended for applications not specified please contact GID prior to installation GID Reserve the right to alter the specification without notice Technical 01706 363990 Sales 01706 363998 Fax 01706 363991 Email info gjd co uk GID Manufacturing Limited
3. ht 495gm MOUNTING Indoor use only Mount in a clean dry location on a secure flat surface TEMPERATURE 10 to 55 Centigrade C Self contained Class 2 independently mounted control OPERATING INSTRUCTIONS When a detector is activated day or night the relevant detector indicator flickers and will remain on for the length of the timer setting During darkness the lighting will be switched on automatically while the detector is receiving activation signals and will automatically turn off after the preset timer period The Zone green indicator has to be selected for automatically controlled lighting on detection during darkness E Green indicator is on This mode must be selected for automatic ZONE 1 lighting during darkness Indicator off Lighting and tone are switch off Green indicator flashing A detector has activated the lighting Manually selecting this yellow indicator will turn the lighting on Turning the indicator off will return to automatic mode Indicator off Yellow indicator flashing A detection has automatically activated the lighting Red indicator on Audible warning tone selected Zone 1 indicator to be selected to function Indicator off Audible warning tone is switched off ADJUSTMENT TO FACTORY SETTINGS When connecting the unit to the electrical supply or when the supply is interrupted the indicators will flash for one minute whi
4. lst the system settles Pressing any button during this time will start normal operation Internal adjustments panel 3 The factory settings are shown 3g 19 0 1 Ce 24 TO 3 F LIGHT ON PULSE TIME MINS COUNT LIGHT ON TIME IN MINUTES 1 to 24 The length of the light on time after last detection during darkness minutes The red detector indicators will stay on for this time after the last detection day and night Purse Count Walk test Select this symbol to assist in location alignment of the detector beams during daylight installations When the detector beams are activated the external lights will stay on for a period of 6 seconds 1 2 or 3 After completing the walk test function set the pulse count to the required level The pulse count is the number of detector beams that have to be crossed to trigger the system 1 will give a fast response 2 gives better immunity with good response 3 gives highest immunity to false activations in poor environments but is less responsive CAUTION To BE INSTALLED BY QUALIFIED PERSONNEL ONLY OPTIONAL TRIGGER LIGHTS IN ALARM CONDITION Mains voltage connections Cable 1 5mm flat twin earth open contact PLUG TYPE FUSE i i SLEEVED EARTH CABLES Ten aD E ioa i BASE 4 H 42VDC CONNECTIONS LOAD 16 E00VA MAX MAINS LIVE O po SUPPLY aaa poo N o A senessno 9 24 H 4 12000 z H 400mA N e Jecccevenecseoses

Download Pdf Manuals

image

Related Search

Related Contents

Dataflex ViewMate Ecoline Monitor Arm 232  Guía del usuario para audífonos Max™ retroauriculares    Netgear MBR1310 User Guide  Makita 4100NH Use and Care Manual  Samsung 23 liter  Brother 2400 Printer User Manual  VIP-254NT User`s manual - PLANET Technology Corporation.  JTAE115/315 取扱説明書  この商品の取り扱い説明書はこちら  

Copyright © All rights reserved.
Failed to retrieve file