1. www prolight co uk PERFORMER 36 RGB Order code LEDJ251 USER MANUAL Performer 36 RGB Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Performer 36 RGB Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment an
2. Performer 36 RGB is a DMX 512 controllable full RGB colour mixing Par Can made up of high efficiency LED s There are three colour groups red green and blue whose intensity can be controlled individually allowing the creation of an unlimited range of colours The Performer 36 RGB will operate in stand alone master slave sound activated and DMX 512 control modes DMX mode To select DMX mode press the MENU button to show D001 on the display Now press the ENTER button and use the UP and DOWN buttons to set the DMX address from 001 512 When you have finished setting the desired DMX address press the ENTER button DMX channel mode To select channel mode press the MENU button to show 3ch or 7ch on the display Now press the ENTER button and use the UP and DOWN buttons to select between the 3 or 7 channel modes To confirm your choice press the ENTER button Performer 36 RGB Operations Colour change mode To select the colour change mode press the MENU button to show CC00 on the display Now press the ENTER button and use the UP and DOWN buttons to adjust the speed of the colour change To confirm your choice press the ENTER button Colour fade mode To select the colour fade mode press the MENU button to show CP00 on the display Now press the ENTER button and use the UP and DOWN buttons to
3. adjust the speed of the colour fade To confirm your choice press the ENTER button Please note that in this mode the unit will run through both static colour fade and colour fade in out modes To access the modes individually please set the unit into DMX mode and see the DMX chart overleaf Auto built in programmes mode To select the Auto Built in programme mode press the MENU button to show dE00 on the display Now press the ENTER button and use the UP and DOWN buttons to adjust the speed To confirm your choice press the ENTER button Please note that in this mode the unit will run through all of the colour change and colour fade modes To access the modes individually please set the unit into DMX mode and see the DMX chart overleaf Sound active mode To select the Sound active mode press the MENU button to show bEbE on the display Now press the ENTER and the unit will respond to the beat of the music Static colour mode Red To adjust the brightness of the red LEDs press the MENU button to show R255 on the display Now press use the UP and DOWN buttons to adjust the brightness from 000 255 To confirm your choice press the ENTER button Note 000 off 255 full on Green To adjust the brightness of the green LEDs press the MENU button to show G255 on the display Now press use the UP and DOWN buttons to adjust
4. of purchase OPERATING DETERMINATIONS If this eguipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Performer 36 RGB Technical Specifications You should find inside the LEDJ carton the following items 1 36 RGB unit 2 Instruction manual Performer 36 RGB Featuring 36 x 3W LEDs R 12 G 12 B 12 the Alu Performer Par punches out astonishing spots of colour that can serve as a stunning show for various applications from uplighting a large venue and lighting a stage for live performances 06 e CEX DMX IN DMX OUT e 36 x 3W LEDs R 12 G 12 B 12 e Beam angle 25 e DMX channels 3 or 7 selectable e Static colour colour change fade auto sound active and master slave modes e Bracket allows for multiple rigging or floor standing applications e 4 push button menu with LED display e 3 Pin XLR in out sockets e Captive power connection e Fan cooled ES e Power consumption 118W Power supply 100 240V 50 60Hz Dimensions 255 x 297 x 325mm e Weight 2 6kg 9000 MENU DOWN ENTER PERFORMER 36 RGB www prolight co uk Setup Operating Instructions The
5. CKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Li i Pin 2 Negative Li i 3Hot 3Hot Pin 3 Postive Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 3 pin CABL89 5 pin will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion WEEE notice Correct Disposal of this Product Waste Electrical 8 Electronic Equipment Applicable in the European Union and other European countries gt with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o
6. X data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in the DMX line When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Performer 36 RGB DMX Setup DATA Cable DMX cable reguirements for DMX operation e The Performer Series can be controlled via DMX 512 protocol The DMX address can be set on the back ofthe fixture Your fixture and your DMX controller reguire a standard 3 pin XLR connector for data input output figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Figure 1 Please guote CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split Notice e Be sure to follow figures 2 8 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 2 Y lt DMX 512 in 3 pin XLR Loa II E O Rs 3 pin XLR DMX fe ese eee a a eee ee see ee esas i A XLR MALE SO
7. d do not modify the equipment e Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors Do not expose to flammable sources liguids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 100 240V e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date
8. f wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal CE td Create the right effect www prolight co uk
9. the brightness from 000 255 To confirm your choice press the ENTER button Note 000 off 255 full on Blue To adjust the brightness of the blue LEDs press the MENU button to show B255 on the display Now press use the UP and DOWN buttons to adjust the brightness from 000 255 To confirm your choice press the ENTER button Note 000 off 255 full on Performer 36 RGB Operations Master slave mode To set the unit as a master simply select any of the above modes and set the slave units into DMX mode address 001 The slave units will now follow in sequence with the master unit DMX chart 3 Channel CIAT SSF eas 3 7 Channel i 2 Strobe Slow to fast Manual DMX Colour change Colour fade Ts CCE E e CC Ce 7 oss KT DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DM
Download Pdf Manuals
Related Search
Related Contents
Oregon Scientific Projector Alarm Clock OM and MG Straight Blades with Cable Activated Sony KDL-40W3000 User's Manual 取扱説明書 (577.47 KB/PDF) Développement durable Énergie, climat Prévention Kenmore . 106 User's Manual 20KL燃料給油車 Kenwood Electronics DDX4021BT car media receiver Cardinal-Health-VELA-Ventilator-Service-Manual Manual - INCON Copyright © All rights reserved.