Home

User's Manual Control system « MecaTecCenter » Content:

image

Contents

1. For cleaning use only a light humid cloth Page 18 Mecalec DRIVE MADE IN GERMAN 7 Technical Informations 800mA delay action 5 x 20 mm IEC 60127 2 250V me ee Air 20 up to 90 No condensation allowed Protection category IP54 Protection class Dimensions B x H x T 240 x 465 x 100 mm CE Motor voltage 24V max 9 Max allowed output power 200VA All the outputs must be separated from the mains supply circuit that is by contact very dangerous Page 19 alec ge M Le Ce IN GERMANY Interface USB card GSM in development Top priority for your security and your relaxation We have developed the control system so that the client has the advantage to use it daily quite simply with one pressure on a button or key switch For more security and efficiency the authorized technician can obtain all the saved data ofthe memory with the modern IT accessories He can read them on the display Option directly at the client or on his own connected laptop Due to the card GSM Option it is possible for the technician to have access from afar to the programming and control data From anywhere he can access the data For this purpose he only needs to know the password and has to possess a SIM card With this feature you can quickly find out the error and easily understand the reason of the malfunction Two ways for controlling and regulating the control system 1 Connection cable USB b
2. from the jumper done in the external interruptor box and connect it on the clamp No 11 You attach both other wires to the clamps No 6 and 7 ai JENI JTE ji eS j e External interruptor Keyswitch Warning Shut off electricity at the source before doing electrical work Page 11 Mecalec DRIVE MADE IN GERMANY 3 2 4 Cable of the motor in the middle Depending on the model you have a 5 or 7 core cable between the control system and the motor for the cover conform to the provisions of the country a 5 core cable The blue wire No 2 and the black wire No 1 24 VDC must be connected on the black wire termination block the black wire on the left the blue wire on the right Three are colored numbered from 3 to 5 and they must be connected to the respective clamps according to the same numbers Nr 3 Red wire Encoder Nr 4 green wire Encoder Nr 5 Grey wire Signal Encoder Bue wie cure 7 En Page 12 Mecalec amp amp DRIVE MADE IN GERMANY b 7 core cable The blue wire No 2 and the black wire No 1 24 VDC must be connected on the black wire termination block the black wire on the left the blue wire on the right Five black wires numbered from1 to 5 must be connected to the respective clamps according to the same numbers Nr 1 Brake 24 V Nr 2 Brake 24 V Nr 3 Wire Encoder 12 V Nr 4 Wire Encoder 12 V Nr
3. If required you can adjust the position of the cover by rolling up and out before you save it and confirm the final position closed To save the desired position and confirm it press button No 1 for a second The LED at button 1 is going out and the closed position has been saved The opened position will be automatically saved Note to guarantee a good working of the installation it is very important to bring the cover in the desired open position see point 2 roll the pool open before you go to point 4 roll the pool closed Button 1 Button 3 Page 16 alec ae M Le ao IN GERMANY Now the control system is able to open and close the cover automatically We recommend you to do a 5 Operating The external main interruptor that is not furnished with the control system box must be conformed to the requirements of the country and be equipped with either push buttons or switch key 5 1 Main external switch three buttons with inching function The cover can be activated using the push buttons with inching function Each one corresponds to a position open closed stop A short pressure on the scheduled button and the cover is moving in the programmed position In case of danger you can press the stop button and the cover is stopping immediately You must have the pool in sight for security reasons by switching off and out 5 2 Main external switch switch key function The switch key is connected pa
4. 5 Signal Encoder Blue wire without No Black wire without No 3 2 5 Power cable of the control system box right 3 core cable as power cable Black wire Blue wire Grounding wire 4 Commissioning 4 1 Switching on A Inspect all the cables the security system inclusively the cable of the motor and the condition of the cover before you switch on the control box No person is allowed in the swimming pool during operating of the control system box Test the Fl Error button After you switch on the red power button on the lower extern enclosure wall at first the green LED control lamp No 7 right and under the USB interface No 8 signalize that the mother board is under tension and then the three red control lamps on the left by the programming buttons are flashing for a short time in succession upward About ten seconds later the information feady appears on the display The control system box is ready for the commissioning Page 13 Mecalec DRIVE MADE IN GERMANY 4 2 Programming You should regulate the data with the display option Without the display you have to use the LED control lamps that are on the mother board left from the programming buttons Every step will be confirmed with flashing or glowing 4 2 1 Choose your language of course only if you use the display 1 Switch off the red power button on the lower extern enclosure wall 2 Keep the button No 2 pressed and swi
5. indications Otherwise it could cause personal or product related damages These Safety instructions are valid only in the Federal Republic of Germany Deployment in other countries has to follow the relevant national laws Besides the advices in these directions of use the general safety and accident prescriptions have to be considered If these indications should not be sufficient contact with the manufacturer can be established anytime through the stated address Follow imperatively the rules A B and C listed below A Referring to the electric installation assembly change and verification e Please check the package and claim any eventual damages immediately to the forwarding agent e Repairs should be accomplished by an expert under deployment of the original spare parts Otherwise there could emerge further damage and control system breakdowns which the MecaTec Drive company can no longer warrant e The guarantee assessed check by a MecaTec Drive expert has to be done in due time An accurate check will point out any possible damage and or abrasion e To avoid any injuries the equipment should be properly installed on the wall e Do not expose any tools to water and others liquids e The control system should be fixed at a dry high situated minimum 1 5 meter above the floor or lockable location inaccessible for children e Take precautions to touch the control system only with dry hands and avoid any contact with the
6. motherboard as long as this is under voltage e Incase of modification of any control system parts or use of external spare parts without prior agreement with the MecaTec Drive company this one will assume no liability e For the control system operation a 12V or 24V safety extra low voltage line is necessary e As safety precaution a connection has to be built between the earth conductor and an adequate protective earth before any other connection e For both conductive material choice and installation of the energy supply junctions the terms of high voltage system construct with nominal voltage up to 1000V IEC 60364 rather DIN VDE 0100 are to be followed e The equipment has to be disengageable through an attributed separator installed externally This separator has to be located near the equipment It has to be consistent with IEC 60947 1 and IEC 60947 3 It has to disconnect all conductors lt has not to be installed inside a feeder Page 5 Mecalec DRIVE MADE IN GERMANY lt has to be accessible to the user e lfariskless operating is expected not to be guaranteed anymore the equipment has to be set off and secured against unintended operating e Ariskless operating is not guaranteed anymore if The equipment shows visible damage The equipment doesn t work After storage under damaging conditions After difficult transport When linked there has to be paid attention to a spatial separation of circuits that bear danger of cont
7. Mecalec e Users Manual Control system_ MecaTecCenter Please read this manual carefully and keep it for future use Content 0 Introduction 1 Warranty 2 Safety Instructions 3 Installation und Connections 3 1 Installation 3 2 Connections Commissioning Operating Repairs and Maintenance N O1 A Technical Specifications mecaTec drive GmbH amp Co KG ReichardstraBe 16 D 31789 Hameln Tel 051 51 26 224 Fax 051 51 27 879 E Mail info binder antriebstechnik de Page 1 Mecalec DRIVE MADE IN GERMANY 0 Introduction The control system MecaTecCenter an electric and electronic equipment suitable for motor driven rolling in and out operations of pool covers Motor Power up to 250 Nm Components and their function figure1 Box solid enclosure with bolted transparent covering In the lower enclosure part lays the fixed control system On the lower external enclosure wall the main power button of the control system and emergency switch No 1 and three cable inlets for connections No 2 motor cable Programming system and memory Transformer for 24 VDC No 4 Cut out of 10A No 5 Electronic motherboard No 6 USB interface No 8 with its own blinking LED control lamp No 7 The USB interface No 8 is not adapted to be connected with Mac or Linux computers Numbered wire termination block No 9 with attachment screws Template for the correct drilling of the attachment screws
8. act and low voltage circuits without any danger of contact A distance of 8 mm is recommended e Reassure before commissioning that the equipment shows no signs of damage In case of doubt consult a certified electrician or contact the below mentioned address B Referring to the control system usage e To assure electric shock protection the equipment has to be operating in closed condition e lf the equipment is brought immediately from a warm to a cold environment condensed moisture can appear Wait until a temperature adjustment has occurred Commissioning during humid condition signifies mortal danger e Do not forget that certain parts in electric and electronic equipments can run on electric voltage when being in use Unqualified handling and non observance of the warning notice can result in material and physical harm e Protect the line cord from heat water and sharp objects e Keep children and unauthorized persons away from the control system box e Make sure that the swimming pool as actual danger zone is not used during activation of the control system to close or to open the cover and that no person remains next to its edge Check imperatively that no object constricts the cover s running in and deployment e Before opening the equipment there can be bared energized parts Furthermore the junctions can under current Tasks on the opened equipment under voltage have only to be done by an expert to whom the existing danger
9. etween your laptop and the control system box for on site support Insert your cable in the USB plug The flashing LED control lamp shows successful connection 2 Card GSM for controlling from afar If the person responsible for maintenance can use a SIM card prior registered to the system he can access all saved data at anytime from anywhere Both ways offer the qualified staff the possibility to execute the same complete regulations on the control system box It would be better for the technician to attend a training course where he could get suitable software and a certificate Thus equipped he could use his computer for complete configuration and programming of the system The difference is only practicability in the distance Working with laptop and USB port cable 1 requires being on site Thanks to the remote maintenance you can work everywhere and only need your SIM Card number Page 20
10. h as contusions drowning or an electric shock as well as mortal accidents Please read all the security instructions and cautionary markings carefully MecaTec Drive will makes with pleasure repairs or exchanges under guaranty and is sorry for the inconveniences caused The control system MecaTecCenter and the periphery remote control GSM card power supply display come with a 2 years warranty starting with the delivery date The electronic mother board comes with a 5 years warranty Please consider that the warranty only becomes effective if all of the given instructions were followed respectively The 5 years warranty will only be effective when an inspection for the device and his components has been conducted after 36 months by a specialist of the MecaTec Drive Company Page 3 ares ge M Le Ce IN GERMANY Exclusion of liability The MecaTec Drive company is not reliable for any claims caused by use of the control system or caused by any installation maintain and first commissioning by an incompetent person or if the control system was misused for inappropriate purposes Moreover there is no possible commitment if a however qualified person installs the control system improperly Because of modifications by components of the control system box or because of the use of original spare parts without every previous consultation with the society MecaTec Drive this one won t assume any liability 2 Safety Instructions and Explana
11. in the wall screws and dowels Three programming buttons No 10 with corresponding LED control lamps No 11 also used as signal lamp in case of error report Battery for time and date specification No 12 Options Detachable monochrome display No 3 GSM card Remote control Page 2 ares ge M Le Ce IN GERMANY The control system MecaTecCenter represents an important innovation During developing of the new automatic control system MecaTecCenter we gave our attention at first to the security and a simplified control to guarantee an immaculate operating The electronic technology allows an accurate observance of the functioning and different parameters In fact lot of saved data can be read and modified not only locally but also through the remote control due to the USB connection and the GSM card Furthermore the control system can be used for all motors of different label with built in encoder 1 Warranty With the purchase of the control system MecaTecCenter you have opted for a high quality electronic control system for Pool cover motors Quality and Security are the bases for a reliable product Therefore please read this notice carefully Electric and electronic equipments must be installed only by qualified staff The person has to have read and comprehended all of the security indications Inappropriate installation constructional changes or non observance of the security instructions can cause serious injuries suc
12. rallel to the wires of the buttons and assumes the same functions A Warning Except France Closing the cover can happen only under operating conditions Opening the cover needs to snap the key For security reasons when closing the cover you need to maintain the key snapped all the time until it reaches the end position The middle position of the key between switch off and switch on will stop the movement of the cover Bv operating you can read following other data on the display Below on the left number of motor revolution Below on the right current consumption of the motor Date and time take away the plastic clip from the battery and it will be active right from the display on the mother board so you can regulate the date and the time in development These indications can be very helpful for locating the disturbance source Red emergency button power button on the control system box The red power button on the lower external enclosure wall serves as main switch interruptor For programming the language of the display it has to be switched off and on As emergency button you switch it to stop directly the movement of the cover Page 17 alec ae M 1e Ce IN GERMANY 6 Repairs and Maintenance Check regularly the condition of the control system box of the cables and of the motor If the system is breaking off and you notice abnormal noise or heat development please contact our service at the below mentioned address
13. red as follows 322 Make the wires free from rubber on 8 mm and connect the insulated ends to the scheduled clamp connections in the wire termination block following the connection diagram Look at the picture 100 mm Connect the grounding wire Grounding is necessary to assure the strength class To keep a safe separation you must put the main power cable 230 V AC into the scheduled screw The separation distance has to be about 10 mm 3 2 2 Connection diagramm External interruptor with buttons left Display Folia ha 6 0 0 0 6 60 s a A Ce O fe ll cr D wi External Interruptor Switch Key Page 9 alec ae M Le aon IN GERMANY Terminal connections 1 Brake 24 V Don t connect it with a motor with magnetic brake 2 Brake 24V Don t connect it with a motor with magnetic brake 3 Encoder 4 Encoder 5 Encoder Signal 6 Cover open 7 Cover closed 8 Cover stop Only for button stop 9 Reserve 10 Reserve 11 12 Reserve Change over switch with relay 13 Reserve Change over switch with relay 14 Reserve Change over switch with relay After effecting all the connections the screws have to be tightened Page 10 Mecalec DRIVE MADE IN GERMANY 3 2 3 Connection diagramm External interruptor keyswitch right For the key you have three wires you need to connect on the long numbered wire termination block you take the finest wire the cable O
14. s are familiar e Before commissioning please check if the equipment s operational voltage and the system voltage correspond e Fuse exchange and Reparation have to be done by authorized staff Please contact the below mentioned address e Before cleaning cut off the grid Use only simple cleanser with a humid cloth Never clean dripping wet C General Safety Notice for swimming pool use e The pool cover should be completely extended or removed from the water surface e In absence of an adult the swimming pool should be covered even if it is only about a short period e Children are to be advised of the dangers concerning the control system the pool and its cover Do never play next to the covered pool nor enter the pool cover Page 6 Mecalec E DRIVE MADE IN GERMANY 3 Installation und Connections 3 1 Installation A All the installation of the box and the commissioning are to be executed by qualified staff For the connection work the qualified staff must be well grounded in electronic system and electricity e Location Choose a closable roofed room with available electric equipment and without humidity lt has to be maximum 40 meters away from the swimming pool and should have direct sight of the pool e Between the control box and the external operating switch push buttons or key operated switch use a cable that should not be longer than 15 meters e Install the control box on the wall and not less than one me
15. tch on the red power button on the lower extern enclosure wall until the information Language or Sprache or Langue appears 3 Press several times button 3 until your language appears 4 Confirm your choice by pressing button No 2 for one second d d A a E EN 4 Confirm choice 3 Select language 4 2 2 Regulation of the initial and end positions A No person allowed in the swimming pool during operating of the control system box by cover s running in and deployment At the beginning open the cover and bring it in the initial position Initial position open cover roll the pool open Page 14 Mecalec si Page 15 O1 Mecalec S DRIVE MADE IN GERMANY Programming of the closed position Press three seconds on button 1 until the information Programm appears on the display The red LED control lamp by the button is flashing or burning Now activate the external main interrupt ir buttons or key switch and bring the cover in the begin position roll the pool open open position During this opening operation the red LED lamp button 2 is flashing all the time If required you can adjust the position of the cover by rolling up and out Now activate the external main interrupt ir buttons or key switch and bring the cover in the final position roll the pool closed closed position During this closing operation the red LED lamp button 3 is flashing all the time
16. ter above the floor e Turn the three cable inlets of the connection entrances to the floor Installation on the wall Fix it with the 4 screws on the wall The dimensions are 219 x 140 mm Use the template for the drilling of the holes drill bit dowel Nr 5 Bild 2 Attachments A The holes for the box attachments are located directly near the screw points of the cover and outside from the protected waterproofed zone Therefore the degree of protection against penetration of water won t be lowered Page 7 Mecalec DRIVE MADE IN GERMANY 3 2 Connections A Warning Shut off electricity at the source before performing electrical work The cable connection should be only accomplished by a qualified expert with the required knowledge Bild 3 Connection place 3 2 1 Main cables from outside The cables should be connected as follows Loosen the cable inlets at the lower side and introduce the three cables following the plan Standing in front of the box you put them in this order 1 On the left cable of the external operating switch push buttons or switch Key this box for external interruptor is not included by the control system MecaTecCenter 2 Inthe middle cable of the motor 3 On the right power cable of the box for controlling system with 230 V AC For this you must push down with a flat screwdriver the rubber insulated wires Page 8 Mecalec E DRIVE MADE IN GERMANY The leads must be prepa
17. tions Mecalec DRIVE MADE IN GERMANY Important Safety Instructions Use these instructions carefully and have a detailed look at the equipment before any installation operation or maintenance Symbols Please respect the explanations to the following listed warnings They are present in the whole document as well as on the equipment itself and point out potential risks and dangers or particular information that describe and simplify a proceeding Explanations to the used symbols The indication DANGER refers to a potential dangerous situation that can cause massive injuries or even death if not avoided The indication WARNING refers to a potential danger that can cause material damage or WARNING injuries if not avoided Page 4 Mecalec e Safety Regulations The Control System MecatecCenter is an accredited product lt was developed under the terms of the following norms e according DIN EN 60335 1 02 2007 Safety of electric equipment for domestic use and similar purposes Part 1 General claims e according DIN EN 55014 1 and DIN EN 55014 2 e CE certificated and certified e Has to quit the factory in safety related unobjectionable condition To guarantee this condition handling of the equipment transport bearing installation initiation operating system maintenance shutdown has to be done in respect of the safety regulation s content and the equipment s indicated model plates captions and safety

Download Pdf Manuals

image

Related Search

Related Contents

04 ISC 161 Manual Tecnico  Otterbox DEL1-STRK1-20-C4OTR mobile phone case  GE Profile J2B915 Dual Fuel (Electric and Gas) Kitchen Range  IP Wireless / Wired Camera WATERPROOF User Manual  フ〟不ー夕ー A4 Sーze `AgSーze  Hardware Reference  m4 manual - Inspire Fitness  EXSYS EX-1183HMVS  Pelco pelco C2915M-E User's Manual  