Home
Standalone Keypad Access Control User Manual
Contents
1. back of the User can be added continuously without exiting programming mode card user ID number auto generation To add a card user Method 4 In this method a User ID is allocated to a card number User can be added continuously without exiting programming mode Only one user ID can be allocated to the card number To delete a card user by card Note users can be deleted continuously without exiting programming mode To delete a card user by user ID This option can be used when a user has lost their card To delete a card user by card number This option can be used when the user want to make Note users can be deleted continuously without exiting the change but the card has lost programming mode To add a card and PIN user in card and PIN mode To Add a card and Pin user Add the card as for a card user The PIN is any four digits between 0000 amp 9999 with Press x to exit from the programming mode the exception of 1234 which is reserved Then allocate the card a PIN as follows To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves To add a card user in card mode To Add and Delete a card user The operating is the same as adding and deleting a card user in 3 2 To delete ALL use
2. either indoor or outdoor in harsh environments It is housed in a strong sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish The electronics are fully potted so the unit is waterproof and conforms to IP68 This unit supports up to 2000 users in either a Card 4 digit PIN or a Card PIN option The inbuilt card reader supports 125KHZ EM cards 13 56MHz Mifare cards The unit has many extra features including lock output current short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons 4 Features Waterproof conforms to IP68 Adjustable Door Output time Alarm time Door Open time Strong Zinc Alloy Electroplated anti vandal case Very low power consumption 30mA Full programming from the keypad Fast operating speed lt 20ms with 2000 users 2000 uses supports Card PIN Card PIN Lock output current short circuit protection Can be used as a stand alone keypad Easy to install and program Backlight keys Built in light dependent resistor LDR for anti tamper Wiegand 26 input for connection to external reader Built in buzzer Wiegand 26 output for connection to a controller Red Yellow and Green LEDS display the working status 5 Specificat
3. de buzzer operate To remove the alarm To reset the Door Open Too Long warning or ES a 12 The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input ALARM OPEN 12V GND NO Access Controller COM NC ii Connect Issue Record Door Site Location User Pin Code User Name Number Card Fob number Issue Date 0i 7 O 55
4. ions Adjustable Door Relay time Wiring Connections Electric Lock Exit Button External Alarm External reader 6 Installation Remove the back cover from the keypad using the supplied special screw driver Drill 2 holes on the wall for the Self tapping screws and hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 Self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover i J S ES ES ES IES E3 Ed SS g Gweu E ooo EA Y med awe 2Y DO gaed PoweU Relay normally on end Connect positive electric lock Relay Closed end connect negative electric lock Connect Special power supply diagram OPEN D_IN cU 3 12V Red E GND NO Bue com NC Connect 8 To Reset to Factory Default a Disconnect power from the unit b Press and hold key whilst powering the unit back up c On hearing two Di release key system is now back factory settings Please note only installer data is restored user data will not be affected 9 Anti Tamper Alarm The unit uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed from the cover then the tamper alarm will operate 10 Sound and Light indication 11 Detailed Programming Guide 11 1 User Settings To enter the programming mode 999999 is the default fac
5. rs Note that this is a dangerous option so use with care To unlock the door For a PIN user Enter the then press 5 For a card and PIN user 11 2 Door Settings Relay Output Delay Time To set door relay strike time 0 99 is to set the door relay time 0 99 seconds Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 20 seconds the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To enable door open detection Alarm output time To set the alarm output time 0 3 minutes Factory default is 1 minute Keypad Lockout amp Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm factory Factory default setting default Keypad Lockout Alarm and insi
6. tory master code To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code The master code can be 6 to 8 digits long Setting the working mode Set valid card only users Entry is by card only Set valid card and PIN users Entry is by card and PIN together Set valid card or PIN users Entry is by either card or PIN default To add a user in either card or PIN mode i e in the mode Default setting To add a Pin user The ID number is any number between 1 amp 2000 The PIN is any four digits between 0000 amp 9999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 UserIDno1 PIN UserlDno2 PIN To delete a PIN user Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user This step must be done out of programming mode To add a card user Method 1 This is the fastest way to enter cards user ID number Cards can be added continuously without exiting programming auto generation mode To add a card user Method 2 This is the alternative way to enter cards using User ID User can be added continuously without exiting programming mode Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card To add a card user Method 3 Card number is the last 8 digits printed on the
7. www quantek co uk Standalone Keypad Access Control User Manual Prox Ltd Quantelk Please read the manual carefully before using this unit 1 Packing List Keypad Rubber plug 4 1 1 2 2 2 Quick Reference Programming Guide 3 Description To enter the programming mode To exit from the programming mode Note that to undertake the following programming the master user must be logged in 999999 is the default factory master code To change the master code To add a PIN user To add a card user To delete a PIN or a card user To unlock the door for a PIN user To unlock the door for a card user The master code can be 6 to 8 digits The ID number is any number between 1 amp 2000 The PIN is any four digits between 0000 amp 9999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode Cards can be added continuously without exiting programming mode 2 Read Card for a card user Users can be deleted continuously without exiting programming mode P6mmx30 mm used for fixing Self tapping screws E P4mmx28 mm used for fixing Please ensure that all the above contenis are correct If any are missing please notify us for a PIN user or Enter the then press Present the card T 01246 417113 The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader It is suitable for mounting