1. Service manual and spare parts list Drying cabinet with 8 kg cloth capacity 549225 Thank you for choosing our drying cabinet We hope that it will be of great use for you 2011 2 Contents Specification Dimensions Technical information Main control board Service menu Parameter list Explanation of parameters Error codes Spare parts list Cabinet Top Electrical drawing A 11 2011 Specification Dimensions 200 1870 1200 1453 A Electrical connection B Exhaust 2011 Technical information Loading capacity kg lb up to 8 17 6 Drying capacity g min oz min 91 3 2 Hanging length m ft 16 52 5 Drying time min 35 Evacuated air max m2 h ft8 h 340 12007 Exhaust mm in 125 4 92 Heating effect kW 6 0 Total effect kW 6 3 Energy consumption kWh kg KWh Ib 0 55 0 48 Part No 131025 the textiles are dry Drying of 6 kg 13 2 Ib cotton dry weight washed and high spinned to 53 residual moisture The cabinet works another 15 minutes with cool down after Main control board This drying cabinet can be customized by adjusting the main control board s parameters The following pages describe how to adjust the parameters Service menu Activate the service menu To enter
2. TIME 000000 h TEST LOOP ON OFF OFF CLEAR E CODE YES 2011 Explanation of parameters LANGUAGE The drying cabinet is delivered with English display text as standard Choose between Swedish English French German and Spanish MODEL Choice of product model Shall always be in position TS 62 RESET Resets all parameters to initial factory position DEGREE UNIT Degrees can be displayed in Celsius or Fahrenheit MIN TEMP Setting of minimum temperature level in manual mode means that the heating is off The highest possible degree to be chosen is affected by parameter MED TEMP MED TEMP Setting of medium temperature level in manual mode Choice of temperature level is affected by the value of both MIN and MAX TEMP MAX TEMP Setting of maximum temperature level in manual mode Lowest temperature level to choose is affected by the value of param eter MED TEMP DEF TEMP Sets the default temperature when the user enters manual mode SHOW DEGREES Manual mode shows the chosen temperature in degrees This function can be turned off so that only the symbol on the ther mometer is shown MAX TIME Setting of time in manual mode Maximum 9h 59 minutes DEF TIME This parameter controls the time which is default when the user enters manual mode DELAY START This parameter activates delayed start If the parameter is set to ON the user is given the choice to delay the programme st
3. art with up to 9h 59min AUTOPROG It is possible to activate up to nine automatic programmes De fault from factory two pre programmed choices Programme 1 WARDROBE DRY Programme 2 IRON DRY Each programme has two parameters TEMP and HU STOP When AUTOPROG is set in mode OFF the automatic pro grammes is inactivated If the user choose automatic mode the display shows INACTIVATED PR TEMP Every automatic programme can be adjusted by choosing temperatures MIN MED MAX The temperature values are the same as parameters MIN TEMP MED TEMP and MAX TEMP PR HU STOP HU STOP affects the automatic drying function Can be chan ged if needed If the value of HU STOP is decreased the drying time is prolonged for the automatic programme HYST TEMP It controls the hysteresis The drying cabinet is preset to 10 C When the working temperature is attained and the heating ele ments are turned off it will be a delay When the temperature hits 10 C the heating starts again Shorter hysteresis increase the energy consumption COOL DOWN After the heating phase the cabinet has a period of cool down to recondition the laundry and lower the temperature within the cabinet The time is set to 15 minutes PLEASE NOTE Without a sufficient cool down period the inner plates of the cabinet will be very hot SHOW TEMP HU This parameter is for error searching If set in mode ON the cabinet will show current tem
4. ed to a booking system Choose position depending on which type of signal the booking system is sending PLS stands for pulse and means that the cabinet is booked per drying period One pulse gives one drying period N O is chosen when the signal is either on or off The current programme will always run until finished even if the signal is broken during the programme WORK TIME The parameter shows the total amount of hours the cabinet has been on It is also memorized if the electricity to the control board is broken TEST LOOP Start the test programme by changing the parameter to ON The programme can be used to control the components in the cabinet Parts are activated as follows To go to the next step press arrow button The programme goes automatically to the next level after 30 seconds Fans connected to FAN1 External fan connected to FAN2 optional Heating on All segments on LCD display are lit and the background light flashes The temperature sensor shows current temperature 6 The humidity sensor shows current air humidity PONS CLEAR E CODE Is used to erase an e code in the display after the problem has been solved Press the right arrow button 2011 Error codes Disp Reason Activity T1 Control board gets no signal from the tempera ture sensor Control that the sensor is connected correctly on the main control board and that the cable from the sensor to the b
5. ensor 8 TS 61083 Condenser 9 0110150 2 Main control board 10 TS 61098 Service door upper 2011 10 Electrical drawing L1 L2 L3 3 400 50 60Hz Ki Ja R1 3 M1 FAN MOTOR M2 FAN MOTOR K1 RELAY HEAT K2 RELAY FAN K3 RELAY EXT FAN OPTION B1 MICRO SWITCH B2 MICRO SWITCH L1 LIGHT H1 HUMIDITY SENSOR NTC1 THERMISTOR R1 R3 HEATING ELEMENT T1 THERMOSTAT OPTION KF1 CONDENSATOR 1 KF2 CONDENSATOR 2 18 11 12 I A2 Kilo Al n Kia 2 120 1 KKT MAIN HEATER FANI FAN2 LAMP DOOR NTI E L 2 22 B 13 1 Hil FA L1 13 2 B2 X2 14 10528105 2 2011
6. oard is intact OH The control board s elec tronically overheat protec tion has been activated The error code is gener ated if the temperature is risen above 100 C twice within 30 minutes Control that the fan mo tors are working as they should Also control the temperature sensor and that the cable from the board is intact HU The control board gets no signal from the humidity sensor Control that the sensor is connected correctly on the main control board and that the cable from the sensor to the board is intact Spare parts list Cabinet DO Part No Description 1 TS 61084 Door left 2 TS 61085 Door right 3 TS 61086 Handle 4 TS 61099 Service door lower left 5 TS 61096 Service door lower right 6 TS 61081 Lamp Bulb 7 70107001 Door switch 8 TS 61089 Magnet list 9 0110151 2 Display control board 10 TS 61090 Cover glass 11 0110152 Keypad 12 011053 Sticker user manual 13 TS 61091 Hanging frame 14 TS 61093 Hanging level 4 arms 15 TS 61092 Hanging level 5 arms 16 TS 61094 Foot 17 TS 61097 Protection plate Detailed view A 2011 Top No Part No Description 1 TS 61080 Element 2000 W 2 E 150020 Fan motor 3 0110155 2 Temperature sensor 4 TS 61026 Over heat protection 120 C 5 504142 Relay LC1 D12P7 230 V 6 TS 61082 Disturbance filter 7 0110154 2 Humidity s
7. perature and air humidity by re spective sensors SHOW LOGO Turns on and off the logo on the top of the LCD display SOUND This parameter controls if the sound shall be on or off In mode ON you can hear a distinct beep noise every time the but tons are pushed or when a drying period is ended STANDBY In position ON the display background light is automatically turned off if no button is pushed for two minutes The display light is turned on when any button is pushed or if the doors are opened In position OFF the light is constantly off LIGHT TIME When the doors open the light inside the cabinet is turned on With the parameter LIGHT TIME you set how long the light will be on if the doors are left opened When the time is up the lamp is turned off automatically PAUSE TIME If the doors are opened during drying the drying programme is paused Are the doors left opened for a long time the pro gramme will stop The time is adjustable from 0 30 minutes will stop the programme as soon as the doors are opened PLEASE NOTE If the parameter is set to O minutes the cabinet 2011 COIN The cabinet can be connected to a booking system To acti vate the function set the parameter in position ON To start a programme a connection to the control board s COIN contact is needed SIGNAL TYPE This parameter is only visible if COIN is activated COIN is used when the cabinet is connect
8. the service menu press both left arrow buttons in about 5 seconds The LCD display shows the software version installed on the control board 9 lt Push the START button 5 times continuously to enter the rameter list Navigate in the service menu To browse in the parameter list use the two top buttons Change parameter values Depending on if the present parameter shows temperature time or ON OFF function the present value is either shown on the left or on the right side of the LCD display To change the value use the arrow buttons BE o DB Leave the service menu Push the start button 2011 Parameter list Parameter Alternative Factory position LANGUAGE SWE ENG FRE GER SPA ENG MODEL TS 62 T 196 TS 92 DC 8 TS 62 RESET YES DEGREE UNIT C F C MIN TEMP 25 gt MED 5 40 MED TEMP MIN 5 gt MAX 5 60 MAX TEMP MED 5 90 80 DEF TEMP MIN MED MAX MAX SHOW DEGREES ON OFF ON MAX TIME 1 00 09 59 03 00 DEF TIME 0 00 MAX TID 00 40 DELAY START ON OFF OFF AUTOPROG OFF 1 9 2 PR1 TEMP MIN MED MAX MAX PR1 HU STOP 0 995 65 PR2 TEMP MIN MED MAX MAX PR2 HU STOP 0 995 490 HYST TEMP 0 20 10 COOL DOWN 0 00 0 20 00 15 SHOW TEMP HU ON OFF OFF SHOW LOGO ON OFF ON SOUND ON OFF ON STANDBY ON OFF ON LIGHT TIME 0 00 0 30 00 10 PAUSE TIME 0 00 0 30 00 10 COIN ON OFF OFF SIGNAL TYPE PLS N 0 N 0 WORK