Home

Operating Instructions

image

Contents

1. 12 Steering target Steering indicator Calculated horizontal distance between transmitter and receiver Calculated transmitter depth Target Steering Screen 12 DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED D Il Appendix A System Specifications The power reguirements and environmental reguirements for the DigiTrak Multi Function Cable Box and remote displays are listed below Power Reguirements Device Model Number Operational Voltage Operational Current DigiTrak Multi Function Cable Box 12 28 V DigiTrak Remote MFD Display MFD 12 28 V DigiTrak Remote F Series Display FSD 12 28 V DigiTrak Eclipse and F Series Cable Transmitter E DigiTrak Eclipse Steering Tool SST 9 28 V Environmental Requirements Relative System Working Device Humidity Operating Temperature Altitude DigiTrak Multi Function Cable Box 4 to 140 F 20 to 60 C DigiTrak MFD Remote Display MFD lt 90 4 to 140 F 20 to 60 C DigiTrak F Series Remote Display FSD lt 90 4 to 140 F 20 to 60 C Up to 6561 ft 2000 m DigiTrak Eclipse and F Series lt 100 4 to 180 F 20 to 82 C Transmitter ECP FC DigiTrak Eclipse Steering Tool SST lt 100 4 to 180 F 20 to 82 C DigiTrak MFCB Operator s Manual 13 I gt lt l DIGITAL CONTROL INCORPORATED Appendix B Transmitter Wire Repair or Replacement The cable lead and other end cap components in the c
2. head to confirm it is operating properly and providing accurate drill head location and heading information During drilling the depth will not be accurate unless e The receiver has been properly calibrated and the calibration has been checked for accuracy so the receiver shows the correct depth e The transmitter has been located correctly and accurately and the receiver is directly above the transmitter in the drill head underground or at the front locate point e The receiver is placed on the ground or held at the correct height above ground distance which has been set correctly Always test calibration after you have stopped drilling for any length of time Interference Interference can cause inaccuracies in the measurement of depth and loss of the transmitter s pitch roll or heading Always perform a background noise check prior to drilling e Sources of interference include but are not limited to traffic signal loops invisible dog fences cable TV power lines fiber trace lines metal structures cathodic protection telephone lines cell phones transmission towers conductive earth salt salt water rebar and radio frequencies 2 DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED I gt Il Interference at the remote display may also occur from other sources operating nearby on the same freguency such as car rental agencies using their remote check in modules or other directional drilling locating e
3. are not met Always ensure the transmitter is installed properly in the housing during use Directional drilling operators MUST at all times e Understand the safe and proper operation of drilling and locating equipment including the use of ground mats and proper grounding procedures e Ensure that all underground utilities have been located exposed and accurately marked prior to drilling e Wear protective safety clothing such as dielectric boots gloves hard hats high visibility vests and safety glasses Locate and track the transmitter in the drill head accurately and correctly during drilling e Maintain a minimum distance of 8 in 20 cm from the front of the receiver to the user s torso to ensure compliance with FCC requirements Comply with federal state and local governmental regulations Such as OSHA e Follow all other safety procedures DigiTrak MFCB Operator s Manual 1 I gt CI DIGITAL CONTROL INCORPORATED DigiTrak locating systems cannot be used to locate utilities Continued exposure of the transmitter to heat due to frictional heating of the drill head can cause inaccurate information to be displayed and may permanently damage the transmitter Remove the batteries from all system components during shipping and prolonged storage damage caused by leakage may occur Equipment and Battery Disposal other household waste Instead it is your responsibility to dispose of such equipment at a designat
4. i oi i oi KAKA o i s 3 Caring for Your Iransmillar zu ase ase ait s ase ae eier 3 Intro dU CHOI k sal di i ansedayaneni n ka eya nayan Su anadenia E ku Su HW AE SR HE HI n HDH HE HA VA HE EW HE HAH EWR 4 MEGB Connections ana 5 Powering the MFCB u 000 kkkakekakk kak aa k karak k k kk a ka wak Kani waa kaka Ku WA KA WI WA WEKA KE 6 Connecting to the Remote Displaj sssseeeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeees 7 Connecting to the Cable Transmitter ssseeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeees 8 Installing Transmitter in Housing J kk kk kk kak kk kk kk kk KK KAKA KAKA AA 9 Cable M de 0 kane siza kaka kade kaye k va ka ie k aa kaya kk ae k uwa k za ku kulak ewa k wak a kek ala kawe k s va a ku 10 Cable Mode Display EEE Fo sesoto si i i i i i i a i KK KK KK 10 Roll Olsen 11 Target SISS TING iii ii i i i ii Ki i K K i i i i i i n na r ha 12 Appendix A System Specifications uu nnn000000nnnn nenn nnnnnnnnnnnnnnn nenn 13 Power Requirements 44444444004n000nnnnnnnnn nn non kaka kk kk kK KK Ka K k kK KK KA KA KK A KK KK KK KA A 13 Environmental Requirement cccccccccsseeesseeeeeeeeeceeeeeeseeeeeeeeeeeeeeeeaaaees 13 Appendix B Transmitter Wire Repair or Replacemen t 14 Limited Warranty DigiTrak MFCB Operator s Manual v I gt CI DIGITAL CONTROL INCORPORATED vi Di
5. pull down menu to download view or print the documents DigiTrak MFCB Operator s Manual Contact Us DIGITAL CONTROL INCORPORATED I gt Il United States DCI Headquarters 19625 62nd Ave S Suite B103 Kent Washington 98032 USA 1 425 251 0559 1 800 288 3610 1 425 251 0702 fax dci digital control com Australia 2 9 Frinton Street Southport QLD 4215 61 7 5531 4283 61 7 5531 2617 fax dci australia digital control com China 368 Xingle Road Huacao Town Minhang District Shanghai 201107 P R C 86 21 6432 5186 86 21 6432 5187 fax dci china digital control com Europe Brueckenstra e 2 97828 Marktheidenfeld Germany 49 9391 810 6100 49 9391 810 6109 fax dci europe digital control com India DTJ 1023 10th Floor DLF Tower A DA District Center Jasola New Delhi 110044 91 11 4507 0444 91 11 4507 0440 fax dci india digital control com Russia Molodogvardeyskaya Street 4 Building 1 Office 5 Moscow Russia 121467 7 499 281 8177 7 499 281 8166 fax dci russia digital control com DigiTrak MFCB Operator s Manual IP CI DIGITAL CONTROL INCORPORATED Dear Customer Thank you for choosing a DigiTrak locating system We are extremely proud of the equipment we have been designing and building in Washington State since 1990 We believe in providing a unique high quality product and standing behind it with superior customer service and training Please
6. take the time to read this entire manual especially the section on safety Also please fill in the product registration card provided with this equipment and either mail it to DCI headquarters fax it to us at 253 395 2800 or complete and submit the form online at our website www digitrak com We will put you on the Digital Control mailing list and send you product upgrade information and our FasTrak newsletter Feel free to contact us if you have any problems or questions Our Customer Service department is available 24 hours a day 7 days a week International contact information is available on our website As the horizontal directional drilling industry grows we re keeping our eye on the future to develop equipment that will make your job faster and easier Visit us online any time to see what were up to We welcome your questions comments and ideas Digital Control Incorporated Kent Washington 2013 See our DigiTrak Training Videos on YouTube at www youtube com dcikent DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED gt Il Table of Contents Safety Precautions and Warnings nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 1 General wwR2 __ mm i r i i i mm 1 Equipment and Battery Disposal kk kk kk aaa aaa 2 Pre Drilling Testing i haa i kawa k y n yd di k j 2 IM LSE nlne asis aisiais i i i i i ii Caring for Your Cable BE sis soki
7. Manual Warranty 1 of 2 I gt CI DIGITAL CONTROL INCORPORATED LIMITATION OF REMEDIES AND LIABILITY In no event shall DCI or anyone else involved in the creation production or delivery of the DCI Product be liable for any damages arising out of the use or inability to use the DCI Product including but not limited to indirect special incidental or consequential damages or for any cover loss of information profit revenue or use based upon any claim by User for breach of warranty breach of contract negligence strict liability or any other legal theory even if DCI has been advised of the possibility of such damages In no event shall DCI s liability exceed the amount User has paid for the DCI Product To the extent that any applicable law does not allow the exclusion or limitation of incidental consequential or similar damages the foregoing limitations regarding such damages shall not apply This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state This Limited Warranty shall be governed by the laws of the State of Washington WARRANTY CLAIM PROCEDURES If you are having problems with your DCI Product you must first contact the Authorized DCI Dealer where it was purchased If you are unable to resolve the problem through your Authorized DCI Dealer contact DCI s Customer Service Department in Kent Washington USA at the above telephone number between 6 00 a m and 6 00
8. ONTROL INCORPORATED D Il MFCB Connections One side of the cable box has two power ports Although labeled Power and Remote Display they are identical and can be used interchangeably The other side of the cable box has a power post for connecting the transmitter wire the serial port is only used with the SST steering tool system Power post Magnetic base Power ports Serial port Multi Function Cable Box MFCB Although the DC power cable used to power a freestanding multi function display through the power port on the drill rig can power the cable box DCI recommends connecting the cable box directly to an independent automotive battery or DC power source other than that on the drill rig to avoid voltage disruptions and current draw variations that may interrupt power to the transmitter Power cable to independent DC power source Transmitter wire post Serial port to SST laptop To freestanding remote display lt To panel mounted remote display MFCB Connections DigiTrak MFCB Operator s Manual 5 I gt lt l DIGITAL CONTROL INCORPORATED For a freestanding remote display use the power cable with the same round four hole connector at both ends shown in the preceding images at left For a pane l mounted remote display use the cable with the rectangular orange four hole connector shown at right Both cables are included with the MFCB Powering the MFCB
9. The power ports on the cable box and freestanding remote display FSD are keyed for proper alignment To connect the power cable to the cable box align the key marks in the connector with the key slots in the power port then push in and rotate the cable connector clockwise until it locks into place with a snapping sound Connect the other end of the power cable to the DC power source When using the cable with the bare wires at one end recommended connect the white wire to the positive terminal and the black wire to the negative terminal Otherwise plug the DC cable connector directly into the drill rig s DC power port For the best results power the cable box directly from a standard 12 28 VDC battery or power source not the drill rig s battery For bores shorter than 1000 ft 305 m one 12 volt battery will suffice If the bore length exceeds 1000 ft use an additional battery in series as shown in the following diagram 12 28 VDC Connect batteries in the order shown 1 2 3 4 Disconnect 12V Battery 12V Battery batteries in the opposite order Wiring Batteries In Series 6 DigiTrak MFCB Operator s Manual DIGITAL CONTROL NCORPORATED gt Il The following diagram shows how the cable system components are connected when wired directly to a battery A ground wire must be installed between the negative terminal of a free standing battery and a ground point on the drill rig The ground point can be the negative term
10. able transmitter must be replaced when the wire shows wear twists or abrasions This involves removing the transmitter end cap to access the cable lead connection to the transmitter base The Replaceable Wire Kit DCKIT includes enough parts to replace the cable lead two times You will also need a standard screw driver The DCKIT contains e Two cable leads e Four Torx screws e Four lock washers end cap e Four 2 021 O rings Threaded hole for e Two screw insulators extraction insertion i tool two e Two 2 106 O rings Torx or e Two brass set screws buttonhead cap Three white nylon set screws screws two Transmitter gt body Transmitter e One T15 Torx wrench e One each ea s and Allen wrenches Wire End of Transmitter One tube of Noalox anti oxidant compound To disassemble and reassemble the transmitter end cap 2 gt Using the 5 s4 Allen wrench or the T15 Torx wrench depending on the screw type installed remove the two Torx or buttonhead cap screws and lock washers Pull the end cap from the transmitter base Identify the deepest set screw depression in the base Using the Allen wrench or a standard screw driver remove the white nylon set screw There will be a brass set screw behind the nylon screw that holds the cable in place Note Do not tamper with the brass set screw and O ring located on the opposite side of the base in the shallow depression U
11. d with the cable transmitter for proper installation and removal It is also critical for the slots in the drill housing to meet minimum length width and positioning requirements DCI s transmitters work best in housings with slots that are equally spaced around the circumference of the housing for optimal signal emission Each slot must be at least s in 1 6 mm wide For accuracy slot measurements must be taken from the inside of the housing For the FC and ECP cable transmitters 19 in 48 26 cm long the slots must be at least 9 in 22 9 cm long and begin at least 2 5 in 6 4 cm from the front end of the transmitter a SM Wire end Slot position Front end ji 4 li H 4 Slot length 2 5 in 9 in 22 9 cm 6 4 cm FC ECP Transmitter Housing Slot Reguiremenis The SST cable transmitter 24 in 60 96 cm long requires a non magnetic housing The slots in the housing must be at least 9 in 22 9 cm long and begin at least 8 5 in 21 6 cm from the front end of the transmitter Wire end Slot position Front end Slot length 8 5 in 9 in 22 9 cm 21 6 cm SST Transmitter Housing Slot Requirements To install an ECP or FC transmitter into its housing screw the threaded end of the extraction insertion tool into one of the two threaded holes 1 4 20 thread in the wire end of the cable transmitter Gently push the front end of the transmitter into the housing using the extraction insertion tool u
12. e cap 14 Install two new lock washers and Torx screws and tighten the screws in place using the T15 Torx wrench Note Use care when threading the Torx screws into the base to avoid cross MN threading DigiTrak MFCB Operator s Manual 15 I gt CI DIGITAL CONTROL INCORPORATED 16 DigiTrak MFCB Operator s Manual S DIGITAL 19625 62nd Ave S Suite B103 Kent Washington 98032 USA CONTROL 425 251 0559 800 288 3610 INCORPORATED dei digital control com www DigiTrak com Limited Warranty Digital Control Incorporated DCI warrants that when shipped from DCI each DCI Product will conform to DCI s current published specifications in existence at the time of shipment and will be free for the warranty period Warranty Period described below from defects in materials and workmanship The limited warranty described herein Limited Warranty is not transferable shall extend only to the first end user User purchasing the DCI Product from either DCI or a dealer expressly authorized by DCI to sell DCI Products Authorized DCI Dealer and is subject to the following terms conditions and limitations 1 A Warranty Period of twelve 12 months shall apply to the following new DCI Products receivers locators remote displays battery chargers and rechargeable batteries and DataLog modules and interfaces A Warranty Period of ninety 90 days shall apply to all other new DCI Products includin
13. ed collection point for the recycling of batteries or electrical and electronic equipment If the equipment contains a banned substance the label will show the pollutant Cd Cadmium Hg Mercury Pb Lead near this symbol Before recycling ensure batteries are discharged or the terminals are covered with adhesive tape to prevent shorting The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the equipment x This symbol on eguipment indicates that the eguipment must not be disposed of with your The battery charger provided with your DigiTrak locating system is designed with adeguate safeguards to protect you from shock and other hazards when used as specified within this document If you use the battery charger in a manner not specified by this document the protection provided may be impaired Do not attempt to disassemble the battery charger it contains no user serviceable parts The battery charger shall not be installed into caravans recreational vehicles or similar vehicles Pre Drilling Testing Before each drilling run test your DigiTrak locating system with the transmitter inside the drill
14. ffset Menu X Exit Exits the roll offset menu without saving changes Go Activates roll offset with the last set value Set Programs the displayed value as the roll offset Use the remote display s direction buttons to highlight the desired option and press the Execute button the curved arrow to select it Once the roll offset is programmed the screen looks like this Drill head s 12 o clock position 2314 9 ih Ta al 0 3A 14 2V lt lt 15 0V offset value A 75F Transmitter s roll Cable Mode Screen with Roll Offset DigiTrak MFCB Operator s Manual I gt lt l DIGITAL CONTROL INCORPORATED While roll offset is active press the right direction button to access the roll offset menu from the cable mode screen The Go option is now replaced by Stop The roll value displayed in the Set option will be that of the transmitter after roll offset is disabled Select Stop to disable roll offset and return to the cable mode display screen Select Set to program the roll offset to the displayed value Roll Offset Menu Disable or Set X Exit Exits the roll offset menu without saving changes Stop Disables roll offset Set Sets the displayed value as the roll offset Target Steering When a target depth has been programmed into the receiver and the remote is receiving telemetry data the Target Steering display screen appears Your remote display operator s manual provides detailed information on target steering
15. g transmitters accessories and software programs and modules Unless otherwise stated by DCI a Warranty Period of ninety 90 days shall apply to a a used DCI Product sold either by DCI or by an Authorized DCI Dealer who has been expressly authorized by DCI to sell such used DCI Product and b services provided by DCI including testing servicing and repairing an out of warranty DCI Product The Warranty Period shall begin from the later of i the date of shipment of the DCI Product from DCI or ii the date of shipment or other delivery of the DCI Product from an Authorized DCI Dealer to User 2 DCs sole obligation under this Limited Warranty shall be limited to either repairing replacing or adjusting at DCI s option a covered DCI Product that has been determined by DCI after reasonable inspection to be defective during the foregoing Warranty Period All warranty inspections repairs and adjustments must be performed either by DCI or by a warranty claim service authorized in writing by DCI All warranty claims must include proof of purchase including proof of purchase date identifying the DCI Product by serial number 3 The Limited Warranty shall only be effective if i within fourteen 14 days of receipt of the DCI Product User mails a fully completed Product Registration Card to DCI ii User makes a reasonable inspection upon first receipt of the DCI Product and immediately notifies DCI of any apparent defect and iii Use
16. giTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED gt Il Safety Precautions and Warnings Carefully review this manual and be sure you always operate your DigiTrak locating system properly to obtain accurate depth pitch roll and locate points If you have any questions about the operation of the system please contact DCI Customer Service for assistance General amp A gt gt All operators must read and understand the following safety precautions and warnings and must review this operator s manual before using a DigiTrak Locating System Serious injury and death can result if underground drilling equipment makes contact with an underground utility such as a high voltage electrical cable or a natural gas line Substantial property damage and liability can result if underground drilling equipment makes contact with an underground utility such as a telephone cable TV fiber optic water or sewer line Work slowdowns and cost overruns can occur if drilling operators do not use the drilling or locating equipment correctly to obtain proper performance DCI equipment is not explosion proof and should never be used near flammable or explosive substances In the event of electrostatic shock the display screen may go blank No data loss will occur Click the trigger to reset the receiver or toggle down to reset the remote display Hot surfaces can occur on cable transmitters if housing requirements
17. igiJrax MFCB Multi Function Cable Box Operator s Manual DIGITAL CONTROL eo dci digital control com INCORPORATED www DigiTrak com I gt CI DIGITAL CONTROL INCORPORATED 403 3400 00 C1 Oct 2013 2010 2013 by Digital Control Incorporated All rights reserved Trademarks The DCI logo CableLink DataLog DigiTrak Eclipse F29 F59 iGPS MFD SST target in the box Target Steering and TensiTrak are U S registered trademarks and DucTrak FBC FBPTM F Series FSD FasTrak LWD SBPTM SE SEDTM SuperCell and TeleLock are trademarks of Digital Control Incorporated Limited Warranty All products manufactured and sold by Digital Control Incorporated DCI are subject to the terms of a Limited Warranty A copy of the Limited Warranty is included at the end of this manual it can also be obtained by contacting DCI Customer Service 425 251 0559 or 800 288 3610 or at DCI s website www digitrak com Important Notice All statements technical information and recommendations related to the products of DCI are based on information believed to be reliable but the accuracy or completeness thereof is not warranted Before utilizing any DCI product the user should determine the suitability of the product for its intended use All statements herein refer to DCI products as delivered by DCI and do not apply to any user customizations not authorized by DCI nor to any third party pr
18. inal on the drill rig s battery or a metal contact point on the drill rig or drill stem Power cable with Deutsch DT06 4S Power and data cable with Deutsch DT06 4 pin connector on 2 wire cable 4S 4 pin connector on 4 wire cable Coaxial cable White Black m Remote display Antenna Serial port for SST laptop 12 28 VDC Housing to transmitter base is negative contact for grounding Cable transmitter Compression fitting Drill rod Housing MFCB Wiring Connections This cable is available as part number 460 3825 00 This cable part number 460 0002 00 is supplied with the MFCB The compression fitting shown in the preceding diagram is a non DCI part required to seal the transmitter from the drilling fluid Contact a drill or tooling manufacturer for information on compression fittings Connecting to the Remote Display For a freestanding remote display use the cable with identical four hole round connectors at both ends Align the key marks in the connector with the key slots in one of the power ports then push in and rotate the connector clockwise until it locks into place with a snapping sound For a panel mounted remote display remove the display from the console and unplug and remove the power cord from the drill rig s power port Plug the rectangular orange four hole connector of the new power and data cable shown on page 5 into the remote display s power port and ins
19. ll show roll in Y2 clock positions whereas the F Series displays show whole clock positions The number of clock positions displayed is a function of the transmitter Transmitter Pitch X 43 3 Receiver Type with Telemetry Channel Transmitter Roll Update Meter empty HI ECL 14 58 lt Output Voltage and Current Amperage 14 2V lt lt 15 0V Supplied by Cable Box 75F Input Voltage Range Approximate Supplied to Transmitter Eclipse Cable Mode Display 10 DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED gt Il The preceding screen shows an empty update meter which means the remote display is not receiving telemetry data The roll pitch and temperature are provided through the cable Depth information will display only when the remote is receiving telemetry data as indicated by bars in the update meter and the receiver is used to take a depth reading Roll Offset Use roll offset to match the transmitter s 12 o clock position with that of the drill head If roll offset is required it must be set on both the receiver see your operator s manual and the remote display To access roll offset on the remote display push the right direction button while in the Cable Mode screen The roll offset popup menu appears with three options Exit Go and Set Drill head s 12 RN m clock iti Transmitter s original roll Hari PO SK position when drill head is at 12 o clock shown at 75 Roll O
20. nder the above Limited Warranty void i alteration removal or tampering with any serial number identification instructional or sealing labels on the DCI Product or ii any unauthorized disassembly repair or modification of the DCI Product In no event shall DCI be responsible for the cost of or any damage resulting from any changes modifications or repairs to the DCI Product not expressly authorized in writing by DCI and DCI shall not be responsible for the loss of or damage to the DCI Product or any other equipment while in the possession of any service agency not authorized by DCI DCI reserves the right to make changes in design and improvements upon DCI Products from time to time and User understands that DCI shall have no obligation to upgrade any previously manufactured DCI Product to include any such changes THE FOREGOING LIMITED WARRANTY IS DCI S SOLE WARRANTY AND IS MADE IN PLACE OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IMPLIED WARRANTY OF NON INFRINGEMENT AND ANY IMPLIED WARRANTY ARISING FROM COURSE OF PERFORMANCE COURSE OF DEALING OR USAGE OF TRADE ALL OF WHICH ARE HEREBY DISCLAIMED AND EXCLUDED If DCI has substantially complied with the warranty claim procedures described below such procedures shall constitute User s sole and exclusive remedy for breach of the Limited Warranty DigiTrak MFCB Operator s
21. ng system before you use the cable box with your remote display Items such as compression fittings 10 gauge copper wire heat shrink butt splices and collector ring or mud swivel assemblies are not available from DCI Drill manufacturers or tooling manufacturers will have information on collector ring slip ring assemblies mud swivels and compression fittings Electrical supply houses will carry the rest of the equipment needed to connect the wires as drill rods are added to the drill string DCI offers an optional product called the CableLink connection system which eliminates the need for butt splices and heat shrinks The CableLink system is permanently installed into the drill pipe and the wire connection occurs automatically when the pipe ends are threaded together The SST system has very specific requirements for the transmitter housing and includes a laptop computer that is integral to the system Although some information regarding the SST is provided here please refer to the operator s manual provided with your SST system for complete setup and operation information All manuals are available at our website www digitrak com For full system compatibility updates to the software in your cable box and or remote display may be required For more information on obtaining operator s manuals CableLink or software upgrades visit our website or contact DCI Customer Service 4 DigiTrak MFCB Operator s Manual DIGITAL C
22. ntil you feel the index slot engage onto the housing key When the transmitter is properly keyed it will not rotate transmitter Never use the transmitter cable for pushing or pulling the transmitter into or from the housing See Appendix B on page 14 for STA D Warning Always use the extraction insertion tool to install or remove the cable information on repair or replacement of the cable DigiTrak MFCB Operator s Manual I gt CI DIGITAL CONTROL INCORPORATED If after installation the transmitters 12 o clock position does not match that of the drill head set the Roll Offset as described on page 11 Cable Mode Before using the Multi Function Cable Box set both your walkover receiver and remote display to work with a cable transmitter For your walkover receiver reference your operators manual For the remote display select Cable Mode from the main menu The cable system components must be properly connected with power supplied before this menu option is available If you cannot access the cable mode option you may need a software upgrade please contact DCI Customer Service Cable mode shown highlighted Enter Cable Mode Remote Display Main Menu with Cable Mode Highlighted Cable Mode Display Screen A cable transmitter is identified on the cable mode screen along with the receiver type The Eclipse and F Series remote displays have almost identical screens One notable difference is that the Eclipse display wi
23. oducts Nothing herein shall constitute any warranty by DCI nor will anything herein be deemed to modify the terms of DCI s existing Limited Warranty applicable to all DCI products The most recent version of this manual is available on DCI s website Compliance Statement This equipment complies with Part 15 of the Rules of the FCC and with Industry Canada license exempt RSS standards and with Australia Class License 2000 for LIPD low interference potential devices Operation is subject to the following two conditions 1 this equipment may not cause harmful interference and 2 this equipment must accept any interference received including interference that may cause undesired operation DCI is responsible for FCC compliance in the United States Digital Control Incorporated 19625 62nd Ave S Suite B103 Kent WA 98032 phone 425 251 0559 or 800 288 3610 Changes or modifications to any DCI equipment not expressly approved and carried out by DCI will void the user s Limited Warranty and the FCC s authorization to operate the equipment CE Requirements DigiTrak receivers are classified as Class 2 radio equipment per the R amp TTE Directive and may not be legal to operate or require a user license to operate in some countries The list of restrictions and the required declarations of conformity are available on DCI s website www digitrak com under the Service amp Support tab Click on DOWNLOADS and select from the CE Documents
24. p m Pacific Time and ask to speak with a customer service representative The above 800 number is available for use only in the USA and Canada Prior to returning any DCI Product to DCI for service you must obtain a Return Merchandise Authorization RMA number Failure to obtain an RMA may result in delays or return to you of the DCI Product without repair After contacting a DCI customer service representative by telephone the representative will attempt to assist you in troubleshooting while you are using the DCI Product during actual field operations Please have all related equipment available together with a list of all DCI Product serial numbers It is important that field troubleshooting be conducted because many problems do not result from a defective DCI Product but instead are due to either operational errors or adverse conditions occurring in the User s drilling environment If a DCI Product problem is confirmed as a result of field troubleshooting discussions with a DCI customer service representative the representative will issue an RMA number authorizing the return of the DCI Product and will provide shipping directions You will be responsible for all shipping costs including any insurance If after receiving the DCI Product and performing diagnostic testing DCI determines the problem is covered by the Limited Warranty required repairs and or adjustments will be made and a properly functioning DCI Product will be promptly shi
25. pped to you If the problem is not covered by the Limited Warranty you will be informed of the reason and be provided an estimate of repair costs If you authorize DCI to service or repair the DCI Product the work will be promptly performed and the DCI Product will be shipped to you You will be billed for any costs for testing repairs and adjustments not covered by the Limited Warranty and for shipping costs In most cases repairs are accomplished within 1 to 2 weeks DCI has a limited supply of loaner equipment available If loaner equipment is required by you and is available DCI will attempt to ship loaner equipment to you by overnight delivery for your use while your equipment is being serviced by DCI DCI will make reasonable efforts to minimize your downtime on warranty claims limited by circumstances not within DCI s control If DCI provides you loaner equipment your equipment must be received by DCI no later than the second business day after your receipt of loaner equipment You must return the loaner equipment by overnight delivery for receipt by DCI no later than the second business day after your receipt of the repaired DCI Product Any failure to meet these deadlines will result in a rental charge for use of the loaner equipment for each extra day the return of the loaner equipment to DCI is delayed 2 of 2 DigiTrak MFCB Operator s Manual Warranty
26. quipment Background noise must be minimal and signal strength must be at least 150 points above the background noise during all locating operations Because this equipment may generate use and radiate radio frequency energy there is no guarantee that interference will not occur at a particular location If this equipment does interfere with radio or television reception which can be determined by powering the equipment off and on try to correct the interference using one or more of the following measures o Reorient or relocate the receiving antenna o Increase the separation between the receiver and affected equipment o Consult the dealer DCI or an experienced radio TV technician for help o Connect the DCI equipment to an outlet on a different circuit Caring for Your Cable Box Do not disassemble The cable box contains no user serviceable parts Clean exterior with a damp cloth Do not submerge Do not pressure wash Ensure all ports remain clean and clear of debris by keeping protective caps on power ports and power post when not in use Use compressed air or a soft brush to remove debris from the power ports Use a wire brush to clean the power post Send in the Product Registration Card for the 1 year limited warranty Caring for Your Transmitter If the cable wire becomes exposed at the base of the transmitter the cable should be trimmed and reinstalled or replaced Parts for repairing or replacing the cable are pro
27. r complies with all of the Warranty Claim Procedures described below WHAT IS NOT COVERED This Limited Warranty excludes all damage including damage to any DCI Product due to failure to follow DCI s operator s manual and other DCI instructions abuse misuse neglect accident fire flood Acts of God improper applications connection to incorrect line voltages and improper power sources use of incorrect fuses overheating contact with high voltages or injurious substances use of batteries or other products or components not manufactured or supplied by DCI or other events beyond the control of DCI This Limited Warranty does not apply to any equipment not manufactured or supplied by DCI nor if applicable to any damage or loss resulting from use of any DCI Product outside the designated country of use By accepting a DCI Product and not returning it for a refund within thirty 30 days of purchase User agrees to the terms of this Limited Warranty including without limitation the Limitation of Remedies and Liability described below and agrees to carefully evaluate the suitability of the DCI Product for User s intended use and to thoroughly read and strictly follow all instructions supplied by DCI including any updated DCI Product information which may be obtained at the above DCI website In no event shall this Limited Warranty cover any damage arising during shipment of the DCI Product to or from DCI User agrees that the following will re
28. sing the 5 gt Allen wrench remove the brass set screw inside the transmitter base that holds the cable lead to the base Remove the old wire the 2 106 O ring and the screw insulator Removing the old wire from the base may require some force Install a new insulator and 2 106 O ring onto a new cable lead and insert the wire in the base Ensure only 5 46 of the wire coating is stripped back from the end of the tinned cable lead Install a new brass set screw using the Jo Allen wrench Push the cable lead in while tightening the set screw to ensure a good connection Using the standard screw driver or the x Allen wrench install a new white nylon set screw into the side of the transmitter base 14 DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED gt Il White nylon set screw use 1 8 Allen wrench or standard screw driver Set screw use 3 32 Allen wrench 2 106 O ring A Torx or buttonhead cap screws _C l BT 5 16 stripped Lock from wire end End cai Phillips head screws P 4 places Do not remove Transmitter base insulator Exploded View of Cable Transmitter Base and End Cap Assemblies 11 Install two new 2 021 O rings 12 Coat the top and sides of the base with a thin layer of Noalox to prevent electrical corrosion Do not substitute standard grease 13 Replace end cap and line up the screw holes on the base with the unthreaded holes on th
29. tall the other end into one of the cable box s power ports Your drill rig dealer can provide additional assistance if needed DigiTrak MFCB Operator s Manual 7 I gt lt l DIGITAL CONTROL INCORPORATED Connecting to the Cable Transmitter The cable transmitter must be grounded before it is connected to the cable box Without a proper ground no signal or data will be sent to the remote display The ground point on the cable transmitter is the metal end section of the tube where the wire exits Ground Transmitter wire FC Cable Transmitter When the cable transmitter is properly fitted into a housing the ground connection occurs automatically because the housing is grounded through the drill When testing the cable transmitter outside of a housing use a piece of wire to ground the transmitter to the negative terminal of the battery Once the cable transmitter is properly grounded in a housing connect it to the cable box by loosening the knob on the power post inserting the stripped wire end in the hole in the post and gently retightening the knob Connecting Transmitter Cable to Cable Box 8 DigiTrak MFCB Operator s Manual DIGITAL CONTROL INCORPORATED gt Il Installing Transmitter in Housing Cable transmitters require special rear load drill housings To prevent overheating and for optimum performance it is critical for the transmitter to be installed correctly An extraction insertion tool is provide
30. vided in the repair kit included with the system See Appendix B Transmitter Wire Repair or Replacement on page 14 Keep the SST transmitter at least 5 ft 1 5 m away from all magnets including the remote display and cable box which have magnetic mounts that will damage the transmitter A protective magnetic shield is provided with the SST transmitter and also available through any authorized DigiTrak dealer Place the magnetic shield on the end of the SST transmitter whenever the transmitter is not in use Send in the Product Registration Card for the 90 day limited warranty DigiTrak MFCB Operator s Manual 3 I gt CI DIGITAL CONTROL INCORPORATED Introduction The DigiTrak Multi Function Cable Box MFCB often referred to as just the cable box is an interface used with a variety of DigiTrak cable transmitters lt provides power to the cable transmitter and sends power and transmitter data to the remote display The cable box can be used with the following DigiTrak cable transmitters e Eclipse cable transmitter ECP e F Series cable transmitter FC e Eclipse steering tool transmitter SST The cable box can be used with the following DigiTrak remote displays e Free standing Multifunction Display MFDF e Multi Function Display MFD panel mounted and freestanding e F Series Display FSD This manual does not give instructions on how to operate your locating system Please read the operator s manual for your locati