K-BUS R Dimming Actuators User manual-Ver. 2

image

Contents

1. 26 4 9 Error Report 26 4 10 Normal operation signs 27 5 Parameters Setup Description 7 7 7 7 27 5 1 Introduction 27 5 2 Parameter Window Device general 28 5 3 Parameter Window CH X active 30 5 4 Parameter Window CHX general 31 5 5 Parameter Window dimming general 33 5 5 1 Setting of CH X dimming general 33 5 5 2 Parameter Window X dimming 35 5 5 3 Parameter Window X scene page
2. 23 3 5 1 ADLD 04 03 1 23 4 Application Programming Introduction 24 4 1 Switch 24 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 4 2 Relative dimming 24 4 3 Absolute dimming 25 4 4 Status Report 25 4 5 SCEne 25 4 6 Preset Value 25 4 7 Staircase Lighting Function 25 4 8 Reset
3. 7 7 7 14 3 1 Universal Dimming Actuator 14 3 1 1 KA D 0103 1 14 3 1 2 KA D 0203 1 15 3 1 3 KA D 0403 1 16 3 2 Dimming controller 4fold 1 10V 17 3 2 1 KA D 04 1 1 17 3 3 Dimming controller 4fold 0 1 10V 19 3 3 1 ADT V 04 16 1 19 3 4 LED Dimming Actuator 4fold 350mA 20 3 4 1 KA D 04 L1 1 20 3 5 LED Dimming Actuator 4fold 4A
4. 38 5 5 4 Parameter Window X preset 40 5 6 Staircase Lighting Mode 41 6 Communication Object Description 7 43 6 1 Communication object of Device General 43 6 2 General communication object of Dimming Actuator 45 6 3 Scene function communication object of Dimming Actuator 46 6 4 Preset value function communication object Dimming Actuator 46 6 5 Staircase Lighting Function communication object of Dimming Actuator 47 1 Introduction The dimming actuator hereinafter referred to as dimmer is a device dimming the luminaries directly by the data in the memory and the data is processed in advance in the programming software according to the distribution characteristics of the luminaries brightness The control circuit of dimmer transfers the brightness data value to output voltage or current to control the brightness of the luminaries
5. 0 and 1 which is able to call 2 different brightness values Options Dimming on Switching on softly When select dimming on the dimming time of object X preset 1 is the input time of Time duration of dimming Time entry multiplied by 2 When select switching on softly the dimming time of X preset is the default value 4 seconds 40 SSS a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Brightness value at obj 0 1 100 This parameter defines the brightness value when receiving 0 by X preset 1 Option 100 Brightness value at obj 1 1 100 This parameter defines the brightness value when receiving 1 by X preset 1 Option 1 100 Preset 1 can be set via the bus This parameter defines the possibility to change the preset value It is able change the preset value with enable and also start the communication object Set preset 1 which is used to save the current switch status as the new preset value It will save the current brightness status to the brightness value at obj 0 and replace that value with 0 will save the current brightness status to the brightness value at obj 1 and replace that value with 7 Options Enable Disable 5 6 Staircase Lighting Mode It is able to set the parameters of staircase lighting mode
6. Low a OUTPUT A Switch status A 1 bit Cr p Low E2 OUTPUT A Relative dimming A 4 bit G p Low ms OUTPUT A Brightness A 1Byte C f Low mja OUTPUT A Brightness status A 1 Byte C E T Low Fig 7 2 General communication object for each channel No Function Object Name Data Type Flags 1 Switch status X OUTPUT X lbit C R T This object is used to report the status of the current switch to the bus The dimmer will send 1 to the bus when the value of the brightness is larger than 0 0 to the bus with value of 0 The object will be enabled when selecting It is new status in the parameter Status report 0 Switch X OUTPUT X 1bit W C This object is used to receive the switch command to switch the dimmer actuator It will switch on the dimmer actuator with 1 off with 0 4 Brightness status X OUTPUT X 1byte C R T This object is used to send the brightness status of the current output to the bus whatever causes the changes of the value The object will be enabled when selecting Transmit new brightness in the parameter Brightness value OBJ transmit after dimming 3 Brightness X OUTPUT X 1byte W C It is used to receive the brightness value to switch the dimmer actuator switching on the actuator when the received value is larger than 0 off or stay to the lower threshold value with 0 which is defined b
7. On 35mm DIN rail 90x143x60 mm 0 5kg Dimming Actuators DIAS cos te AY AE lt 93 except dewing 2 3 Dimming controller 4fold 0 1 10V ADT V 04 16 1 2 3 1 Technical data Power supply Operating voltage Output Number Output voltage Switch current Connections EIB KNX Outputs Operation and Button and red LED display Green LED flashing Temperature Operation Storage Transport Ambient Humidity Type of protection IP 20 EN 60529 Mounting On 35mm DIN rail Dimension 90x143x60 mm Weight 0 4kg www video star com cn marketing video star com cn Tel 21 30V DC via the EIB bus 4 channel switching dimming 1 10V DC max 100mA per channel 16A 250V AC If fluorescent lamp allowable Max current is10A 250V 140uF KNX EIB bus connection terminal Using screw terminals For assigning the physical address Indicate the application layer running normally 1S wen ar ds AE D XC cost ob C 25 C 70 C lt 93 except dewing 12 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 2 4 LED Dimming Actuator 4fold 350mA KA D 04 L1 1 2 4 1 Technical data Power supply Operating voltage 21 30V DC via the EIB bus Input 12 48V DC Output 4 channels Each channel with two outputs Current Constant current 350mA 700mA Load voltage 3 48V DC Safety Short circuit and excess temperature protection Connections EIB KNX EIB bus connection terminal Inputs outputs Using screw terminals Ope
8. The dimmers have universal dimmers 1 10V DC dimmer 0 1 10V DC dimmer 350mA LED dimmer and 4A LED dimmer The universal dimmers carry out dimming via phase modulation which have 3 categories 1 channel 3 SSS a CO a ar www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 2 channels and 4 channels Max Power of each channel is 500W for 1 channel and 2 channels dimmers and Max Power of each channel is 400W for 4 channels dimmer It is able to dim one independent group of luminary by l channel dimmer 2 independent groups of luminaries by 2 channels dimmer and 4 independent groups of luminaries by 4 channels dimmer 1 10V DC dimming controller with standard DC 1 10V control interface has 4 independent channels and one channel can control up to 23 electronic control gears ECG such as 23 ECG 18W 14 ECG 36W 11 ECG 58W or 23 ECG T5 24W The input need connect a 230V AC operating voltage for the device 0 1 10V DC dimming controller with standard DC 0 1 10V control interface has 4 independent channels and one channel can control up to 23 electronic control gears ECG such as 23 ECG 18W 14 ECG 36W 11 ECG 58W or 23 ECG T5 24W There is no additional voltage input The 350mA LED dimmer with LED constant current drive can drive LED directly has four channels each channel is independent and with two independent output The output current of each channel c
9. 9 2 1 1 Technical data 9 2 1 2 Load type 10 2 1 3 Dimming operation mode 11 2 2 Dimming controller 4fold 1 10V KA D 04 T1 1 11 2 2 1 Technical data 11 2 3 Dimming controller 4fold 0 1 10V ADTV 04 16 1 12 2 3 1 Technical data 12 2 4 LED Dimming Actuator 4fold 350mA KA D 04 L1 1 13 2 4 1 Technical data 13 2 5 LED Dimming Actuator 4fold 4A ADLD 04 03 1 14 2 5 1 Technical data 14 3 Dimension and Connection Diagram
10. A dimming general amp dimming Acscene page Low dimming threhold preset 17127 0 4 749 9 CH B general Relative dimming Upper dimming threhold 128 255 50 2 100 If dimming down and value lt low dimming threhold output switch Output switch on after receipt of dimming up telegram Brightness value Lower dimming threshold 17127 0 4 749 9 Upper dimming threshold 128 255 50 2 100 If output on receipt of Brightness value 0 output switch On receipt Brightness Value gt 1 output switch on 35 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Fig 6 5 Parameter window X dimming This window is used to set the parameters in the brightness dimming mode There are 2 type of brightness dimming mode Relative dimming and Brightness value Relative Dimming low dimming threshold 1 127_ 0 4 49 9 This parameter defines the low threshold value of the relative dimming When it is smaller than the low threshold it is not allowed to dim DOWN only to dim UP the range is 1 127 0 4 49 9 Supposing the low threshold is 50 if the current brightness value is smaller than 50 so it is not allowable to dim DOWN until dimming UP to above 50 upper dimming threshold 128 255_ 50 2 100 This parameter defines the high threshold value of the relati
11. with LED constant voltage drive can drive LED directly has four channels each channel is independent The output can connect with some big power dimmable LED lights These LEDs can be switched dimmed recall scene or other operations via the bus The devices adopt screw terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal The input need connect a 12V 24V DC operation voltage The following list provides a functional overview Switching the LED light Relative dimming Absolute dimming Status report error report Setting 15 scenes Staircase lighting function Bus recovery or reset function e Preset value and modify preset value functions lt gt Switch relative dimming via manual buttons The above function of parameters to configure and use are described in the chapter 5 The device has own database file vd4 ADLD 04 03 1 There is added a manual operation function in the normal dimming mode it is invalid in the staircase lighting mode Switch via a short operation of manual buttons relative dimming via a long operation and in the case of the bus voltage fail the manual operation is invalid 8 a eee www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 2 Technical characteristic 2 1 Universal Dimming Actuator KA D xx03 1 2 1 1 Technical data Power supply
12. 00ms In this system the function of frame speed is unavailable 6 Error report 28 SSS ee SS SS ae www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators This parameter defines the error report status of the system controlled by 1 byte data bit Options Disable Enable There is an error report after the malfunction in the system when selecting enable otherwise there is no report when selecting disable It will send an alarm to switch off the device if with over temperature overload or short circuit In the case of the universal dimmers the stabilization time of temperature is 1min in the program application When the temperature is higher than 70 C lasted for more than 1min the dimmer changes its output into 30 of the current brightness when the temperature dropped to 60 C the dimmer changes its output into 50 of the current brightness When the temperature is higher than 90 C lasted for more than 1min the output turns off and cannot start until the temperature drops below 90 C the output can be restart via sending the output command If the temperature fluctuations at the critical point the stabilization time will re timing Only when the stabilization time 1min has elapsed the current output brightness changes In the case of the 350mA LED dimmer when the radiator temperature is higher than 75 C the brightn
13. 7 to the BUS when the current brightness value is greater than 0 send 0 when the value is equal to 0 Options Nothing It s new status It will not send any report of the current switch status with Nothing And send a status changed report of switch to the BUS with Its new status Note if selected it s new status the object Switch status X and object Switch X cannot be linked together by a same group address or lead to the device internal loopback and enter into endless loop to make the bus system crash 32 SSS a CO a Sa a ae a amy www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 5 5 Parameter Window dimming general 5 5 1 Setting of CH X dimming general W 1 1 5 KA D 02 XX 1 din rail dimmer Device general A dimming general CH A general Time duration of dimming 2 A dimming Time entry 2 A scene page A preset CH B general Switch on via OBJ switch with Preset brightness value Preset switch on brightness 100 1 100 Reaction on receipt of switch on value Switch on softly Reaction on receipt brightness value Dimming on Switch OFF mode Switch off softly After bus recover switch on with Last brightness Bus recover preset brightness value 0 0 100 Staus repon aitor telegram Transmit only after change Fig 6 4 Par
14. 8620 39338465 Dimming Actuators GVS K BUS KNX EIB 3 5 LED Dimming Actuator 4fold 4A 3 5 1 ADLD 04 03 1 Dimension drawing i 72 0 mm gt 64 2 mm 90 0 mm Connection Diagram PETER ee ENN A B C D Pe ee 00000 Qro gt A ElJ KNX amp 12 24v DC 12 24V DC KNXBUS EIB KNX bus connection terminal Programming button for assigning the physical address 23 Tel 8620 39338986 Fax 8620 39338465 www video star com cn marketing video star com cn GVS K BUS KNX EIB Dimming Actuators Red LED for entering the physical address green LED for application layer running normally Indicate over voltage when the load voltage gt 26V DC the LED is ON and the output is off Indicate over temperature when the Temp gt 70 C the LED is ON and the brightness value is lowered 5 per f 1 C Output load terminals LEDs of indicating output status for each channel Manual buttons switch via short operation relative dimming via long operation Input terminals input voltage 12 24 V DC 4 Application Programming Introduction It is able to set different parameters to every output channel and control various targets by modifying the setup of the internal parameters 4 1 Switch The output can be switched ON or OFF by 1 bit data It is able to set the brightness value as the last one or a defined one 1 100 when switching on the luminaries It i
15. E T www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators This function is used to select a scene to set the brightness value dimming time and dimming mode Options Scene 1 Scene 2 Scene 15 The setting parameters for the other 15 scenes are shown as below Reaction on receipt scene Y The function defines the dimming mode of the set scene Y means the scene that needs setting 1 15 The Y shown as below has the same meaning Options Dimming on Switch on softly The option Dimming on means the set scene dimming time is the set time of the parameter Scene Y duration time entry 2s the input time multiplies 2 The option Switch on softly means the scene dimming time is the default time 4S Scene Y duration _ time entry 2 S This function defines the dimming time of the set scene which is the input value multiplies 2s the maximum input time is 255s Scene Y brightness value_ O 100 This function defines the brightness value of the set scene with range from 1 to 100 Assignment to Scene number 1 64 This function distributes the scene number of the set scene that means the communication object Scene save X will call the scene by the allocated scene number Options Not assignment Assignment to scene 1 Assignment to scene 2 Assignment to scene 64 Note the parameter setting o
16. ON 4 9 Error Report The dimmer offers the possibility of reporting the error status of the system the data type is 1 byte Table 3 Error report of the universal dimmer Data bit BitO Bitl Bit2 Bit3 Bit4 Bit5 Target Name CH 1 CH 2 CH 3 CH 4 The radiator The radiator Short circuit Short circuit Short circuit Short circuit temperature temperature Function over load over load over load over load more than more than 70 C 90 C www video star com cn marketing video star com cn 26 Tel 8620 39338986 Fax 8620 39338465 GVS K BUS Table 4 Error report of the 350mA LED dimmer KNX EIB Dimming Actuators Data bit BitO Bitl Bit2 Bit3 Target Name B C channels B C channels A D channels A D channels The radiator The radiator The radiator The radiator Function temperature temperature temperature temperature E more than 75 C more than 90 C more than 75 C more than 90 C Table 5 Error report of the 4A LED dimmer Data bit BitO Bitl Bit2 Bit3 Bit4 Bit5 Target Name A channels B channels C channels D channels Device Device The radiator The radiator The radiator The radiator Overvoltage Over temper Function temperature temperature temperature temperature the input gt 26V ature gt 70 C more than 75 C more than 90 C more than 75 C more than 90 C DC 4 10 Norm
17. S KNX EIB Dimming Actuators 4 3 Absolute dimming 8 data bits control it is able to dim to the needed brightness value by changing the brightness parameters The setting of the parameters is similar as relative dimming with the brightness value range one low threshold value and one high threshold value And it is not allowed to change the brightness value beyond the set range the max range is from 0 to 255 This function offers the possibility to dim UP or DOWN to 0 gradually to the target value by setting the delay time or the default time The high and low threshold value limits the total output of the dimmer any brightness value beyond the range is not valid When the output is 0 it is able to set switching off the luminaries or remaining to a lower brightness value and also in this status it is optional to switch on the luminaries by receiving the message absolute dimming 4 4 Status Report 1 data bit the dimmer offers the possibility whether sending the latest brightness value report of the controlled target and the changed report of the switch status to the BUS 4 5 Scene 8 data bits control the dimmer offers 15 1 15 scenes for selection It is possible to set ONE brightness value and the gradual change time of ON for each scene After setting it is easy to call any favorite scene 1 in the highest bit of the scene command it means saving command to save the current brightness value to the relevant sc
18. Staircase lighting Deactive Brightness value OBJ transmit after dimming Nothing Status report Nothing Fig 6 3 Parameter window CH X general Staircase lighting Options Actived Deactive It is in the status of staircase lighting control with Actived and in the normal dimming control with Deactive Brightness value OBJ transmit after dimming This function is used to report the latest brightness value When enable this function it will send a frame to the BUS no matter what happen to make the brightness value changed Options Nothing 31 ee a a a a a ae a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Transmit new brightness It will not send any report of the current brightness value with Nothing And send a frame to the BUS to report the current brightness value no matter what happens to make the brightness value changed with Transmit new brightness Note if selected transmit new brightness the object Brightness status X and object Brightness X cannot be linked together by a same group address or lead to the device internal loopback and enter into endless loop to make the bus system crash 6 Status report This function defines whether report the switch status to the BUS when the setup object switch is changed Send
19. VS K BUS KNX EIB Dimming Actuators 230V 50Hz 2 x 500 W VA Connection Diagram L1 L2 L3 6A 1P 230V 50Hz 2 x 500 W VA EIJ Knx CE KNX BUS The identity of all universal dimmers is the same take 2 flod dimmer for example Label carrier Programming button Red LED for entering the physical address green LED for application layer running normally bus connection terminal input output load terminals 3 1 3 KA D 0403 1 Dimension drawing 16 a EE www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 60 0 mm T ji et We 230V 50Hz 4 x 400 W VA Tj Connection Diagram L1 L2 L3 N 16A 1P AC230V4f A EIJ KNR CE Q Ooo OE y KNX BUS 3 2 Dimming controller 4fold 1 10V 3 2 1 KA D 04 T1 1 Dimension drawing 17 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 1 10V DC 100mA 16A 250V EIJ KNR CE Connection Diagram ti L1 L2 L2 L3 L3 N N AC230V INPUT 16A 250V Wi gi T Sg eor L N PE 1 10V 5 TER EVG wa 8 EIJ KNR CE Label carrier Programming button Red LED for entering the physical address green LED for application layer running normally bus connection terminal input
20. Working voltage 21 30V DC via EIB bus Input voltage 230 V AC 50 60Hz Output KA D 0103 1 1 channel Max output capacity 500W per channel KA D 0203 1 2 channels Max output capacity 500W per channel KA D 0403 1 4 channels Max output capacity 400W per channel Output voltage 230 V AC 50 60Hz short circuit and excess temperature protection Max Leakage Loss 5W Connections EIB KNX EIB bus connection terminal Input Load Circuits Screw terminals Operation and Button and red LED For assigning physical address display Green LED flashing Indicate the device running normally Type of IP 20 EN 60 529 protection Temperature Operation 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Ambient Humidity lt 93 except dewing Mounting On 35mm DIN rail Dimensions KA D 0103 1 90x71 5x60 mm KA D 0203 1 90x143x60 mm KA D 0403 1 90x214 5x60 mm CE norm In accordance with the EMC guideline and the low voltage guideline Certification EIB KNX certified 9 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Weight KA D 0103 1 0 3kg KA D 0203 1 0 5kg KA D 0403 1 0 75kg 2 1 2 Load type Resistive loads Capacitive loads Inducive loads Note it is however not permitted to connect inductive capacitive and resistive loads together at the same output i e only permitted to connect same type lo
21. Yes The option No means the dimmer remains the output 0 when receiving the message of 100 if the output is 0 The option Yes means the output is the input brightness value when the receiving value is greater or equals to 1 if the input brightness value is smaller than the brightness low threshold the output is the brightness low threshold 5 5 3 Parameter Window X scene page W 1 1 5 K D 02 XX 1 din rail dimmer Device general A scene page CH A general amp dimming general DES A dimming Scene function is J A scene page A preset CH B general Scene select 1st Scene v Reaction on receipt scene 1 Dimming on Scene 1 duration 1 Time entry 2 Scene 1 brightness value 100 0 100 Assignment to Scene number 1 not assignment C Jea Joa Fig 6 6 parameter window X scene page This parameter shown in Fig 6 6 defines the scene function totally 15 scenes from 1 to 15 It is able to set 15 scenes simultaneously and call any one of them by control panel when needed Scene function is The function defines the enable or disable of the scene function Options Enable Disable The option Enable means it is able to use the scene function of the dimmer X the window shown in Fig 6 6 will be displayed after selecting If there is no need to use the function of scene so select Disable option Scene select 38 O e a a E
22. ads for a output 10 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB 2 1 3 Dimming operation mode Dimming Actuators Dimmer operation is in leading or trailing edge Explanation of the dimming system dimmer will be on at the zero crossing point seen below Figure During this moment the voltage is very low and there is no current impact to the load which is able to not only extend the lamp life but also reduce disturb to the power grid J Jes 2 2 Dimming controller 4fold 1 10V KA D 04 T1 1 2 2 1 Technical data Power supply Operating voltage Input voltage Output Number Output voltage Connections Operation and display Temperature www video star com cn Switch current Safety EIB KNX Inputs outputs Button and red LED Green LED flashing Operation Storage 21 30V DC via the EIB bus 100 240V AC 4 channel switching dimming 0 10V DC max 100mA 16A 250V AC If fluorescent lamp allowable Max current is 4A Short circuit protection KNX EIB bus connection terminal Using screw terminals For assigning the physical address Indicate the application layer running normally p 16 coo 45 C BAS oo te SS AE 11 marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS Ambient Type of protection Mounting Dimension Weight KNX EIB Transport Humidity IP 20 EN 60 529
23. al operation signs 1 bit data The sign will be report periodically to the Bus when the dimmer is working normally 5 Parameters Setup Description 5 1 Introduction 2 operation modes main function per output Normal Dimming This mode is mainly used to control the normal luminaries system which can set the output time and the brightness value of the dimmer dim UP or DOWN with the function of relative dimming and also call the set brightness values from the scene function until dim to the required environment Staircase Lighting The mode is mainly used to control the staircase luminaries Switch ON the staircase luminaries and switch OFF automatically after a certain period or switch OFF by manually 27 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 5 2 Parameter Window Device general The parameter settings may have difference for different devices If the device has not the follow parameters it will have not the function of the parameter W 1 1 5 EA D 02 28 1 din rail dimmer Device general Device general CH A general CH B general Telegram rate No limit Error report Disable Send object In operation no Fig 6 1 Parameter window Device general ry Telegram rate This command is used to set the frame speed Options No limit Delay 100ms Delay 200ms Delay 7
24. alue 0 cyclically or Send value 1 cyclically to define the time interval of sending telegram Sending cycle time in s 1 65535 This parameter defines the time interval of the telegram to report the normal working condition of the dimmer Options 65535s 5 3 Parameter Window CH X active The parameter window of CH X active can be seen in Fig 6 2 which activate or deactivate the output of Channel X The CH X or X in the following text means any one output of the dimmers The functions are describes as below and all the channels have them same functions setup W 1 1 5 KA D 02 48 1 din rail dimmer Device general i CH A general CH general CH B general CHA active Deactive Fig 6 2 Parameter window CH X active CH X active 30 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Options Actived Deactive The window shown in Fig 6 3 will pop out when choosing Active In this window it is able to set the working mode the current brightness status and the switch status report It will become null with Deacitved selection 5 4 Parameter Window CHX general E 1 1 5 EA D 02 22 1 din rail dimmer Device general CH A general CH A general Acdimming general A dimming CHA active v scene page preset CH B general
25. ameter window CH X dimming general Time duration of dimming time entry 2 It is used to set the dimming time duration No matter it is brightness dimming or switch dimming when choosing the dimming time duration for dimming on or dimming off the time is equal to this input value multiply 2 seconds and the maximum input time is 255s Switch on via OBJ switch with It is used to select the brightness value is the last one or the preset one when using the switch mode to switch on the luminaries Options Preset brightness value Last brightness value The option Preset brightness value means the brightness value is the preset value when switching on the luminaries by switch mode When the brightness low threshold value is greater than the switch preset value the brightness value of the luminaries is the low threshold value after switching on when the switch preset value is greater than the high threshold the brightness value is the high threshold one after switching on The high and low 33 E E ae T www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators threshold of the brightness are shown in the parameter window CH X dimming see Fig 6 5 The option Last brightness value means the brightness value is the last status value which is not equal to 0 If the behavior of switching on the luminaries in switch mod
26. an be set by linked switch current button and channel switch current button and can output 350mA 700mA or 700mA 1A The 4A LED dimmer with LED constant voltage drive can drive LED directly has four channels each channel is independent The input need connect a 12 24V DC operating voltage for the device the output voltage depends on the input voltage The Dimmer is a modular installation device for fixed installation in dry rooms It fits on 35mm DIN rails in power distribution boards or closed compact boxes It can be programmed it can be use to customize the rooms environment to build the various scenes such as WATCH MOVIE ENTERTAMENT DINNER and REST and so on it s brightness value can be set as any value 1 100 it is able to set the duration time to dim up or down to the target brightness value and the gradual change speed to extend the luminaries life and save energy and so on It is able to use the Engineering Tool Software ETS ETS2 version or more with a VD2 VD3 file to allocate the physical address and set the parameters This manual describes a series of dimmers Different dimmers apply to connect different type of lighting but their functions are similar just in use you need to note the type of connected electrical load thus reasonable select them and note their technical performance If the technical performance of the selected load is not consistent with the technical performance of the dimmer it is possible to cause damage t
27. code as FXKNNNNNN F 0 transfer scene F 1 save scene X Un used not affect the results NNNNNN scene number 0 63 The parameter setup is 1 64 Table 7 3 Scene function communication object 6 4 Preset value function communication object Dimming Actuator E Hame Object Function Description Group Add Length C R W T V Data Type Priority ERIO OUTPUT A Set preset 2 ibit C Low Gs OUTPUT A A Preset 2 1 bit C Tos Low ms OUTPUT A Set preset 1 1 bit E P er Low ET OUTPUT A A Preset 1 1 bit Css E Low Fig 7 4 preset function communication object No Function Object name Data type Flag 7 X preset 1 OUTPUT X lbit W C 46 pO a a a a a a a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators It is the communication object of preset 1 and call the preset value When the object receives the logical value of 0 the brightness value of dimming are defined by Brightness value at obj 0 when the object receives the logical value of 1 the brightness value of dimming are defined by Brightness value at obj 1 This object will be started after activating preset1 8 Set preset 1 OUTPUT X Ibit W C This object is used to modify brightness value of preset1 It will start the parameter preset1 can be set via the bus with Enable Via this
28. cover switch on with 34 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators It means in the normal situation the behavior after the BUS reset is the brightness value before power off or the preset value Options Preset brightness value Last brightness value The option Preset brightness value means the brightness value after the BUS power recovers is the input preset brightness value in the bus recover preset brightness value 0 100 If the input preset value is smaller than the low threshold the value after the BUS power recovery is the low threshold if the preset input value is greater than the high threshold the value after the BUS power recovery is the high threshold The high and low threshold are shown in the parameter window CH X dimming see Fig 6 5 The option Last brightness value means the brightness value is the last value before power off after BUS power recovery It also carry out a bus reset operation after downloading the parameters Bus recover preset brightness value 0 100 It is used to set the brightness value during the BUS power recovery and the range is 0 100 Status report after telegram to obj switch It is a backup parameter do not care it 5 5 2 Parameter Window X dimming 1 1 4 KA D 02 xx 1 2 fold dimmer Device general A dimming CH A general
29. d off when the brightness value of the staircase goes down to 20 Brightness value for staircase lighting 20 100 The function defines the brightness value of the staircase when switching on the luminaries by switch mode Staircase lighting after bus voltage recovery The function defines the status of the staircase luminaries after the BUS power recovery Options Switch on 42 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Switch off The option Switch on means switch on the staircase luminaries after the BUS power recovery duration base factor It is to use the parameter Time for dimming down to 20 Duration Entry 2 to set the DOWN time The option Switch off means switch off the staircase lamps after the BUS power recovery Staircase value at permanent on 20 100 The function defines the output status of the staircase luminaries as a fixed brightness value It will not switch off the staircase luminaries without receiving the OFF message from permanent on permanent on is another output mode of the staircase luminaries The DOWN time of turning off the luminaries is set by the parameter Time for dimming down to 20 Duration Entry 2 It will switch off the luminaries when going down to 20 The range is 20 100 On reception switch OBJ 0 switch off enable Optio
30. e after the BUS reset and the luminaries during BUS reset are off so the brightness value is the default brightness value 128 Other cases the brightness value is the last status value which is not equal to 0 on switching mode Preset switch on brightness 100 It is used to set the brightness value when switch on the luminaries in switch mode with the setting range 1 100 Reaction on receipt of switch on value It shows the time duration to switch on the luminaries in switch mode Options Dimming on Switch on softly The option Dimming on means the switch dimming time is the input time multiplies 2 Then option Switch softly means the default dimming time is 4s Reaction on receipt brightness value It is used to set the brightness value in the brightness dimming mode Options Dimming on Switch on softly The option Dimming on means the brightness dimming time is the input time multiplies 2 Then option switch softly means the default dimming time is 4s Switch off mode It shows the time duration to switch off the luminaries in switch dimming mode Options Dimming off Switch off softly Switch off instantly The option Dimming off means the switch dimming time is the input time multiplies 2 The option switch softly means the default dimming time is 4s The option switch off instantly means the luminaries are switch off immediately After bus re
31. ene 4 6 Preset Value The dimmer can preset scene the object directly through 1bit data to transfer the preset scene or through 1bit data to let favorite scene to replace original preset scene There are two preset values per output there are two brightness values can be transfer for each preset value Such as in theater we need a relatively bright lighting effect when coming in we can through transfer the first brightness value to be achieved this effect when the movie starts playing we need a relatively dark lighting effect we can through transfer the second brightness value to be achieved We can return to the previous brightness value when the movie ended 4 7 Staircase Lighting Function The dimmer offers the function of staircase lighting control besides the normal lighting control The staircase lighting function serves to switch off the lighting directly until dimming DOWN to 20 of the brightness value after a set period It is able to set the brightness of the luminaries the duration of the light ON 25 a a ee ee www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators the time to dim down to 20 separately In this function it uses 1 data bit control the targets directly by setting a permanent fixed value to the output of the staircase luminaries The steps of staircase lighting control the staircase luminaries will be switched on
32. er load No 3 is 1 Channel 4 short circuit or over load No 4 is 1 the radiator temperature more than 70 C No 5 is 1 the radiator temperature more than 90 C Other are not used 350mA LED dimmer 8 bits are 0 that is the telegram 0 the system working normally No 0 is 1 the radiator temperature more than 75 C for B C channels middle PCB No is 1 the radiator temperature more than 90 C for B C channels middle PCB No 2 is 1 the radiator temperature more than 75 C for A D channels bottom PCB No 3 is 1 the radiator temperature more than 90 Cfor A D channels bottom PCB Other are not used 4A LED dimmer 44 LL eee a a a a a a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 8 bits are 0 that is the telegram 0 the system working normally No 0 is 1 overload for A channel No 1 is 1 overload for B channel No 2 is 1 overload for C channel No 3 is 1 overload for D channel No 4 is 1 overvoltage for the device the input voltage gt 26V DC No 5 is 1 over temperature for the device gt 70 C Other are not used Table 7 1 Communication object table of Device General 6 2 General communication object of Dimming Actuator N Name Object Function Description Group Add Length C R W T U Data Type Priority Ejo OUTPUT A Switch A 1 bit Cc
33. ess value of LED lighting will come down if the temperature continues to rise the brightness value will continue to fall The output is turned off in 90 C Note the 350mA LED dimmer only report over temperature Because of constant current output there is not overload if short circuit automatic disconnect output but no report In the case of the 4A LED dimmer when the radiator temperature is higher than 70 C the brightness value of LED lighting will lowered 5 per ft 1 C if the temperature continues to rise the brightness value will continue to fall The output is turned off in 80 C Sending cycle time in s 1 65535 This parameter defines the time interval that the dimmers send the error report by the bus which will be started when enabling the error report Options 65535s output voltage type This parameter is used to set the output voltage type of 0 1 10V DC dimming controller Options 0 10V 1 10V Send object in operation 29 piren ee O a ee ee E www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators This command is used to send messages 1 or 0 to the BUS periodically to check the device whether is working or not Options No Send value 0 cyclically Send value 1 cyclically It will not send any telegram with No and show the following parameters with Send v
34. for a certain time this time can be set if the controlled target receives the message of 1 these luminaries will be switched on again when receiving another message during this period The luminaries will be switched off when they are dimmed down to 20 of the brightness value the dim down time can be set after this period or switch off the luminaries by sending message 0 to the controlled target The luminaries will be off after dimming down to 20 when receiving the message 0 the same dimming down time as above When enabling the function On reception switch OBJ 0 switch off it is able to use the function switch off to turn off the output in the status of permanent on or change the status from switch on to permanent on message 1 means ON 0 means OFF 4 8 Reset When the BUS is power off all the outputs are switched off the current brightness value will be saved to the memory of the dimmer When the BUS voltage is recovered the brightness status may be the last brightness value or the preset brightness value When the BUS is power off it may have the following situation occurring In the normal mode 2 optional behaviors after the BUS voltage recovery are the last brightness value before power off or the set value In the staircase lighting mode the behavior after the BUS voltage recovery is ON or OFF No output when it is OFF start the behavior switch 1 when it is
35. from relative dimming if the output is 0 Options No Yes 36 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Supposing the current output is 0 If it is NO the output still remain 0 even when the target receives the message dimming UP if it is YES it will dim the luminaries to the modified value when receiving the dimming up message If the value after dimming up is smaller than the brightness low threshold it will be dimmed to the low threshold directly If the value after dimming up is greater than the brightness high threshold it will be dimmed to the high threshold directly Brightness Value The high and low threshold value limits the high and low output value It is not allowed to change the brightness value if it is beyond the high and low threshold which will be invalid For example in Fig 6 5 the value is set as 1 255 If the low threshold value is set as 50 and the high threshold is 200 the brightness value 210 will be invalid The luminaries will be dimmed from the low threshold directly when the brightness value goes up from 0 the luminaries will be dimmed from the high threshold directly when the brightness values goes down from 255 low dimming threshold 1 127 0 4 49 9 This function defines the low threshold of the dimmer and the range is 1 127 It is going to start dimming from the low t
36. hreshold Supposing the current brightness value is 0 the low threshold is 50 and the high threshold is 200 If receiving the message 30 the brightness value will go to 50 directly without gradual change if receiving the message 60 so the brightness value will first go to 50 and then go up to 60 gradually if the current value is 100 and the target value is 30 so the value will go from 100 to 50 and the brightness value is 50 upper dimming threshold 128 255 _ 50 2 100 This function defines the high threshold of the dimmer and the range is 128 255 Supposing the low threshold is 50 and the high threshold is 200 If the input brightness value is greater than 200 it will go to 200 directly If output on receipt of brightness value 0 output switch This function defines it is available or not to switch off the output by the defined brightness vale 0 Options Off To low threshold value The option Off means the output is 0 when the brightness value is 0 The option To low threshold value means the output is the low threshold when the value is 0 6 On receipt brightness value gt 1 output switch on This function defines it is available or not to switch on the output by brightness dimming mode when the output is 0 37 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Options No
37. imming Controller 4fold 1 10V 1 10V DC control device with standard DC 1 10V control interface can be connected with electronic dimmable ballast EVG or other devices with 1 10V interface to control the lights such as dimming scenes switching and so on The 1 10V DC control device has embedded switching relays for 23 ECG 18W 14 ECG 36W 11 ECG 58W or 23 ECG T5 24W Each channel offers control voltage up to 23 electronic control gears ECG The devices adopt screw terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal The input need connect a 230V AC operation voltage The following list provides a functional overview Switching the light Relative dimming Absolute dimming Status report Setting 15 scenes Staircase lighting function 5 _ _ _ a a O a a L a SS we www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators lt Preset value and modify preset value functions The above function of parameters to configure and use are described in the chapter 5 the database file vd2 of the device is the same with KA D 0403 1 But there is not the error report function for the device and in the normal mode there is not reset function after bus voltage recovery i e the brightness status will not restore the last brightness value Note Some lights cannot be tur
38. in Fig 6 7 41 pirme a a a a a a eae a a ee ee www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators W 1 1 5 KA D 02 XX 1 din rail dimmer Device general A staircase lighting CH A general A staircase lighting CH B general Duration of staircase lighting Base Duration of staircase lighting Factor Factor 1 127 Duration Base Factor Time for dimming down to 20 Duration Entry 2 Brightness value for staircase lighting 100 20 100 Staircase lighting after bus voltage recovery Switch off Staircase value at permanent on 100 20 100 On receiption switch OBJ 0 Enabh switch off enable Enable Fig 6 7 parameter window CH X staircase lighting Duration of staircase lighting Base Set the time of base 1 0 s 2 1 s 1 1 min 1 2h Duration of staircase lighting Factor Set the time of factor 1 255 S When switch on the staircase luminaries by switch mode the ON duration time is duration base factor It will switch off the luminaries when the brightness goes down to 20 gradually after the ON duration time Time for dimming down to 20 Duration Entry 2 This function defines the time that the brightness value of the staircase lamps goes down to 20 Duration Entry 2 The maximum input value is 255s The luminaries will be switche
39. ion of the electronic manual buttons relative dimming via a long 6 _ _ _ a a ee ee eS ee www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators operation and in the case of the bus voltage fail the manual operation is invalid There is also mechanical manual operation function and it can switch on or off the output at any time Note Some lights cannot be turned off completely by dimming In this case you can turn off the lights via switching 1 4 LED Dimming Actuator 4fold 350mA The dimmer with LED constant current drive can drive LED directly has four channels each channel is independent and with two independent output The output current of each channel can be set by linked switch current button and channel switch current button and can output 350mA 700mA or 700mA 1A needs attention when the output current exceeds the rated current of the load the load probably will burn out for example cannot use a 700mA output to drive 350mA LED Meantime in the case of full load if all LEDs are 350mA the dimmer can output 8 folds but if some LEDs are 700mA or 1A it cannot output 8 folds in some configuration or the LED cannot reach expectant brightness value The details are in section 3 3 When the output current is set manually its value can be known via relevant indicators the details in section 3 3 The output can connect with s
40. ndicate LED A Al A2 KEY1 LED1 B B1 B2 KEY2 LED2 C C1 C2 KEY3 LED3 D D1 D2 KEY4 LED4 Specific output current for each channel is controlled as shown in the table below Table 2 Output Output 350mA Output 700mA Output 1A Al A2 KEY5 off LEDS off KEYS off LEDS off KEY5 on LED5 on KEY 1 off LED1 off KEY1 on LED1 on KEY1 on LEDI on or KEY5 on LED5 on KEY 1 off LED1 off B1 B2 KEY5 off LED5 off KEY5 off LEDS off KEY5 on LED5 on KEY 2 off LED2 off KEY2 on LED2 on KEY1 on LEDI on or 21 ee a a a ae www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators KEY5 on LED5 on KEY2 off LED2 off C1 C2 KEY5 off LED5 off KEY5 off LED5 off KEY5 on LEDS5 on KEY3 off LED3 off KEY3 on LED3 on KEY1 on LED1 on or KEY5 on LED5 on KEY3 off LED3 off D1 D2 KEYS off LEDS off KEY5 off LEDS off KEY5 on LEDS on KEY4 off LED4 off KEY4 on LED4 on KEY1 on LEDI1 on or KEY5 on LED5 on KEY4 off LED4 off Note The low power LED dimmer has four channels each channel is independent and with two independent outputs Although the two outputs are independent of each other for a channel they are controlled simultaneously If outputs of the dimmer connect excessive large current LED lightings this will lead to high heating value for the dimmer however when the temperatu
41. ned off completely by dimming In this case you can turn off the lights via switching 1 3 Dimming Controller 4fold 0 1 10V 0 1 10V DC control device with standard DC 0 1 10V control interface can be connected with electronic dimmable ballast EVG or other devices with 0 1 10V interface to control the lights such as dimming scenes switching and so on The 0 1 10V DC control device has embedded switching relays for 23 ECG 18W 14 ECG 36W 11 ECG 58W or 23 ECG T5 24W Each channel offers control voltage up to 23 electronic control gears ECG The devices adopt screw terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal There is no additional voltage input The following list provides a functional overview Switching the light Relative dimming Absolute dimming Status report Setting 15 scenes Staircase lighting function Preset value and modify preset value functions Bus recovery or reset function Switch relative dimming via manual buttons The above function of parameters to configure and use are described in the chapter 5 the device has own database file vd4 ADTV 04 16 1 And to set the output voltage type in the parameter according to the interface type of load as 0 10V or 1 10V There is an electronic manual operation function in the normal dimming mode but it is invalid in the staircase lighting mode Switch via a short operat
42. nels setting output current LEDS indicating output current of all channels increased by 350mA Output load terminals LEDs of indicating output status for each channel LED on meaning the channel has output or else no output LED1 LED4 indicating output current of a channel increased by 350mA Manual buttons switch via short operation relative dimming via long operation no telegram KEY1 KEY4 switch current button for a channel setting output current Input terminals input voltage 12 48V DC Manually set the output current is described as follows Switching current button for a channel set output current for the channel if the button KEY1 KEY4 is on the output current of the channel is increased by 350mA and its LED LED1 LED4 is on if the button is off the current is not increased and the LED is off Switching current button for all channels set output current for all channels if the button KEYS is on the output current of all channels are increased by 350mA and its LED LEDS is on if the button is off the current are not increased and the LED is off The button that set the output current is a dial switch when it is toggled down the button is on and the corresponding LED is also on when it is toggled up the button is off and the corresponding LED is also off The corresponding output dial switch and LED for each channel are as follows Table 1 Channel Output Switching current button I
43. ns Enable Disable It is able to send off command out by switch no matter in switch or permanent on mode with Enable but only stop outputting Permanent on by using permanent on to send OFF command in the permanent on lighting mode with Disable Note In the switch output mode it can start the permanent on output mode but can t be performed the close operation of permanent on when you did not start the the permanent on output mode 6 Communication Object Description Communication object is the media of devices on the bus communicate with other device that is just communication object can communicate with the BUS The role of each communication objects as following Take 1 fold universal dimmer for example 6 1 Communication object of Device General There are 2 communication objects in Device General in Fig 7 1 and functions are shown in table 7 1 43 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators N Name Object Function Description Group Add Length C R W T U Data Type Priority Ge Error report Report error of deivce 1 Byte C R T Low mi2 In operate In operate 1 bit G o m g E Low Fig 7 1 Communication object of Device General Note C in Flag column in the below table means that the object has a normal link to the bus W means the object
44. o the dimmer or load This manual provides the detailed technical information about various dimmers not only the installation and programming details but also the usage explanation in actual application 1 1 Universal Dimming Actuator The universal dimmers carry out dimming via phase modulation have Ichannel 2channels and 4channels each output of them is independent which can connect with dimmable lamps such as incandescent lamps HV halogen lamps LV halogen lamps with conventional or suitable electronic transformers dimmable energy saving www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators lamps and LED These lamps can be switched dimmed recall scene or other operations via the bus The device has an integrated short circuit and excess temperature protection The devices adopt screw terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal The input need connect a 230V AC operation voltage The following list provides a functional overview Switching the light Relative dimming Absolute dimming Status report error report Setting 15 scenes Staircase lighting function Bus recovery or reset function s A A re Preset value and modify preset value functions The above function of parameters to configure and use are described in the chapter 5 1 2 D
45. object can save current brightness status as new preset value It will save the current brightness value to brightness value at obj 0 with 0 that is to replace the is value It will save the current brightness value to brightness value at obj 1 with 1 that is to replace the is value 9 X preset 2 OUTPUT X 1lbit W C It is the communication object of preset 2 and calls the preset value When the object receives the logical value of 0 the brightness value of dimming are defined by Brightness value at obj 0 when the object receives the logical value of 1 the brightness value of dimming are defined by Brightness value at obj 1 This object will be started after activating preset 2 10 Set preset 2 OUTPUT X lbit W C This object is used to modify brightness value of preset 2 It will start the parameter preset 2 can be set via the bus with Enable Via this object can save current brightness status as new preset value It will save the current brightness value to brightness value at obj 0 with 0 that is to replace the is value It will save the current brightness value to brightness value at obj 1 with 1 that is to replace the is value Form7 4 Preset value function communication object 6 5 Staircase Lighting Function communication object of Dimming Actuator N Name Object Function Description Group Add Leng
46. ome small power dimmable LED lights These LEDs can be switched dimmed recall scene or other operations via the bus The devices adopt screw terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal The input need connect a 12V 48V DC operation voltage The following list provides a functional overview Switching the LED light Relative dimming Absolute dimming Status report error report Setting 15 scenes Staircase lighting function Bus recovery or reset function Preset value and modify preset value functions gt gt gt gt Set output current for per channel manually lt gt Switch relative dimming via manual buttons The above function of parameters to configure and use are described in the chapter 5 The database file vd2 7 piee E a O a a a a a SS a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators of the device is the same with KA D 0403 1 But the error report function is different the detail in section 4 9 5 2 Meanwhile there is added a manual operation function in the normal dimming mode it is invalid in the staircase lighting mode Switch via a short operation of manual buttons relative dimming via a long operation and in the case of the bus voltage fail the manual operation is invalid 1 5 LED Dimming Actuator 4fold 4A The dimmer
47. output load terminals 18 AT www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 Dimming Actuators GVS K BUS KNX EIB 3 3 Dimming controller 4fold 0 1 10V 3 3 1 ADTV 04 16 1 Dimension drawing 90 mm Connection Diagram L1 L1 L2 L2 L3 L3 N al Poe e SOT aeee a SEEI 1 10V DC 16A 250V mo Ti D Hi Mechanical manual operation Label carrier Programming button 19 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Red LED for entering the physical address green LED for application layer running normally bus connection terminal Electronical manual button LEDs of indicating output status for each channel LED on meaning the channel has output or else no output output load terminals 3 4 LED Dimming Actuator 4fold 350mA 3 4 1 KA D 04 L1 1 Dimension drawing Connection Diagram 20 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators EIB KNX bus connection terminal Programming button for assigning the physical address Red LED for entering the physical address green LED for application layer running normally KEY5 switch current button for all chan
48. ption is 1 64 field number or unallocated 39 SS a a CO a ns www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 5 5 4 Parameter Window X preset W 1 1 5 KA D 02 XX 1 din rail dimmer Device general A preset CH A general A dimming general A dimming A scene page A preset CH B general Active preset 1 via bus telegram Actived Brightness value is Dimming on Brightness value at obj 0 100 1 100 Brightness value at obj 1 100 1 7100 Preset 1 can be set via the bus Active preset 2 via bus telegram Deactive Fig 6 7 parameter window X preset It is able set the brightness value in X preset shown in Fig 6 7 There are two preset objects per output preset I and preset 2 which are used to realize the lighting control It is also able to save the current brightness status as the new preset value These 2 preset values have the same parameters setup so here take one as an example 6 Active preset 1 via bus telegram This parameter is used to activate preset 1 Options Active Deactive It will not activate the preset 1 with Deactive and show the following parameter with Active 6 Brightness value is This parameter defines the time when starting the dimming by preset 1 and there is 1 bit data to control X preset 1
49. q e a Guangzhou Video star Electronics Industrial Co Ltd Ela KNX 0 lt n K BUS Dimming Actuators User manual Ver 2 KA D 0103 1 KA D 0203 1 KA D 0403 1 KA D 04 T1 1 ADTV 04 16 1 KA D 04 L1 1 ADLD 04 03 1 KNX EIB Intelligent Installation Systems i EII ENR CE SS E E E E S E E A www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators Content 1 Introduction 77 777 777 2 2272 3 1 1 Universal Dimming Actuator 4 1 2 Dimming Controller 4fold 1 10V 5 1 3 Dimming Controller 4fold 0 1 10V 6 1 4 LED Dimming Actuator 4fold 350mA 7 1 5 LED Dimming Actuator 4fold 4A 8 2 Technical characteristic 2 202 02 0n nese nen nen n ene n ene nen nen nen nen neneneenennenes 9 2 1 Universal Dimming Actuator KA D xx03 1
50. ration and Button and red LED For assigning the physical address display Green LED flashing Indicate the application layer running normally LEDs for Output Indicate output status per channel LED on mean the channel has output LED off mean the channel has not output Manual buttons Switch via a short operation relative dimming via a long operation LED for a channel The LED on mean output current of the channel has increased by 350mA or else no increase Switch current button Set output current for a channel when switch on output current of for a channel the channels is added 350mA and its LED on or else no add LEDs for all channels The LED on mean output current of all channels have increased by 350mA or else no increase Switch current button Set output current for all channels when switch on output current for all channels of all channels is added 350mA and its LED on or else no add Type of protection IP 20 EN 60529 Temperature Operation 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Ambient Humidity lt 93 except dewing Mounting On 35mm DIN rail Dimension 90x72x64 2 mm Weight 0 3kg 13 www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 2 5 LED Dimming Actuator 4fold 4A ADLD 04 03 1 2 5 1 Technical data Power supply Output Connections Operation and display Type of protection Tempera
51. re detector of the dimmer detect certain heating value the dimming will regulate the output current thus will affect actual brightness value of LED lighting For example when the heating value exceeds 75 C the brightness value of LED will come down if the heating value continues to rise the brightness value will continue to fall The output is turned off in 90 C Therefore the load of the dimmer is limited as follows 1 Can connect two outputs of 1A 2 Can connect four outputs of 700mA 3 Can connect eight outputs of 350mA 4 The heating value of one output of 1A equivalent to the heating value of two outputs of 700mA 5 The heating value of one output of 700mA equivalent to the heating value of four outputs of 350mA According to five above the outputs can connect different loads in combination for example the dimmer can connect one output of 1A and two outputs of 700mA or two outputs of 700mA and six outputs of 350mA etc Seen from table 2 the connected load is impossible occur the combination of 350mA and IA and the current of two outputs of each channel is the same such as Al A2 When the rated current of the load is higher than the output current of the dimmer the brightness of load cannot reach Max value When the rated current of the load is lower than the output current of the dimmer the load will burn out 22 SS a CSO a a a a ay www video star com cn marketing video star com cn Tel 8620 39338986 Fax
52. s able to set a delay time changing time to dim UP the luminaries or dim UP gradually in the default period When receiving the OFF message the dimmer will be switched off immediately or dim DOWN gradually after a delay time changing time or in the default changing period 4 2 Relative dimming 4 data bits control the relative dimming command means it is possible to dim UP or DOWN to the needed brightness value during the set brightness threshold range It is only valid to dim UP when the brightness value is smaller than the low threshold value and dim DOWN when the brightness value is greater than the high threshold value It is also able to set whether to switch on the luminaries by the message dim UP to a certain value when the output is 0 by this function The relative dimming is used to control the relative changes of the brightness by 4 data bits the lowest 3 bits are controlling bit and the highest bit is 1 means dim UP 0 means dim DOWN Explanation of setting relative dimming 1 7 dim DOWN 0 8 remain unchanged stop dimming 9 15 dim UP Parameter 0 1 2 3 4 5 6 7 gt Unchange stop Dim DOWN 255 128 64 32 16 8 4 dimming Parameter 8 9 10 11 12 13 14 15 Unchange stop Dim UP 255 128 64 32 16 8 4 dimming 24 SS a Sa a ns www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BU
53. th C R W T U Data Type Priority mjo OUTPUT A Switch A 1 bit C s p s Low mjs OUTPUT A Permanent on 1 bit C Tt Low Fig 7 5 Staircase Lighting Function communication object No Function Object Name Data Type Flag 47 O a a E e S ae www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 0 Switch X OUTPUT X bit C W The communication object is used to switch the staircase light function of dimmer It will switch off the staircase lighting after a certain on time and the starting staircase lighting time are defined by Duration of staircase lighting Base and Duration of staircase lighting Factor and lights on duration is duration base factor It will be off automatically after some time It will switch off the lights with 0 5 Permanent on X OUTPUT X Ibit C W The object receives the logical value 1 to open staircase light for a long time receives the logical value 0 to end the staircase light Form 7 5 Staircase Lighting Function communication object 48 SS a www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465
54. ture Ambient Mounting Dimension Weight Operating voltage Input 4 channels Rated current Load voltage Safety EIB KNX Inputs outputs Button and red LED Green LED flashing LEDs for Output Manual buttons OT LED OV LED IP 20 EN 60 529 Operation Storage Transport Humidity On 35mm DIN rail 90x72x64 2 mm 0 3kg 21 30V DC via the EIB bus 12 24V DC 4A 12 24V DC constant voltage Short circuit over voltage and over temperature protection EIB bus connection terminal Using screw terminals For assigning the physical address Indicate the application layer running normally Indicate output status per channel LED on mean the channel has output LED off mean the channel has not output Switch via a short operation relative dimming via a long operation Indicate over temperature gt 70 C Indicate over voltage gt 26V DC 5 C 45 C 25 C 55 C 25 C 70 C lt 93 except dewing 3 Dimension and Connection Diagram 3 1 Universal Dimming Actuator 3 1 1 KA D 0103 1 Dimension drawing www video star com cn marketing video star com cn Tel 14 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 230V 50Hz 1 x 500 W VA Connection Diagram 230V 50Hz 1 x 500 W VA 3 1 2 KA D 0203 1 Dimension drawing 15 O a a a ee www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 G
55. value can be modified via the bus R means the value of the object can be read via the bus T means that a telegram is transmitted when the object value has been modified U means that value response telegrams are interpreted as a write command the value of the object is updated No Function Object Name Data Flags 12 In operate In operate l1bit C T This object is used to declare the working condition by sending 1 or 0 to the bus cyclically which is enabled when selecting send value 0 cyclically or send value 1 cyclically in the parameter Send object in operation and disabled when selecting no It will send 0 with option send value 0 cyclically and 1 with send value 1 cyclically 11 Report error of device Error report 1byte C R T This object is used to report the error status of the system It will be disabled with Error report and report error information when the system has the malfunction with the option Enable It will also send an alarm to switch off the device with over temperature overload or short circuit Assuming an 8 bit command telegram code as 76543210 Universal dimmer 8 bits are 0 that is the telegram 0 the system working normally No 0 is 1 Channel 1 short circuit or over load No 1 is 1 Channel 2 short circuit or over load No 2 is 1 Channel 3 short circuit or ov
56. ve dimming When it is greater than the high threshold it is not allowed to dim UP only to dim DOWN the range is 128 255 50 2 100 Supposing the high threshold is 200 if the current brightness value is greater than 200 it is not allowable to dim UP until dim DOWN to below than 200 If dimming down and value lt low dimming threhold output switch This parameter defines the action after relative dimming whether it will be off or stay in the low threshold value Options Off To low threshold value Supposing the low threshold is 50 If it is Off it will switch off the luminaries when dim DOWN to 50 if it is To low threshold value the value of the luminaries will remain the same even when dimming DOWN to 50 However no matter whether it is Off or To low threshold value if the low threshold of the relative dimming is smaller than that of the brightness it will switch off the luminaries automatically when dimming DOWN to the low threshold of the brightness value if the high threshold of the brightness is less than relative high threshold it is only possible to dim UP to the high threshold of the brightness The high and low threshold value will limit the total brightness value of the dimmer see more details in the below description Output switch on after receipt of dimming up telegram It tells that whether it is possible to switch on the luminaries when receiving the dimming up message
57. y the parameter setup in the brightness value dimming 45 O a E S S a E T www video star com cn marketing video star com cn Tel 8620 39338986 Fax 8620 39338465 GVS K BUS KNX EIB Dimming Actuators 2 Relative dimming X OUTPUT X 4bit W C This object is used to dim up or down the outputs It will dim down when the input value is from 1 to 7 During this range smaller amplitude of dimming down with larger value that means it will dim down to the biggest amplitude with 1 while to the smallest amplitude with 7 and 0 means stop dimming down It will dim up when the input value is from 9 15 During this range smaller amplitude of dimming up with larger value that means it will dim up to the biggest amplitude with 9 while to the smallest amplitude with 15 and 8 means stop dimming up Table 7 2 General communication object table for each channel 6 3 Scene function communication object of Dimming Actuator Length C R W T U Data Type Priority N Name Object Function Description Group Add 1 Byte E eas Low Eje OUTPUT A Scene save A Fig 7 3 Scene function communication object No Function Object name Data type Flag 6 Scene save X OUTPUT X 1Byte W C This object is used to send an 8bit command to transfer or save the scene This object is opening when on enable scene function The mean of 8bit as following Set up an 8bit command binary

Download Pdf Manuals

image

Related Search

Related Contents

Nokia 130 Bedienungsanleitung  取扱説明書 - 山田照明  owner`s manual manuale di istruzioni manuel d`utilisation  Installation & Maintenance Manual  FLOOR GRINDING & SURFACE PREPARATION  Powermate PM0476503.17 Parts list  Manuel d`instructions  GSV 形樹脂電磁弁  MANUAL DE INSTRUCCIONES  Fujitsu ESPRIMO E5730 E-Star4  