8401 User's Manual
Contents
1. configured to accommodate 110 VAC to 240 VAC The 100 VAC model does not have this configuration capability If your unit is a 100 VAC model simply connect your IEC line cord between the unit and your 100 VAC power lines and proceed to the paragraph marked Output in this section A standard IEC line cord supplied connects the unit to the power mains The IEC power entry module s fuse block is used to configure the operating voltage of the unit as either 115 VAC or 230 VAC Ensure the correct voltage setting is visible in the window of the power entry module before applying power to the unit If incorrect voltage is displayed or if fuses need to be installed follow the procedure below To install replace or check the fuses in the unit or to change the voltage setting of the unit The line cord must be removed from the IEC connector before attempting to open the cover 1 Open the fuse cover of the power entry module located on the rear panel of the 8491 SDI Remote Power Supply and extract the red fuse holder To accomplish this pry open the fuse cover using a small slotted head screw driver Insert the screwdriver into the notch on the end of the power entry module near the voltage window See pictures Page 3 www PressureSystems com Pressure Systems Inc 8491 User s Manual Figure 2 3 Preparing to Open the Fuse Cover Figure 2 4 Remove Fuse Block 2 Remove red fuse block from the power entry module Fuses of the sam
2. NANA oe e A e ee e a Don ue ul Ce Eee LL 0 2 3 5 Page 16 www PressureSystems com Pressure Systems Inc 8491 User s Manual Appendix D Load Test 12Vs 11 11 11 24 Ohms 6 Watt 12V 6 6 6 AA 12Vrin 15 15 15 2 12Vsrin S 12Vs 2 2 2 64 Ohms 2 5 Watt 12V 7 7 7 Y 12Vrin 5 5 5 12Vsrtn Sl 5Vds 13 13 13 5 Ohms 5Watt 5Vd 8 8 8 WAN 5Vartn 10 10 10 5Vdsrt dates n 4 4 4 N 5 Ohms 5 Watt 5Ve 3 2 3 BAN 5Verlin 9 9 9 Esrtn 14 14 14 NC 1 1 1 NC 12 12 12 Page 17 CABLE Serles restance of the cable shouK be between 0 3 and 6 Ohms LOAD Typkal bad approximating an SD wkh 4 DTC scanners Thk load and connecthg cable may be used for testing and calbrailhg the the 8491 Remote Power Supply when the operathg equipment b unavallable High resistance cables may be smukted wih sers reskstors Other bads may be substituted up to the specfjed current draw of each supply WARNING Remember to provide for the thermal bad h the cable as welas the test load Le 2 amps through 6 Ohms wii generate 24 watts of heat www PressureSystems com Measurement Specialties Inc 34 Research Drive Hampton VA 23666 USA Phone 757 865 1243 Toll Free 800 328 3665 Fax 757 865 8744 E mail sales PressureSystems com
3. Pressure Systems factory for any equipment not under warranty All products covered under warranty policy will be repaired at no charge An analysis fee will be charged to quote the cost of repairing any item not under warranty If for any reason the customer decides not to have the item repaired the analysis fee will still be charged If the quote is approved by the customer the analysis fee will be waived The quote for repair will be based on the factory s flat rate for repair calibration and board replacement When these prices do not apply the quote will be based on an hourly labor rate plus parts All replaced parts are warranted for 90 days from the date of shipment The 90 day warranty is strictly limited to parts replaced during the repair Pressure Systems Inc 8491 User s Manual Theory of Operation Introduction Remote pressure sensing inherently involves a separation of data sensing elements and data collection equipment Correct operation of the remote equipment is essential to overall system performance Ensuring that proper power is supplied to the sensing equipment is a major concern It is possible to supply excess power and regulate it at the sensing equipment However this imposes thermal loads and cabling requirements that can be detrimental to operation of the sensing equipment and to the systems under test The 8491 SDI Remote Power Supply fills the need to supply regulated power at the remote sensing equipment with re
4. Systems Inc Appendix A Input Standard Model Maximum Input Power Specifications 120 VAC configuration 120 VAC 10 50 60 Hz with a 3 amp time delay fuse 3AG 230 configuration 230 VAC 10 50 60 Hz with a 1 5 amp time delay fuse 3 AG 100 VAC Model 100 VAC 10 50 60 Hz with a 3 amp time delay fuse 3 AG 340 watts Maximum Regulated Output Current Environmental Operating temperature range Humidity Pressure Weight Dimensions External dimensions 12 2 amps at 12 volts 5 12 75 amps at 12 volts 5 Vd 1 5 amps at 5 volts 5 Ve 1 5 amps at 5 volts 5 0 to 50 C 0 to 95 relative humidity non condensing 1 atmosphere 5 15 19 1 kg 42 pounds 19 rack mountable 5U high space required 19 wide 483 0 mm 6 97 high 177 0 mm 17 11 deep 434 5 mm 1 50 38 1mm CLEARANCE FOR EKIT AIR FLOW H 17 56 446 0mm Remote Power SupplyTop View Page 8 www PressureSystems com Pressure Systems Inc 8491 User s Manual F 1 50 38 1mm CLEARANCE FOR INTAKE AIR FLOW ezl af enewaune Lad a muram El as TE 6 97 wv 101 A WU L A l N NIN ha 4 00 1 77 Omm 7 N vav z N 101 Bmm 18 31 465 0mm 19 02 483 0mm Remote Power Supply Front View Page 9 www PressureSystems com Pressure Systems Inc 8491 User s Manual Appendix B Cable Design 8411 09 28 HTD15P 09 28 HTD15P 09 38 1501 26 03 1422 0
5. and the unit may also be used outside a rack The 8491 SDI Remote Power Supply contains four independent isolated power supplies with individual remote sensing Front panel features aid installation and setup as well as providing monitoring capabilities See picture next page The front panel contains four analog current meters four separate circuit breakers a power switch and a digital voltage meter with a four position selector switch The output current of each power supply can be continuously monitored via the analog meters The output voltage of any of the four supplies can be checked with the digital panel meter by selecting the desired output with the four position selector switch Each output is protected by a circuit breaker The circuit breakers are reset from the front panel Page 1 www PressureSystems com Pressure Systems Inc 8491 User s Manual Analog Current Meters JE HN RRR 0 er ze 50 Digital E Meter 13 T uv LZ a LZ L 2 L ais 1 Power Switch Figure 2 1 Remote Power Supply Front Panel The power switch disconnects the unit from the power mains and is illuminated whenever power is applied The rear panel of the 8491 Remote Power Supply contains the IEC power entry module and two 2 output connectors WARNING The two output connectors may NOT be used simultaneously The 15 pin D sub miniature connector matches the power connector on the System 8400 SDI allowing fully re
6. 9 38 1501 12Vs 12Vs 12V 12Vrtn 12V 12Vrtn TT gt 1 O E ee E rr e ECO be Teron TT E EDO SAG S ER 5Vdrtn wW o5 04 03 o2 o1 01009 08 07 06 015014 013012011 SOLDER CUP VIEW The SDI Remote Power Supply cable consists of virtually any cable length presenting 6 ohms or less on any leg of seven 7 twisted pair wire terminated at each end with a male three row 15 pin D subminiature connector with a pin current rating of at least 2 amps The connector must be wired in accordance with the above diagram and Table 1 next page Wire length and size are governed by the overall path resistance Overall single signal path wire resistance between the SDI and the SDI Remote Power Supply must be 6 ohms or less Page 10 www PressureSystems com Pressure Systems Inc 8491 User s Manual Table B 1 Cable Wiring nes par ene 0 wame H R A GG TT A G e H EE sa coman A escena TA rss ocn FJ 2 nu J se o cian Page 11 www PressureSystems com Pressure Systems Inc 8491 Users Manual Table B 2 Pins to Twisted Pair No connection No connection Page 12 www PressureSystems com Pressure Systems Inc 8491 User s Manual Appendix C Cable Design Alternate Power Supply 8411 09 28 HTD15P 26 03 1422 09 38 DA9H 8491 09 49 15PW 12Vs 12Vs 12V 12Vrtn 12V 12Vrtn 5Ves 5Vesrtn 5Vds D Tr OOO A vine A m GX gt X ae a g h j k d C m 5Ve 5Vertn 5
7. Vd 5Vdrtn 05 0403020 O 01009 08 07 06 015014013012011 SOLDER CUP VIEW SOLDER CUP VIEW The SDI Remote Power Supply cable consists of any cable length between 20 feet and 300 feet nominally of 22AWG 7 twisted pair wire It is terminated on one end with a circular 15 pin connector to mate with the SDI Remote Power Supply output and a male three row 15 pin D sub miniature connector for the SDI on the other end The connectors are wired in accordance with the following diagram and table Wire length and size is governed by the overall path resistance Overall single signal path wire resistance between the SDI and the SDI Remote Power Supply must be less than 6 ohms Page 13 www PressureSystems com Pressure Systems Inc 8491 User s Manual Table C 1 Twisted Pair Order as ar Pres Poio COIE IN CTA SENERE ETC TE eee ae HHHH HHI een A e vom aane KUE 10 von svat TE PT pr oi Pe per coin Pe rer coin TR ts so crio Page 14 www PressureSystems com Pressure Systems Inc 8491 Users Manual Table C 2 Tabular form of wiring diagram ordered at circular connector Remote Power Supply Connector Pin a EC CIN ne ER e i Es ne e A o Page 15 www PressureSystems com Pressure Systems Inc 8491 User s Manual Table C 3 Tabular form of wiring diagram ordered at D Sub Remote Power Supply Connector Pin AR o o e IEC Ta e a TA e CENTRE e NA ANA me e Oe
8. asonably sized cables of useable lengths System Description There are currently four wire remote sensing power supplies available and commonly used to ensure proper voltage is available at the load However most commercial power supplies can only handle supply line impedance drops of one half volt This places severe restrictions on wire size cable length and current capacity For example with supply line impedance drops of one half a volt cable for a two amp 12 volt supply could not exceed one quarter ohm Q or approximately 23 feet of 20 AWG cable The 8491 SDI Remote Power Supply uses remote sensing to provide sufficient operating voltages to the System 8400 SDI Depending on loads the 8491 SDI Remote Power Supply will accommodate six ohms 60 of supply line impedance For example this will allow a fully populated SDI an SDI with sixteen ESP scanners to operate at the end of a 22 AWG cable over 340 feet long Alternately cables of mixed wire sizes can be used in order to maximize the flexibility of portions of the cable e g 270 feet of 22 AWG with 30 feet of 26 AWG for a 300 foot total length The 8491 SDI Remote Power Supply is a 19 inch rack mountable instrument that can be configured to operate on either 115 VAC or 230 VAC 50 60 Hz Input voltage may be changed by merely reversing the fuse insert in the power entry module and connecting the appropriate line cord See Section 2 2 Installation The case is fully enclosed
9. bles Re install the four 4 Phillips head screws and the procedure is complete Page 6 www PressureSystems com Pressure Systems Inc 8491 User s Manual Troubleshooting The 8491 SDI Remote Power Supply is a robust multiple output linear power supply Operation of the unit is essentially trouble free Most problems that arise will be due to poor or incorrect connections Ensure the sense lines are properly connected to the correct delivered voltages at the load and that the connections are contiguous back into the unit The high density 15 pin connectors are reliable when properly installed and secured but can be damaged during improper handling The connectors should never be probed Probing the connectors with wires or test leads will damage the sockets and degrade their current carrying capability This may cause intermittent connections or prevent them from making any contact Check for bent broken missing or recessed pins Crushed or damaged cables are also a source of problems with remote sensing equipment Look for damage near the connectors where the cable passes through a bulkhead or anywhere the cable may be exposed to traffic The cables and connectors should be repaired or replaced as necessary See Appendix B and C Cable Design for correct cable wiring diagram If the problem persists contact Pressure Systems Inc for assistance 1 800 678 SCAN Page 7 www PressureSystems com 8491 User s Manual Pressure
10. e amperage are placed in both sides of the red fuse block Note that the fuse block is marked with 115V and 230V and can be inserted in two orientations Choose the orientation where the appropriate voltage will be visible through the window on the cover when the cover is closed Page 4 www PressureSystems com Pressure Systems Inc 8491 User s Manual Figure 2 5 Fuse Block Orientation 3 Reinsert the red fuse block into the power entry module Once the fuse block is in place and the cover snap closed the line cord may be reinstalled and the unit is then ready to accept appropriate input power NOTE 3 amp fuses are used with 120 VAC units and 1 5 amp fuses are used with 230 VAC units See Appendix A Specifications Output The output power cable connects the 8491 SDI Remote Power Supply to the SDI Sense line connections are internal to the SDI With this cable and the line cord connected the unit is ready to operate Push the power switch to latch it and the unit is ON Currents can be monitored on the front panel meters The supply can safely operate with no load An SDI with no scanners will draw approximately 0 9 amps on the 5 volt digital supply Output voltages can be monitored by depressing the voltage selection switch corresponding to the voltage to be monitored External voltage measurements must be done at the load Non SDI loads i e test or calibration loads must supply the sense line connections internal to the SDI See Ap
11. measurement SPECIALTIES dg 0 PRESSURE SYSTEMS e o 8401 User s Manual July 2000 www PressureSystems com Our Publication Disclaimer This document is thoroughly edited and is believed to be thoroughly reliable Pressure Systems assumes no liability for inaccuracies All computer programs supplied with your products are written and tested on available systems at the factory Pressure Systems assumes no responsibility for other computers languages or operating systems Pressure Systems reserves the right to change the specifications without notice Our Company Pressure Systems develops manufactures and services level and pressure measuring instruments where the highest level of traceable accuracy is required for aerospace industrial municipal and environmental applications Our products have become the world standard for electronic level and pressure measurement and scanning We are committed to the highest quality design manufacture and support of level and pressure instrumentation that is in the best interest of our customers Pressure Systems is an 1509001 2000 certified company Our Warranty Pressure Systems warrants this ESP Pressure Scanner product to be free of defects in material and workmanship under normal use and service for one 1 year from date of shipment Merchandise Return Procedures If your system seems to be in good working order but the data seem abnormal contact the Applications Support Group at Pres
12. pendix C Test Load Calibration The 8491 Remote Power Supply comes preset from the factory and in normal use should not require any field adjustments Identical post regulator boards are used for each supply and are interchangeable Adjustment is normally not required if a post regulator board previously calibrated for one voltage is exchanged for a board in a matching voltage range i e a 12 volt to a 12 volt position or a 5 volt to a 5 volt position However if the post regulator boards are moved from one voltage range to another the output will require adjustment There are two adjustment potentiometers on each post regulator board R11 adjusts the output voltage while R8 affects the load regulation User adjustment of the R8 potentiometer is normally not required and is not recommended R8 is sealed at the factory Page 5 www PressureSystems com Pressure Systems Inc 8491 User s Manual Figure 2 6 Adjustment of Potentiometers The output voltage may be adjusted with the following procedure however the unit must be opened to perform make the adjustment This is NOT considered a part of normal operations The procedure must be performed by a qualified technician familiar with power supply maintenance and the safety procedures associated with working on open electrical equipment Tools required Phillips head and small slotted head screwdrivers 1 Remove the four 4 Phillips head screws in the front panel and gently
13. pull the panel forward being careful not to disconnect any of the connecting wires 2 The post regulator sub rack is now accessible with the ends of the four post regulator boards isible The voltage adjustment potentiometer R11 is positioned midway up each post regulator board It is mounted at a right angle to the printed circuit board PCB and is directly accessible from the front of the unit Matching the front panel markings from left to right the post regulators control the 12 volts the 12 volts the 5 volt logic supply and the 5 volt excitation supply Locate the appropriate PCB and associated R11 for the output voltage requiring adjustment See picture below 3 The voltage supply may be monitored by using the front panel voltage selector switch four position switch and the front panel digital voltage meter Some manipulation of the front panel or the use of a mirror may be required to view the meter Alternatively an external meter may be used An appropriate load with proper sense line connections must be in place Use normal operating load or see Appendix C Any external meter must be connected at the load With a slotted head screwdriver adjust the R11 corresponding to the supply being monitored setting the delivered voltage R11 should provide a minimum adjustment range of 5 from nominal 4 Other post regulators may be adjusted in a similar manner 5 Replace the front panel taking care not to pinch any of the ca
14. sure Systems The staff is available for troubleshooting at 757 865 1243 or toll free at 1 800 678 7226 SCAN during normal working hours Eastern time If the entire system or any part must be returned to Pressure Systems please obtain a Returned Merchandise Authorization RMA from the Customer Service Department Be prepared to supply the following information when requesting the RMA Part number Serial number Complete description of problems symptoms Bill To and Ship To address Evaluation repair purchase order number not required for warranty repairs Customer contact and telephone number The above information including the RMA number must be on the customer s shipping documents that accompany the equipment to be repaired Pressure Systems also requests that the outside of the shipping container be labeled with the RMA number to assist in tracking the repairs All equipment should be sent to the following address ATTN CUSTOMER SERVICE 7 digit RMA number Pressure Systems Inc 34 Research Drive Hampton Virginia 23666 Pressure Systems will return North American warranty items prepaid via UPS GROUND Overseas warranty items will be returned via AIR FREIGHT If the customer desires another method of return shipment Pressure Systems will prepay and add the shipping charges to the repair bill Incoming freight charges are the customer s responsibility The customer is also responsible for paying shipping charges to and from the
15. versible one to one cables to be used The 15 pin circular connector is provided for installations desiring a more physically robust back panel connector A blocking plate is attached covering one of the two connectors This plate must be moved to switch to the type of output connector desired Slots are provided so that the plate can be moved without its having to be detached Simultaneous use of both output connectors will force incorrect voltages into attached equipment with the potential for catastrophic equipment damage See warning above A significant portion of the rear panel is covered with cooling air vents Airflow is into the top of the unit through two 2 filtered cooling fans Air exits through the vents in the rear panel A minimum clearance of 1 5 inches is required over the fan filters and behind the rear panel exit vents Page 2 www PressureSystems com Pressure Systems Inc 8491 User s Manual Figure 2 3 Figure 2 2 D Shell Connector Remote Power Supply Rear Panel Installation The 8491 SDI Remote Power Supply may be operated from a bench top or installed in a 19 inch rack The 8491 SDI Remote Power Supply is heavy 19 1 kg and when installed in a rack all four panel bolts must be in place and threads on the attaching bolts must be fully engaged Input Two models of the 8491 SDI Remote Power Supply are available to accommodate international voltages The following paragraphs describe how the standard model may be
Download Pdf Manuals
Related Search
Related Contents
Manual de Utilização da Ferramenta para a Gestão de Allen-Bradley OS-9 Assembler-Linker Manual de Instruções Documentation spécifique du programme ACCESSOIRES - Physio Control 576 Manual - Barry Rudolph Student User Manual Sharp YO-P5A Owner's Manual Web Server 3.0 User Manual Copyright © All rights reserved.