bdiPro Installation Manual

image

Contents

1. ere rnnt nno p inte cuu oie ex e anno tha Peso eR x IIa Dre ER ena 15 6 Abatron Warranty and Support Terms eeeeeseeeeseseseeeee ener nien nnn nnnm nnn n nn 16 Gel EIC M 16 6 2 cien lE 16 6 3 Warranty and Disclaimer ose o sies Dei RD aset REN D ebrei Ras Dad dde potu udis etas 16 6 4 Limitation of Liability s uio E core e Idae boxed oo i ORTUS Eve een eee 16 Appendices A Troubleshiootilhg aaa aaa c cere Eee Tee cweveceseternuednesscurcvciiesuscecnectuesstceedpectenssnsevere 17 IA EIL E 17 NERO DIDI CH statis the cws eck activate A A 17 Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 3 1 Introduction Target System Target System JTAG Interface PC Host Abatron AGSwiss Madi Se RS232 Ethernet 10 100 BASE T JTAG Interface Abatron AGSwiss Mal fs bdiPro is a powerful software package allowing on board programming with the BDI3000 from Abatron bdiPro eliminates the inefficient individual chip programming particularly for surface mounted designs The unprogrammed memories can be soldered to the printed circuit board and programmed simultaneously on a just in time basis 1 1 BDI3000 The BDI3000 is the main part of the bdiPro system This small box implements t
2. 9 600 19 200 38 400 57 600 115 200 8 none 1 10 100 BASE T up to 32 MHz 1 2 5 0 V 5 C 60 C 20 C 65 C lt 90 rF 160 x 85 x 35 mm 280 g 25m CE compliant RoHS 2002 95 EC compliant Specifications subject to change without notice Copyright 1993 2011 by ABATRON AG V 1 01 e Ax for BDI3000 MIPS32 User Manual 15 4 Environmental notice Disposal of the equipment must be carried out at a designated disposal site 5 Declaration of Conformity CE DECLARATION OF CONFORMITY This declaration is valid for following product Type of device BDM JTAG Interface Product name BDI3000 The signing authorities state that the above mentioned equipment meets the requirements for emission and immunity according to EMC Directive 89 336 EEC The evaluation procedure of conformity was assured according to the following standards IEC 61000 6 2 1999 mod EN61000 6 2 2001 IEC 61000 6 3 1996 mod EN61000 6 2 2001 This declaration of conformity is based on the test report no E1087 05 7a of Quinel Zug Swiss Testing Service accreditation no STS 037 Manufacturer ABATRON AG Lettenstrasse 9 CH 6343 Rotkreuz Authority Goce EU Max Vock Ruedi Dummermuth Marketing Director Technical Director Rotkreuz 7 18 2007 Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 16 6 Abatron Warranty and Support Ter
3. TRGT marked light up when target is powered up 14 VIO Target 24 GROUND For BDI TARGET A connector signals see table on next page Warning Before you can use the BDI3000 with an other target processor type e g MIPS lt gt ARM a new setup has to be done see chapter 2 5 During this process the target cable must be disconnected from the target system To avoid data line conflicts the BDI3000 must be disconnected from the target system while programming a new firmware for an other target CPU Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 6 BDI MAIN TARGET A Connector Signals Describtion EJTAG Debug Interrupt EJTAG 2 5 This output of the BDI3000 connects to the target DINT line RC32300 This output of the BDI3000 connects to the target DebugBoot line TRST EJTAG Test Reset This output of the BDI3000 resets the JTAG TAP controller on the target GND System Ground TCK EJTAG Test Clock This output of the BDI3000 connects to the target TCK line TMS EJTAG Test Mode Select This output of the BDI3000 connects to the target TMS line RESET This open collector output of the BDI3000 is used to reset the target system TDI EJTAG Test Data In This output of the BDI3000 connects to the target TDI line VIO Target 1 2 5 0V This is the target reference voltage It indicates that the target has power and it is also
4. User configurable program sequences for target system initialization clock chip select If required you can write special routines that runs before or after the program erase process pre programming post programming pre erase post erase Information about menus and dialog boxes by pressing the F1 function key O Copyright 1993 2011 by ABATRON AG V 1 01 e Ax for BDI3000 MIPS32 User Manual 5 2 Installation 2 1 Connecting the BDI3000 to Target The cables to the target system are designed for the IDT RC32300 Development Boards optional available Part 90070 and for EJTAG 2 5 compatible boards enclosed In case where the target system has the same connector layout the cable 14 pin or 24 pin can be directly connected A In order to ensure reliable operation of the BDI EMC runtimes etc the target cable length must not exceed 25 cm 10 24 pin RC32300 Connector 1 TRST Target System gt e000eeeeee 2 GROUND VSS SESS ce SELLS gt optional 5 Eu 4 available 6 GROUND VERRE P N 90070 7 TMS icd 14pin EJTAG 8 GROUND 2 Key 44 Connector 40 GROUND 1 TRST 11 RESET BDI3000 12 GROUND 3 TDI 14 GROUND 5 TDO TARGET A 6 GROUND 16 GROUND 7 TMS 8 GROUND 18 GROUND 9 TCK 20 GROUND 11 RESET 21 DBGBOOT 22 GROUND 13 DINT 23 VIO Target The green LED
5. data link is successful between the UTP port of the BDI3000 and the hub to which it is connected The LED blinks when the BDI3000 is receiving or transmitting data When this LED light is ON 100Mb s mode is selected default When this LED light is OFF 10Mb s mode is selected Copyright 1993 2011 by ABATRON AG vV 1 01 e A for BDI3000 MIPS32 User Manual 11 2 5 Installation of the bdiPro Software On the enclosed CD you will find the bdiPro software and the firmware required for the BDI Copy all the files to a directory on your harddisk The following files are on the CD b30pgr4k exe bdiPro program b30pgr4k chm Helpfile for bdiPro program b30r4kfw xxx Firmware for BDI3000 for MIPS32 targets bdiifc32 dll BDI Interface DLL XXXXXX Pro Predefined Program sets Installing BDI Pro Create a new directory on your harddisk for example C BDIPRO Copy the entire contents of the enclosed CD into this directory 2 6 Configuration Before you can use the full functionality of the bdiPro software you must configure the system correctly The Setup Menu enables you to perform the following configuration tasks e Set the correct communication parameters gt Communication between the PC and the BDI Load or update the firmware logic gt Firmware Configure the target system memory type gt Target Memory and memory organization Program the initialization routines for the gt Target I
6. Liability IN NO EVENT SHALL ABATRON OR ITS SUPPLIERS BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING WITHOUT LIMITATION ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE HARDWARE AND OR SOFTWARE INCLUDING WITHOUT LIMITATION LOSS OF PROFITS BUSINESS DATA GOODWILL OR ANTICIPATED SAVINGS EVEN IF ADVISED OF THE POSSIBILITY OF THOSE DAMAGES The hardware and software product with all its parts copyrights and any other rights remain in pos session of ABATRON Any dispute which may arise in connection with the present agreement shall be submitted to Swiss Law in the Court of Zug Switzerland to which both parties hereby assign com petence Copyright 1993 2011 by ABATRON AG vV 1 01 e AR for BDI3000 MIPS32 User Manual 17 Appendices A Troubleshooting Problem The firmware can not be loaded Possible reasons e The BDI is not correctly connected with the Host see chapter 2 A wrong communication port is selected Com 1 Com 4 The BDI is not powered up Problem No working with the target system loading firmware is okay Possible reasons Wrong pin assignment BDM JTAG connector of the target system see chapter 2 Target system initialization is not correctly enter an appropriate target initialization list An incorrect IP address was entered BDI3000 configuration BDM JTAG signals from the target system are not correctl
7. ed during this setup session Speed Select the baudrate used to communicate with the BDI3000 loader during this setup session Connect Click on this button to establish a connection with the BDI3000 loader Once connected the BDI3000 remains in loader mode until it is restarted or this dialog box is closed Current Press this button to read back the current loaded BDI3000 firmware ver sion The current firmware version will be displayed Erase Press this button to erase the current loaded firmware Copyright 1993 2011 by ABATRON AG V 1 01 e Ax for BDI3000 MIPS32 User Manual 13 Update This button is only active if there is a newer firmware version present in the execution directory of the setup software Press this button to write the new firmware into the BDI3000 flash memory BDI IP Address Enter the IP address for the BDI3000 Use the following format XXX XXX XXX xXxx e g 151 120 25 101 Ask your network administrator for assigning an IP address to this BDI3000 Every BDI3000 in your network needs a different IP address Subnet Mask Enter the subnet mask of the network where the BDI is connected to Use the following format xxx Xxx xxx xxxe g 255 255 255 0 A subnet mask of 255 255 255 255 disables the gateway feature Ask your network administrator for the correct subnet mask Default Gateway Enter the IP address of the default gateway Ask your network administra tor for the correct gateway IP address If
8. he interface between the BDM JTAG pins of the target processor and a 10 100Base T Ethernet or RS232 connector The firmware of the BDI3000 can be updated by the user with a simple Windows based configuration pro gram The BDI3000 supports 1 2 5 0 Volts target systems Copyright 1993 2011 by ABATRON AG vV 1 01 ldi for BDI3000 MIPS32 User Manual 4 1 2 Functions The bdiPro software provides the following functions File Edit Target Setup Help Load Save Print Print Preview Print Setup Print Comment Load Store Dump Edit Clear Fill Checksum Erase Program Verify Communication Firmware Target Memory Target Initlists e Save and recall user defined program sets Print the active program set Display the active program set on the screen Select the printer and the printer connection Edit the headers and comment Load the program file Binary Motorola S Record and Intel hex Store the local memory image in S Record format Load the target system data into local memory Edit the local memory image Clear the local memory image Fill a local memory area with pattern Calculation of checksum Erase the target memory all sectors Program the target memory Compare the target system memory with local memory Communication setup between the PC and the BDI Load and verify the firmware Target memory setup memory type and memory organisation
9. ldi for MIP 22 Installation Manual Manual Version 1 01 for BDI3000 abatr on 1993 2011 by Abatron AG e Ax for BDI3000 MIPS32 User Manual 2 1 Drieepdipm 3 dd BDISO0D ohio ite eiat oth embodied dee oir eE br dens dep eaataugaglagacuiotedimedcensncits 3 1 2 Eunctions a eie oet t ER ER EXER NUR ERE E EER EO EC BOR EXU EXER RUF TEE Ee d axe Pre E Rak rA MeS 4 ZA MASTANATION MESE 5 2 1 Connecting the BDI3000 to Target essssesseseeeeeeeneenne nennen rennen nnne 5 2 2 Connecting the BDI3000 to Power Supply seeseeeeeee eene 7 23 Status LED Op T 8 2 4 Connecting the BDI3000 to Host sessesssseseeseseeeneeneeee nennen enne nne nnne nne 9 2 4 1 Seral line cormb uhicatiofts esee ovid orabat ls on REEL M dua RR GA EUNDO UTE rS Dude 9 2 4 2 Ethernet communication sssssssssee e eee 10 2 5 Installation of the bdiPro Software sssessssssesessseseeeeeenene enne 11 2 6 EJA TRENN ONA s osos tis pt pieta ipia tem ti ees tec A 11 2 6 1 BDIS000 Setup WO AS us cerne pde Roca Po Descente pa ee e Cnt vete i HABE aa OUS Md cud ar adu 12 3 Specificallalis eoi oce tendi ice toto euius ete RS Le Cute ret 14 A Environmental notlCe 1 e aa ccce rire error rina Ee pan ku FAN ER YR YER TER RR S EE R A RR EVER R SERE R P ARE aaa EEANN 15 5 Declaration of Conformity CE
10. lready loaded The output voltage from the power supply is too low The BDI loader mode is active an invalid firmware is loaded or loading firmware is active Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 9 2 4 Connecting the BDI3000 to Host 2 4 1 Serial line communication The host is connected to the BDI through the serial interface COM1 COM4 The communication cable included between BDI and Host is a serial cable There is the same connector pinout for the BDI and for the Host side Refer to Figure below Target System 5 GROUND BDIso00 RS232 Connector for PC host 2 RXD data from host 3 TXD data to host PC Host RS232 Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 10 2 4 2 Ethernet communication The BDI3000 has a built in 10 100 BASE T Ethernet interface see figure below Connect an UTP Unshielded Twisted Pair cable to the BD3000 Contact your network administrator if you have ques tions about the network 10 100 BASE T 1 8 Connector 1 TD 2 TD 3 RD LED1 LED2 6 RD BDIs000 mem The following explains the meanings of the built in LED lights Target System Ethernet 10 100 BASE T k Function Description Link Activity When this LED light is ON
11. ms 6 1 Hardware ABATRON Switzerland warrants that the Hardware shall be free from defects in material and work manship for a period of 3 years following the date of purchase when used under normal conditions Failure in handling which leads to defects or any self made repair attempts are not covered under this warranty In the event of notification within the warranty period of defects in material or workman ship ABATRON will repair or replace the defective hardware The customer must contact the distrib utor or Abatron for a RMA number prior to returning 6 2 Software License Against payment of a license fee the client receives a usage license for this software product which is not exclusive and cannot be transferred Copies The client is entitled to make copies according to the number of licenses purchased Copies exceeding this number are allowed for storage purposes as a replacement for defective storage mediums Update and Support The agreement includes free software maintenance update and support for one year from date of purchase After this period the client may purchase software maintenance for an additional year 6 3 Warranty and Disclaimer ABATRON AND ITS SUPPLIERS HEREBY DISCLAIMS AND EXCLUDES TO THE EXTENT PERMITTED BY APPLICABLE LAW ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT 6 4 Limitation of
12. nitlists target system Any time you need information about specific menus and dialog boxes you can display the integrated Help screens by pressing the F1 function key The Edit and Target menus will only become active when you have specified a memory type see Target Memory in the Setup Menu Copyright 1993 2011 by ABATRON AG vV 1 01 ldi for BDI3000 MIPS32 User Manual 12 2 6 1 BDI3000 Setup Update First make sure that the BDI is properly connected see Chapter 2 1 to 2 4 The BDI must be con nected via RS232 to the Windows host A To avoid data line conflicts the BDI3000 must be disconnected from the target system while programming the firmware for an other target CPU family The following dialogbox is used to check or update the BDI firmware and to set the network param eters iim BDI3000 Update Setup r Connect BDI3000 Loader Channel SN 30000133 Port NETWORK MAC 000001300001 Speed 5600 el Version 1 00 m BDI3000 Firmware Loaded Version 1 08 Newest Version 1 09 Current Erase Update r Configuration BDI IP Address 5112025100 Subnet Mask 255 255 2550 Default Gateway 255 255 255 255 Cancel Ok Writing setup data passed dialog box BDI3000 Update Setup The following options allow you to update the BDI3000 firmware and store the network parameters Port Select the communication port where the BDI3000 is connect
13. the gateway feature is disabled you may enter 255 255 255 255 or any other value Transmit Click on this button to store the configuration in the BDI3000 flash memory Default IP 192 168 53 72 Before the BDI is configured the first time it has a default IP of 192 168 53 72 that allows an initial configuration via Ethernet If your host is not able to connect to this default IP then the initial config uration has to be done via the serial connection Note If there is currently a firmware loaded setup via the Network channel is only possible if the BDI3000 is already in Loader mode Mode LED blinking To force Loader mode enter boot loader at the Telnet The setup tool tries first to establish a connection to the Loader via the IP address present in the BDI IP Address entry field If there is no connection established after a time out it tries to con nect to the default IP 192 168 53 72 Copyright 1993 2011 by ABATRON AG vV 1 01 e A for BDI3000 MIPS32 User Manual 14 3 Specifications Operating Voltage Limiting Power Supply Current RS232 Interface Baud Rates Data Bits Parity Bits Stop Bits Network Interface BDM JTAG clock Supported target voltage Operating Temperature Storage Temperature Relative Humidity noncondensing Size Weight without cables Host Cable length RS232 Electromagnetic Compatibility Restriction of Hazardous Substances 5 VDC 0 25 V typ 500mA max 1000 mA
14. used to create the logic level reference for the input comparators It also controls the output logic levels to the target It is normally fed from Vdd I O on the target board EJTAG Test Data Out This input to the BDI3000 connects to the target TDO line Copyright 1993 2011 by ABATRON AG vV 1 01 e Ax for BDI3000 MIPS32 User Manual 7 2 2 Connecting the BDI3000 to Power Supply The BDI3000 needs to be supplied with the enclosed power supply from Abatron 5VDC A Before use check if the mains voltage is in accordance with the input voltage printed on power supply Make sure that while operating the power supply is not covered up and not situated near a heater or in direct sun light Dry location use only A For error free operation the power supply to the BDI3000 must be between 4 75V and 5 25V DC The maximal tolerable supply voltage is 5 25 VDC Any higher voltage or a wrong polarity might destroy the electronics 1 casing connected to ground terminal The green LED BDI marked light up when 5V power is connected to the BDI3000 Please switch on the system in the following sequence e 1 external power supply 2 target system Copyright 1993 2011 by ABATRON AG V 1 01 e Ax for BDI3000 MIPS32 User Manual 8 2 3 Status LED MODE The built in LED indicates the following BDI states MODE LED BDI STATES The BDI is ready for use the firmware is a
15. y short circuit break The target system is damaged Problem Network processes do not function loading the firmware was successful Possible reasons The BDI3000 is not connected or not correctly connected to the network LAN cable or media converter An incorrect IP address was entered BDI3000 configuration B Maintenance The BDI needs no special maintenance Clean the housing with a mild detergent only Solvents such as gasoline may damage it C Trademarks All trademarks are property of their respective holders Copyright 1993 2011 by ABATRON AG vV 1 01