USER MANUAL MATCH 19" 700-1500 UPS

image

Contents

1. ey 1 3 Transport Storage e No liability can be accepted for any transport damage when the equipment is shipped in non original packaging e During transport the battery drawer must either be removed or fixed with two screws at the rear side of the UPS A fig 1 e Store the UPS in a dry location with the batteries in a fully charged state Storage temperature must be within 20 45 C If the unit is stored for a period exceeding 3 months optimal battery lifetime is obtained if the storage temperature does not exceed 25 C e If the unit is stored for an extended period of time the batteries must be recharged periodically Be sure that the battery drawer is connected to the UPS Subsequently connect the unit to a wall outlet and recharge the batteries for 24 hours if the storage temperature is within 20 and 30 C every 3 months if the storage temperature is within 20 and 45 C every month 2 Installation The shipping box contains a Match 19 UPS two IEC male female power cords a data cable a CD ROM and this manual After unpacking inspect the UPS for damage If you find any damage please immediately notify the carrier and place of purchase IMPORTANT Before making any connection and switching on the UPS please check the following conditions your mains supply is 220 240 Volts and 50 or 60 Hz and e the total power demand of the connected equipment does not exceed the rated output power of the UPS
2. Power factor Transfer time Buck Boost voltage regulation Batteries ratings given for 25 C Nominal voltage Vdc Number x capacity Ah of batteries Type Service life Recharge current Battery recharge time for 90 capacity hours approximation Runtime in minutes at typical load 75 VA Watts 100 60 300 180 500 300 700 420 1000 600 1500 900 General Weight without battery drawers kg Weight with battery drawers kg Dimensions hxwxd mm Depth required in 19 rack mm Enclosure protection Environment Safety Electromagnetic compatibility Ambient temperature Sound at 1 meter Maximum relative humidity OPM_MAE_19X_700_1K5_2GB_V030 700 1000 1500 700 1000 1500 420 600 900 220 240 V 165 275 V mains operation 350V above 275V battery operation 187 V at any load 50 Hz or 60 Hz nominal 2 5 Hz typically 7W 700 or 12W 1000 1500 4 0 6 0 8 0 5 10 10 230 V suitable for 220 240 V loads nominal 2 battery operation RMS value 50Hz or 60Hz autosensing last detected frequency off factory 50 Hz lt 0 1Hz battery operation sine wave 0 6 0 7 at 90 load typical 4 ms at 165 275 V input voltage output voltage 190 254V 24 36 36 2x7 3x7 3x12 12V sealed lead acid maintenance free up to 6 years depending on use 3A 2 2 2 12 13 16 84 120 190 26 41 70 13 23 41 8 15 30 8 20 10 14 15 15 19 22 26 133 5 SHU x 450 19 x 440 420 w
3. alarm 8 fig 6 blinks as E gt 75 well T gt 50 E gt 25 3 2 3 Auto off no load shutdown B gt 5 If this function is activated the UPS will switch off during a mains failure when the load is less than 5 of the maximum load In this way unnecessary discharging of the batteries is avoided The unit will automatically turn on again when mains power is restored The default setting of the no load shutdown function is activated You can change this setting through the RS232 port using the UPS configuration tool that came with the unit CD ROM see 5 4 Please note that if the UPS is not connected to the mains and the batteries are disconnected from the UPS the unit will return to the default setting 2 4 Battery test During normal operation press keypad l for one second The duration of the test is 4 seconds See also 3 3 6 2 5 Switching off Press keypad 0 14 fig 6 briefly If electric isolation is required unplug the power cord from the wall outlet OPM_MAE_19X_700_1K5_2GB_V030 4 GE DE Match 19 700 1500 User manual 3 0 GB 3 3 Use Status and Alarm Indications o status indications l low priority alarms I high priority alarms the operating mode GE Digital Energy abnormal operating situations guaranteed immediate action should be taken situations in which the actual output voltage of the UPS is no longer fig 6 GE Digital Energy O pe on alarm 9 e avr l prog
4. 2 hours It is acceptable to use the UPS without first charging the battery but the runtime may be reduced 8 For advanced communication possibilities the RS232 interface port 3 fig 1 can be connected to a computer system and or optional interface cards 5 fig 1 1000 1500VA models only can be added See chapter 4 OPM_MAE_19X_700_1K5_2GB_V030 3 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 3 Operation Please refer to figure 6 3 1 Start up 3 1 1 Start up mains available 1 Press keypad l 13 fig 6 briefly LED on already blinking will illuminate continuously now 2 The equipment connected to the UPS can now be switched on 3 1 2 Start up mains not available If the mains input is absent power cord not connected or mains failure 1 Press keypad l briefly and then 2 Press keypad l during 5 seconds until the buzzer sounds The LEDs on and on battery 12 fig 6 will illuminate The UPS operates on battery it discharges the batteries 3 2 Use Normal Operation 3 2 1 Normal operation conditions e the mains supply is present e the UPS is on e the load does not exceed the capacity of the UPS and e the operating temperature is below alarm level fig 5 3 2 2 Load indication fig 5 1 During normal operation press keypad l briefly A 2 Yellow LEDs will blink during 3 seconds the number is load Y E gt 100 dependent in case of overload LED
5. 3 5 Battery low 3 3 6 Replace battery 3 3 7 Overload 3 3 8 High temperature 3 3 9 Programmed shutdown 4 COMMUNICATION E 7 4 1 RS232 Port 4 2 Relay Interface Card option 4 3 SNMP Interface Card option 5 MAINITENANGE isian a a a aaa aa aaa AA aaia 7 5 1 General 5 2 Fuses 5 3 Batteries 5 3 1 General 5 3 2 Battery replacement 5 4 UPS Configuration Tool 6 TROUBLESHOOTING vnrisinnnennnenunn a a a as 9 7 SPECIFICA TIONS ssessessesesrsserseerrsrerusrurusrnrasrnratustaruseerustnrucuutatnntatuentusterucenraennnann 10 GE Digital Energy All rights reserved reproduction without permission prohibited This manual may be subject to change no liability can be accepted for any error or omission OPM_MAE_19X_700_1K5_2GB_V030 1 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 1 Introduction 1 1 Introduction The General Electric GE Digital Energy Match 19 UPS an uninterruptible power supply protects your equipment from all forms of power interference including complete power failures 1 2 Safety Rules CAUTION RISK OF ELECTRICAL SHOCK The UPS contains batteries The appliance outlets may be electrically live even when the UPS is disconnected from the mains 5 The UPS contains potentially hazardous voltages Do not open the UPS there are no user serviceable parts inside A All maintenance and service work except for replacement of the batteries should be performed A by qualified service personnel
6. given by the computer manual restart required e ifthe load is lt 5 and the auto off function is activated see 3 2 3 Runtime indication fig 7 During battery operation press keypad l briefly The 4 yellow LEDs indicate during 3 seconds the remaining runtime time for the WC go actual load HB gt 20min E gt 10min Battery low end of runtime E gt 5min The batteries are nearly discharged Controlled shutdown of your E gt 2mn computer equipment should be completed within 1 minute fig 7 Replace battery The batteries are bad The alarm only goes out after the next battery test if the batteries have either been sufficiently charged discharged batteries or replaced by a new set worn out batteries Overload The demanded power of the equipment exceeds the UPS s rated output power If overload persists during battery operation the UPS may shut down High temperature Overtemperature shut down during battery operation can occur from e extreme environmental temperature e lack of proper ventilation e overload situation When the pre alarm sounds check these conditions to avoid shutdown or damage If the temperature rises further the UPS will e if it runs on mains switch off the battery charger e if it runs on battery switch off completely Output voltage is no longer available Programmed shutdown The UPS monitoring software allows you to program a sleep period of the UPS by sending t
7. indicated on the rating label 2 1 Installation Rules e The UPS is intended to be used in normal domestic and office situations e Protect the UPS according to the wiring rules with a 16A D type fuse e The UPS must be powered from a single phase grounded wall outlet Do not use extension cords e Avoid locations that are excessively humid near water near heat sources or in direct sunlight e The ambient temperature should not exceed 40 C Optimal battery lifetime is obtained if the ambient temperature does not exceed 30 C e It is important that ventilation air can move freely around and through the unit Do not block the air vents e Do not plug appliances such as electric heaters toasters and vacuum cleaners into the UPS e Becareful when connecting laser printers be sure that the demanded power does not exceed the capacity of the UPS e The sum of the leakage currents of the UPS and the connected loads should not exceed 3 5mA OPM_MAE_19X_700_1K5_2GB_V030 2 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 2 2 Installation Procedure w 5 4 d lt i o A a N h ho A 1000 1500 VA om i models pa ae eae eae Sa fig 1 1 Remove the transport screws A fig 1 and store them in the free holes B fig 1 Mount the Match 19 UPS in the 19 rack The module must be supported by mounting rails do not mount it by using the
8. 0 GB GE Digital Energy 6 Troubleshooting Whenever a malfunction occurs first check external factors e g connections temperature humidity or load to determine whether the problem is caused by the unit itself or by its environment Subsequently check the input fuse it may be blown If so replace the fuse see 5 2 and be sure that the UPS is not overloaded The following chart is a simple troubleshooting checklist only If the suggested solution does not succeed or if the information is insufficient to solve the problem please contact your dealer or consult www gedigitalenergy com PROBLEM POSSIBLE CAUSE SOLUTION Connected equipment not Overload causes reduced output Reduce load operating properly buzzer sounds voltage continuously Blown input fuse UPS overload Reduce load read 5 2 replace fuse System failure Please contact your dealer or consult www gedigitalenergy com UPS will not switch on to normal Line cord not connected Read 2 2 Installation operation LED on remains off Connect line cord charger off Dead socket outlet or mains Contact qualified electrician voltage lt approx 187Vac or mains Battery start is possible see 3 1 2 frequency out of tolerance UPS overtemperature Read 2 1 Allow UPS to cool down UPS will not switch on to normal Mains voltage between 165 Contact qualified electrician operation LED on blinks 187Vac UPS will not switch to battery Batteries depleted Allow the UPS
9. GE Digital Energy Match 19 Uninterruptible Power Supply 700 1500 VA iF Match S TCS a aam D avr D progr shutdown D replace battery rt PAN O LO Manufactured by GE Digital Energy General Electric Company Telephone 41 0 91 850 5151 Py ISO 9001 CH 6595 Riazzino Locarno Fax 41 0 91 850 51 44 K KEMA CERTNR 19167 Switzerland Website www gedigitalenergy com 01 02 1992 DESIGN PRODUCTION OF UPS Match 19 UPS Technology for the Digital World ver 3 0 GB GE Digital Energy USER MANUAL Match 19 Uninterruptible Power Supply 700 1500 VA Please read these instructions carefully before installation and start up of the Match 19 UPS Keep this manual in a safe place for future reference CONTENTS 1 INTRODUCTION cecenii ieren ennea nra eis neil eee eerie ets 2 1 1 Introduction 1 2 Safety Rules 1 3 Transport Storage 2 INSTALLATION iinaneien nunai a ei a a i aa a a aa adaa 2 2 1 Installation Rules 2 2 Installation Procedure 3 OPERATION udicama anaiai aaia a a a a a aaa aala a aada 4 3 1 Start up 3 1 1 Start up mains available 3 1 2 Start up mains not available 3 2 Use Normal Operation 3 2 1 Normal operating conditions 3 2 2 Load indication 3 2 3 Auto off no load shutdown 3 2 4 Battery test 3 2 5 Switching off 3 3 Use Status and Alarm Indications 3 3 1 Charger on 3 3 2 Normal operation 3 3 3 AVR active 3 3 4 On battery 3
10. front brackets only The front brackets allow mounting of handles not included 2 Make sure that the air vents in the side panels of the module are not blocked by the mounting rails or the side panels of the 19 rack 3 Switch off your computer and unplug it from the socket outlet 4 Disconnect the power cord from the computer rating 250Vac 10A and connect this cord to the mains input socket 2 fig 1 of the UPS See fig 2 fig 2 5 Using the output cord s provided connect the computer s to the appliance outlet s 4 fig 1 of the UPS Spread the loads over the appliance outlets as equally as possible If you use a distribution box to connect more than one appliance per outlet please note that the maximum AC current fig 3 rating of each appliance outlet is 10Amps See fig 3 E J 6 Connect the mains cord of the UPS to a working grounded AC wall socket outlet See fig 4 The 2 green LED on 7 fig 6 will blink power is available g and the batteries are charging If the LED does not blink press l briefly Probably LED replace battery lights up the LED goes out as soon as the batteries fig 4 have been charged 7 For best results allow the UPS to recharge the batteries during a period of approx
11. ithout connectors steel plastic IP20 EN 50091 1 1 EN 50091 2 10 to 40 C lt 35 dB A 95 non condensing 10 GE DE Match 19 700 1500 User manual 3 0 GB
12. r shutdown A replace battery on battery Match 40111213 14 Situation Indicators on front panel on alarm repl batt progr avr shutd on batt buzzer Charger on 3 3 1 Normal operation 3 3 2 Automatic voltage regulation 3 3 3 On battery 3 3 4 1x 8 s Battery low 3 3 5 1x s Replace battery 3 3 6 Overload 3 3 7 High temperature 3 3 8 1x s Progr shutdown pending 3 3 9 Progr shutdown in progress 3 3 9 Operating modes and corresponding indications see 3 3 1 3 3 9 OPM_MAE_19X_700_1K5_2GB_V030 intermitting continuous resettable press push button l gt 2 secs GE DE Match 19 700 1500 User manual 3 0 GB 3 3 1 3 3 2 3 3 3 3 3 4 3 3 5 3 3 6 3 3 7 3 3 8 3 3 9 GE Digital Energy Charger on The batteries are charging see 2 2 step 6 Normal operation See 3 2 1 AVR Automatic Voltage Regulation active The quality of the incoming mains is poor and the AVR boosts a low incoming voltage or reduces a high one see chapter 7 On battery The UPS uses the energy stored in the batteries see chapter 7 Batteries runtime The UPS will shutdown e after the batteries have been discharged automatic restart or e if keypad O is pressed manual restart required or e if a UPS shutdown command is
13. tents electrolyte may be extremely toxic If exposed to electrolyte wash immediately with plenty of water Avoid charging in a sealed container Never short circuit batteries When working with batteries remove watches rings or other metal objects and only use insulated tools Battery replacement procedure Refer to the label on the battery drawer 1 Be sure that the transport screws A fig 1 have been removed 2 Remove the front panel of the battery compartment Use a screw driver or pen as a lever 3 Remove the two screws that hold the battery drawer 4 Disconnect the DC connectors Use a screwdriver as a lever 5 Remove battery drawer Be careful heavy weight 6 Remove clamp two screws and replace the batteries T Reinstall battery clamp do not pinch or clamp the wires 8 Slide in the battery drawer 9 Connect the DC connectors a small spark is normal Fasten the two screws 10 Reinstall the front panel o fig 9 5 4 UPS Configuration Tool With the UPS configuration software that came with the unit on CD ROM you are able to change the setting of the auto off function 3 2 3 Insert the CD ROM in your computer and 1 Select RUN from the start menu 2 Type a conftool type for a the appropriate drive letter 3 Press ENTER See also a README TXT OPM_MAE_19X_700_1K5_2GB_V030 8 GE DE Match 19 700 1500 User manual 3
14. tly to an Ethernet network When this card is installed the RS232 communication link is no longer available For more information please refer to the user manual that comes with the interface card 5 Maintenance 5 1 General The UPS is virtually maintenance free take care of proper environmental conditions and keep air inlets outlets free of dust Please read 2 1 5 2 Fuses If the AC input fuse 1 fig 1 is defect be sure it is replaced by a compatible fuse from the same make and type FERRAZ TISP 5x20 or LITTLEFUSE 215 5x20 or WICKMANN 19181 5x20 Fuse ratings see chapter 7 5 3 Batteries 5 3 1 General The service life of the battery is up to 6 years depending on operating conditions As a healthy battery is critical to the performance of the UPS keypad I allows a Quick Battery Test see 3 2 4 When the condition of the battery is critical a replace battery alarm will be generated Replace the batteries as soon as possible See 5 3 2 OPM_MAE_19X_700_1K5_2GB_V030 7 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 5 3 2 Battery replacement WARNING first read the safety rules in section 1 2 When replacing the batteries use the same number and voltage V capacity Ah Proper disposal or recycling of the batteries is required Refer to your local codes for disposal requirements Never dispose of batteries in a fire they may explode Do not open or mutilate batteries their con
15. to recharge the operation batteries Battery drawers not connected Read 5 3 2 Connect battery drawers System failure Please contact your dealer or consult www gedigitalenergy com UPS switched off automatically Shut down by external software Wait until mains returns command during mains failure UPS overtemperature Read 2 1 Allow UPS to cool down Mains failure battery discharged Wait until mains returns Programmed shutdown in progress See 3 3 9 The load is lt 5 of the max load Wait until mains returns and no mains power is present No load shutdown function is active see 3 2 3 LED replace battery illuminates Quick Battery Test just after Allow the UPS to recharge the buzzer is silent installation or mains failure batteries Quick Battery Test shows weak Read 5 3 replace the batteries battery OPM_MAE_19X_700_1K5_2GB_V030 9 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 7 Specifications Match 19 model Ratings Voltage Amperes VA with computer type load Watts W with resistive load Input AC input voltage AC input voltage window Maximum AC input voltage Minimum start up AC voltage Input frequency Input frequency range No load power consumption normal operation AC input current A AC input fuse A Output AC output voltage AC output voltage tolerance Output frequency Output frequency in case of battery start Output frequency stability Output waveform
16. wo commands to the UPS e shut down after minutes blinking LED and subsequently e shut down during hours continuous LED The programmed shutdown in progress can be cancelled press keypad l for at least 5 seconds to cancel shutdown and switch UPS on press keypad 0 for at least 5 seconds to cancel shutdown and switch UPS off OPM_MAE_19X_700_1K5_2GB_V030 6 GE DE Match 19 700 1500 User manual 3 0 GB GE Digital Energy 4 Communication 4 4 RS232 Port fig 8 The RS 232 Port is a plug in interface port 9 pin Sub D male which enables advanced communication between the UPS and the computer interface kit required We strongly recommend to use only original GE Digital Energy software products in combination with the interface port Pin Function fig 8 1 RS232 input UPS shutdown 2 RS232 output sto 3 No function E De inc 4 Plug and Play Rs232 Le O 5 Common 1O 6 No function K 7 216 Q 7 Battery low RS232 O 8 UPS connected LK m TO 9 Mains failure 1 p aE MAX 48V 100mA 4 2 Relay Interface Card option 1000 1500VA only The card is equipped with potential free change over contacts for the following alarms mains failure battery low For more information please refer to the user manual that comes with the interface card 4 3 SNMP Interface Card option 1000 1500VA only This card allows the data interface to be connected direc

Download Pdf Manuals

image

Related Search

Related Contents

Betriebsanleitung  Operating manual -Lightw  Samsung AQV12VBE User Manual  aparelho de dermosucção dermo vacuum  Samsung 932GW Computer Monitor User Manual  6 La programmation du POSITIP 880  PDF Manual - Pocket Informant  取扱説明書(保証書別添)  Bubble Grasslin Time Clock Operating Instructions  取扱説明書 - ARK Design USA  