Home
CHRONOPRINTER 545 User Manual
Contents
1. TAGHeuer PROFESSIONAL TIMING CHRONOPRINTER 545 User Manual Version 11 2014 amp TAG Heuer Timing Page 1 49 Table of contents Introduction The Keyboard Qu 4 1 4 2 1 2 3 Rear Connectors 4 ick operation guide Battery installation amp replacement rechargeable NiMH battery Switching the CP 545 ON and Synchronise 5 Menu description before opening up a new run 5 10 5 11 6 Me 6 13 Power OFF CP 545 Op New Run Manual or External Synchronisation Clear Memory Rank a RUN of a single run Timing Modes Jumping Parameters Set Count Down Set Race Time Ph1 Set Race Time Ph2 Set Time P Ph1 Set Time P Ph2 Set Pause Penalty Parameters Precision Lock Time multiple impulse filtering Numbering except PTB SEQ Inputs Status LCD Contrast LCD Backlight Lighting Off Time LCD Delay Beep RS232 PC Ethernet Language Battery type Setting print Speed Printer Download nu description once Run is open Close a Run Ranking Rank a Run Listing List a run Still on Course Duplicate Insert Time Speed Parameters Printer Merge arun Download 7 Specificity the timing mode 7 1 7 2 Addition of runs BIBO rule 8 JUMPING MODE details EJ TAG He Input Configuration Menu Jumping Parameters Timing Mode Jumping Speed Mode Jumping 2 Phase Jumping SNG Phase Points penalties uer Timing Page 2 49 00 00 00 oO oO oO OO OO Om A 8 6 To Pause 8 7 Fu
2. E1 EZ or E4 The LCD will display all times from the Input you have selected Each time has a bib number in front to identify it This number cannot be not changed You have the possibility to select press Enter lt 44 to validate any other times with competitors number After changing a competitor s time you have to request a Ranking to recalculate the rank of all competitors 8 8 Identify a competitor It is possible to re identify a session of a competitor ev times which are not validated N bib you want to change R New Bib Number Example 3 R 4 lt gt all times from 3 will be re identified as 4 If the New bib number is already used the Chronoprinter will copy all times to a new Session of Time 9000 9001 etc Example 3 R 4 lt gt all times from 3 will be re identified as 4 If the Session of Time is already used all times from 4 will be re identified as 9000 You th have the possibility to re identify the group 9000 with another bib number 8 9 Disqualify Re qualify a competitor It is possible to disqualify a competitor by N R 0 al The D will be printed in front of the time and the competitor will be completely removed from the Ranking The times are still identified to the competitor but the flag D indicates that the competitor is Disqualified Disqualify Competitor Example 1 R 0 Re qualify a competitor N of competitor disqualify R N competitor Exampl
3. Print Setting gt Printer 5 10 ON OFF gt Copya Run gt Addarun gt Decharger 5 11 gt To display FIS Run list gt To PC gt To Chrono RS232 22 To opa run menu gt Ouverture d une manche gt PTB SEQUENTIEL gt NET TIME Add a run Run list BIBO START FINISH gt PARALELLE SEQ Add a run Run list gt PARALELLE DIFF Add arun with penalties Run list gt TRAINING gt SPLIT If the time of day synchro is selected to Start at Zero a reset SPLITLAP time to Zero is possible anytime during a run gt JUMPING amp TAG Heuer Timing Page 46 49 23 Technical specifications gt General gt Inputs Outputs Keyboard gt Display gt Printer Time Base d Operating temperature Internal power supply External power supply Autonomy Case J U Y YY Y Dimensions Weight PLEASE NOTE Stand alone multi sport timing system Timing calculation Speed to the 11 600 000 sec Timing resolution printer PC from 1 sec to 1100 000 sec Memory of 30 000 times and 99 timing sessions Sequential N competitor N from 1 to 9 999 Four banana jack inputs for external timing impulses working contact or closing contact without potential short circuit opcollector COMPUTER Bidirectional RS232 or to drive external display ETHERNET Expansion port for planned Docking Stations One key to turn ON the device Numerical keyboard Three keys UP DOWN and ENTER Four validation keys
4. The times printed will be 10x superior 1 03 218 Here print 1 03 218 Timing Modes With truncation Without truncation NET TIMES PTB SEQUENTIAL NET TIMES 2 INTER PARALLEL DIFFERENTIAL PARALLEL SEQUENTIAL START FINISH TRAINING START FINISH 2 INTER SPLIT SPLIT LAP JUMPING 3 modes Results by default are 1 100 sec Results by default are 1 1 000 sec Selectable timing resolution Selectable timing resolution from 1 sec to the 1 10 000 sec from 1 sec to 1 100 000 sec ATTENTION The RS232 and Ethernet ports always communicate the time of day to the PC with the same timing resolution as giv on the CP 545 s printer This avoids calculation and results errors oft observed if you compare the results giv by the timing device to the software running on your PC 5 8 2 Lock Time multiple impulse filtering Lock out time of the 4 inputs is selectable from 0 01 to 9 99 seconds To enter 1 00 sec press 1 0 0 and validate with q The minimum lock out time of 0 01 sec should not be used with any mechanical triggering device bounce may cause several impulses received ATTENTION For your convenience default lock times are pre programmed for each timing mode and can be modified by you amp TAG Heuer Timing Page 11 49 9 8 3 9 8 4 9 8 5 5 8 6 5 8 7 5 8 8 Numbering except PTB SEQ Manual or Automatic competitor numbering assigned to any of the 4 inputs Automatic in ascending UP
5. These menus are available before a Run is opened Several menus can be found wholly or partially in the Run Menu see chapter 21 To navigate the menus press F To select an option use the Wand Akeys and confirm with At any time it is possible to exit menus by pressing the F key the number of times necessary to return to the main menu 5 1 Power OFF CP 545 Switch OFF the device 5 2 Op New Run Start a new timing session after having closed the previous run 5 3 Manual or External Synchronisation Wh the CP 545 is powered ON the memorised Time of Day and Date proposed is the one used during the last timing session Use Synchronise Manual for a new Time of Day setting or to synchronize with other systems to a pre set Time of Day Do not forget to introduce the Date It is also possible to synchronize the time from 00 00 only in SPLIT and SPLIT LAP mode wh a restart back to zero may be required Master Slave La selection Master Slave wh we connect together via RS232 two Chronoprinter 545 5 4 Clear Memory Use only wh you start a new timing session and you are sure you do not need to retain previous runs in the device s memory 5 5 Rank a RUN ofa single run Rank a single run or the addition of two or more runs Example ranking from the addition of 3 runs List of runs 03 02T General ranking from the addition of run 03 and 02 T gt 03 Ranking of run 03 added to run 02 T 02 01 General ranking from the ad
6. E1 E4 RECALL key Paper feed key Four manual triggering buttons to block and unblock the external Inputs Matrix LCD display with backlighting Eight information lines with 21 characters Adjustable contrast and brightness Continuous rapid thermal printer 24 characters per line Automatically turns off whbatteries are low or turn off manually Thermo compensated quartz 12 8 MHz Precision 0 5 ppm at 25 C Precision 1 5 ppm betwe 30 C and 65 C From 20 C to 60 C Docking Station available late 2008 recommended for low temperature Five battery NIMH Sanyo 1 2V 2Ah ref STHAANIMH 12 V DC by adaptor HL545 1 or 12 V batteries 12 000 printed times from full powered battery NIMH Sanyo Glass filled Polyester P66 Santoprene 270 x 100 x 65 mm CP 545 without transport case 860g with battery set and 1 paper roll CP 545 with transport case and power supply 1 800g Some technical specifications could be modified or improved without any advice This is to guarantee the evolution of our devices and accessories amp TAG Heuer Timing Page 47 49 24 Pin out RS232 N RJ12 1 Rxd 2 synchro In 3 GND 4 Synchro Out 5 TxD 6 123 4 5 6 25 Accessories Docking Station BATT GPS GSMGPRS Internal battery e Lithium lon rechargeable battery which ensures the autonomous operation of the CP 545 for long duration timing sessions evat low temperatures 20 C GPS Mod
7. Page 14 49 5 8 13 Battery type Three selections available No rechargeable standard battery type Alcalin AA 1 2V NiMH active Charge to enable the charging with NiMH battery ONLY NiMH disable Charge the charging process is disable This selection is mandatory wh the battery type is not NiMH type IMPORTANT The charge should be not made with a temperature lower than 0 C It is important to select the correct type of batteries NiMH to use the internal charger circuit If type of battery is different than our recommended NiMH please disable the charging Process No warranty will be available if users do not respect this rule TAG Heuer reference for NiMH battery STHAANIMH 5 8 14 Setting print Prints the complete setting of the CP 545 the memory status Timing Mode accuracy input status lock time and battery level 5 9 Speed Selectable Speed unit of measurement is m s Km h Miles h and Knots Four different speed measurements can be configured betwe the 4 inputs Ex for Speed 1 betwe inputs 2 and 3 at a distance of 10 meters Start Press 2 and validate lt Stop Press3 and validate lt 4 Distance To input the distance betwe the photocells in millimetres Press 10 000 and validate Use to correct any input error Re enter the input correctly th validate When finished for instance if only one speed trap is to be configured simply press F PLEASE NOTE Speed measurements are possible
8. amp TAG Heuer Timing Page 13 49 To HL 970 980 With this setting you will have the right to display some information directly from the CP 545 to the LED Display HL 970 or HL 980 Running time at 1 of second gt Net Time Start Finish Training PTB Sequential Line 1 Running time Net Time Line 2 Comp Line 3 Speed 1 if selected gt Parallel Diff Seq Line 1 3 Line 2 4 Penalty Result gt Split Comp Split Time Number of Split Total Split gt Jumping Line 2 Running time Net Time Line 3 Points gt Time of Day gt Blank display Blanking By default Running time Display time from 1 to 59 sec with adjustment A Plus W Minus th validate with lt 4 by default 10 sec Advertising 1 to 16 It is possible to start an advertising program memorized into the Power Box of HL970 or into our MiniDisplay HL975 directly from CP 545 5 8 11 Ethernet Activation ON or OFF Actif port 7000 13500 13501 13502 et 13503 ATTENTION It is possible to switch ON the Ethernet Port in same time that Power ON the CP 545 but pressing simultaneously the gre button 4 wh switching ON the CP 545 NOTE The Ethernet communication port has continuous power consumption and therefore is OFF by default It must be turned ON each time you power up the Chronoprinter 5 8 12 Language The CP 545 is programmed in English French German Italian Spanish and Russian amp TAG Heuer Timing
9. battery life We recommend you consider purchasing one of the Docking Station for extended autonomy in situations wh AC power is unavailable The autonomy of the Docking BATT will allow you to print 20000 times at 20 C and at least 10 000 times at 20 C GPS OFF and LCD back light at 0 WARNING Pay attention to the autonomy of the batteries and of the paper roll if you have to print any times It is recommended to set the back light of the LCD at 0 for a longer autonomy IMPORTANT It is strongly recommended that you remove the battery if you are not using your Chronoprinter 545 If using the Docking station HL540 BATT You have the possibility to extend the autonomy amp TAG Heuer Timing Page 26 49 15 Information about Timing Modes Each Timing Mode has parameters that are memorized default based on those giv during the last timing session Each Timing Mode proposes the main parameters memorized by default or used during the last timing HELER session CHRONOPRINTER 545 Example N 0003 V A 08 PTB SEQUENTIAL Mode DATE lt DMY gt 04 12 07 HOURS lt HMS gt 14 07 34 MEMORY FREE 26500 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PTB SEQUENTIAL PRECISION 1 1000 SEC INPUT 1 LOCK TIME 1 00 S INPUT 2 LOCK TIME 0 10 S INPUT 3 LOCK TIME 0 10 S INPUT 4 LOCK TIME 0 10 S RS232 OUTPUT TO PC BAUDS RATE 9600 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk ETHERNET OFF kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PTB SEQUENTIAL e 4 active
10. irier Speed Distance m A nia nale poni h BET tas Ela ee Ai Frai pari Tha spad channel x musi ba SEPORE te niemals channa x on Dore Q a O amp TAG Heuer Timing Page 41 49 19 3 Ethernet connection test To test the Ethernet connection betwe two systems e Select Start gt Run e Enter CMD th validate with OK m Type the name of a program Folder document or dE Internet resource and Windows will open it For you Open cradh Cancel Browse e Enter IPCONFIG than validate with on ENTER C Documents and Settings gt ipconfig The IP address of your PC is irre a writt as follows tar thernet Connexion r seau sans fil Address IP 192 168 1 51 Statut du m dia thernet Connexion au r seau local Suffixe DNS propre la conn Adresse IP Masque de sous resesu Passerelle par defaut C Documents and Settings e Enter PING followed with the IP consentono address of your CP 545 C Documents and Settings gt ping 193 168 1 Sp Enuoi d une requ te ping sur 192 168 1 50 avec 32 octets de donn es ponse de 192 168 1 50 octete 3 tomps 129 ms TTL 64 PING 192 168 1 50 T D 158 1 56 ctets 32 temps 29 ms TTL 64 d do 192 168 1 58 octa 32 tomps 28 ms TIL 64 noe de 132 168 1 50 octete 32 temps 27 me TTL 64 Sb a O p rt QA ondes C Documents and Settings gt y e If the link is not working please check carefully the following a IP address of your
11. second run will follow the ranking of the first run amp TAG Heuer Timing Page 18 49 8 JUMPING MODE details These three modes allow you to time in Stand Alone a Jumping Race with or without Jump Off directly with our Chronoprinter 540 With these modes you will be able to add and remove Penalties Stop Restart automatically calculate points penalties time limit penalties phase 1 or 2 and also automatically add Pause Penalties wh they are required 8 1 Input Configuration Input 1 Start Jumping Timing Input 2 Jump off only for modes Jumping 2 Phase or Jumping Sng Phase Input 3 Start Count down Pause amp Restart Input 4 Finish 8 2 Menu Jumping Parameters Set Count Down Set the count down before the start signal 30 or 45 sec If countdown is not required you set to 0 If setting to 0 each competitor has to be validated by pressing input 3 prior manually Set Race Time Ph1 Set the Time limit for Phase 1 sec If the value is set at 0 no time penalties will be added Set Time P Ph1 Set Penalty in Ph1 wh time limit is exceeded 0 25 pts sec Set Race Time Ph2 Set the Time limit for Phase 2 sec If the value is set at 0 no time penalties will be added Set Time P Ph2 Set Penalty in Ph2 wh time limit is exceeded It is possible to set the points penalties time example 0 25 pts 1 sec or 1 00 pts 4 sec Set Pause Penalty Set a default Time Penalty if pause is r
12. the CP 545 batteries should have a good life or alternatively connect the external power supply The RESET is available with CP 545 ON or OFF amp TAG Heuer Timing Page 23 49 12 Mass Start or Group Start GRP The start time could be provided by a timing impulse or at a pre defined time 12 1 Start with a timing impulse The impulse is provided by a start gate a photocell or a manual contactor on Input 1 Select NET TIME menu Timing Modes Op a New Run Input a competitor N at the start N E1 N 1 in our example Give the start by an impulse on INPUT 1 manual or external Select Duplicate menu Input the N to be duplicated N 1 in our example The N and the start time are displayed Duplicate one or several competitor N started at the same time as N 1 gt Other N ____ ifthe competitor N are not in chronological order ex 2 5 9 etc gt N From____ to ____ if the competitor N are in a chronological order eg from 2 to 10 WARNING If you input a lot of competitor numbers in the same group eg 1 to 150 it could take several seconds to proceed to the memorisation 12 2 Start a defined time The start s time s must be programmed in the CP 545 after you op a New Run e Select NET TIME menu Timing Modes Op a New Run Select Insert Time and E1 Menu Input a competitor N eg N 1 and th the start defined time ex 12 34 00 000 If one or more competitor numbers are starting at the same
13. time select Duplicate and follow the steps as described above WARNING The defined start times must be referenced with the time of day of your CP 545 Synchronise amp TAG Heuer Timing Page 24 49 13 Changing the paper roll It is best to change the paper roll before the existing roll is about to run out A red border on the paper indicates that the paper is about to run out The change can also be carried out during the timing session ev in emergency wh there is no more paper thanks to the fact that all times are memorized while the replacement is going on The memorized time will be printed on the new paper roll gt Before the end of the paper Enter the MENU select PRINTER th OFF Printer disabled As soon as the change is carried out don t forget to turn the PRINTER back to ON gt Whlthere is no more paper The printer is automatically switched OFF It will print again automatically as soon as the new paper roll is in place All times are recorded ev if the Printer is OFF We recommend you check the status of your paper roll before the start of a race and replace it with a fresh roll if it is about to run out Op the paper compartment To op the paper compartment use your thumbs to slide it toward the back of the device To slide it back into place put the cover flat about 3 4mm behind its closing position PLEASE NOTE The paper roll is firmly supported by two lateral half moons to prevent it from movi
14. to observe the status of TAG Heuer s new direct response photocells HL2 31 amp HL2 35 serial number up to 7000 and allows the timekeeper to instantly determine if a photocell is out of alignment This audio alarm is also available with our Data amp Impulse Radio transmission HL670 HL615 3 The same message is printed with the device N ID and the software version along with the timing mode and the main parameters used during your last timing session 4 If the CP 545 doesn t print enter the menu F select PRINTER ON and validate You should check your batteries and replace if necessary Synchronise the CP 545 refer to chapter 6 3 if needed Select a Timing Mode refer to chapter 5 6 Check timing parameters precision lock time etc refer to chapter 5 8 Op a Run start the Timing session Example of how to start a new Timing session a Enter into the menu F b Clear the memory c Timing mode you may change this if desired d Parameter If changes are needed Precision Blocking etc e Synchronise manual at Time of the Day to correspond with other systems or time proposed by you on the CP 545 or start at 00 00 f Op a new run begin the timing session 33 PLEASE NOTE If the same Timing Mode is reconfirmed through this menu Mode Chrono sequence the parameters by default are restored amp TAG Heuer Timing Page 7 49 5 Menu description before opening up a new run
15. 49 7 Specificity the timing mode 7 1 Addition of runs In NET TIME and START FINISH mode in the opening of a new run Before to close a run be sure that the results are correct It is not possible to make further modifications after a run is closed If you want to add a previous run to the new one select your choice in the menu List of Runs After that the CP 545 will ask you Activate BIBO in the NET TIME START FINISH Modes It is also possible to combine 2 runs already closed Select Rank a run one of the run you want to add 7 2 BIBO rule In NET TIME and START FINISH mode in the opening of a new run BIBO is a very familiar feature in Alpine Ski racing It refers to the establishment of a reverse running order of a certain number finishers from the results of a proceeding run The input of a BIBO value as required Most FIS and USSA events use flip 30 In other words the top 30 finishers from the first run will run in reverse order in the second run Ex If you flip the 1 30 competitors the start order will refer to the competitor ranked from the 30 position to the 1 and th to the 31 and up If BIBO is not activated the starting order will refer to the ranking of the proceeding run PLEASE NOTE If several competitors are ranked with the same time tie at the 30th position in the proceeding run BIBO will take in account these entire competitors N s If BIBO is not enabled the start order of the
16. 8 49 39 575 8 51 00 848 6s 8 51 13 599 4 Open run N 3 Information on Setting of the Race Count down value 30 sec Time Ref 1 time allowed for Phase 1 92 sec Time Pen sec Time penalty second 0 25 Start Count Down input 3 Impulse on Input 1 start Phase 1 Value of the count down Input 1 Validate time competitor N 5 Pause is activated Input 3 Validation of the Pause Penalty 6 sec Pause is ignored Input 3 Introduction of Point Penalty 4 Introduction of Point Penalty 8 Remove Points Penalty 8 Finish phase 1 input 2 Input 2 validate time Competitor N 5 8 51 19 004 8 51 19 004 Competitor Countdown Result of the Competitor 5 Value of the count down 2 2 Sec On phase 1 Point 4 points Pause penalty 6 sec Time Penalty 0 25 points Ranking 3 Net time 64 30 sec Phase 1 amp TAG Heuer Timing Page 37 49 3 9 43 03 8 1 9 43 28 958 Countdown 4 8 1 9 43 28 958 9 43 8 958 9 43 06 236 9 44 12 659 9 44 32 263 9 44 51 574 9 44 57 924 9 44 57 924 Competitor Countdown Phase 1 Points Pause Penalty Time Penalty 9 45 58 047 9 45 58 047 Competitor Countdown Phase 1 Points Pause Penalty Time Penalty R Phase 2 Points Pause Penalty Time Penalty amp TAG Heuer Timing Start Count Down input 3 Impulse on Input 1 start Phase 1 Value of the count down Inp
17. EL SEQ 15 29 51 720 amp TAG Heuer Timing Page 29 49 16 2 NET TIME Mode HELJER NET TIME RUN N 01 Open run 1 PRECISION 1 100 SEC MEMOIRE FREE 26500 DATE lt JMA gt 04 12 07 TIME lt HMS gt 13 33 19 14 13 33 26 537 GE 1 13 33 30 453 1 13 33 34 781 N 5 E1 N 4 did not start DNS 1 13 33 48 576 1 13 33 54 178 E1 False Start for N 7 1 13 33 59 239 False impulse need to be deleted R E1 0 1 13 33 59 239 N 7 Starts 1 13 33 59 239 1 13 34 28 484 N 1 Finish with its actual rank 4 13 34 35 927 lt 1 09 39 13 34 41 013 1 10 56 94 N 3 and 5 Finish Error af The correct order was N 5 followed by N 3 13 34 49 688 1 01 11 13 34 49 688 E4 E4 N 3 and N 5 False Finish ui R E4 to re identify times 13 34 49 176 Time of Day at the Finish 13 34 49 149 1 14 39 13 34 49 688 The order of the finish is unknown 1 01 11 Y E4 to disable the auto numbering R E4 to recall memorized time to manually 13 39 28 364 associate with a competitor 13 35 29 177 13 35 28 364 Ranking of the 17 run 1 34 18 13 35 26 177 1 00 68 kkkkkkkkkkkkkkkkkkkkkkkkkkkk RANKING RUN N 01 1 7 1 00 68 2 5 1 01 11 Le N 8 left 1 09 39 He gives up N 8 R 0 1 10 56 1 14 39 1 34 18 amp TAG Heuer Timing Page 30 49 RUN N 01 CLOSED Close run 1 menu NET TIME Open run 2 and append to run 1 MANCHE N 02 BIBO is activated to invert the first 3 competitors of KKK
18. KKKKKKKKKKKKKKKKKKKKKKKKKk the ranking from run 1 ADDED TO RUN N 01 BIBO 3 PRECISION 1 100 SEC MEMORY FREE 26478 DATE lt JMA gt 04 12 07 TIME lt HMS gt 13 51 57 11 13 52 18 269 Start order is proposed automatically with BIBO requested 5 1 13 52 22 364 7 1 13 52 25 857 2 1 13 52 29 403 3 1 13 52 33 771 6 1 13 52 37 836 1 4 13 52 47 658 R lt 1 gt 29 38 Time of run 2 G Ss 1 38 77 Total time General of run 1 2 for the competitor N 1 and with its rank 5 4 13 52 54 669 R lt 2 gt 32 30 G lt 1 gt 1 33 41 7 4 13 53 00 509 R lt 3 gt 34 65 G lt 2 gt 1 39 33 2 4 13 53 05 054 R lt 4 gt 35 65 G lt 4 gt 1 46 21 3 4 13 53 10 807 R lt 5 gt 37 03 G lt 5 gt 1 51 42 6 4 13 53 16 618 R lt 6 gt 38 78 KKKKKKKKKKKKKKKKKKKKKKKKKKKKk G lt 6 gt 2 12 96 GENERAL RANKING RUN N 02 01 1 5 1 33 41 i l u 2 7 1 35 33 General ranking with addition of run 1 and a 4 1 38 77 4 2 1 46 21 5 3 1 51 42 6 6 2 12 96 kkkkkkkkkkkkkkkkkkkkkkkkkkkk kkkkkkkkkkkkkkkkkkkkkkkkkkkk Ranking Run 2 RANKING RUN N 2 kkkkkkkkkkkkkkkkkkkkkkkkkkkk amp TAG Heuer Timing Page 31 49 16 3 PARALLEL SEQUENTIAL Mode UP PARALLELE SEQ Open Run 1 RUN N 02 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PRECISION 1 100 SEC MEMORY FREE 26482 DATE lt JMA gt 04 12 07 TIME lt HMS gt 15 44 37 1 15 44 43 585 N 1 Starts blue 15 44 45 232 N 2 Starts red 15 44 51 946 6 71 N 2 Finish with its actual rank me N 1 Fini
19. PC b IP address of your CP 545 c Connexion amp TAG Heuer Timing Page 42 49 20 Flow Char Main Menu Menu gt Switch OFF CP 545 Yes No gt Open Run Ready for Timing in the selected mode gt Synchro Manual External Master Slave AUX gt Clear Memory Yes no gt Rank a Run List of Runs gt Jumping Parameters only in jumping mode Count Down Time Ph 1 Time Pen Ph1 Time Ph 2 Time Pen Ph2 Pause penalties gt Timing Mode NET TIME TRAINING SPLIT 1 4 SPLIT 5 8 SPLITLAP JUMPING gt Parameters Precision Numbering Input Status LCD Delay Beep RS232 VVVVVVVVVVVBVVVVVVVVVVVVVVWV v Ethernet gt Language gt Battery Type amp TAG Heuer Timing PTB SEQUENTIEL 1 4 PTB SEQUENTIEL 5 8 NET TIME 2 INTER PARALLELE SEQ PARALLELE DIFF START FINISH START INTER FINISH JUMPING 2 PHASES JUMPING SNG PHASE Locking Time LCD Contrast LCD Backlight LCD Time OFF LCD Time display Remark Chapter 5 1 5 2 53 5 4 9 5 5 7 5 6 5 8 gt ToPC gt To HL960 990 gt To HL970 980 gt TO ALGE Std Connexion User Connexion French English Italian German Spanish Russian Page 43 49 Print Setting gt Speed m sec Km h Miles h Knots VVVV WV gt Printer ON OFF gt Download To display To USB To PC To Chrono RS232 VV VW amp TAG Heuer Timing Page 44 49 5 9 5 10 5 11 21 Flow chart of Run Menu Menu Rema
20. RANKING RUN N 02 gt BLUE kkkkkkkkkkkkkkkkkkkkkkkkkkkk Page 33 49 16 4 PARALLEL DIFFERENTIAL Mode TE PARALLEL DIFF RUN N 01 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PENALTY 2 9 PRECISION 1 1000 SEC MEMORY FREE 26500 DATE lt JMA gt 04 12 07 TIME lt HMS gt 16 31 29 11 16 31 48 864 BLUE WIN 2 4 16 31 49 042 RED 0 178 4 4 16 32 06 051 RED WIN 3 1 16 32 06 380 BLUE 0 329 5 1 16 32 26 940 BLUE WIN 6 4 16 32 32 750 RED 2 500 kkkkkkkkkkkkkkkkkkkkkkkkkkkk RANKING RUN N 01 BLUE RED 1 WIN 2 0 178 3 0 329 4 WIN 5 WIN 6 2 500 kkkkkkkkkkkkkkkkkkkkkkkkkkkk RUN N 01 CLOSED TE PARALLEL DIFF RUN N 02 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PENALTY NONE PRECISION 1 1000 SEC MEMORY FREE 26491 DATE lt JMA gt 04 12 07 TIME lt HMS gt 16 33 15 DIFF 1 0 000 DIFF 2 0 178 1 4 16 34 18 600 ROUGE WIN 2 1 16 34 19 120 BLUE 0 698 DIFF DIFF 0 000 3 16 35 25 040 RED A 16 35 29 745 BLUE DIFF l DIFF 2 500 5 16 36 22 252 RED 6 16 36 24 261 BLUE kkkkkkkkkkkkkkkkkkkkkkkkkkkk RANKIN RUN N 02 BLUE RED 2 0 698 WIN 4 4 376 WIN 6 4 509 WIN kkkkkkkkkkkkkkkkkkkkkkkkkkkk For run 1 a PENALTY of 2 5 seconds was introduced If a competitor does not cross the finish line it is NECESSARY to manually allocate the arrival impulse with green button 1 or 4 The time taken is the one of the introduced penalty For the run 2 WITHOUT PENALTY the differences during run 1 wi
21. START FINISH Stand Alone net timing using Start and Finish times with automatic or manual numbering Keypad shortcuts of corrections and RECALL of memorized times for later identification or modification This mode is similar to NET TIME mode the difference is in the results calculation For details please consult point 5 2 1 Ranking list and total time results including if several runs occur are added BIBO avalable in Alpine Ski mode START INTER FINISH Start with 2 intermediate times and finish time Automatic or manual numbering Ranking and addition of runs This mode is similar as NET TIME mode The difference is in the results calculation Please consult the point 5 8 1 TRAINING Start with two intermediate and finish times automatic numbering Run ranking and listing for each competitor in different runs SPLIT 1to4and5to8 Split times partial times or lap times with competitor numbering Ranking or listing of a competitor s lap times SPLIT LAP Split Times with competitor numbering JUMPING SPEED Jumping mode with single phase Count Down Start Finish JUMPING 2 PHASES Jumping Mode with two phase immediate Jump OFF Count Down Start Phase 1 Stop Ph1 Start Ph 2 Finish Phase 2 amp TAG Heuer Timing Page 9 49 JUMPING SNG PHASE Single Phase Jumping Mode with two phase separate Count Down Start Phase 1 Stop Phase 2 Start Phase 2 Stop Phase 2 Refer to the chapter 9 for a full description
22. Select Serial Port Serial Port comi EN Select File Name File Name DUIT Film Photo CP540 Update CP540_A08 dat Browse CP540 must be OFF before START is pressed START Select the COM Port Select the file Update CP 545_xxx dat Press START on the software Power ON the CP 545 press the ON button for 5 seconds The CP 545 will go into a special mode Download The LDC back light will be ON but LCD will be blank 9 As soon as the upgrade is downloaded into the CP 545 validate the software with OK 10 Remove the RS232 cable from the CP 545 and switch on the CP 545 again 11 The new software version will be printed if the Printer is in ON See 18 RS232 and Ethernet Protocol For details of the communication protocol please refer to the document THCOMO08 Please contact us directly at info tagheuer timing com amp TAG Heuer Timing Page 39 49 19 ETHERNET LINK CONFIGURATION UU 19 1 Connect CP 545 to PC via red Ethernet cable HL545 2 Configure the Ethernet configuration on your CP 545 menu Parameters gt Ethernet gt ON Validate the IP address or change it if necessary we recommend that you keep the default value at 192 168 001 050 Note if you are connecting several CP 545 s together via Ethernet it is imperative to set unique IP addresses for each unit Example CP 545 1 IP 192 168 001 50 CP 545 2 IP 192 168 001 51 Etc If your PC is already connected to a n
23. Sets the time that the Backlight stays ON betwe two impulses Adjust with A plus W less and validate with A shorter time ensures a better operational autonomy This function is not in use wh the CP 545 is powered LCD Delay LCD duration of the currently displayed information Adjust with A Plus V Less th validate 5 seconds is the default setting amp TAG Heuer Timing Page 12 49 5 8 9 Beep Audio signal activation ON or OFF 5 8 10 RS232 PC To PC with selectable serial Port Baud rate is selectable 2 400 9 600 38 400 57 600 9 600 Bas is the default setting To Display e Running Time on the TAG Heuer display HL960 HL 970 HL990 HL965 HL980 and other display as Alge e Running Time of Day of the CP 545 e Blank command to the Display Running time is the default setting Display duration of net times is adjustable from 1 to 59 seconds using the A Plus W Less arrows th validate with 10 seconds is the default setting To HL960 990 The CP 545 now also automatically updates any of the scoreboard displays listed above With the HL970 it is also possible to store competitor names and numbers within the HL970 control box Wh connecting the CP 545 to the HL970 you are able to display the following information Running time at 1 10 of second During the race RIS IT L A S T NIA M E Tr of DI race For more information please refer to the Matrix Display HL 970 user s manual
24. TAG Heuer Timing Page 35 49 16 6 Example Jumping Mode Open run N 2 JUMPING RUN N 02 KKKKKKKKKKKKKKKKKKKKKKKKKKKKk Information on Setting of the Race PRECISION 1 100 SEC Count down value 30 sec MEMORY FREE 26500 Time Ref 1 time allowed for Phase 1 92 sec DATE lt JMA gt 06 04 11 Time Pen sec Time penalty second 0 25 TIME lt HMS gt 15 44 24 nl SR n Start Count Down input 3 Time Ref 1 92 Tinie SE Impulse on Input 1 start Phase 1 S 3 Dee Value of the count down 1 17 00 22 227 Input 1 Validate time competitor N 7 CountDown 6 9 Introduction of Point Penalty 4 lt 17 00 22 227 Finish phase 1 input 4 Input 4 validate time competitor N 7 4 17 01 26 528 17 01 26 528 Result of the Competitor 7 Value of the count down 6 9 sec On phase 1 Competitor Point 4 points CountDown Pause penalty 0 sec Time Penalty 0 00 points Phase 1 l Ranking 6 Points Net time 64 30 sec Pause Penalty Time Penalty R lt 60 gt amp TAG Heuer Timing Page 36 49 16 7 Example Jumping Jump Off JUMPING JUMP OFF RUN N 03 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PRECISION MEMORY FREE DATE lt JMA gt TIME lt HMS gt Count Down Time Ref 1 Time Pen sec Time Ref 2 Time Pen sec 1 100 SEC 15 44 24 30 92 66 0 25 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk S 3 1 Countdown 5 1 P 3 Pause Penalty P 3 Points Points Points 8 49 11 3 8 49 39 575 2 2
25. ask will come E Cap get E permas assigned ee if potr Ge ea is Capability Otherwise you need to ask your network administrator for automatically 255 255 255 0 the appropriate IP settings Note C 3 Obtain an IF address automatically The IP addresses should be similar on LC the first 3 groups of the 3 numbers IP address 192 168 001 051 example 192 168 1 Subnet mask E 255 255 0 The last groups of 3 numbers should be erat EE ae e different ne Example Obtain DNS server address automatically CP 545 IP 192 168 1 50 Use the following DNS server addresses PC IP 192 168 1 51 Preferred ONS server Alternate DNS server If your PC is never connected to a LAN you can make this address permanent If not to retrieve to the original setting please select Obtain an IP address automatically 19 2 In SKI PRO MSPORT PRO etc x nd Select the type of Timing Devices and Wee HEUER CP 540 Channels 4 Parameters enter the IP address of your CP 545 Crt cont 0580 echte fer fr E Ten vg Doves Time measurement Speed measurement Paratel sech Anh Hei Speed ier Speed Distance m ne Speed 2 Inter Spesd Datance m interi hispeed Distance m we interSpeed Distance m tee sess ker Spend Distance m rec Spede iec Speed Distante m mero Speed Inter Speed Eistance m wes f Speed inier Speed Dees TI m res Speed
26. ce jury However use this function if no race jury exists and you desire to remove the athlete from the ranking due to disqualification Page 22 49 IMPORTANT The CP 545 will accept multiple times of the same competitor N at the start and at the finish The times tak into account in the ranking are the last one s recorded With each new start or finish the proceeding times are automatically unassigned It s strongly recommended to identify or to cancel these times as soon as possible This action will simplify your timekeeping NOTE This does not apply in the TRAINING mode whereby several runs for a competitor can be memorised for later analysis It is highly recommended to identify or delete all times not identified as soon as possible 10 Special characters memorized printed and sent to the PC Wh a time is unassigned false start inter or finish Any time modified through a manipulation of start number Any time inserted manually through INSERT TIME Menu Any time repeated through DUPLICATE Menu Any time cancelled through N R 0 or after a DNF or DSQ Any Start or Finish time of a forerunner ZE N O l 11 Special function RESET CP 545 A general RESET can be achieved by pushing the mini switch located below the battery cover RESET For this operation use a small unfolded paper clip or a needle WARNING After a RESET the memory is cleared and all parameters are restored To achieve a RESET
27. ctive inputs with competitor numbering Manual numbering by default Sequential N s for each input are sent to PC 4 active inputs with automatic ascending competitor N This mode allows independent timing of 4 competitors using 4 inputs Count down on Input 3 Start Stop function on Input 3 Start Phase 1 on input 1 Start Phase 2 on input 2 Finish on input 4 Validation of time ENTER Page 28 49 16 Example of Timekeeping sessions 16 1 SEQUENTIAL Mode UP SEQUENTIAL PTB RUN N 01 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk PRECISION 1 1000 SEC MEMORY FREE 26500 DATE lt JMA gt 04 12 07 TIME lt HMS gt 15 24 24 1 15 24 41 334 15 24 41 817 15 24 42 293 Sequential recording of Time of Day independent 15 24 42 801 on each channel 15 24 43 620 15 24 45 420 15 24 46 060 15 24 47 500 15 24 48 250 15 24 49 405 15 24 49 887 15 24 50 878 15 24 52 054 15 24 53 647 1 2 3 4 5 1 2 3 4 1 2 3 1 2 BRBWWWNHNNDNEB O 15 24 44 444 Manual time insertion on channel 1 SNCH 1 ui Speed measurement setting between Input 2 and START INPUT 02 3 with a distance of 10 metres STOP INPUT 03 DISTANCE 10 000 m 15 26 21 148 15 26 21 659 15 26 22 234 62 582 Km h 15 26 22 802 Speed is calculated with to a precision of 1 1 600 000 of a second 15 29 50 241 a 4 speeds are set in the PTB NET TIME START FINISH Ee TRAINING and SPLIT mode 78 311 Km h 1 speed by course track in PARALL
28. d no points penalties the software will restart automatically the start to count up for the Phase 2 until Impulse on Input 4 is validated In Timing Mode Jumping SNG Phase o The competitor continues the second phase automatically irrespective of any time faults penalties accrued in Phase 1 Do not close the run until you are sure that all data penalties are correct Once the Run is closed you cannot make any further corrections 8 5 Points penalties You can introduce points penalties during a competitor s run by entering the value of points eg 4 and validating by pressing Enter lt 44 Remove points penalties To remove points penalties during a competitor s run you have to press ZE and number of points you want to remove validating by pressing Enter amp TAG Heuer Timing Page 20 49 8 6 To Pause During the race Count down Phase 1 or 2 it is possible to pause the running time An Impulse on Input 3 will pause or restart The Chronoprinter will ask you to confirm the Pause Time Penalty if you have set a value greater than 0 The next impulse on Input 3 will restart the running time If an impulse on Input 3 is made in error it is possible to disable this impulse by pressing E3 Only the last impulse will be disabled 8 7 Function Recall The function RECALL will allow you to change a Start Time Jump Off time or Finish Time Press R Recall followed by the Input you need to edit
29. dition of runs 02 and 01 02 calls it 02 T 01 Ranking of run 02 added to run 01 Ranking of only run 01 Or with 2 run added ex 03 01 First select one of the 2 runs amp TAG Heuer Timing Page 8 49 5 6 Timing Modes PTB SEQUENTIAL 1 to 4 and 5 to 8 Sequential recording of time of Day on 4 or 8 channels if 2 CP 545 are connected together with RS232 connection directly to an external PC Uses bi directional communication with a PC running TAG Heuer or Split Second USSA CLUB NASTAR software where it is possible to print all net times current ranking and ev the competitor name and affiliation directly on the CP 545 printer NET TIME Stand Alone net timing using Start and Finish times with automatic or manual numbering Keypad shortcuts of corrections and RECALL of memorized times for later identification or modification Ranking list and total time results including if several runs occur are added BIBO available in Alpine Ski mode NET TIME 2 Inter Start with 2 intermediate times and finish time Automatic or manual numbering Also enables ranking and addition of runs PARALLEL SEQUENTIAL Independent Start and Finish times on parallel race courses with competitor numbers Ranking list of single or added runs same as with NET TIME mode New items with this mode you have the possibility to set a Count Down PARALLEL DIFFERENTIAL Time difference at the finish on parallel race courses Penalty and list of runs
30. e 1 R 0 amp TAG Heuer Timing Page 21 49 9 Keyboard shortcuts These important functions will help you during your timing sessions They are similar for most of the timing modes except PTB SEQUENTIAL Pay close attention to these shortcuts and to the RECALL function They allow you to act quickly in case of errors or unexpected situations To input or to change a competitor N before a Start or before a Start in Parallel SEQ on the blue course or before a Finish in Parallel DIFF on the blue course To input or to change a competitor N before the 1 intermediate or before a finish in Parallel SEQ on the blue course To input or to change a competitor N before the 2 intermediate or before a finish in Parallel SEQ on the red course To input or to change a competitor N before the finish or before the Start in Parallel SEQ on the red course or before the finish in Parallel DIFF on the red course N E1 Forunners numbering at the Start time calculate but not ranked E1 E4 V E1 E4 N R E1 E4 v R E1 E4 To un identify a competitor already started passed at an intermediate point or finished false Start false Intermediate false Finish The un identified unassigned times can be recalled with RECALL Ex R E4 for the finish time for re identification with a competitor N or with 0 zero to cancel them C To restore the previous situation UNDO if
31. e sure to have all possible modifications done 6 2 Ranking Ranking of the actual run if only one or General Ranking of combined runs 6 3 RankaRun Ranking of any memorized run or of the actual run if added with another gt Available for Training and Split Lap modes 6 4 Listing Listing of a competitor s number in a chronological order for the actual run all the memorized times for a competitor Available for Training and Split Lap modes 6 5 Listarun Listing of a competitor s number in a chronological order of any run 6 6 Still on Course The competitor still on the course net yet arrived 6 7 Duplicate Allows another or several competitor N s to be associated with a particular start intermediate or finish time already received Same function exists for mass starts or group starts 6 8 Insert Time Allows you to create a particular start of finish Time of Day for any competitor 6 9 Speed Refer to the main menu 6 10 Parameters Refer to the main menu Depending on which Timing Mode you select some parameters are not active 6 11 Printer ON or OFF Refer to the main menu 6 12 Merge a run Import all times from the selected run into the new run opened 6 13 Download To download to PC to Printer to USB or to Chrono Refer to the main menu WARNING Please refer you to the chapter 6 7 4 Inputs Status to setup the received CP 545 from another CP 545 amp TAG Heuer Timing Page 17
32. equested sec 8 3 Timing Mode Jumping Speed Wh you have configured the race Jumping Parameter and also configured the other important parameters including Input Numbering auto Manual and lock time see CP540 user manual you are ready to op a new run The normal sequence for this Timing Mode is Start Count Down Input 3 will start the session for a new competitor Start Race Input 1 Finish Race Input 4 During a jumping race the competitor will pass through the photocells several times All these passings will be recorded and printed to the CP 540 To validate a time you have 5 seconds after receiving the passing time to press Enter lt All times recorded are available with the function Recall for post editing Each competitor will be defined into the Chronoprinter as a group of times betwe the Start Count Down Input 3 ev if the Count Down value is setting at OU rom the first Input 3 Start Count Down to the last Input 4 Finish On the LCD you will have various information displayed during the race amp TAG Heuer Timing Page 19 49 Next competitor Locking Input 10 45 26 10 lt Time Ref Point Pause Penalty 0 Time Penalty 0 00 l l 10 46 32 23 Time to validate Competitor on run 10 2 36 Running time The sequence has to be respected Start Count Down Input 3 If the countdown 0 it will validate the competitor from Next competitor to Competitor on Run From this poi
33. ery To op the battery cover use your thumbs to firmly push it in the direction of the arrow Insert the batteries respecting the correct polarity as indicated at the bottom of the compartment WARNING To guarantee the security of your timekeeping it is recommended to use your CP 545 with the internal NiMH battery in a well charged state or with the Docking BATT Always remove the batteries if you don t use your CP 545 for several days If you forget to do this the batteries could leak and seriously damage the device The warranty does not cover this problem The time of day the date the memorized runs and the selected parameters are saved by a small internal battery 4 2 Switching the CP 545 ON and Synchronise 1 Press ON for 5 seconds 2 The LCD display will show a 4 black bars indicating that the a sm em 14 24 59 b RITI external Inputs are blocked 1 to 4 d Date lt DMA gt 14 11 2007 The time of day is memorized in the en EE 25000 CP 545 internal or after a ea SYNCHRO f ENTER THE MENU gt F b J Symbol indicates that the power supply is connected and E the charge of NiMH batteries c The date d The memory available LCD Screen e The Timing Mode used the last time f How to enter the menu amp TAG Heuer Timing Page 6 49 INNOVATION The CP 545 provides a visual on the LCD and audio alarm if an external input remains in short circuit This feature allows you
34. etwork server LAN its IP address is defined automatically You should th disconnect from the LAN and configure a special IP address for this application Configuration of your PC IP address e Select the program Network ER connection General Support Start gt Setting gt Control Panel rc i We suggest that you create a short cut SE tat Connect from your desk top to simplify the SES 00 30 20 access to the LAN a 10 0 Mbits s e Select Local Area Connexion e Select Properties r Activite Envoy s 4 Re us SA Paquets 553 31 Fermer e Choose Internet Protocol TCP IP A Local Area Connection Properties e Again select Properties General Authentication Advanced Connect using Sei Intel R PRO 100 VE Network Conne This connection uses the following thems el Client for Microsoft Networks ja File and Printer Sharing for Microsoft Networks loos Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol lnternet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity amp TAG Heuer Timing Page 40 49 e Select Use the following IP address Internet Protocol TCP IP Properties e Enter the correct IP address General Example 192 168 1 51 The Subnet m
35. in all the timing modes above with the exception of PARALLEL DIFFERENTIAL JUMPING 3 modes 5 10 Printer Printer may be ON or OFF To guarantee the best printing autonomy the speed of the printer is electronically controlled based on the voltage of the batteries If the voltage decreases the printing speed will slow down If the batteries fall below a certain voltage threshold the printer will automatically stop The running Time of Day on the LCD will flash To restore the printer connect an external power supply and th turn the printer ON again from the menu F If an external power supply is connected wh you turn ON the CP 545 the printer will be automatically ON amp TAG Heuer Timing Page 15 49 5 11 Download gt To PC downloads all of the times memorized in one run or in all runs through the RS232 port gt To Printer reprints all times memorized in one run or in all runs Be sure your batteries are fresh if not connected to the external power supply and that there is adequate paper especially if you will be printing many times Press to stop the printing at any time Download the time ofarun to aPC via USB To Chrono RS232 to download the time from a run from a Chronoprinter to another one It is important to set correctly the Input VV amp TAG Heuer Timing Page 16 49 6 Menu description once Run is open The following menus are available only wh a Run is open 6 1 Close a Run Before you close a run b
36. inputs with sequential numbering of time for each input NET TIME e Start on input 1 e Finish on input 4 e Inputs 2 and 3 are not using e Automatic numbering on Start and Finish e Calculation mode with truncation NET TIME 2 INTER e Start on input 1 e Intermediate and or speed on Inputs 2 and 3 e Finish on input 4 e Automatic numbering on start and finish Intermediate times with manual numbering by default e Calculation mode with truncation amp TAG Heuer Timing Page 27 49 PARALLEL SEQUENTIAL PARALLEL DIFFERENTIAL START FINISH START INTER FINISH TRAINING SPLIT SPLIT LAP JUMPING amp TAG Heuer Timing Blue course start on input 1 Blue course finish on input 2 Red course start on input 4 Red course finish on input 3 Manual numbering for the start and automatic number for the finish Blue course finish on input 1 Red course finish on input 4 Inputs 2 and 3 are not used Penalty or time difference needs to be entered for each run Manual numbering for finish Start on input 1 Finish on input 4 Inputs 2 and 3 are not used Automatic numbering on start and finish Start on input 1 Intermediate and or speed on inputs 2 and 3 Finish on input 4 Automatic numbering on start and finish Intermediate times with manual numbering by default Start on input 1 1 intermediate on input 2 2 intermediate on input 3 Finish on input 4 Automatic numbering on start intermediates and finish 4 a
37. ll be implemented for each N competitors 0 000 for the winner of the 1st run and 0 698 for example for the competitor who faces the winner on the opposite track amp TAG Heuer Timing Page 34 49 16 5 TRAINING Mode 16 55 10 740 16 55 12 720 1 98 16 55 15 315 TRAINING 4 57 RUN N 01 16 55 17 332 6 59 PRECISION 1 100 SEC 1 16 55 31 426 FREE MEMORY 26500 2 16 55 35 343 DATE lt JMA gt 04 12 07 1 3 91 TIME lt HMS gt 16 5 30 3 16 55 37 296 KKKKKKKKKKKKKKKKKKKKKKKKKKKKkKk 2 5 87 16 53 35 120 4 16 55 39 643 16 53 38 190 R lt 2 gt 8 21 3 07 1 6 53 40 900 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk 5 78 RUN RANKING N 01 Ranking of the best 16 53 43 585 times made in run 1 8 46 1 5 2 1 1 0 53 54 1 TI KKKKKKKKKKKKKKKKKKKKKKKKKKKkKkKk 16 53 56 733 2 55 KKKKKKKKKKKKKKKKKKKKKKKKKKKkKKkKk 16 53 58 721 LISTING RUN N 01 Times listing made by 4 54 COMPETITOR 1 N 1 in run 1 16 54 03 066 lt 8 88 1 1 6 54 20 1 68 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk 2 16 54 24 854 1 4 68 kkkkkkkkkkkkkkkkkkkkkkkkkkkkk 1 16 54 20 168 LISTING RUN N 05 Listing N 5 2 16 54 24 854 COMPETITOR 5 1 16 54 49 362 2 16 54 53 371 1 4 1 4 00 2 4 3 1 60 54 56 7 1 0 KKKKKKKKKKKKKKKKKKKKKKKKKKKKkKk 2 1 34 4 16 55 00 080 lt 10 71 This timing mode requires a minimal amount of manual input N E1 if the competitor N proposed on the Start is incorrect N R 0 if competitor aborts the run Example N 3 starts and aborts the run after the 1 intermediate amp
38. nction Recall 8 8 Identify a competitor 8 9 Disqualify Re qualify a competitor 9 Keyboard shortcuts 10 Special characters memorized printed and sent to the PC 11 Special function RESET CP 545 12 Mass Start or Group Start GRP 12 1 Start with a timing impulse 12 2 Start a defined time 13 Changing the paper roll 14 Autonomy Batteries 15 Information about Timing Modes 16 Example of Timekeeping sessions 16 1 SEQUENTIAL Mode 16 2 NET TIME Mode 16 3 PARALLEL SEQUENTIAL Mode 16 4 PARALLEL DIFFERENTIAL Mode 16 5 TRAINING Mode 16 6 Example Jumping Mode 16 7 Example Jumping Jump Off 17 Download a new version of Software and or language 18 RS232 and Ethernet Protocol 19 ETHERNET LINK CONFIGURATION 19 1 Configuration of your PC IP address 19 2 In SKI PRO MSPORT PRO etc 19 3 Ethernet connection test 20 Flow Char Main Menu 21 Flow chart of Run Menu 22 To opa run menu 23 Technical specifications 24 Pin out 25 Accessories amp TAG Heuer Timing Page 3 49 1 Introduction Building on TAG Heuer Professional Timing s legacy of evolution and innovation in timing equipment the brand has developed a new version of our famous Chronoprinter The CP 545 version offers outstanding precision reliability and simplicity to the user with new features such as a USB connection for easier communication with all PCs a larger internal memory and new integrated timing modes such as jumping for equestrian event
39. ng or unwinding itself Press to stop printing To remove a finished paper roll Pull from the centre of the paper roll backwards to extract it as well as the paper that is still engaged in the printer To insert a new paper roll o Unroll a few centimetres of paper until its surface is clean Cut it in a clean perpendicular fashion o Putthe paper roll into the cradle Insert the paper edge under the cylindrical driver bar Maintain a light pressure on the paper while pressing the paper feed button 1 Make sure the paper is going in straight Place the paper roll in its compartment and push it downwards You will feel a click as soon as the paper roll has found its housing To extract a paper roll partially started o Rotate the paper roll to loos a little bit of the paper o Extract 3 to 4 cm of paper o Firmly hold the unrolled paper with your index finger and thumb on each side and pull it vertically out amp TAG Heuer Timing Page 25 49 14 Autonomy Batteries Use good quality NiMH batteries for best results The chart below assumes timing impulses and printing happening every 6 seconds The CP 545 is delivered with Energizer batteries 0 C 32 F 20C 68 F Battery delivered with CP 545 Sanyo 2 500 11 000 ref TAG Heuer STHAANIMH impulses impulses Use in low temperatures The CP 545 is able to print on temperatures as low as 25 C Whenever possible use the external power supply to extend
40. nt each impulse on Input 1 will be displayed on the LCD and printed You have 5 sec to validate this time o If the time is not validated you will be able to see it again on the function Recall R o Ifyou validate the time it is used for the next calculation From this point you are allowed to add points remove points and validate the next impulse on Input 4 8 4 Mode Jumping 2 Phase Jumping SNG Phase The sequence for this mode is similar as the Jumping mode The normal sequence for this Timing Mode is Start Count Down Input 3 will start the session for a new competitor Start Race Input 1 Jump off Input 2 Finish Race Input 4 The sequence has to be respected Start Count Down Input 3 If the count down 0 it will validate the competitor from Next competitor to Competitor on Run From this point each impulse on Input 1 will be displayed on the LCD and printed You have 5 sec to validate this time o If the time is not validated you will be able to see it again on the function Recall R o Ifyou validate the time it is used for the next calculation From this point you are allowed to add points remove points and validate the next impulse on Input 2 Jump Off In Timing Mode Jumping 2 Phase you have two possibilities o The competitor received points penalties in this case the software will not authorize you to go further and the ranking will be calculated o The competitor receive
41. of those 3 Jumping Modes 5 7 Jumping Parameters 5 7 1 Set Count Down Set the count down before the start signal 30 or 45 sec If countdown is not required you set to 0 If setting to 0 each competitor has to be validated by pressing input 3 prior manually 5 7 2 Set Race Time Ph1 Set the Time limit for Phase 1 sec If the value is set at 0 no time penalties will be added 5 7 3 Set Race Time Ph2 Set the Time limit for Phase 2 sec If the value is set at 0 no time penalties will be added 5 7 4 Set Time P Ph1 Set Penalty in Ph1 wh time limit is exceeded 0 25 pts sec 5 7 5 Set Time P Ph2 Set Penalty in Ph2 wh time limit is exceeded it is possible to set the points penalties time example 0 25 pts 1 sec or 1 00 pts 4 sec 5 7 6 Set Pause Penalty Set a default Time Penalty if pause is requested sec amp TAG Heuer Timing Page 10 49 5 8 Parameters 5 8 1 Precision The timing PRECISION which can be selected at start up or assigned by default refers to the race results Two calculation modes are available NET TIME calculation REAL TIME calculation Ex with a result to 1 100 sec Ex with a result to 1 1000 sec Start Time N 121 12 34 56 136 Start Time N 121 12 34 56 136 Finish Time N 121 12 35 59 354 Finish Time N 121 12 35 59 354 Result 1 03 21 Result 1 03 218 The last digit of the calculation is truncated The print of time sure as result will be the same at
42. one or several un assignments were made by error To disable auto numbering at Start intermediate or finish Start times intermediate or finish times are memorized without competitor N The unassigned times can be recalled with RECALL for re identification The user has the opportunity to enter and verify or amend the competitor number before the data is transmitted to the printer RS232 USB and Ethernet port Recall not possible when option activated RECALL function to recall all memorized times that are unassigned or not identified for identification with a competitor N or with 0 to cancel C Recall of a competitor N to be modified a cancelled The time of a competitor N can th be modified or unassigned Recall the time for a new identification or to cancel it with 0 To disable auto numbering and direct access to RECALL for an immediate identification of the unassigned times received Ranking of a single run or of the addition of two or more runs amp TAG Heuer Timing To abort a competitor N DNF Quick action to cancel the start time of a competitor C Warning The cancelled times C with N R 0 are memorized but can t be recalled If you made a mistake it s necessary to insert the missing Time of Days manually via menu To disqualify a competitor N DSQ Quick action to cancel both the start and the finish times of a competitor Note Normally a disqualification is the function of a ra
43. order or in reference to a previous run ranking order or BIBO Manual enter the competitor s N E1 E4 normally before a timing impulse is received Inputs Status Selection of Inputs and their timing info functions into transmit received for each Input Three statuses A Transmit Cu Close de Received The default status of the input is as follows after switching off the CP 545 i 8 N N E1 E2 E3 E4 The inputs are reported as Transmit Example CP 545 A records Starting Time CP 545 B records Finish Time Download the Start time from CP 545 A into the CP 545 B for the net time calculation and from CP 545 B into the CP 545 A Configure the Input as follows CP 545 A Start CP 545 B Finish E2 E3 E2 E3 The input s status should be specifically programmed wh several CP 545 s need to communicate together via RS 232 or with GSM Docking station Thus each Chronoprinter will be able to receive recorded information at the Start and Finish point LCD Contrast LCD scre Backlight adjustment with A plus W less and validate with 30 is the default setting LCD Backlight Adjusts the brightness of LCD Backlight 100 is the default setting with an external power supply connected 30 is the default setting wh running only on internal batteries It is recommended to set the value at 0 during daylight conditions to guarantee the best internal battery life Lighting Off Time
44. rk Chapter gt CloseaRun Yes No gt Ranking gt Rankarun List of runs gt Listing Enable in Training and SPLITLAP mode gt Listing Enable in Training and SPLITLAP mode List of Run gt Still in Run gt Duplicate Select Input E1 E4 gt Insert time Select Input E1 E4 gt Speed 5 9 gt m sec Speed 1 to 4 gt Kmh Start Input n gt Miles h Finish Input n gt Knots Distance gt Jumping Parameters only in jumping mode 5 7 Count Down Time Ph 1 Time Pen Ph1 Time Ph 2 Only in Jumping 2 phases and Sng Phase Time Pen Ph2 Only in Jumping 2 phase and Sng Phase Pause penalties gt Parameters 5 8 gt Precision 1 sec 1 10 sec 1 100 sec 1 1 000 sec 1 10 000 sec 1 100 000 sec gt Locking Time Input 1 to 4 From 0 01 to 9 99 sec gt Numbering Input 1 to 4 Automatic Manual gt LCD Contrast A plus VW less gt LCD Backlight A plus Y less gt LCD Delay A plus Y less gt LCD Time OFF A plus VW less gt LCD Time display A plus Y less gt Beep ON OFF gt RS232 gt ToPC Baud Rate gt To HL960 990 Display Bodet HL970 Running Time Time of day Display OFF gt To HL970 980 Protocol THDISO8 Running Time Time of Day Display OFF Advertising 1 to 16 gt To ALGE Protocol ALGE Baud Rate gt Ethernet Std Connexion User Connexion gt Battery Type No Rechargeable NIMH Charge enable amp TAG Heuer Timing Page 45 49 NIMH Charge disable gt Language French English Italian German Spanish Russian gt
45. s In addition the new CP 545 is now available with rechargeable NiMH batteries with our standard power supply 2 The Keyboard ON OFF Power ON Hold ON down for 5 seconds to turn power ON Power OFF Press F and follow the instructions on the LCD display F Menu To enter or to exit the menu and sub menus A UP and DOWN keys to explore the menu and to scroll through the unassigned memorized y times DOWN key to deactivate the Automatic numbering of the channels lt ENTER to confirm menu selection time date or competitor number in the RECALL function R RECALL to access the unassigned memorized times of a channel for identification with a competitor number Direct times identification is also possible ERROR to cancel a wrong number you entered or to confirm an option Interruption of the printing Numbering of forerunners with N 0 9 Numerical keyboard to enter a time the date a competitor number or a distance E1 E4 To confirm a competitor number for one of the channels False START INTER or FINISH and confirmation of a channel deactivation W E1 E4 or gives opportunity to enter and verify competitor bibs A E1 E4 1 4 Manual keys for timing impulses or start the time synchronisation Green 1 4 Manual keys to unblock and block the External inputs Input 1 4 Red Inputs are blocked wh a black bar is shown on the LCD display Warning The manual timing keys 1 to 4 do not g
46. sh with its actual rank 15 45 04 569 15 45 04 889 15 45 12 545 7 97 15 45 12 785 7 88 15 45 27 472 15 45 27 996 15 45 35 603 RED lt 3 gt 8 13 5 2 15 45 37 651 BLUE lt 3 gt 9 65 kkkkkkkkkkkkkkkkkkkkkkkkkkkk RANKING RUN N 01 C a om ee Blue course competitor ranking Red course competitor ranking ON A JLVN W m Dan Y kkkkkkkkkkkkkkkkkkkkkkkkkkkk RUN N 01 CLOSED Close the run menu amp TAG Heuer Timing Page 32 49 TE PARALLEL SEQ RUN N 02 ADDED TO RUN N 01 PRECISION 1 100 SEC MEMORY FREE 26500 DATE lt JMA gt 04 12 07 TIME lt HMS gt 15 44 24 11 15 46 34 070 1 15 46 36 390 15 46 42 230 8 16 16 80 15 46 42 770 6 38 13 09 15 46 51 110 15 46 51 140 15 47 00 110 15 47 15 525 15 47 16 617 15 47 21 978 5 36 15 01 15 47 23 449 7 92 16 05 COUrse General ranking with Run 1 and 2 added amp TAG Heuer Timing Run 2 ranking Open run N 2 added to run N 1 The competitor N started on the Blue course will start on the new run in the Red course They will be pitted against those who have made runs on the Red course They will leave on the Blue N 3 Starts on the Red course N 4 Starts on the Blue course Time of run N 2 for the competitor N 2 Total time General of runs 1 2 for the N 3 with his her actual ranking kkkkkkkkkkkkkkkkkkkkkkkkkkkk GENERAL RANKING RUN N 02 01 kkkkkkkkkkkkkkkkkkkkkkkkkkkk
47. uarantee timing precision Only two simultaneous impulses can be processed at a time from the manual keys amp TAG Heuer Timing Page 4 49 3 Rear Connectors INPUT Inputs for timing impulses 1t04 Working contacts without potential short circuit or op collector Ex Manual contactor HL18 photocells HL2 31 HL2 35 Start Gates H7 1 HL7 3 radio receiver HL610 HL620 etc Respect the correct polarity POWER For an external power supply HL545 1 adaptor 110 220Vac 12 Vdc or 12Vdc batteries via HL520 17 connection cable USB Bi directional communication with PC Upgrade to the latest firmware for CP 545 Baud rate automatic Note The USB port is not suitable for transmitting data to LED display or modem RS232 Bi directional communication with a PC ONLINE or OFF LINE with selectable baud rates 2400 4800 9600 Bds default and 32k or 56k Bds Upgrade of the new software for CP 545 Timing data transfer from one CP 545 to another With Display Mode this allows standard communication with TAG Heuer or Alge displays boards ETHERNET Bidirectional communication with a PC or a Network LAN with other CP 545 PC display board or printer amp TAG Heuer Timing Page 5 49 4 Quick operation guide The exceptional performance of Chronoprinter CP 545 is guaranteed with its simplicity of use the hallmark of TAG Heuer timing philosophy 4 1 Battery installation amp replacement rechargeable NiMH batt
48. ule e A GPS satellite module which allows you the automatic setting of the CP 545 to the exact time of day and the monitoring of the time base precision relative to the GPS master during the entire timing sessions e An Input and Output MasterSlave which allows you the connection and synchronization of several CP 545 s together In this way the same time s of day is guaranteed on several devices e A Top Minute impulse output is available for synchronizing any timing devices GSM Module e AGSM module that gives you the possibility to transmit the timing information by wireless telephony Docking HL545 BATT e Include an internal battery Docking HL545 GSM This docking station is recommended for an absolute precision and professional timing and allows you to communicate betweseveral systems in a difficult environment Include e Internal battery e GPS module e GSM module amp TAG Heuer Timing Page 48 49 ell TAGHeuer PROFESSIONAL TIMING TAG Heuer PROFESSIONAL TIMING 6A Louis Joseph Chevrolet 2300 la Chaux de Fonds Switzerland Tel 032 919 8000 Fax 032 919 9026 info tagheuer timing com www tagheuer timing com amp TAG Heuer Timing Page 49 49
49. ut 1 Validate time competitor N 12 Impulse received on the CP 540 and not validated Finish phase 1 input 2 Input 2 validate time competitor N 12 Result of the Competitor Value of the count down On phase 1 Point Pause penalty Time Penalty Net time Finish phase 1 input 2 Input 2 validate time Result of the Competitor Value of the count down On phase 1 Point Pause penalty Time Penalty Net time On phase 2 Point Pause penalty Time Penalty Ranking Net time 12 4 8 sec 0 points 0 sec 0 00 points 88 96 sec 12 2 2 sec 0 points 0 sec 0 00 points 88 96 sec 0 points 0 sec 0 00 points 8 57 12 sec Page 38 49 17 Download a new version of Software and or language Program downloads and new releases of CP 545 software are available Free of Charge on our website www tagheuer timing com For this operation you need to have e USB cable HL545 3 or RS232 cable Sub D9p RJ11 HL545 10 e Computer e The software FirmwareManager exe upper th version V10 Procedure 1 Copy the software FirmwareManager exe onto your hard disk 2 Power the CP 545 with an external power supply The CP 545 is off 3 Connectthe USB or RS232 cable HL545 10 to the PC and the CP 545 4 Run the software FirmwareManager exe upper th version VA01 HE CP540 Firmware Download V1 0 3 TAGHeuer PROFESSIONAL TIMIN www tagheuer timing com