1. OSRAM a Description Purpose and application Presence sensor light and motion sensor Operating instructions IX 2009 DUO_ba0909en_we1 01 indd OSRAM GmbH Kunden Service Center Customer Service Center CSC Steinerne Furt 62 86167 Augsburg Germany Tel 49 0 1803 677 200 kostenpflichtig charges apply Fax 49 0 1803 677 202 www osram com www osram de 4008321496355 The DUO sensor detects the presence of persons and mea sures the intensity of ambient light The sensor is designed for installation on ceilings or in lumi naires using a T5 T8 holding clip and is ideal for the expansion of existing electrical installations The following application types are available depending on how the sensor is connected see the connection diagram in the fitting instructions e Alternative 1 One sensor switches a load area by means of light and or motion detection e Alternative 2 One sensor switches a load area by means of light and or motion detection Additional motion detection sensors are used to expand the detection area slave mode Function The sensor operates fully automatically and the values detected by the sensor motion light value control the switching behaviour on the basis of the parameters set by the user The measured light value depends on the incidence of daylight the artificial lighting and the properties
2. checking the function keep an adequate distance to the sensor to avoid altering the luminance measurement e While the setpoint is being changed the switch off delay time is set to 10 seconds for one minute if there is too much light Turn the adjusting screw D on the sensor to the required setting e Default setting Position 10 automatic mode e Position 1 9 30 60 100 150 200 250 300 400 500 lux e Position 10 all the way to the right Automatic mode The sensor independently defines the switch on and switch off thresholds based on the measured values Adjusting the switch off delay time Switch off delay time if no motion is detected Turn the adjusting screw E on the sensor to the required setting e Default setting Position 5 10 minutes delay time e Position 1 all the way to the left Test mode for checking the function Switch off delay times no motion or sufficient daylight are reduced to 10 s e Position 2 9 1 3 5 10 15 20 30 45 60 minutes Page 3 of 4 58 5 70 5 47 33 Technical data Operating voltage Fuse Power consumption Maximum total line length Switch output Switch output load capacity Detection area Installation height Switching hysteresis Operating temperature Protection class Protection type Weight Dimensions L x W x H 220 240 V 50 60 Hz no DC operation External 6 A 10 A Switched on Approx 1 W Switched off App
3. he mains voltage returns the lighting is switched on Function of the DIP switches Function DIP switch F Motion detection Activated Deactivated Brightness control Activated Deactivated Switch offsignaling Activated Deactivated 3 OFF I l E DIP switch 4 has no function only used for production purpo ses Default setting state at delivery DIP switches 1 2 are activated DIP switch 3 is deactivated Page 2 of 4 Operation cont Activating motion detection and brightness control Motion detection and brightness control can be activated individually or jointly Motion detection To activate DIP switch 1 ON To deactivate DIP switch 1 OFF Brightness control To activate DIP switch 2 ON To deactivate DIP switch 2 OFF Note When DIP switches 1 and 2 are set to OFF the sensor is in slave mode expansion of the motion detection area see the connection diagram in the fitting instructions Activating switch off signaling Precondition Motion detection is activated DIP switch 1 ON The switch off is signaled by a brief flash of the lighting 30 s before the switch off delay time expires if no motion is detected To activate DIP switch 3 ON To deactivate DIP switch 3 OFF Specifying set value for brightness control Note e Make the setting while there is a low incidence of daylight e Do not cover the sensor while making the setting e When
4. of the surface light dark The following parameters can be set e Switch off delay time if no motion is detected e Light value e Function mode Design The sensor is made up of the following components Upper section of housing e Motion sensor A e LED B e Light sensor C e Adjusting screws Setpoint for brightness D Switch off delay time E e DIP switch on the back F Lower section of housing e Connections G L N Supply lines Switch contact Parallel circuit for joint motion detection LED display The LED B indicates the operating state of the sensor LED Operating state Green Switch contact OFF sufficient daylight Orange Switch contact ON artificial lighting required Flashes slowly Motion detected green orange orange normal mode green slave mode Flashes rapidly Setpoint for brightness was exceeded orange Reduce the setpoint and check the light conditions at the installation location Off Slave mode see the connection diagram in the fitting instructions Page 1 of 4 Symbols Q Luminaire on Luminaire off Ld Automatic control principle Precondition Motion detection and brightness control are activated Luminaire OFF Artificial light required yes Luminaire ON Luminaire ON Luminaire OFF Luminaire OFF 60 min Q gt 5 min Artificial light required l no After the mains voltage is applied and t
5. rox 0 7 W 100 m Floating contact internal relay make contact Resistive load 10 A 250 V AC 6 A 30 V DC Ohmic lamp load 5 A Inductive load 5 A 30 x single lamp ECG 18 W 20 x two lamp ECG 18 W 30 x single lamp ECG 36 W 20 x two lamp ECG 36 W 20 x single lamp ECG 58 W 10 x two lamp ECG 58 W Max 12m Max 5 m ideal 2 5 3 m Approx 15 0 C 50 C II IP 20 Approx 150 g 58 5 x 70 5 x 47 mm Dimensioned drawing Conformity with the relevant EU directives is confirmed by the CE symbol Page 4 of 4
Download Pdf Manuals
Related Search
Related Contents
Untitled Samsung GT-I8530 Vartotojo vadovas L`importance du lien de parenté : recueil, codification et Série 200 BIOLOG 3000i ™ User Manual - Frank`s Hospital Workshop Meshgraft™ II - Página principal de Zimmer RÉSEAU D`AFFICHAGE GUIDO Sony CDX-GT25MPW Operating Instructions 3b Thionville liste emplacements réservés Q5K-YSK-008-L06 Copyright © All rights reserved.