Installation Manual – 5355A-900 Rev M ProxPro Reader
Contents
1. Reverse Voltage Protection gt Input Voltage maximum data 0 1 lines gt Input Voltage maximum interface lines VVVVVVVV Option D Buffered Direct Connect Keypad gt Operating Voltage Range DC gt Input Voltage Maximum Data 0 1 Lines gt Input Voltage Maximum Interface Lines Operating Parameters Excitation Frequency Duty Cycle alternate power level rate Read and Report Speed 26 bit Wiegand Card Maximum Cable Distance to Host LED Type LED Operation host control of red green Beeper Operation host control LED Control default Beeper Control default Anti Pass Back Delay default Wiegand Data Pulse Widths default Wiegand Data Interval default Clock Data bit time Clock Data strobe width Clock Data clock strobe is valid VVVVVVVVVVV VV VV VV 5 0 inches 8 0 inches 5 5 inches 5 5 inches 9 0 inches 6 0 inches 12 7 cm 20 3 cm 14 cm 14 cm 23 cm 15 2 cm ann ON NT Designed for listing under UL 294 Standard for Access Control System Units 30 C to 65 C 22 F to 150 F 40 C to 85 C 40 F to 185 F 5 to 95 non condensing 04 g Hz 20 2000Hz 30g 11mS Half Sine UL Recognized Lexan Polycarbonate 11 30z 310gms Linear type recommended 10VDC 28 5VDC 90mA 155mA UL 294 YES 28 5VDC 28 5VDC 10VDC 26VDC 14VDC 14VDC 125KHz 20 60mS period 175mS 500 feet 152 meters Bi colored Red Green 5V on LED control line
2. connects to the Keypad board inside the ProxPro to the Host via P2 P2 is a 7 position terminal strip Switch 1 4 SW1 4 should be switched to the off position The reader will then NOT process the keypad data and it will be decoded by the host in 2 of 7 format The keypad has a matrix of contacts corresponding with the matrix of keys The contact outputs are wired to the seven terminals of P2 The seven terminals are called P2 1 thru P2 7 and provide the 2 of 7 decode of the buttons When a key is pressed the button closes two contacts that pull 2 lines to ground This results of the key entries are in the table below The reader and the host that is scanning the keypad will require a common signal ground The connection is to be made on either pin 2 power supply ground or 5 Data Return of TB1 of the ProxPro This method of interfacing the keypad requires additional processing by the host These include the de bouncing of the keys decoding of the keypad timing between key entries as well as others depending on the Host The 2 of 7 format is available on the ProxPro 5355XXKXX versions Key Pad Data Table 2 of 7 Terminal Number Seat P2 1 P2 2 P2 3 P2 4 P2 5 P2 6 P2 7 a a oa Bcc os ea aa a ee i HE cl oe jee STAs 8 SAS SEO THE a BO HH ea RI He tre aie EH HI represents a voltage of 5 volts in reference to the ProxPro ground LO represents the ProxPro ground Note The system is to be used on a single point
3. ground system S Version Direct connect keypad Scanning 3 X 4 Matrix format The ProxPro reader is available with a 3 x 4 matrix keypad The keypad is independent of the ProxPro reader and only provides the connections to the keypad This mode requires a separate cable to be supplied that connects to the Keypad board inside the ProxPro to the Host via P2 P2 is a 7 position terminal strip The following is the table for the contact closures HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 8 of 11 This table indicates the connection between the connector pins when a key is pressed For example if key 3 is pressed P2 5 is connected shorted to P2 1 This is available on the Serial ProxPro 5355XXSXX versions Columns P2 6 D Version Bufferd Direct connect keypad Scanning 3 X 4 Matrix format The ProxPro reader is available with a 3 x 4 matrix keypad The keypad is independent of the ProxPro reader and only provides a voltage output from the keypad This mode requires a separate cable to be supplied that connects to the Keypad wiring to the host This method of interfacing the keypad requires additional processing by the host This includes toggling the select low line to ground to enable the keypad debouncing of the keys decoding of the keypad voltages timing between key entries a
4. is sent on data lines N A for D version Green LED Control off The green LED is enabled when a card is read Beeper Control on The beeper is enabled when a card is read Hardware Identity on Identifies the unit to be Wiegand Keypad Option Notes This section of this document describes the keypad interface The keypad has twelve keys four rows by three columns The characters 0 to 9 and are arranged the same as a standard telephone keypad There are two methods for interfacing to the Keypad The first configuration K version internal keypad processes the keypad entries in the reader and then transmits the data to the host system via the Wiegand data lines The reader outputs each key as an ASCII encoded hexadecimal digit The decoding of the message sent through the Wiegand interface is the only processing required of the host system The user interface has been implemented in the most generic fashion to give the integrator the most flexibility HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 6 of 11 The Second configuration S version direct connect keypad the host must scan the keypad directly using a separate cable K Version Internal keypad processing Parity and Length options must be factory configured Contact customer service to enable these options Parity Option Th
5. start the sequence from the beginning Keypad Message The keypad message follows a basic format The entries are transmitted in the hexadecimal representation When parity is added the message format mimics the standard 26 bit Wiegand format The key that is pressed is represented in Hexadecimal with represented by A HEX and represented by B HEX 0 0000 4 0100 8 1000 1 0001 5 0101 9 1001 2 0010 6 0110 1010 3 0011 7 0111 1011 Example without parity AAAA BBBB CCCC DDDD KKKK AAAA The first key entered BBBB The second key entered KKKK The eleventh key entered the maximum Example with parity A message that has a fixed number of key entries set to 4 and the parity option included P AAAA BBBB CCCC DDDD P A the first key entered B the second key entered C the third key entered D the fourth key entered P Parity Bits HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 7 of 11 The whole message is similar to the Standard 26 Bit Wiegand formatted message The format consists of two parity bits at the opposite ends one odd and the other even Each parity bit covering exactly one half of the message PXXXXXXXKX XXXXXXXXP EXXXXXXXX XXXXXXXXP Keypad Scanning 2 of 7 K version This mode requires a separate cable to be supplied that
6. when controlling the red and green LED Alpha 1296 C or equivalent 7 conductor cable is required when both green and red LED s are controlled by the Host and the power supply and Host ground are separate Alpha 1297 C or equivalent A 22 AWG twisted pair shielded stranded cable is often required for the tamper switch Follow the recommendations of the manufacturer of the Host system If the tamper input is a supervised input the end of line resistors may be mounted in the enclosure Use extreme care and shield any bare wire from the printed circuit assembly and its components The inner diameter of the cable fitting will accommodate a cable with an outer diameter of 300 inches nominally Connect cable shield by connecting drain wire to TB1 2 ground Leave foil and drain wire disconnected at host end of cable by cutting them off at the end of the cable jacket When using the Buffered Direct Connect ProxPro with a 20 conductor cable DC and Power Red and White Red wires must have a common connection to the host DC power supply The two ground wires Black and White Black must have a common ground connection to the host DC power supply HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 4 of 11 P1 CAI 123 1 DC 2 GND 3 DATA 0 FERA I 5 00 127mm 5 DATA RTN 6 Gre
7. 5V on beeper line internal single Beeper enabled 1 second 40uS 2mS 1 5ms default bit time 3 33 of bit time default 500us 1 5ms one clock cycle min after card present is Asserted data is valid 10us min before the negative edge of clock strobe card present returns to the high level 50 ms max after the last clock strobe HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 100f11 Product Configuration Ordering Options Customer Custom Artwork or Firmware Number ee 1 through 9 A through Z ET Customer Custom Number se Configuration Options 00 standard Standard Hardware Options N None K Standard Keypad internal or 2 of 7 S Direct Connect Keypad 3 x 4 type D Buffered Direct Connect Keypad 3 x 4 type Pie Color G Gray B Beige Model Number Suffix eee i Model Number 5355 ProxPro Wiegand Model Number 5358 ProxPro Clock Data Final Assembly Number 5355 300 XX Changes with Revisions NOTES THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES ALL LOCAL STATE AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 11 of 11
8. HID CORPORATION Installation Manual 5355A 900 Rev M ProxPro Reader Wiegand Clock and Data 5355 8A HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 1 of 11 ProxPro Reader Wiegand Clock Data Installation Manual System Overview The ProxPro reader is a self contained proximity reader The two piece polycarbonate enclosure has an rubber Gasket that seals the pieces together and a cable fitting that seals the cable entry The water resistant unit is approved for outdoor use The enclosure is designed to fit on a single gang electrical box A Bi color LED and audible tone enhance user feedback A tamper switch feature is available that will alert the Host when the enclosure is opened An internal DIP switch makes the configuration of the outputs audible tone keypad and LED control options simple Installation of the ProxPro reader consists of mounting verifying the DIP switch settings setting a tuning jumper and connecting the cable to the Host Operation Access Cards may be presented to either the front or the back of the reader Optimum read range is achieved when the access card is presented face on and parallel to the reader face The LED is normally controlled by the internal reader firmware Alternatively the LED can be controlled by the access control host panel When the LED is co
9. double gang electrical box or drill the appropriate mounting for 6 fasteners If mounting to a metal surface drill two 7 64 109 inch holes and use the enclosed self tapping screws for mounting 2 Route the interface cable from the reader and or power supply to the Host 3 Prepare the cable by cutting the cable jacket back 2 two inches and strip the wires 1 4 inch Tinning the wires is not required 4 Pry off the center face plate by placing a thin blade into the grove that outlines the face of the reader Use care to avoid scratching the surface of the reader The face plate is attached to the reader by friction only The screws that hold the enclosure pieces together will be exposed Loosen the four screws to open the enclosure the enclosure screws are captive to the cover 5 Install the cable fitting on the rear of the reader Feed the cable through the cable fitting tighten the fitting nut so the cable jacket is flush with the printed circuit board Dress the cable conductors and connect the reader to the Host according to the terminal descriptions in the dimension diagram and wiring table The descriptions are on the PCB guard in the reader Connect the drain line of the shield to terminal 2 Power Supply Ground Terminal 5 Data Return is to be connected to the ground of the Host if the power supply HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail ww
10. e default does not included parity in the data message When the parity option is enabled parity is added to the total message independent of length The parity coverage is diagrammed below Each parity bit covers exactly one half of the message PXXXXXXXX XXXXXXXXP EXXXXXXXX XXXXXXXXP Length Buffer keys Option The length option chooses the number of key entries that will be buffered before the message is sent to the host The maximum number of entries is 10 with parity and 11 without parity When the option is set for multiple entries the reader has a five 5 second timer that will clear all entries after five seconds has expired between entries The length option requires the user to enter the programmed number of key entries Upon completion of the last key entry the message is assembled and sent Parity is added if the option is set This requires the system integrator to configure the reader for the number of key entries before installation User Interface The user is able to press keys at any time Card reads and key entries are independent of each other the user is not required to follow any sequence unless specified by the system integrator The reader is equipped to give the user audible visual and tactile feedback when a key is pressed The amount of time is 5 five seconds between key entries when the multiple key entry option is used If the time expires between key entries all keys entered are cleared and the user must
11. en LED 3 28 83 3mm 7 Red LED 8 Beeper 9 Hold 10 COM 11 Tamper TAMPER SW 1 n o 3 n c 00000000000 QIZZ22222772 LHL 1 00 25 4mm t Dimension Drawing Actual Size DIP Switch Settings Switch 1 HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 5 of 11 Switch 1 1 Hardware Identity When set in the on position the unit is configured for Wiegand interface The off position configures the unit for Clock and data interface Switch 1 2 Audible Tone Control The Audible Tone Beeper may be enabled or disabled to sound when an access card is read When enabled the audible tone is sounded when the a card is successfully read When the Beeper is disabled the only method to activate the Beeper is to use the external Beeper control line The Beeper will turn on when the control line is switched to ground Switch 2 in the on position enables the audible tone the default Switch 1 3 Green LED Control The Green LED can be configured to turn on or not turn on when an access card is read Switch 3 in the off position selects the Green LED to be turned on the default Switch 1 4 Keypad Operation The keypad inputs may be processed by the reader or may be connected directly to the Host When the keypad inputs are processed by t
12. er plate Otherwise the jumper should be between pins 2 and 3 the default position 10 After wiring the Reader and power supply the Reader is ready to be tested Power up the Reader and the LED and Beeper will flash and beep 3 times in a sequence of two short delays and one long delay This indicates that the micro controller unit is working properly If the switches have been set for external control only the Reader will 3 shorts and a long Present an ID card to the Reader and the LED should momentarily turn green indicating a read of the card If the Reader LED is controlled by the Host refer to the Host description of the LED operation 11 Replace the top cover and face plate Standard Wire Connections TBi es el Ba a E JAZZ RETRO E DC Ground Data0 Data1 Shield Green Red Beeper Hold Tamper Tamper Data Clock Ground LED LED Card Common Select Present Red Black Green White Violet Orange Brown Yellow Blue Buffered Direct Wire Connections Option D Direct Wire Connections Option S Tee Rea oak re NE Drain Orange Brom HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 3 of 11 Cable Notes When using 5 conductor cable the power supply and Host must have a common ground voltage reference 6 conductor cable is required
13. he reader the reader scans the keypad and outputs the keypad entries over the Wiegand interface When the keypad is connected to the Host the Host determines which key is being entered Switch 4 is in the on position for the default mode the keypad inputs are processed by the reader Switch 1 5 Single Dual LED Control In Single LED Control the LED is Red When an access card is read the LED toggles Green and then back to Red Grounding the Green LED Control line will change the LED from Red to Green The reader maybe configured so the Green LED is externally controlled independently from the Red LED This is referred to as Dual LED Control When the Red or Green LED Control line is switched to ground the respective LED is turned on If both LED s are on the LED appears to glow amber Switch 5 in the off position selects Single LED Control the default Switch 1 6 and 1 7 Data Output Biasing The data outputs may be configured as open collector or biased at 5VDC through 1k Ohm resistors by the reader The default standard configuration is output biasing with switches 6 and 7 on Note When the outputs are configured as open collector the host panel should provide bias voltage at the panel inputs Default Setting Not used on Wiegand Data 0 Bias on The Wiegand data outputs are pulled up to 5VDC Wiegand Data 1 Bias on through a 1kOhm resistor Single Dual LED CNTL off Single Line LED Control KeyPad on The keypad data
14. ntrolled directly by the reader the LED normal state is red and indicates that the reader is ready to read an access card The LED turns green when the access card is read and the message is transmitted to the Host system When the reader is ready for another access card the LED returns to red The typical time the LED is green is 250 milliseconds The reader only controls the green state of the LED there is no amber LED state The operation of the LED may be controlled by the Host When the LED is host system controlled the LED and beeper operation may vary depending on the particular host software The LED may then exhibit a red green or amber color for certain status conditions as controlled by that host s software Parts List 1 ProxPro Reader qty 1 included 2 6 32 x 1 self tapping screws Type T or 23 qty 2 included 3 Installation Manual qty 1 included 4 Cable Fitting qty 1 included 5 Cable 5 conductor 22awg as required max 500 feet Alpha 1295 C or equivalent See cable notes 6 Cable 20 conductor 22awg as required max 500 feet Alpha 1299 20C or equivalent See cable notes 7 DC Power Supply 12V 100mA or 24V 120mA 1 Installer supplied 8 Inthe E U the recommended power supply is the Micro State Electronics Model PS 5 Installation Procedure 1 Determine an appropriate mounting position for the reader The reader drawing below is actual size and may be used as a template Install a single or
15. s well as others depending on the host This table indicates the voltage on the keypad wires when a key is pressed This is available on the Buffered Direct Connect ProxPro 5355XXDXX versions Buffered Direct Connect KeyPad Data Table Wire Colors Violet Red White White HI represents a voltage of 5 volts in reference to the ProxPro ground LO represents the ProxPro ground Notes 1 The system is to be used on a single point ground system 2 On the Buffered Direct Connect toggle Select Low White Yellow wire to ground to enable the above keypad outputs HID Corporation 9292 Jeronimo Road Irvine CA 92618 USA TEL 949 598 1600 800 237 7769 FAX 949 598 1690 Web page E mail www hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 9 of 11 ProxPro Reader Specifications Read Distance using ProxCard II Over all Operating Limits minimum 12VDC Non Metallic Mounting typical 12VDC Mounted on Metal typical 12VDC Overall Operating Limits minimum 24VDC Non Metallic Mounting typical 24VDC Mounted on Metal typical 24VDC Environmental Characteristics VVVVV V Operating Temperature Range Storage Temperature Range Operating Humidity Range Operating Vibration Limit Operating Shock Limit Enclosure Material Weight Power Requirements gt Power supply gt Operating Voltage Range DC gt Maximum Average Current 12V 24V gt Transient Protection all terminals gt
16. w hidcorp com ProxPro Reader Installation Manual 5355A 900 Rev M 2 of 11 ground is not common with the Host The opposite end of the drain line should be cut flush with the jacket and left disconnected 6 If the tamper feature is available on the Host connect the tamper switch using the connections recommended by the Host documentation The switch is a single pole double throw When the inner reader cover is removed the tamper switch is released The TB1 connections to the tamper switch are pins 10 and 11 Pin 10 is the common contact of the switch and pin 11 is either the normally open or closed Jumper P3 selects the contact of the tamper switch either the normally closed or the normally open contact The default position is P3 across pins 1 and 2 This selects the normally open contact on TB1 pin 11 If the normally closed contact is required move P3 across pins 2 and 3 Note normally open and normally closed refer to the Pin 11 status while the cover is removed The contacts are rated for 100mA at 35 VDC 7 Mount the base of the reader that holds the electronics to the gang box or surface using the two holes located on the center axis of the reader Two 6 32 x 1 inch screws are provided for mounting to a gang box or metal surface 8 Set the DIP switches according to the table in the section DIP Switch Settings 9 Place the jumper on P1 between pins 1 and 2 when mounting to a metallic surface or to a junction box with a metal cov
Download Pdf Manuals
Related Search
Related Contents
Manuel d` utilisation HP-12VC CS-12VC/VCT/TLS Resident Reviewers Project - Current consultations Groupe SEB USA - T-FAL Steam Generator 028043 User's Manual Channel selection Modbus Option Board MANUEL D`INSTALLATION ET D`UTILISATION POÊLES À KJX17, KJX17CL - Pdfstream.manualsonline.com Wiley Office 2010 All-in-One For Dummies Jun Copyright © All rights reserved.