USER MANUAL SECURITY INTERFACE IS 2
Contents
1. MAJORCOM USER MANUAL SECURITY INTERFACE SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM This interface allows the installation of a sound system that conforms to the EN 60849 European Safety Standard Switching of all sound areas in safety Adjustment of tone and volume of the evacuation message Control of the operation of the evacuation message Adjustment of the tone and volume of the emergency microphone if present Control of the links between the IS2 and the emergency microphone MAGPS if present Control of existing amplifiers and switching to the safety amplifier if present Note in order to comply with EN 60 849 there must be a minimum of two amplifiers Regular control of loudspeakers and circuits checking for short circuits open lines and proper earthing These checks do not cause any interruption to the modulation Possibility to start the evacuation by an NO or NC dry contact or by sending a continuous positive current between 24 and 48V Management of alert message Connection with the ES2 and ES4 units in order to increase the number of speaker areas The device is delivered with two end of line devices I Functions SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb
2. 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L w lt MAJORCOM 6 Economic Mode In certain cases you may need to reduce the level of electrical consumption of your installation Put the configuration switch 30 number 3 to ON The amplifiers will only emit from time to time It is advised to always stay OFF in order to check the system SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM e Only connect the mains power and the safety power at the end e Connect the normal sources to inputs 1 and 2 III Connections Pr ampli confort Sorties Entfes confort Sorties vers ampli Nb Modules secours Vers ERAT Confi tuuu 23 17 74 2 76 87 fuse Micro non CS UGA Ampli sec AI A2 OL Jooe L L_looo IOIILIOIL Reminder of wiring for a balanced input In the case of a balanced source Sortie source Entr e IS SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM In the case of an unbalanced source Sortie source Entr e IS e Connect the modulat
3. an extension unit that doesn t have a safety amplifier Ent es confort ers ampli 2 E m Vers module Nb Modules E 1 2 S Configuration gt AR OO fuse 24V fuse Micro NoynrCS UGA Ampli sec Al LI A2 O OU Joooe _jooo OWL AMPLIFICATEUR LIGNE 100V Sortie 100V D faut 24V DC Entr e AMPLIFICATEUR LIGNE 100V D faut fusible Entr e g B AMPLIFICATEUR LIGNE 100V D faut Sortie 100V fusible Utilis en secours 230V AC 24V DC Entr e i 1 O SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM e Connect the speaker lines to their respective sockets Ensure that the following points are carefully followed The COM socket of the IS device must be connected to the COM socket of the end of line device The 100V socket of the IS device must be connected to the 100V socket of the end of line device The MES socket of the IS device must be connected to the MES socket of the end of line device If this order is not followed then the device may break down or be destroyed Ent es confort e ampi oi Vers module Nb Modules E S Configuration 3 230V O O ae 30 24V fuse Micro CS BT UGA Ampli se
4. re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM II Configuration 1 Proper Earthing e This device has been designed to operate within safety installations However it is connected to the normal sound system music announcements by a pre amplifier If this is the case then there must be a check for the presence of correct earthing of the system e If there is no earthing of the system the earthing button 32 must be pressed in e If the pre amplifier is already earthed the earthing button 32 should be left out 2 Number of connected amplifiers e You must indicate the number of amplifiers connected to your system e If you only have one amplifier insufficient for complying with the EN 60 849 safety standard the configuration switch 1 30 should be in an OFF position top e If you have a second amplifier connected the minimum required for compliance with EN 60849 the configuration switch 1 30 should be in an ON position towards the bottom e If you have a safety amplifier connected to this unit in case of failure of one of the other two amplifiers the configuration switch 2 30 should be in an ON position towards the bottom Otherwise this switch must be off e For normal operation all the other switches must be off 3 Emergency Microphone e If an emergency microphone is
5. sec Al A2 s0 OF loce ei TOU IL Sortie 100V Sortie 100V fin Sortie 100V 230V AC fin Declehchement B Evacudtion RFL entr e d faut UGA Evacuation contact sec NO ou NF SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM e If you have extension units check the user manual for details of how these are connected together e Once all the modules are connected and configured See configuration above you can connect the mains power supply and then the 24V emergency power supply with the on the right Pr ampli confort Sorties coni nor t fort ies 8 ampli rs Ver module Nb Modules x pu fuse wompCS Ampli sec Al Li A2 12 OC 0090 C 1000 DLL AMPLIFICATEUR LIGNE 100V Sortie jv D faut 230V AC AMPLIFICATEUR LIGNE 100V Sortie jov D faut 230V AC tait AMPLIFICATEUR LIGNE 100V Sortie 100V fusible Utilis en secours 230V AC 24V DC T Entr e Distribution RFL UGA 230V AC SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 5
6. stopped at any time by turning the front panel to Arret Manuel or manual stop 8 The message stops even if the order coming from the Alarm Management Unit continues In the latter instance the message restarts if the key is put into position 0 5 Emergency Microphone Mode This mode can only be started by pressing the operation button on the MAGPS unit In this case normal modulation is cut The evacuation message is cut if it is being broadcast and the microphone transmits The red LED Emergency Microphone 18 is lit The volume 36 and tone 37 level of the microphone can be adjusted on the rear panel The message can be heard on the integrated speaker 1 which is adjustable on the front panel 2 Normal modulation returns when the button on the microphone is released If an evacuation alert is in process the modulation from the evacuation reader returns 6 Surveillance Mode When the system is neither in evacuation mode through the alarm management unit nor being used by the emergency desk microphone operational tests are carried out on fuses connected amplifiers speaker lines and extension units SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM When a fault is detected the fault is shown on
7. the front panel and a continuous beep is sounded by the base unit Press the reset button 9 on the base module for at least one second to clear the fault The beep stops If another fault appears the beep returns Reset etc If the system is no longer responding reset the complete system with the configuration switch 30 number 8 button by turning it on and off on the base unit Contact your reseller to check the installation V Area Extension If there are more than 2 speaker zones you can add up to 9 extension units To use these units please consult the appropriate user manual SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM VI Presentation of the device FACE AVANT E Aret manuel Desn manuel C tm 5 FACE ARRIERE e fi i ass a 60 6 6 fie Z p we pj m Nel o nre l oum e 6 1 Integrated speaker 26 Normal Inputs 2 Integrated speaker control 27 Modulation output to amplifiers 3 Normal sound volume control 28 Modulation output 0dB to safety amplifier 4 Switch to
8. 69 APE 524L MAJORCOM e If you are using an emergency microphone connect it Be careful to use the resistors on the sockets if you do not have this microphone Only use the MAGPS product not the MAGPE MAGPL or any other Ent es confort Sorties vers ampli secours Vers module Nb Modules 1 2 1 2 O O O O O ES Configuration 0 5 fuse 24V fuse Micro noynprCS UGA Ampli sec Al A2 L L_looo IOI LIOIL Terre SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 MAJORCOM e Connect the type of evacuation start according to the type of alarm management unit Cas d un syst me conforme EN 60 849 Ent es confort Sorties vers ampli Nb Modules secours Vers module an Ay peu fuse E 24V fuse Micro CS BT UGA Ampli sec Ll OL 1eooe AMPLIFICATEUR LIGNE 100V Sortie 100V AMPLIFICATEUR LIGNE 100V 24V DC Entr e AMPLIFICATEUR LIGNE 100V Sortie 100V 230V AC entr e d faut UGA Evacuation The alarm management unit does not start the evacuation order if a fault is detected The surveillance of connection faults is made by the evacuation link An alert of a broadcast default is given by a supervised link auxiliary contact The end of li
9. 79 869 APE 524L MAJORCOM IV Operation 1 Initial Operation When the system is started the comfort level can be heard To check this ensure that the modulation source is on Check that the comfort levels are not at zero To test the operation of the amplifiers and the speaker lines the system must be adjusted This adjustment is automatic and started by the configuration switch 5 30 To carry out this adjustment turn switch 5 to towards the bottom and reset the unit To do this turn switch 8 to ON and then to OFF If there are extension units put them in automatic configuration before the reset The system takes a few moments maximum 3 minutes to automatically configure depending on the number and types of amplifier being used Normal modulation is cut during the operation and the green LED 11 is off The yellow LEDs flash when the configuration is finished and a beep sounds Press the reset button 9 to stop the beep Put the switch 5 to OFF then 8 ON and then turn 8 to OFF The system starts normally XX 2 Operation with pre configuration The system starts automatically after a few seconds Normal modulation is restored The green LED is illuminated The system will carry out tests on different elements of the safety circuit without interrupting normal operation It is possible that the default u LED lights up This is due to the initialisation phase In this case press the reset button 9 for at le
10. OUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM VI Technical Specifications Inputs 26 OdB balanced Outputs 27 and 28 OdB balanced Safety Microphone 60dB dynamic Alarm Management Unit 24V to 48V continuous Safety amplifier switch maximum 360W on a 100V line Power Supply 230V 50Hz 24V Power Consumption 230V 24V Consumption in Standby Mode 21 W 11 3W Consumption in Evacuation Mode 23W 12 0 W SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM VII End of Line Device 1 Functions This element ensures the testing of the speaker line It must be installed at the end of the line It must be installed alone or in double on a two branched line 2 Configuration a Single branch speaker line Put the switch to 1 b Double branch line Put the switch to 2 3 Connection C 3 ss lt lt SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L
11. ast a second 3 Switching to a safety amplifier When an amplifier breakdown is detected the system switches to the safety amplifier as long as it is connected and available SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L pm MAJORCOM The safety amplifier must have the power to back up the most powerful amplifier If you have a 120W amplifier and a 360W amplifier the safety amplifier must be 360W The operation of the safety is also checked Once the defective amplifier has been changed the routing on the safety amplifier can be restarted with the reset button 9 until the routing has stopped LED 4 and 6 on the front panel 4 Evacuation Mode Evacuation mode is started either by a dry contact at the rear 39 which does not comply with EN60 849 or by sending a continuous current to the Alarm Management Unit socket UGA EN60 849 compliant or by turning the key on the front panel to manual depart 10 In this case modulation is cut and the evacuation message is broadcast The red LED 17 evacuation message is lit The tone 43 and volume 42 of the evacuation message are adjusted on the rear panel The message is heard on the internal speaker 1 which can be adjusted on the front panel 2 The message can be
12. being used connect it to the socket 35 with a 2 pair insulated cable e If an emergency microphone is not required in this installation connect the supplied resistors to the socket to simulate the presence of the microphone 4 Ways of starting the integrated digital emergency message reader a Set off by an Alarm Management Unit UGA The button 38 must be set to NO i e released See the section Connection for details The order must come from a continuous current of between 24V and 48V The link with the alarm management unit must be at a negative voltage or less than 12V b Set off by a Normally Open dry contact The button 38 must be set to NO i e released c Set off by a Normally Closed dry contact The button 38 must be set to NC or NF i e pressed in d Prealert On the configuration switch 30 number 6 must be on in order to receive the prealert message before the evacuation message The number 7 is used for setting the delay 30 seconds on OFF and 5 minutes on ON 5 Number of connected extension units a The rotary switch 31 must indicate the number of extension units being used with the IS2 base unit b If only this unit is being used then select 0 on the dial 31 C If in addition to the IS2 base unit there is an ES4 and an ES2 unit then select 2 on the dial 31 SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05
13. c AI A2 O COL loco ILILI m L n RFL UGA SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 Si ge Social RN 307 78810 FEUCHEROLLES RCS 334 579 869 APE 5241 MAJORCOM D tail du c blage des lignes HP en 3 conducteurs CRI Ent es confort Sorties vers ampli Secours Vers mme Nb Modules 1 2 1 2 Configuration Eh OO OO x prm fuse 24V fuse Micro CS UGA Ampli sec Al QL mm m n E 100V 100V MES HIS uL T T T his L us T T SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L pm MAJORCOM D tail du c blage des lignes HP en 2 conducteurs CRI et retour du troisi me fil par un autre c ble Ent es confort Sorties vers ampli Nb M secours Vers module odules 1 2 1 2 OO OO s Te D tise Terre 24V fuse Micro none CS UGA Ampli sec Al 11 2 e OL joooe 100900 UOL SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 8
14. ion liaison outputs 1 and 2 to the power amplifiers e If there is a safety amplifier connect the modulation output 28 to the safety amplifier input Sorties vers ampli secpurs 230V O C Q Conf Tm fuse Vers Nb Modules 24V fuse Micro CS UGA Ampli sec AI 6 L1 OL 10200 CI DI CI CIC AMPLIFICATEUR LIGNE 100V Sortie 100V D faut 230V AC AMPLIFICATEUR LIGNE 100V Sortie 100V D faut 230V AC AMPLIFICATEUR LIGNE 100V D faut Sortie 100V fusible Utilis en secours 230V AC SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L pa MAJORCOM Reminder of wiring for a balanced input In the case of a balanced source Sortie IS Entr e ampli In the case of an unbalanced source Sortie IS Entr e ampli On doit utiliser un jack st r o et laisser l anneau non connect SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L pm MAJORCOM e Connect the 100V outputs of the amplifiers to their respective sockets Note The second socket safety amp is to be used for
15. ne resistors are supplied by the manufacturer of the Alarm Management Unit SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 524L MAJORCOM Cas d un syst me conforme EN 60 849 Ent es confort Sorties vers ampli oun Vers module Nb Modules an O O X amp fuse Terre 24V fuse Micro none CS BT UGA Ampli sec Al Li 2 12 e OL _Jooo Jl eoo ILILIL 1LIE 1 AMPLIFICATEUR LIGNE 100V Sortie 100V AMPLIFICATEUR LIGNE 100V Sortie 100V Eo i AMPLIFICATEUR LIGNE 100V Sortie 100V 230V AC i UGA Evacuation e The Alarm Management Unit send the evacuation alert even if a fault is detected e All system faults are supervised by the Alarm Management Unit e The end of line resistors are supplied by the manufacturer of the Alarm Management Unit SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOULOUSE FRANCE T l 05 61 31 86 87 Fax 05 61 31 87 73 S A Capital 500 000 F Si ge Social RN 307 78810 FEUCHEROLLES RCS B 334 579 869 APE 5241 pa MAJORCOM Cas d un syst me non conforme EN 60 849 Ent es confort Tu ampli Secours Vers module Nb Modules 230V O O X TT mmu ano P3 24V fuse Micro nonr CS UGA Ampli
16. safety amplifier LED 29 Extension Unit connection port 5 LED amplifier breakdown 30 Configuration Selection 6 Switch to safety amplifier LED 31 Unit number rotary switch 7 LED default speaker line 32 Earthing Button 8 Stop Evacuation Message Key Position 33 Emergency 24V power supply 9 Reset button 34 Emergency Power Fuse 10 Start Evacuation Message Key Position 35 Emergency microphone connection 11 LED correct power supply 36 Microphone volume level adjustment 12 LED fault detection 37 Microphone tone Level adjustment 13 LED power fault mains power cut 38 Starting mode selection 14 LED emergency power supply fault AES 39 Dry contact remote control 15 LED mains fuse 40 Dry contact default status 16 LED emergency power fuse 41 Remote control of evacuation message 17 LED evacuation message through the current 18 LED emergency microphone 42 Volume adjustment evacuation message 19 LED evacuation player fault 43 Tone adjustment evacuation message 20 LED faulty connection with emergency 44 100V safety amplifier input microphone 45 100V extension unit output 21 LED software or u controller fault 22 LED extension unit connection fault 23 Warning Buzzer 24 Power supply 230V 50Hz 25 Mains Fuse 46 47 48 49 100V Input amplifier 1 100V Output to speaker line 1 100V Input amplifier 2 100V Output to speaker line 2 SERVICES TECHNIQUES ET COMMERCIAUX 56 Chemin de la Flamb re 31300 TOUL