1. Installation Manual SMA SPEEDWIRE WEBCONNECT DATA MODULE SWWEBCONDM A en 16 Version 1 6 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognized even if not explicitly identified as such A lack of identification does not mean that a product or symbol is not trademarked The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of these marks by SMA Solar Technology AG is under license Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization Inc QR Code is a registered trademark of DENSO WAVE INCORPORATED Phillips and Pozidriv are registered trademarks of Phillips Screw Company Torx is a registered trademark of Acument Global Technologies Inc SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail infoGSMA de
2. 2004 to 2014 SMA Solar Technology AG All rights reserved 2 SWWEBCONDM IA en 1 6 Installation Manual SMA Solar Technology AG Table of Contents Table of Contents Information on this Document 5 DUMP UID TE EET 5 122 ORGS mi o bebat IR ISTRIA 5 1 3 Additional Informotion 5 LA mbar elia 6 Lo Dego TT 6 NME rieti lire ted ka 7 7 ile 8 2 pended rad unpu a ue ese Sasa 8 2 2 Sale PIEGGUNONS ccu doce ia 8 23 Operating Insfructions 9 24 Oba Pesca OU Ud 10 Scope of Delivery 11 Product Description 12 4 1 Speedwire Webconnect Data Module 12 4 2 Possible Network Topologies 13 AD TyDe Label u uc debian ead den Sedet ok 13 44 kn 14 CONNCCHON x i died ii 15 5 1 Mounting Position and Cable Route 15 5 2 Cable Requirements and Information on Cable Routing 15 5 3 Installing the Speedwire Webconnect Data Module 16 5 4 Connecting the Speedwire Webconnect Data Module 18 Installation Manual SWWEBCONDM IA en 1 6 3 Table of Contents SMA Solar Technology AG 6 Commissionin
3. 1 L1 All UDP ports gt 1024 on the router must be open for outgoing connections If there is a firewall installed on the router you might have to adjust the firewall settings It must be possible for the outgoing router connections to reach all Internet destinations target IP target port If there is a firewall installed on the router you might have to adjust the firewall settings On the router with NAT Network Address Translation no port forwarding must be entered Potential communication problems can thus be prevented There must be no packet filtering or manipulation for SIP packets installed on the router i Maximum permissible number of devices for a small scale PV system in Sunny Portal In Sunny Portal a maximum of four inverters with installed Speedwire Webconnect data module is permitted per small scale PV system Installation Manual SWWEBCONDM IA en 1 6 23 6 Commissioning SMA Solar Technology AG i Small scale PV system with Speedwire Webconnect data module cannot be combined with other systems IF you already have a system with a different communication device e g Sunny WebBox in Sunny Portal you will still need to create a separate small scale PV system with Speedwire Webconnect data module It is not possible to combine the Speedwire Webconnect data module and other communication devices within one system in Sunny Portal Sunny Portal treats the existing system and the new small scale PV syste
4. and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Press the left hand and righthand lock hooks outwards and remove the ribbon cable plug from the center connector strip of the inverter Release the screw of the display far enough to allow the display to be flipped up Flip up the display until it snaps into place Unscrew the swivel nut of the cable gland Remove the network cables from the Speedwire Webconnect data module Unscrew the counter nut of the cable gland Remove the cable gland and network cables from the inverter Cen Se SS Release the hexagon socket screw AF 3 of the Soeedwire Webconnect data module and remove the module 10 Flip the display down and fasten the display screw hand tight 11 Seal the enclosure opening of the inverter with the corresponding filler plug 12 Close the inverter see inverter installation manual 7 2 Packaging the Speedwire Webconnect Data Module for Shipping Speedwire Webconnect data module for shipping Use the original packaging or packaging that is suitable for the weight and size of the Soeedwire Webconnect data module see Section 9 Technical Data page 28 7 3 Disposing of the Speedwire Webconnect Data Module Dispose of the Speedwire Webconnect data module in accordance with the regulations for the disposal of electronic waste applicable at the installation site Installation Ma
5. cable gland Ensure that any unused cable openings are sealed with filler plugs Screw the swivel nut of the cable gland on loosely Insert the network cables into the network ports This can be done in any order Fasten the swivel nut on the cable gland hand tight This will fix the network cables in place Flip the display down and fasten the screw of the display hand tight Close the inverter see inverter installation manual In a small scale PV system depending on the system topology connect at least one inverter directly to the router using a network cable In a large scale PV power plant with Cluster Controller connect the Cluster Controller to the Speedwire network in accordance with the required network topology see installation manual of the Cluster Controller Installation Manual SWWEBCONDM IA en 1 6 19 6 Commissioning SMA Solar Technology AG 6 Commissioning 6 1 Commissioning a Large Scale PV Power Plant with Cluster Controller Requirements Speedwire Webconnect data modules must be installed in the inverters see Section 5 3 page 16 Speedwire Webconnect data modules must be connected see Section 5 4 page 18 The Cluster Controller must be connected to the Speedwire network in accordance with the desired network topology see installation manual of the Cluster Controller Procedure 1 Commission all inverters see inverter installation manual 2 For optimum operation of large scale PV power
6. length Protocols Data interface SMA Modbus SunSpec Terminals Type of plug RJ45 Number of RJ45 terminals Ambient Conditions for Storage Transport Ambient temperature 2 40 C to 85 C 10 to 100 Relative humidity non condensing 28 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 10 Contact 10 Contact If you have technical problems concerning our products please contact the SMA Service Line We need the following information in order to provide you with the necessary assistance Inverters Device type and serial number see type label Firmware version tap twice on the inverter display or see Sunny Portal or Sunny Explorer Speedwire Webconnect data module Device type serial number and hardware version see type label Number of Speedwire Webconnect data modules connected Large scale PV power plants Serial number and firmware version of the Cluster Controller Small scale PV systems Name of your Sunny Portal system PIC and RID of the Speedwire Webconnect data module Australia SMA Australia Pty Ltd Toll free for 1800 SMA AUS Sydney Australia 1800 762 287 International t l 2 9491 4200 Belgien SMA Benelux BVBA SPRL 32 15 286 730 Belgique Mechelen Belgi Brasil Vide Espa a Espanha esko SMA Central amp Eastern Europe 420 235 010 417 s r O Praha Chile Ver Espafia Danmark Se Deutschland Tyskland Installation Manual SWWEBCONDM IA en
7. 1 6 29 10 Contact Deutschland SMA Solar Technology AG Niestetal Espafia SMA Ib rica Tecnolog a Solar S L U Barcelona France SMA France S A S Lyon India SMA Solar India Pvt Ltd Mumbai Italia SMA Italia S r l Milano K rrpoc BA rre Kibris Bkz EMa a Yunanistan Luxemburg Siehe Belgien Luxembourg Voir Belgique Magyarorsz g l sd esko Csehorsz g Nederland zie Belgien Belgi sterreich Siehe Deutschland Per Ver Espa a Polska Patrz esko Czechy 30 SWWEBCONDM IA en 1 SMA Solar Technology AG Medium Power Solutions Wechselrichter 49 561 9522 1499 Kommunikation 49 561 9522 2499 SMA Online Service Center www SMA de Service Hybrid Energy Solutions Sunny Island 49 561 9522 399 PV Diesel 49 561 9522 3199 Hybridsysteme Power Plant Solutions 49 561 9522 299 900 14 22 22 Sunny Central Llamada gratuita en Espa a Internacional 34 902 14 24 24 Medium Power Solutions 33 472 09 04 40 33 472 09 04 41 Onduleurs Communication Hybrid Energy Solutions Sunny Island 33 472 09 04 42 Power Plant Solutions Sunny Central 33 472 09 04 43 91 22 61713888 39 02 8934 7299 Installation Manual SMA Solar Technology AG 10 Contact Portugal SMA Solar Technology Portugal Isento de taxas em 800 20 89 87 Unipessoal Lda Portugal Lisboa Internacional 351 2 12 37 78 60 Rom nia Vezi Cesko Cehia Schweiz Siehe Deutschland Slovensko pozri Cesko
8. Cesk republika South Africa SMA Solar Technology 08600 SUNNY South Africa Pty Ltd 08600 78669 Centurion Pretoria International 27 12 643 1785 United SMA Solar UK Ltd 44 1908 304899 Kingdom Milton Keynes E ada SMA Hellas AE 801 222 9 222 International 30 212 222 9 222 Ine SMA Solar Thailand Co Ltd 66 2 670 6999 NINNI SMA Technology Korea Co Ltd 82 2 508 8599 N 971 2 234 6177 SMA Middle East LLC ca gl baai du yell Other International SMA Service Line Toll free worldwide 00800 SMA SERVICE countries Niestetal 800 762 7378423 Installation Manual SWWEBCONDM IA en 1 6 31 SMA Solar Technology
9. D Figure 2 Components of the order option Speedwire Webconnect data module as retrofit kit Position Quantity Designation A 1 Speedwire Webconnect data module SWDM 10 B 1 Installation manual G 1 M32 cable gland with sealing plug two hole cable support sleeve and counter nut D 2 Label with PIC and RID for registration of a small scale PV system in Sunny Portal Installation Manual SWWEBCONDM A en 16 11 4 Product Description SMA Solar Technology AG 4 Product Description 4 1 Speedwire Webconnect Data Module The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimized 10 100 Mbit data transmission between Speedwire devices in PV systems The Webconnect function enables direct data transmission between the inverters of a small scale PV system and the Internet portal Sunny Portal without any additional communication device and for a maximum of four inverters per Sunny Portal system For this a Speedwire Webconnect data module must be installed in each of the inverters You can access your Sunny Portal system from any computer with an Internet connection The Speedwire Webconnect data module performs the following tasks Setup of a Speedwire network in small scale and large scale PV power plants Data exchange with Sun
10. e gland fixes the network cables to the inverter enclosure The cable gland also protects the interior of the inverter from dust intrusion and moisture penetration A B C D Figure 4 Design of cable gland Position Designation A Filler plug B Seal C Swivel nut D Counter nut 14 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 5 Connection 5 Connection 5 1 Mounting Position and Cable Route A Figure 5 Mounting position and cable route in the inverter with the lower enclosure lid open and the display flipped up Position Designation A Flipped up display B Cable route to the network ports C Opening in the inverter enclosure with filler plug D Mounting position of the Speedwire Webconnect data module in the inverter 5 2 Cable Requirements and Information on Cable Routing The cable length and cable quality affect the signal strength in the Speedwire network Observe the following cable requirements and the information on cable laying i Interference in data transmission due to unshielded energy cables IF unshielded power cables are used they generate an electromagnetic field during operation which may induce interference in network cables during data transmission When laying network cables observe the following minimum clearances to unshielded energy cables Forinstallation without separating strip at least 200 mm Forinstallation with aluminum separating stri
11. ed in this document must be performed by qualified persons only Qualified persons must have the following skills Training in the installation and commissioning of electrical devices and installations Knowledge of how to deal with the dangers and risks associated with installing and using electrical devices and installations Knowledge of all applicable standards and directives Knowledge of how an inverter works and is operated Knowledge of and compliance with this document and all safety precautions 1 3 Additional Information Links to additional information can be found at www SMA Solar com Not all documents are available in all languages Document title Document type Firmware Update with SD Card Technical Description SMA Speedwire Fieldbus Technical Information SMA Modbus Interface Technical Description SunSpec Modbus Interface Technical Description Installation Manual SWWEBCONDM IA en 1 6 5 1 Information on this Document SMA Solar Technology AG 1 4 Symbols Symbol Explanation DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury or serious injury A CAUTION Indicates a hazardous situation which if not avoided can result in minor or moderate injury NOTICE Indicates a situation which if not avoided can result in property damage safety relevant Information that is important for a specific topic or goal but is not Indicates a r
12. equirement for meeting a specific goal L DI Desired result Xx A problem that might occur 1 5 Typographies Typography Explanation bold Display texts Elements on a user interface Terminals Elements to be selected Elements to be entered gt e Connects several elements to be selected Button Key Button or key to be selected or pressed 6 SWWEBCONDM A en 16 Example The value can be found in the field Energy Select Settings Enter the value 10 in the field Minutes Select Settings gt Date Select Next Installation Manual SMA Solar Technology AG 1 Information on this Document 1 6 Nomenclature Complete designation Designation in this document Photovoltaic system PV system Small scale photovoltaic system Small scale PV system Large scale photovoltaic power plant Large scale PV power plant SMA Cluster Controller Cluster Controller SMA Speedwire Speedwire SMA Speedwire Webconnect Data Module Speedwire Webconnect Data Module SMA Webconnect function Webconnect function SMA inverter Inverter 1 7 Figures The figures in this document have been created for Sunny Boy inverters and may deviate slightly in some cases for Sunny Tripower inverters Installation Manual SWWEBCONDM IA en 1 6 7 2 Safety SMA Solar Technology AG 2 Safety 2 1 Intended Use The Speedwire Webconnect data module is a Speedwire communication interface with Webconnect function for inverters Speedwire
13. gh to allow the display to be flipped up Flip up the display until it snaps into place Push the pre mounted filler plug out of the second hole from the left in the inverter enclosure and retain it for future decommissioning SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 5 Connection 5 Attach the cable gland to the enclosure opening 10 11 using the counter nut Insert the Speedwire Webconnect data module MEL Sd T and slide the ribbon cable upwards behind the l lt tr display The key on the top edge of the Speedwire Webconnect data module must fit into the hole in the plastic retainer in the inverter Fasten the Speedwire Webconnect data module hand tight using a hexagon socket screw AF 3 torque 1 5 Nm Flip the display down Plug the ribbon cable plug onto the center connector strip i Stick one of the labels with the data for registration in Sunny Portal PIC and RID on the outside of the inverter in the vicinity of the type label If you do not wish to proceed immediately with the connection of the Speedwire Webconnect data module close the inverter see inverter installation manual Installation Manual SWWEBCONDM A en 1 IZ 5 Connection SMA Solar Technology AG 5 4 Connecting the Speedwire Webconnect Data Module Depending on the system topology you require you must connect either one or two cables to the Speedwire Webconnect data module Requireme
14. gisissisen 20 6 1 Commissioning a Large Scale PV Power Plant with Cluster Controller cost sbattere ini 20 6 2 Commissioning a Small Scale PV Sysfem 20 6 3 Managing a Small Scale PV System with Sunny Explorer 21 6 3 1 Functions and Parameter Settings in Sunny Explorer 21 6 3 2 Creating a Small Scale PV System in Sunny Explorer 22 6 4 Configuring the Modbus Function 22 6 5 System Registration in Sunny 23 6 5 1 Registering a Large Scale PV Power Plant with Cluster Controller Ife DUMMY A dois ua tea eo ton ano radiale Ramee ah esca 23 6 5 2 Registering the Small Scale PV System in Sunny Portal 23 7 Decommissioning 25 7 1 Removing the Speedwire Webconnect Data Module 25 7 2 Packaging the Speedwire Webconnect Data Module for SMD ONG RETE sanan NON 25 7 3 Disposing of the Speedwire Webconnect Data Module 25 8 Troubleshooting 2 9 Technical Data siss 28 VO COMOT ieri narrati 29 4 SWWEBCONDM IA en 1 6 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document 1 1 Validity This document is valid for device type SWDM 10 GR1 Speedwire Webconnect data module from hardware version A and firmware version 1 00 20 R 1 2 Target Group The tasks describ
15. is a cable based type of communication based on the Ethernet standard and the communication protocol SMA Data2 This enables inverter optimized 10 100 Mbit data transmission between Speedwire devices in PV systems The Webconnect function enables direct data transmission between the inverters of a small scale PV system and the Internet portal Sunny Portal without any additional communication device and for a maximum of four inverters per Sunny Portal system For this a Speedwire Webconnect data module must be installed in each of the inverters You can access your Sunny Portal system from any computer with an Internet connection The inverter still complies with the standard after the product has been installed For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product The type label must remain permanently attached to the product Use the Speedwire Webconnect data module only in accordance with the enclosed documentation and with the local standards and directives Any other application may cause personal injury or property damage The enclosed documentation is an integral part of this product Read and observe the documentation Keep the documentation in a convenient place for future reference 2 2 Safety Precautions This section contains safety precautions that must be observed at all times when working on or w
16. ith the product To prevent personal injury and property damage and to ensure long term operation of the product read this section carefully and follow all safety precautions at all times DANGER Danger to life due to electric shock when opening the inverter High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury Prior to performing any work on inverter always disconnect the inverter from all voltage sources on the AC and DC sides see inverter installation manual Observe the waiting time to allow the capacitors to discharge 8 SWWEBCONDM IA en 1 Installation Manual SMA Solar Technology AG 2 Safety A CAUTION Risk of burns due to hot enclosure parts Some parts of the inverter enclosure can get hot during operation Touching these enclosure parts can result in burn injuries Do not touch any parts other than the lower enclosure lid of the inverter during operation NOTICE Damage to the inverter due to electrostatic discharge The internal components of the inverter can be irreparably damaged by electrostatic discharge Ground yourself before touching any inverter component 2 3 Operating Instructions NOTICE High costs possible due to inappropriate Internet tariffs When using the Webconnect function a constant Internet connection is required Depending on the quality of the Internet connection the data tran
17. m with Speedwire Webconnect data module as independent systems Create a new small scale PV system with Speedwire Webconnect data module i Replacing the Speedwire Webconnect data module in the inverter If you have replaced the Speedwire Webconnect data module in the inverter with a new Speedwire W ebconnect data module the PIC and the RID of the inverter change Therefore you must also replace the inverter using the PV System Setup Assistant in Sunny Portal see the Sunny Portal user manual In the PV System Setup Assistant you must enter the PIC and the RID of the new Speedwire Webconnect data module Starting the PV System Setup Assistant in Sunny Portal The PV System Setup Assistant is a step by step guide to the processes required for user registration and the registration of your system in Sunny Portal Procedure 1 Go to www SunnyPortal com 2 Select PV System Setup Assistant The PV System Setup Assistant opens 3 Follow the instructions of the PV System Setup Assistant 24 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 7 Decommissioning 7 Decommissioning 7 1 Removing the Speedwire Webconnect Data Module 1 DANGER Danger to life due to electric shock when opening the inverter High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury Disconnect the inverter from all voltage sources on the AC and DC sides
18. ncluded in the delivery After installation of the Speedwire Webconnect data module a label should be attached to the exterior of the inverter in the vicinity of the type label Keep the other label in a safe place for future reference 4 2 Possible Network Topologies The possible network topologies depend on the devices used and on the number of network ports The Speedwire Webconnect data module has two network ports For further information on network topologies refer to the Technical Information SMA Speedwire Fieldbus at www SMA Solar com 4 3 Type Label The type label clearly identifies the product The type label is located in the righthand top corner on the front of the product You can read the following data from the type label Device type Type Serial number Serial No Hardware version Version PIC e RID e MAC address MAC Address You will require the information on the type label to use the product safely and when seeking customer support from the SMA Service Line Installation Manual SWWEBCONDM IA en 1 6 13 4 Product Description SMA Solar Technology AG Symbols on the Type Label Symbol Designation Explanation C 2 CE marking The product complies with the requirements of the applicable EU directives Q uu C Tick The product complies with the requirements of the applicable Australian EMC standards S Data matrix code 2D code for device specific characteristics 4 4 Cable Gland The cabl
19. nt The network cables must be pre assembled in accordance with the system topology and the cable requirements see Section 5 2 page 15 Additionally required material not included in the scope of delivery Network cable see Section 5 2 Cable Requirements and Information on Cable Routing page 15 Procedure 1 DANGER Danger to life due to electric shock when opening the inverter High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury If the inverter has not yet been opened disconnect the inverter from all voltage sources on the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge 2 Flip the display up until it snaps into place 3 Unscrew the swivel nut of the cable gland on the inverter 4 Pressthe seal outofthe cable gland from the inside 18 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 5 Connection 10 11 12 13 14 15 Lead the network cables from the outside into the inverter through the loose swivel nut and the cable gland For each network cable remove one of the filler plugs from the seal and retain for later decommissioning 3 Lead the network cables through the swivel nut and into the seal Route the network cable plugs into the 4 inverter to the network ports Press the seal into the
20. nual SWWEBCONDM IA en 1 6 25 8 Troubleshooting SMA Solar Technology AG 8 Troubleshooting i Corrective measures regarding Modbus errors Corrective measures regarding Modbus errors can be found in the Technical Descriptions SMA Modbus Interface or SunSpec Modbus Interface Problem Cause and corrective measures The Speedwire Possibly there is no Speedwire connection Webconnect data module cannot be accessed Corrective measures Ensure that all network cable plugs are inserted and locked Ensure that all inverters in the system are in operation Ensure that the system router is switched on Ensure that the ribbon cable plug of the Speedwire Webconnect data module is correctly plugged into the center connector strip in the inverter The Webconnect Speedwire data module might not have a valid IP address Corrective measures Ensure that DHCP is enabled for the router or Assign an appropriate static IP address to the Speedwire Webconnect data module via SMA Connection Assist or Sunny Explorer You can obtain the Sunny Explorer and SMA Connection Assist software free of charge from the download area at www SMA Solar com The firewall may not be set correctly Corrective measures In the firewall activate ports 3478 and 9523 see firewall manual It is possible that the UDP ports in the router for outgoing connections are not open Corrective measures Open the UDP ports gt 1024 in
21. ny Portal In small scale PV systems via a router with Internet connection Inlarge scale PV power plants via the Cluster Controller Data exchange with Sunny Explorer from version 1 06 For PV systems in Italy Connection to or disconnection from the utility grid and definition of the frequency limits to be used with IEC61850 GOOSE messages The Modbus interface of the Speedwire Webconnect data module is designed for industrial use and has the following tasks Remote query of measured values Remote setting of parameters Setpoint specifications for system control The Speedwire Webconnect data module is available as a retrofit kit or is pre installed in the inverter Z 2 F Figure 3 Design of the Speedwire Webconnect data module Forinformation on which of the supported SMA inverters see Section 2 4 support the Modbus interface of the Speedwire Webconnect data module see the datasheet SMA Modbus DB en xlsx at www SMA Solar com 12 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 4 Product Description Position Designation Hexagon socket screw AF 3 Network port A Network port B Ribbon cable plug Ribbon cable m O gt Type label Label with PIC and RID for registration of a small scale PV system in Sunny Portal To activate the Speedwire Webconnect data module of a small scale PV system in Sunny Portal you will need the PIC and RID numbers printed on the label i
22. p at least 100 mm For installation with steel separating strip at least 50 mm Installation Manual SWWEBCONDM IA en 1 6 15 5 Connection SMA Solar Technology AG Cable requirements E g UV resistant for outdoor use Number of insulated conductor pairs and insulated conductor cross section at least 2 x 2 x 0 22 mm or at least 2 x 2 AWG 24 External diameter of the cable the maximum external diameter of the cable depends on the size of the cable gland included in the delivery Cable category Cat5 Cat5e Cat6 Cat a Cat7 Cable shield SF UTP S UTP SF FTP S FTP Plug type RJ45 for Cat5 Cat5e Cat6 Cat a Cable length between two nodes max 50 m with patch cable max 100 m with installation cable SMA Solar Technology AG recommends the following cable types For outdoor use SMA COMCAB OUTxxx For indoor use SMA COMCAB INxxx The cables are available in the lengths xxx 100 m 200 m 500 m and 1 000 m 5 3 Installing the Speedwire Webconnect Data Module 1 RIN Danger to life due to electric shock when opening the inverter High voltages are present in the conductive components of the inverter Touching live components results in death or serious injury Disconnect the inverter from all voltage sources on the AC and DC sides and open it see the inverter installation manual Observe the waiting time to allow the capacitors to discharge Release the screw of the display far enou
23. plants with Cluster Controller deactivate the Webconnect function of the inverters with installed Speedwire Webconnect data module see user manual of the Cluster Controller In large scale PV power plants with Cluster Controller communication with Sunny Portal takes place via the Cluster Controller itself 6 2 Commissioning a Small Scale PV System Requirements Speedwire Webconnect data modules must be installed in the inverters see Section 5 3 page 16 1 Speedwire Webconnect data module must be connected see Section 5 4 page 18 There must be a router with Internet connection in the local network of the system At least one inverter must be connected to the router Ifthe IP addresses in the local network are to be assigned dynamically DHCP must be activated in the router see the router manual If you do not want to use DHCP or your router does not support DHCP use either SMA Connection Assist or Sunny Explorer to integrate the inverters with the Speedwire Webconnect data module into your network see Section 2 4 Supported Products page 10 Procedure 1 Commission all inverters see inverter installation manual 2 For systems in Italy in order to activate reception of control signals from the grid operator in the Speedwire Webconnect data module carry out the following steps Connect with Sunny Explorer see Section 6 3 2 page 22 Enter your personal SMA Grid Guard code in Sunny Explorer see Sunn
24. rter is lower than 2 53 you must perform a firmware update to version 2 53 or higher for this inverter For information on performing the firmware update refer to the Technical Description Firmware Update with SD Card at www SMA Solar com Additional SMA Products The Speedwire Webconnect data module can be configured with the following communication products e SMA Cluster Controller from firmware version 1 0 Sunny Explorer from software version 1 06 e SMA Connection Assist from software version 1 00 8 R Sunny Explorer and SMA Connection Assist are available free of charge at www SMA Solar com 10 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 3 Scope of Delivery 3 Scopeof Delivery Check the delivery for completeness and any visible external damage Contact your distributor if the scope of delivery is incomplete or if there is any damage Order option Speedwire Webconnect data module pre installed in the inverter A B C Figure 1 Components of the order option Speedwire Webconnect data module pre installed in the inverter Position Quantity Designation A 1 Installation manual B 1 M32 cable gland with sealing plug two hole cable support sleeve and counter nut C 1 Label with PIC Product Identification Code identification key for registration in Sunny Portal and RID Registration Identifier registration ID in Sunny Portal Order Option Speedwire Webconnect data module as retrofit kit B C
25. sfer volume for an inverter is between 150 MB and 550 MB per month When using the system overview in Sunny Portal with live data display there is an additional data volume of 600 kB per hour Since there is a permanent Internet connection to Sunny Portal time based billing systems should be avoided High costs could be incurred SMA Solar Technology AG recommends using an Internet flat rate i If UMTS is used VoIP is required IF UMTS is used VoIP Voice over IP is required to use the Webconnect function Ensure that the UMTS provider also provides the VoIP service Installation Manual SWWEBCONDM IA en 1 6 9 2 Safety SMA Solar Technology AG 2 4 Supported Products SMA inverter The Speedwire Webconnect data module must only be installed in the following SMA inverters from the indicated inverter firmware version SMA Inverter From inverter firmware version SB 2500TLST 21 2 53 SB 3000TLST 21 SB 3000TL 21 SB 3600TL21 SB 4000TL 21 SB 5000TL21 SB 6000TL 2 1 STP 8000TL 10 STP 10000TL 10 STP 12000TL 10 STP 15000TL 10 STP 17000TL 10 STP 1 5000TLEE 10 STP 15000TLHE 10 STP 20000TL 30 all STP 25000TL 30 STP 20000TLEE 10 293 STP 20000TLHE 10 For information on which of these SMA inverters with Soeedwire Webconnect data module supports the Modbus interface of the Speedwire Webconnect data module see the datasheet SMA Modbus DB en xlsx at www SMA Solar com Ifthe firmware version of the inve
26. ters see Section 2 4 support the Modbus interface of the Speedwire Webconnect data module see the datasheet SMA_Modbus DB en xlsx at www SMA Solar com Procedure If necessary adjust the preset ports in the Soeedwire Webconnect data module for the Modbus communication see the Technical Descriptions SMA Modbus Interface or SunSpec Modbus Interface at www SMA Solar com 22 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 6 Commissioning 6 5 System Registration in Sunny Portal 6 5 1 Registering a Large Scale PV Power Plant with Cluster Controller in Sunny Portal Requirements The large scale PV power plant must be commissioned see Section 6 1 page 20 Your computer must have an Internet connection O The Cluster Controller must be connected to a router with Internet connection see installation manual of the Cluster Controller JavaScript must be enabled in the web browser Procedure In large scale PV power plants with Cluster Controller register in Sunny Portal via the user interface of the Cluster Controller see user manual of the Cluster Controller 6 5 2 Registering a Small Scale PV System in Sunny Portal Requirements The small scale PV system must be commissioned see Section 6 2 page 20 PIC and RID of the Speedwire Webconnect data module must be available Your computer must have an Internet connection JavaScript must be enabled in the web browser 1
27. the following parameters in Sunny Explorer Device name of the inverter Automatic IP configuration On Off DNS IP gateway IP IP address subnet mask Webconnect function On Off Installation Manual SWWEBCONDM IA en 1 6 21 6 Commissioning SMA Solar Technology AG 6 3 2 Creating a Small Scale PV System in Sunny Explorer Requirements The system must be commissioned see Section 6 2 page 20 Sunny Explorer must be installed on the computer see Section 2 4 Supported Products page 10 Procedure 1 Connect the computer to the system router with a network cable 2 If you have used SMA Connection Assist for the static network configuration ensure that SMA Connection Assist has ended 3 Start Sunny Explorer and create a Speedwire system for the small scale PV system in Sunny Explorer see Sunny Explorer help 6 4 Configuring the Modbus Function If you wish to access SMA inverters with Modbus interface make sure that the Modbus connection of the devices has been configured correctly In devices with Modbus the same port must be set up for the Modbus communication The Modbus function has been deactivated by default in the Speedwire Webconnect data module and port 502 has been set for the Modbus servers TCP and UDP For information on using the Modbus interface see the Technical Descriptions SMA Modbus Interface or SunSpec Modbus Interface at www SMA Solar com For information on which of the supported SMA inver
28. the router for outgoing connections The IP filter might not have been set up correctly Corrective measures Adjust the IP filter settings see router manual 26 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG Problem The Speedwire Webconnect data module cannot be accessed Installation Manual 8 Troubleshooting Cause and corrective measures It is possible that packet filtering or manipulation for SIP packets is installed on the router Corrective measures Uninstall the packet filtering for SIP packets or the manipulation for SIP packets on the router It is possible that port forwarding has been entered on the router with NAT function Network Address Translation Corrective measures Remove the port forwarding from the router with NAT function It is possible that the inverter does not recognize the Speedwire Webconnect data module The firmware version of the inverter is not supported see Section 2 4 page 10 Corrective measures Update the inverter firmware see the Technical Description Firmware Update with SD Card at www SMA Solar com SWWEBCONDM lA en 16 27 9 Technical Data 9 Technical Data General Mounting location SMA Solar Technology AG in the inverter via the inverter Voltage supply Mechanical Data 73 mm x 88 mm x 34 mm Width x height x depth Communication Communication interface Speedwire Webconnect 100 m Maximum cable
29. y Explorer help 20 SWWEBCONDM IA en 16 Installation Manual SMA Solar Technology AG 6 Commissioning Set the following parameters in Sunny Explorer for setting parameters in a device see Sunny Explorer help External communication gt IEC 61850 configuration Parameter Value range Resolution Default Application ID 0 to 16384 1 16384 Goose Mac address 01 0C CD 01 00 00 1 01 0C CD 01 00 00 to 01 0C CD 01 02 00 Inthe field Application ID enter the application ID of the grid operator gateway You will receive this value from your grid operator You can enter a value between 0 and 16384 The value 16384 indicates deactivated In the field Goose Mac address enter the MAC address of the grid operator gateway from which the Speedwire Webconnect data module is to receive the control commands You will receive this value from your grid operator V The receipt of grid operator control signals is now activated 6 3 Managing a Small Scale PV System with Sunny Explorer 6 3 1 Functions and Parameter Settings in Sunny Explorer The following functions for system management are available in Sunny Explorer Overview of the system status Graphic display of key PV system data device data and energy values Parameterization of individual devices or entire device classes Simple diagnostics thanks to display of errors and events Data export of inverter energy values and events in CSV format Device updates You can change