Home
MIC-ALM 8 Input Alarm Card Installation Manual
Contents
1. 4 Ensure the MIC400 Power Supply Unit is completely disconnected from the power source 5 Open the PSU lid and locate the washer pump drive header HD1 at the upper left hand side of the MIC ALM see figure 2 6 Feed the washer pump drive power cable through the one of the weatherproof glands leave sufficient slack to connect to the HD1 terminal then tighten the gland 7 Connect the washer pump drive power cable to the MIC ALM using the HD1 terminal the connections required are shown below HD1 Washer Drive 1 Relay contact 1 2 Relay contact 2 8 Secure all external pipe work and cabling fill the reservoir 9 Press the push to test button SW1 to test the pump operation hold button SW1 down to expel the air from the tubing amp prime the pump for operation 10 When the pump is primed re seal the MIC400 PSU 11 Point the MIC400 at the wash nozzle and set the wash wipe position via Camset Setup page poe ae Contact CHAPTER 4 Technical Specifications BOSCH Bosch Security Systems Issue 1 Invented for life Americas Bosch Security Systems Inc 850 Greenfield Road Lancaster Pennsylvania 17601 USA Telephone 1 888 289 0096 Fax 1 585 223 9180 Email security sales us bosch com www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch c
2. HD3 Alarm Output 1 To connect third party external alarm contacts please do the following 1 Open the PSU lid and locate the alarm header HD4 located at the lower 1 Relay contact 1 left hand side of the MIC ALM card Feed the alarm wires through one of the weather proof gland leaving sufficient slack to reach the terminal 2 Relay contact 2 block HD4 2 Wire the alarms into HD4 as shown in the table below HD5 Alarm Output 2 HD4 Alarm Inputs i 1 Relay contact 1 1 Alarm 1 2 w 2 Relay contact 2 3 Alarm 2 A Alarm 3 4 The auxiliary contacts at HD3 and HD5 are rated to 240vAC at 5 Amps these are not fused on the card so must be externally fused by the 5 Ov installer to suit the current draw to be expected by any third party equipment 6 Alarm 4 5 The auxiliary outputs HD3 and HD5 are currently configured to close as 7 Alam5 follows 8 Ov HD3 any of alarms 1 to 4 active HD5 any of alarms 5 to 8 active 9 Alarm 6 6 Each alarm contact has an LED next to it which will not be lit whenever 10 Alarm an alarm is received for that contact in addition there are LED s for the 11 Ov Washer Drive HD1 and the two 2 Auxiliaries HD3 and HD5 which will be lit when the respective relay contact is closed 12 Alarm 8 Configuring the Alarms through Camset BOSCH Bosch Security Systems Issue 1 Invented for life Configuring the MIC ALM 8 input alarm card is curre
3. OM R s i e ae TSE figure 2 The alarm board is enabled by setting the multi alarm mode on when active the alarm board LED 10 should start flashing 4wubtohome Preset 1 Auto lA OW Autohome Sequence Auto lA OFF Autohome OFF Min Int Spd 4 4uboLowlight OF Mas Gain Ll 14 4uboLowlight OFF Default Presets E TO 64 j j s 0e Privacy mask Coption exit WashWipe On Off The relay operation is controlled as follows If selected to On a wash preset position can be learned by pointing the camera at the washer nozzle and setting Wash position When the Wash button is pressed OSC Bosch Security Systems Issue 1 B H Invented for life ae Fe The MIC ALM 8 Input Alarm Card is also capable of supporting third party washer relay activate relay pumps and reservoirs The washer function provides a volt free contact output Relay closes on y Relay opens on alarm rated at 240VAC at 5 Amps wiring for this supply must be provided by the installer ae and it is recommended that this supply is externally fused A push to test button SW1 is also provided to test the pump operation and expel air to prime the pump ready for operation The relay alarm rearm time is controlled by the four radio buttons Times shown are in seconds The washer pump reservoir bottle amp 5mm tubing are not supplied by Bosch Security Systems and will need to be purchased separately to suit the particular
4. is operated If the Auto Alarm is selected to off the camera still reports the status of the alarm bit to When the Setups button is selected the sub window shown below is opened This the control system but the camera does nothing else in response to the tamper provides access to the alarms setup functions which are detailed below switch input Multi Alarm On Off Setups washwipe On sb position The Multi Alarm facility is used in conjunction with the Multi Alarm Setup window Wwashiwipe Of po and can only be used if the MIC ALM 8 input alarm card is fitted to the power AAG supply box or if the Power Supply Unit is an IR version which has integrated ETERS e el maka alarms and washer function If the MIC ALM is not fitted the camera must be set to Multi Alarm On PONENT Se Multi Alarm off to prevent inconsistent operation of the camera a iJ 2 3 4 5 6 TENTE fel pe Fer eae The numeric buttons 1 to 12 allow for the learning of alarm presets positions for Sen evens Te Hee aes eee ae each of the alarm channels normally 1 to 8 but 9 to 12 have been included for ee el ee future designs To make the camera go to these presets when the alarm is e TE aaa i e eee activated both the Auto Alarm On and Multi Alarm On must be selected The eof MIC ALM Card fitted in the power supply has on it two relays for alarm status output HD3 and HD5 along with a relay to drive a washer pump HD1 as shown on Digital oom On Auto Flip
5. the event of damaged goods e The shipping cartoon is the best way to transport the unit save it amp all other packaging materials for future use If the unit must be returned use the original packing materials CAUTION Use proper ESD handling precautions to avoid electrostatic discharge Wear a grounded wrist strap to prevent damage when handling electro sensitive printed circuit boards Packaging Contents Please check for the following contents e MIC ALM 8 input Alarm Card Installation Manual this Booklet e MIC ALM 8 Input Alarm Card CHAPTER2 MIC ALM 8 Input Alarm Card Functionality The MIC ALM 8 Input Alarm Card provides 8 contacts which enable up to 8 external alarms to be connected to the MIC400 camera The MIC ALM Card also provides support for third party washer pumps and reservoirs and two 2 auxiliary output relays each rated at 240vAC up to 5 Amps The washer function provides a volt free contact output rated at 240vAC at 5 Amps wiring for this supply must be provided by the installer and it is recommended that this supply is externally fused A push to test button SW1 is also provided to test the pump operation and expel air to prime the pump ready for operation The drive signal Washer Dr is a TTL signal generated by the MIC400 camera this TTL signal causes the relay drive transistor to switch on thus energizing the relay and closing the relay contacts thereby activating the supply to the washer pump To
6. MIC ALM 8 Input Alarm Card Installation Manual Bosch Security Systems EN Installation and Operation Manual BOSCH Invented for life MIC ALM Alarm Card 8 input alarm card for MIC 240PSU MIC 115PSU MIC 24PSU MIC 12PSU Power Supply Units Installation and Operation Manual Chapters 1 Introduction 2 MIC ALM Installation Instructions 3 MIC ALM Washer Pump Installation Instructions 4 Technical Specifications BOSCH Bosch Security Systems Issue 1 Invented for life ATO CU CTO Mas cctiewenacscenevesenacedeeusearedseoevanssedecsensecaceases MIC ALM 8 input Alarm Card cccccecccsseccccsecccsccceecccsesccesceeeeseceusces NY ON SOAS aris nse tars ois so ssid E E A waoen teen E F CAULINGS EEEE EE E E EA A TEN EATI TT FH ACUI er E E Packaging Content Seen ne EEE MIC ALM 8 input Alarm Card A a a EEE MIC ALM 8 Input Alarm Card Installation EE Alarm Connections Configuring the Alarms through Camset Loading Camset V 50 E EA EEA EET Using the Setup BUHONS cos ccs css cess cesses covscs ssscesssscsvsvecavsesssuee msan Washer Pump Drive Function 0 0 0 0 00 cee cee ees Washer Pump Drive Installation 0 0 00 0 0 ccc cee cee cee cee eee cee cue essees Technical Specifications cccccsecsssceesceesceeseeesees Te hnical SP CCC AL ONS nc ace Gite cieecicctaseniss cneweaasiasnnccesese cee aun seceniawesss Bosch Security Systems Issue 1 BOSCH Invented for life Sa
7. Once the relay operation has been defined as above the Set Relays box must be installation selected to load the relay status into the MIC400 camera Washer Pump Installation Alarm Rearm Time f 7 f 5 10 BO CAUTION Electrical Danger Ensure all power is disconnected before opening or working upon the MIC400 Power Supply Unit Installation must be carried out by suitably qualified persons amp all local safety regulations should be followed Set Relays WARNING The MIC ALM has no fuses built in Fusing to the appropriate level MUST be fitted externally Nominally this would be 2 5A for 240V and 5A for 24V pumps Bosch Security Systems accepts no liability for damage or injury caused by incorrect fuse installation To connect a third party washer pump please do the following 1 Fitthe washer nozzle to the appropriate bracket wall or corner mount and then fix the washer nozzle bracket to the wall or corner bracket using one of the M8 fixing bolts ensure the washer nozzle points CHAPTER 3 Washer Pump Drive Function towards the camera BOSCH Bosch Security Systems Issue 1 Invented for life 2 Fit the washer pump and reservoir in a suitable location taking all necessary safety precautions observing the manufacturers instructions MIC ALM 8 Input Alarm Card Dimensions and all applicable local building codes 125 mm W x 25mm H x 60mm D 3 Connect the 5mm tubing from the pump to the washer nozzle
8. facilitate the installation of third party Washer Pumps amp Reservoirs a washer nozzle kit MIC WKT IR kit is available from Bosch Security Systems Along with the MIC WKT IR kit the MIC ALM Card provides the required accessories to fit a third party washer pump and reservoir to a MIC400 camera The MIC WKT IR kit consists of a 5mm twin jet washer nozzle and two 2 brackets to allow mounting of the washer nozzle on to a MIC400 camera base or corner mount bracket CMB utilising the M8 x 20mm fixing bolts holding the camera base or between wall and corner mount brackets The washer pump reservoir bottle amp 5mm tubing are not supplied by Bosch Security Systems and will need to be purchased separately to suit the particular installation Bosch Security Systems Issue 1 BOSCH Invented for life MIC ALM 8 Input Alarm Card Installation CAUTION Electrical Danger Ensure all power is disconnected before opening or working upon the MIC400 Power Supply Unit Y Installation must be carried out by suitably qualified persons amp all local safety regulations should be followed 250 ma TD o GENLOCH I GEN GND s IDEO p GND 1 The power supply unit should be switched off and unplugged prior to Yj e 3 P g oer carrying out any work WRR bes 5 7 DANGER MAINS SZ 1 3 2 Ensure that the four 4 card spacer supports fitted in the power supply are EEEE addon GENLOCH positioned in the left and right mos
9. fety Precautions The following symbols are used throughout this manual please pay careful attention to their meaning The lightning flash with an arrowhead symbol within a triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within a triangle is intended to alert the user to the presence of important safety operating and maintenance servicing instructions in the literature accompanying the appliance Important Safety Instructions CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DISCONNECT POWER SUPPLY BEFORE OPENING THE POWER SUPPLY UNIT POWER DISCONNECT POWER SUPPLY UNITS HAVE POWER SUPPLIED WHENEVER THE POWER CORD IS INSERTED INTO THE POWER SOURCE WARNING INSTALLATION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY IN ACCORDANCE WITH THE APPLICABLE LOCAL CODES BOSCH SECURITY SYSTEM ACCEPTS NO LIABILITY FOR ANY DAMAGES OR LOSSES CAUSED DUE TO INCORRECT OR IMPROPER INSTALLATION Se ae a 10 11 12 13 14 15 Read all instructions prior to installation Keep this manual for future reference Heed all warnings Install according to manufacturer s instructions Qualified persons only should install this product if in doubt consult a qualified installer Use correct electrostatic discharge handling p
10. ntly achieved through Camset Bosch Security Systems freeware PC based software Camset is a freeware program which allows the MIC400 range to be setup and configured through a serial port on a PC using a RS232 RS422 RS485 adapter such as Greenwich instruments GW232 which is available from all good electrical suppliers There is a different Camset for each respective protocol so ensure you have the correct one for your camera Loading Camset To access the Camset software please do the following 1 Install the Camset software as per the software installation instructions then open the Camset program you should see a screen such as this amp CamSet Forward Vision v50 r Bootup message and Addressing Preset and camera commands Comms Testing long test Zoom Out io Zoomin TEST 1 sec timeout I Fast Zoom I digital I cam comms Alarm test left soe tight DETECT WIPE down WASH P wipe SPEED s50 lamps OSD on off J Proportional PT Learn Preset RESET CAMERA Softstops and Dwell zones Cae aa Saabs IS OE Ean SUA TOGO RESET Interface Baud m matrix 4Wie 1200 9600 Enable Alarm comms 2 C 2Wite o C 4800 C 38400 Disable Alarm C Simplex Labell3 2 First the correct Serial port must be selected in the lower left hand corner of the screen using the mouse pointer For a notebook this can only generally be C
11. om www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 5 7180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com Bosch Security Systems B V 2009 Data subject to change without Bosch Security Systems Issue 1 BOSCH Invented for life
12. omm 1 Alternatively for notebooks without a serial Comm port a USB to RS232 adaptor can be used in which case the Comm port selected must be that mapped by windows for the USB to RS232 port usually Comm3 or Comm4 3 Once selected the programme is ready to receive messages from the camera if this fails to work check all connections check the correct version of Camset is being used for the protocol loaded on the camera and then RESET CAMERA Bosch Security Systems Issue 1 BOSCH Invented for life 4 RESET CAMERA should put a start up message in the thirteen text box the camera remembers its current position moves to the washer nozzle position windows in the top left of the programme panel Boot up message and and starts the washer and wiper Whilst the washer button remains depressed the addressing The address of the camera detected during boot up will be washer and wiper continue to run On release of the wash button the washer stops automatically loaded into the Current Address box and the camera returns to its previous view After a further two wipes the wiper stops too 5 When the camera is responding select the SETUPS button to enter the Setup section Auto Alarm On Off Operates as per the WashWipe On Off On all MIC400 s a single tamper switch input is supported With Auto Alarm selected on and an alarm position learned the Using the Setups Button camera will move to the alarm position when the tamper switch
13. rocedures when handling printed circuit boards to avoid damage to electro sensitive components Do not install near any strong heat sources such as furnaces Never push objects or pour liquids into the product enclosure as this can cause a fire or electrical shock hazard Only use electronic cleaning solvent in the unlikely event of the card requiring cleaning Ensure that the product is correctly earthed Use only the power sources indicated in this user guide and ensure that the current rating of the supply cable is adequate for the product Do not overload power supply sockets as this can be a fire or electrical shock hazard In the event of failure do not attempt to service this product yourself please contact Bosch Security Systems for assistance Only use approved attachments or accessories specified by the manufacturer Any changes or modifications made to the equipment not expressly approved in writing from Bosch Security Systems could prevent proper or safe operation of the product and will invalidate the warranty Please dispose of disused electrical amp electronic equipment at an environmentally compatible recycling facility contact Bosch Security Systems for further details Bosch Security Systems Issue 1 BOSCH Invented for life This product complies with the following EC directives EMC Directive 89 336 EC as amended Machinery Directive 98 37 EC LV Directive 73 23 EC RoHS Restriction of Hazardous
14. sch Security Systems MIC ALM 8 input Alarm Card for the MIC400 range of PTZ Cameras The MIC ALM 8 Input Alarm Card is a Printed Circuit Board as shown below and plugs directly into Non IR Power Supply Units for the MIC400 PTZ Camera ee oh aa f pe re lt A JHR 450 T suei EN 7 This card is only required for MIC400 Power Supply Units which do not support integrated Alarm operations these are the following MIC400 Power Supply Units MIC 240PSU MIC 12PSU MIC 24PSU MIC 115PSU The following MIC400 Power Supply Units include 4 Alarm inputs and a Washer Pump Drive function as standard and are not covered by this manual please refer to the MIC400 Power Supply Units Installation and Operation Manual instead MIC IR 240PSU MIC IR 12PSU MIC IR 24PSU MIC IR 115PSU Features The MIC ALM 8 input Alarm Card has the following features e 8 external alarm contacts e 2 Volt Free alarm output relays e Volt Free Washer Pump Drive function e Easy installation into MIC1 400 non IR power supply units Unpacking BOSCH Bosch Security Systems Issue 1 Invented for life e Check the exterior of the packaging for visible damage If any items appear to have been damaged in transit please inform the shipping company e Unpack the unit carefully although ruggedized this is electronic equipment and should be handled with care e Do not use if any component appears to be damaged Please contact Bosch Security Systems in
15. substances 2002 95 EC WEEE Waste Electrical amp Electronic Equipment 2002 96 EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local supplier for procedures for recycling this equipment Reference Glossary of Terms PTZ Pan Tilt Zoom PSU Power Supply Unit IR Infra Red Bosch Security Systems Issue 1 BOSCH Invented for life CHAPTER1 Introduction The MIC ALM 8 Input Alarm Card enables MIC400 cameras to support up to 8 external alarms such as Passive IR sensors tamper switches or other alarm triggers The MIC ALM is designed to plug directly into a non IR version of MIC400 power supplies and provides volt free contact closures from external sensors the card can be configured to accept normally closed contacts In addition the MIC ALM also provides for a washer pump driver function designed to enable MIC400 cameras to support third party washer kits to remotely clean the window of the MIC400 camera The MIC ALM provides a volt free contact rated at 240vAC up to 5 Amps to drive the third party washer pump there are no fuses on the MIC ALM card so fusing MUST be provided externally Versions Bosch Security Systems Issue 1 BOSCH Invented for life This manual covers the installation and operation of Bo
16. t mounting holes on the power supply card support spacers amp printed circuit board so that the MIC ALM card is supported in each noles clu corner _ IDEO LINt 3 Should you need to reposition the card spacers first remove the four 4 screws holding the power supply PCB to the enclosure turn the PCB over and remove the two 2 card spacer supports these spacers should be re fixed at the correct positions shown as A and B on Figure 1 below a se holes 4 Insert the MIC ALM Card so that the connector labelled CN1 as shown on Figure 2 MIC ALM 8 Input Alarm Card PCB Layout Figure 2 below plugs into the CN1 header on the Power Supply labelled C on Figure 1 Then fix to the card spacer supports using M3x6 screws a C Connection Header CN1 5 The MIC ALM is now ready to accept third party external alarm and washer pump electrical connections Please see Alarms Connections and Washer Pump Installation for more details E N an RN2 Figure 1 MIC400 non IR Power Supply PCB Layout Alarm Connections BOSC Bosch Security Systems Issue 1 B H Invented for life CAUTION Electrical Danger Ensure all power is 3 For external outputs connect to the auxiliary contacts HD3 or HD5 disconnected before opening or working upon the MIC400 respectively as shown below Power Supply Unit Installation must be carried out by suitably qualified persons amp all local safetv regulations should be followed