Home

NMEA 2000 to NMEA 0183 Gateway NGW-1

image

Contents

1. The Returns Number must be clearly visible on both the external packaging and any documentation returned with the product Any returns sent without a Returns Number will incur a delay in being processed Table 3 Diagnostic LED 2009 Active Research Limited Page 9 Actisense Product order codes NMEA 2000 gt USB Interface Special version required to connect the NMEA 2000 network to the USB port of a computer running NMEA 0183 compatible software NMEA 2000 Serial Interface with ISO Drive Standard version required to connect the NMEA 2000 network to an NMEA 0183 device or computer serial port Company Information Active Research Limited Unit 5 Wessex Trade Centre Ringwood Road f Poole Dorset UK BH12 3PF Telephone 01202 746682 International 44 1202 746682 Fax 01202 746683 International 44 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com Actisense is a registered trademark of Active Research Limited 2009 Active Research Limited Page 10 The Actisense NGW 1 USB allows NMEA 0183 software to talk and listen to NMEA 2000 devices on an NMEA 2000 network By translating NMEA 2000 data into the NMEA 0183 equivalent and vice versa the NGW 1 USB enables information to be shared between NMEA 0183 based PC navigation software and any instrument on the NMEA 2000 network The NGW 1 USB
2. 1 USB s built in firmware is held in flash memory allowing quick and easy upgrades using either the latest NGW 1 USB ActiPatch or alternatively the NMEA 2000 Gateway Configuration Tool running on a PC connected to the NGW 1 USB It is our policy to provide these updates free on the Actisense website www actisense com so that the NMEA 2000 to NMEA 0183 Gateway NGW 1 USB can be further developed over time and should there be any bugs reported in the firmware they can be promptly fixed without the unit requiring to come out of commission 2009 Active Research Limited Connecting devices together The NMEA 2000 standard The NMEA 2000 system is a low cost data network operating at 250 kbits sec utilizing the Controller Area Network CAN Multiple devices can be connected together on a single trunk cable to simply and easily share information between themselves NMEA 2000 uses a shielded cable and a differential signalling scheme whereby two wires are used to transmit the NMEA data named CAN High and CAN Low These connections will be labelled as NET HI and NET LO respectively Power is also supplied through the NMEA 2000 cable named NET Supply and NET Common These connections will be labelled NET SUP and NET COM respectively on the PCB Please refer to the Connecting to the NMEA 2000 Network section for an example of these connection methods Page 5 Actisense Connections O
3. LEDs can be used to debug potential problems If both an NMEA 0183 talker and a listener are connected it is possible to analyse which is working by disconnecting one of them or by stopping the computer from sending data NMEA 2000 LED does not Check that the NGW 1 USB is connected to the NMEA 2000 network that the flash when the data is received NMEA 2000 network is operational and that the required PGN messages are from the NMEA 2000 network selected for transfer by using the NGW Configuration Tool Check that the NGW 1 USB is connected to a PC USB port that the device USB LED does not flash when is recognised in the Windows Control Panel with the correct COM port refer to the USB data is received USB Configuration section in USB Install User Manual and that the required messages are selected to be transferred by using the NGW Configuration Tool Indicates that the NGW 1 USB is powered but no data is received from either connection If data should be being transferred through then check that the required PGN messages are selected by using the NGW Configuration Tool Both LEDs flash together once every 10 seconds If the error persists please contact Actisense support to help trace the issue before considering the return of the product If Actisense support concludes that the NGW 1 USB unit should be returned to Actisense refer to the Company Information section a Returns Number will be issued by the support engineer
4. s isolated USB connection makes it one of the best and safest ways to connect your computer to an NMEA 2000 network Just connect and relax knowing that Actisense has it secured NMEA 2000 Connection NMEA 2000 network is opto isolated from the USB connection to offer 2500 volts of protection NMEA 2000 current draw 20 mA typical Terminal block available for user cable connection Cable length 1 5 metres Environmental System Requirements Supported OS s Windows 2000 XP and Vista and MAC OS X check website for other versions USB drivers included on CD All NMEA 2000 instruments on the network can see translated NMEA 0183 data sent from the PC software PC software can receive translated data from any NMEA 2000 instrument Electrical isolation separates the two networks protecting against ground loop faults This creates a protected computer and a safe installation The NGW 1 device appears as a Virtual COM Port VCP compatible with almost all NMEA 0183 software Certifications CE EN60945 Tested and certified NMEA 2000 compliant Recommended operating temperature 20 C to 70 C Splash proof plastic casing USB Specification v1 1 and v2 0 compliant Up and downstream buffers for smoother data transfer Current draw 30 mA typical Baud rates 4800 to 230400 Cable length 1 8 metres Guarantee 3 years return to base provided with sealing cable glands certified to IP54 Stainless steel case scr
5. 0O000000 En no H MUU mg NGW 1 A USB 0B3 Figure 1 All external connections Figure 1 shows an internal view of the NGW 1 USB Printed Circuit Board PCB 1 NMEA 2000 Interface A five way screw terminal block is supplied for connecting the NMEA 2000 cable The CAN interface is fully compatible with the NMEA 2000 standard Actisense supplies a pre fitted four core screened cable for the NMEA 2000 connection fitted with a male micro fit connector The colour codes used for this cable are Shield Screen SHIELD If you need to use your own NMEA 2000 cable the five way screw terminal block is provided within the NGW 1 to allow easy connection along with a spare cable gland that should be fitted on to the new cable to help maintain the water protection level Any such cable is required to conform in full to the NMEA 2000 specification and be no longer than 6 metres maximum drop length 2 NMEA 2000 indicator LED This LED flashes when NMEA 2000 data set to be transferred is received by the NGW 1 USB It can be clearly seen through the NGW 1 USB s translucent lid when the case is closed 2009 Active Research Limited 3 A mic
6. AN H 40V 40V see note 2 NMEA 2000 CAN Bus line CAN H CAN L Receiver CAN H CAN L common mode input Resistance Differential input resistance BER O alee sp gt 35 30 NO OO or a o Na Sa O 9 O lt 200 200 90 100 Bo A A 5 USB Comms Input Output Input to Ground Full Galvanic Opto isolation protection Baud rate Configurable Baud rate 4800 900 230400 bps HE Table 2 NGW 1 USB specifications All specifications are taken with reference to an ambient temperature T of 25 C Note 1 Current consumption measured under no load conditions 2 This parameter is periodically sampled and not 100 tested 2009 Active Research Limited Page 8 NMEA 2000 to NMEA 0183 Gateway NGW 1 USB Troubleshooting guide This guide will concentrate on all relevant troubleshooting issues above simple cable connection faults Therefore the cables between the NGW 1 USB hardware and any other devices should be checked as a matter of course before continuing with this guide Status LEDs The NGW 1 USB hardware has two bright LEDs that can be seen through the case to indicate when data is received from either the USB device or NMEA 2000 network connection It is an important point to note that these two LEDs can only show when their respective data is RECEIVED it is not possible to show both transmit and receive simultaneously on a single colour LED These
7. Actisense NMEA 2000 to NMEA 0183 Gateway NGW 1 USB Hardware revision A Installation Manual Issue 1 00 a Gateway between the NMEA 2000 network and the USB port of a computer running NMEA 0183 compatible software or a USB compatible NMEA 0183 device a Complete electrical isolation of 2500 volts between USB and NMEA 2000 a Fully configurable via USB port or through the NMEA 2000 network NMEA 2000 to NMEA 0183 Gatewa NGW 1 USB Contents Important notices Notices Foreword Introduction Technical features Software updates Connecting devices together The NMEA 2000 standard Connections Connecting to the NMEA 2000 Network NMEA 2000 connections Driver Installation Guide Specifications Troubleshooting guide Status LEDs Product order codes Company Information 2009 Active Research Limited o O SS ss nN Oa aaa rth ARARA bh O Page 3 Actisense Important notices Actisense and the Actisense logo are registered trademarks of Active Research Limited All rights are reserved The contents of this manual may not be transferred or copied without the express written permission of Active Research Limited All other trademarks are the property of their respective owners The Actisense NMEA 2000 to NMEA 0183 Gateway NGW 1 USB is intended for use in a marine environment primarily for below deck use If the NGW 1 USB is to be used in a more severe environment such use may be consid
8. e to the NMEA 0183 instrument Full information on the complete Actisense product range and supporting software packages can be found on the Actisense website www actisense com Page 4 NMEA 2000 to NMEA 0183 Gatewa NGW 1 USB Technical features High speed 32 bit ARM processor capable of up to 40 million instructions per second Flash ROM technology that supports automatic programming for quick and easy updates 10 000 erase cycles and a 10 year Data Retention provides carefree user configuration On chip memory store allows buffering of short term NMEA data allowing the unit to smooth short term peaks in the NMEA data flow Fully configurable via the USB or over the NMEA 2000 network allowing optimisation of the PC interface to better suit the system it is a part of NMEA 2000 interface offers 2500 volts of opto isolation protecting the system even during the most extreme fault conditions and fully compliant with the NMEA 2000 standard for interfacing with the NMEA 2000 network Separate USB and NMEA 2000 network power offer easy installation with no need for a direct connection to the vessels main battery supply The NGW 1 USB takes power from the USB connection to power its USB circuitry and power from the NMEA 2000 connection to power its NMEA 2000 circuitry This creates total isolation between both power sources to completely eliminate the risk of ground loop faults occurring Software updates The NGW
9. earch Limited Foreword At Active Research Limited we recognise that instructions are often skipped so we have aimed to write this document in an informative and direct manner that will aid the user We have covered all the points a typical user needs to know Please read all sections before installing and using the NGW 1 USB and any referenced software programs Introduction The NGW 1 USB allows computers and USB compatible NMEA 0183 electronic equipment to be connected to a vessel s NMEA 2000 network This can allow equipment installers to adopt the NMEA 2000 network early whilst connecting any existing NMEA 0183 devices to the new bus standard The NMEA 2000 network can reduce installation costs of marine equipment and greatly reduce a boat s wiring harness complexity leading to improved reliability and reduction in unnecessary weight Now only a single cable is required from the bridge to the engines sensors and all other NMEA 2000 instruments on the boat NMEA 2000 uses the CAN Bus system prevalent in most modern cars to provide the quality and security of data transmissions that the NMEA 0183 bus can never hope to provide This enables NMEA 2000 products to achieve better transmission reliability in the passage of data through the vessel The NMEA Gateway can transfer data from an NMEA 0183 source and place that data on the NMEA 2000 bus or it can take NMEA 2000 data from the NMEA 2000 bus and make it availabl
10. ered misuse under the seller s guarantee The NGW 1 USB has been certified to comply with the European directive for Electro Magnetic Compatibility EN60945 and is appropriately CE marked Operation of the unit should be in conjunction with appropriate CE approved shielded connectors and cabling used in accordance with the CE directive EN60945 Any EMC related issues should be reported to Active Research immediately to allow the company to rectify or resolve EMC related problems in accordance with its obligations under EN60945 If the unit is misconnected so that compliance failure occurs the company shall not be held responsible for compliance failure until suitable EMC guidelines for connection are seen to have been taken Notices When using this document please note the following The products described in this manual and the specifications thereof may be changed without prior notice To obtain up to date information and or specifications contact Active Research Limited or visit the Actisense website www actisense com Active Research Limited will not be liable for infringement of copyright industrial property right or other rights of a third party caused by the use of information or drawings described in this manual Active Research Limited will not be held responsible for any damage to the user that may result from an accident during operation of this unit when used in accordance with this document O 2009 Active Res
11. ews Humidity 0 80 RH ai USB 1 1 amp 2 0 Active Research Limited Unit 5 Wessex Trade Centre Ringwood Road Poole Dorset UK BH12 3PF Telephone 44 0 1202 746682 Fax 44 0 1202 746683 Actisense on the Web For advice support and product details E mail support actisense com Website www actisense com Actisense is a registered trademark of Active Research Limited
12. isense cable If a different length cable is required an NMEA 2000 certified cable of the required length maximum 6 metres should be connected to the vessel s NMEA 2000 network using a standard male NMEA 2000 connector The standard wiring connection can be seen in Figure 2 Note 1 Wire colours are for guidance only The colours given relate to the supplied Actisense cable and the NMEA 2000 standard cable definition O 2009 Active Research Limited Driver Installation Guide The NGW 1 USB makes use of a virtual serial port driver know as the Virtual COM Port VCP driver to interface between the USB port on the PC and the Actisense product NGW This driver allows software running on a computer to communicate with the NGW 1 USB as if it was connected to a standard serial port on the computer when in fact all communication is done over the USB connection Please read the USB Driver Install Manual document that accompanies this NGW Install Manual for full details on how to install the NGW 1 USB drivers Page 7 Actisense Specifications Parameter Tomos Tn mx un Supply Supply current see note 1 6 NMEA 2000 CAN Bus line CAN H CAN L Transmitter Recessive bus voltage Dominant bus voltage CAN H l Dominant bus voltage CAN L Recessive differential output voltage 50 Dominant differential output voltage 1 5 Short circuit output current CAN H VCAN H 5V Short circuit output current CAN L VC
13. ro connector to connect to the supplied USB type A cable This connector should not normally be removed it is installed at the factory and is not customer serviceable 4 USB indicator LED This LED flashes when USB data set to be transferred is received by the NGW 1 USB It can be clearly seen through the NGW 1 USB s translucent lid when the case is closed To open the NGW 1 USB remove the two screws in the base of the unit then slide off the top of the case The cable glands need to be slid out from the top of the case in order to access the internal connections The NGW 1 USB circuitry will be left attached to the base of the unit and the two supplied cables attached to their connectors Note When opening the NGW 1 USB case be aware that the circuitry inside is not 100 protected against static electricity Please ensure that when opening the case you use precautions against static damage by only touching the connector block and by holding the unit by its plastic base In this way the risks of static damage will be minimised Page 6 NMEA 2000 to NMEA 0183 Gatewa NGW 1 USB Connecting to the NMEA 2000 Network i FE cp Figure 2 NMEA 2000 connections NMEA 2000 connections The Actisense NGW 1 USB is designed to be connected to the vessel s NMEA 2000 network using the supplied pre fitted Act

Download Pdf Manuals

image

Related Search

Related Contents

  環境報告書2010年版(926KB)  Untitled  Alternativ versjon 2/11  Ça n`arrive pas qu`aux autres  Homelite UT20930 User's Manual  Ata da sessão do PE 31.2012  VDO - MC 2.0  8830 PC DOCUMENT SUBMISSION TOOL USER MANUAL 6  MRBS User Manual  

Copyright © All rights reserved.
Failed to retrieve file