1. supported The manual switches override the PresentValue at priority level 1 manual life safety of the respective channel Priority level 1 and 6 are not writable using the BACnet WriteProperty service
2. BACnet PICS DO 8 Date 07 12 2009 Vendor Name MBS GmbH Product Name BACnet I O module DO 8 Product Model Number DO 8 Application Software Version 1 0 Firmware Revision 1 2 BACnet Protocol Version 1 BACnet Protocol Revision 4 Product Description The MBS DO 8 module is a highly reliable BACnet Digital Output module supporting 8 channels digital relay output The module supports all standardized BACnet MS TP baud rates from 9600 up to 76800 bit s The modules may run in MS TP master and slave mode BACnet Standardized Device Profile Annex L O BACnet Operator Workstation B OWS O BACnet Building Controller B BC O BACnet Advanced Application Controller B AAC M BACnet Application Specific Controller B ASC O BACnet Smart Sensor B SS O BACnet Smart Actuator B SA List all BACnet I nteroperability Building Blocks Supported Annex K DS RP B Data Sharing ReadProperty B DS WP B Data Sharing WriteProperty B DS COVU B Data Sharing ChangeofValue Unsolicited B DM DDB B Device Management DynamicDeviceBinding B DM DOB B Device Management DynamicObjectBinding B DM DCC B Device Management DeviceCommunicationControl B DM RD B Device Management ReinitializeDevice B The fixed password for DeviceCommunicationControl and ReinitializeDevice services is BACnet MBS GmbH encoded in the ANSI X3 4 character set Segmentation Capability O Segmented requests supported Window Size O Segmented responses supported Wi
3. dentifier Property Datatype 1 2 Obj ect_Identifier BACnetObjectl dentifier 1 8 R R Object_Name CharacterString R W Object_Type BACnetObjectType R IR Present_Value BACnetBinaryPV W w Description CharacterString max 16 characters O W Device_Type CharacterString max 16 characters O w Status_Flags BACnetStatusFlags R R Event_State BACnetEventState R R Reliability BACnetReliability O Out_Of_Service BOOLEAN R W Polarity BACnetPolarity R W Inactive_Text CharacterString max 8 characters Ol w Active_Text CharacterString max 8 characters O1 w Change_Of_State_Time BACnetDateTime 02 Change_Of_State_Count Unsigned 02 Time_Of_State_Count_Reset BACnetDateTime 02 Elapsed_Active_Time Unsigned32 03 Time_Of_Active_Time_Reset BACnetDateTime O3 Minimum_Off_Time Unsigned32 O Minimum_On_Time Unsigned32 O Priority_ Array BACnetPriorityArray R IR Relinquish_ Default BACnetBinaryPV R W Time_Delay Unsigned O04 Notification_Class Unsigned 04 Feedback_ Value BACnetBinaryPV 04 Event_Enable BACnetEventTransitionBits 04 Acked_ Transitions BACnetEventTransitionBits 04 Notify_ Type BACnetNotifyType O04 Event_Time_Stamps BACnetARRAY 3 ofBACnetTimeStamp 04 Profile_ Name CharacterString O DS COVU B proprietary 700 BOOLEAN FALSE no COV TRUE COV U Oo W 1 BACnet Conformance Code 135 2004 2 BACnet Conformance Code DO 8 R Required Readable W Writable O Optional Not
4. lass O Active _VT_Sessions List of BACnetVTSession O Local_Time Time O Local_Date Date O UTC_Offset INTEGER O Daylight _Savings_Status BOOLEAN O APDU_Segment_Timeout Unsigned O APDU_Timeout Unsigned 10 000 ms R R Number Of APDU _ Retries Unsigned 5 R R List_Of Session Keys List of BACnetSessionKey O Time_Synchronization_Recipients List of BACnetRecipient O Max_Master Unsigned 127 O R Max_Info_Frames Unsigned 1 O R Device_Address_Binding List of BACnetAddressBinding empty R R Database_Revision Unsigned 1 R_ IR Configuration Files BACnetARRAY N of BACnetObjectl dentifier O Last_Restore_Time BACnetTimeStamp O J Backup Failure Timeout Unsigned16 O Active_COV_Subscriptions List of BACnetCOVSubscription O Slave_Proxy_Enable BACnetArray N of BOOLEAN O Manual_Slave_Address_Bindin List of BACnetAddressBindin O Auto_Slave_Discovery BACnetArray N of BOOLEAN O Slave_Address_Binding List of BACnetAddressBinding O Profile_Name CharacterString O Baud rate proprietary 701 UNSIGNED 9600 19200 38400 76800 Oo W MAC address proprietary 702 UNSIGNED 0 127 master 128 254 slave Oo W Ne Il Of2 I BACnet Conformance Code 135 2004 BACnet Conformance Code DO 8 Required Readable Writable Optional Not supported Binary Output Object Type Property I
5. ndow Size Data Link Layer Options BACnet IP Annex J BACnet IP Annex J Foreign Device ISO 8802 3 Ethernet Clause 7 ANSI ATA 878 1 2 5 Mb ARCNET Clause 8 ANSI ATA 878 1 RS 485 ARCNET Clause 8 baud rate s MS TP master Clause 9 baud rate s 9600 19200 38400 76800 N OOO0O0O M MS TP slave Clause 9 baud rate s 9600 19200 38400 76800 o Point To Point EIA 232 Clause 10 baud rate s o Point To Point modem Clause 10 baud rate s Oo Oo LonTalk Clause 11 medium Other Device Address Binding Is static device binding supported This is currently necessary for two way communication with MS TP slaves and certain other devices O Yes Mi No Networking Options O Router Clause 6 O Annex H BACnet Tunneling Router over IP O BACnet IP Broadcast Management Device BBMD O Does the BBMD support registrations by Foreign Devices Character Sets Supported Indicating support for multiple character sets does not imply that they can all be supported simultaneously ANSI X3 4 IBM Microsoft DBCS ISO 8859 1 ISO 10646 UCS 2 ISO 10646 UCS 4 JIS C 6226 OOOOON If this product is a communication gateway describe the types of non BACnet equipment networks s that the gateway supports No gateway functionality yet Remarks If set to slave mode the supported Device Profile is reduced to B SA The BIBB DS COV U B is not supported in slave mode The BIBB DM DCC B su
6. pports infinite lifetime only The BIBB DM RD B supports both cold start and warm start The BIBBS DM DCC B and DM RD B are supported with the optional password only The fixed password is BACnet MBS GmbH Standard Object Types Supported The supported object types are DEVICE BACnetObjectType ENUMERATED 8 and Binary Output BACnetObjectType ENUMERATED 4 Creation and Deletion of objects is not supported Device Object Type Property Identifier Property Datatype 1 2 Object_ dentifier BACnetObjectl dentifier R W Object_Name CharacterString max 16 characters R W Object_Type BACnetObjectType R R System_ Status BACnetDeviceStatus R R Vendor Name CharacterStrin R_ R Vendor_Identifier Unsigned16 R_ R Model_ Name CharacterString R R Firmware Revision CharacterString R R Application_Software_Version CharacterString R R Location CharacterString O Description CharacterString O Protocol_Version Unsigned R_ R Protocol Revision Unsigned R R Protocol Services Supported BACnetServicesSupported R R Protocol_Object_Types_Supported BACnetObjectTypesSupported R R Object_List BACnetARRAY N of BACnetObjectl dentifier R R Max _APDU_ Length Accepted Unsigned max 50 R R Segmentation Supported BACnetSegmentation R_ R Max Segments Accepted Unsigned O VT_Classes Supported List of BACnetVTC